Tender For Special Repair To Bldg No P-39A (Main Office) Under Ge (South) Meerut Cantt., meerut-Uttar Pradesh

Tender Notice

51591216
Corrigendum : Tender For Special Repair To Bldg No P-39A (Main Office) Under Ge (South) Meerut Cantt.
Tender
Indian
Uttar Pradesh
Meerut
01-11-2025

Tender Details

Tender For Special Repair To Bldg No P-39A (Main Office) Under Ge (South) Meerut Cantt.; 1 Demolition ofbrick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc all as specified & directed 2 M&L for brick work with sub class B Bricks (Old Size)straight or curved on plan exc 6 m mean radis built in CM 1:6 complete all as specified and directed. 3 M&L for brickwork with subclass `B bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks complete all as specified and directed. 4 Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises. 5 Material & labour for vitrified coloured tiles of size 600mmx600mm, 8-10mm thick, in floor set and jointed in neat cement slurry and pointed in white/ coloured cement to match in floor over and including 15mm thick cement screed bed of CM (1:6) complete all as specified and directed. 6 Material & labour for vitrified coloured tiles of size 600mmx600mm, 8-10mm thick, as in skirting and jointed in neat cement slurry and pointed in white/ coloured cement to match in floor over and including 10mm thick rendering of CM (1:4) complete all as specified and directed. 7 Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each. 8 Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.50 Sqm & n exc 4 Sqn each. 9 S&F powder coated anodised aluminium Ventilators Side or top or bottom hung type as per site requirement with sash bars, aluminium sections weighing 0.55 Kg/mtr (minimum) inclstainless steel mosquito proofing wire mesh fixed with , clips, frame , necessary joining cleats, glazing clips, neoprene rubber gasket with aluminium beading screws suitable anodised fittings such as hinges, handles including powder coated anodised aluminium frame,with one or more rebates including S&F 5.50 mm thick tinted pin headed glass complete all as specified and directed. 10 S&F powder coated anodised aluminium windows side hung type (making space for AC or coolers) with sash bars, aluminium sections weighing 0.55 Kg/mtr (minimum) inclstainless steel mosquito proofing wire mesh fixed with , clips, frame , necessary joining cleats, glazing clips, neoprene rubber gasket with aluminium beading screws suitable anodised fittings such as hinges, handles including powder coated anodised aluminium frame, with one or more rebates including S&F 5.50 mm thick black glass complete all as specified and directed. 11 M&L Framed work such as grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290 Gde-165 complete all as specified. 12 Material & Labour For Powder coated anodised aluminium Door Shutter without sash bar, aluminium section weighing 0.55 kg/Mtr (minimum) including necessary joining cleats, Handles, Locking Arrangement ,door stopper, Hydraullic door closer, Glazing clips, rubber packing anodised aluminum snap beading, screws suitable anodised aluminium frame with one or more rebates including supply and fix 5 to 6 mm thick black glass complete all as specified and directed Make :- Hindalco/Jindal or equivalent make as specified in PS. 13 Taking down old existing water proofing treatment from the top of RCC/ arch slab, including taking down existing PCC padding or plaster and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises complete all as specified & directed. 14 Material and Labour for 20mm thick cement paster in CM 1:4 mixed with WPC @ 2 % by weight of cement finised even and smooth without using extra cement on roof surface and wall (WPC will be measured and paid seperately as supply only rate). 15 M& Lfor PCC padding 1:2:4 type B1(using 20 mm graded stoneaggregate) average thickness 25mm,finished fair and even without using extra cement on roof surfaces complete all as specified and directed. 16 Material & labour for cleaning of concrete or plasteredsurfaces of roof and applying priming coat using with bituminous primer @ 0.30kg per Sqm followedevenly by a tack coat @ 1.20 kg per Sqm using 85/25 grade industrial hot blown bitumen, over it laid with 3mm thickAPP modified polymeric waterproofing membrane minimum weight 3.6 Kg per Sqm reinforced with non-woven polyester fabric (weightnot less than 160 Gm per Sqm) unrolled & bonded to substrate with side and end laps 75mm & 100mm as per manufacturer’s instruction andapplying over it a tack coat using 85/25 grade industrial hot blown bitumen bitumen @ 1.20 kg per Sqm and finally finished the top of polymericwater proofing membrane with a coat of bituminous aluminum paint @ 0.20 kg per Sqm as per manufacturer’s instructions, complete all as specified & directed. 17 Supply only integral water proofing compound all as in specified & directed. 18 Taking down of cementplaster of any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc. 19 M&L for 10 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and fair complete all as specified & directed. 20 M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces finished even and smooth with out usingextra cement complete all as specified & directed. 21 Materials & labour for prepration of newely plastered surface and finishing the surfaces of wallwith wall putty and applyingtwo coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed. 22 M&L for preparation of new plastered surface of wall by applying 2mm thick wall care putty and making the surface smooth Finishing walls and applyingAcrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) using roller for painting complete all as specified & directed. 23 M&L for preparation of Old Plastered surface of wall and Complete removal of existing treatment by mechanical means plastered old surface of wall and applying 2mm thick wall care putty over one coat of primer and making the surface smooth and applying two coat of Acrylic smooth exterior paint of required shade ( two coat @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2020 kg/10sqm) using roller for painting complete all as specified & directed. 24 M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel Paint over one coat of Red oxide primer all as specified & directed. 25 Material & labour for 5 mm thick plaster in CM 1:3 on ceiling surfaces, surfacesfinished even and smooth without using extra cement complete all as specified and directed. 26 Materials & labour for prepration of newely plastered surface of ceiling and finishing the surfaces of ceiling with wall putty and applyingtwo coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed. 27 S&FHollow PVC Wall Lining consisting of PVC Insulated Panels 2 mm thick plain colour PVC sheet duly fitted into the wall as per specifications and drawing and Thickness of insulated PVC wall lining 1 to 3 mm thick mm Insulated Panel with Single Side Prelam PVC sheet used instead of plain colour sheet complete all as specified and directed including Dismantling of old wall panelling if required complete all as specified and directed. 28 S&F in repaircromium plated 15 mm bore size Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified. 29 Dismantling OH water tank of capacity exc 250 ltr but not exceeding 500 ltr and removing from site complete. 30 S&F triple layer of any colour 500 Ltrs Rotational moulded polyethylene (PVC) water storage tanks cylindrical vertical with closed top including nipple nuts and washers for fixing inlet, outlet/washout pipes and air vent pipes complete all as specified. 31 S & F Ball valves 20 mm dia high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms/ 50mm-1240 gms) 32 Supply, fix 15 mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing completeincluding taking down of old GI tubes of any grade complete all as specified and directed. 33 Supply, fix 20 mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete including taking down of old GI tubes of any grade complete all as specified and directed. 34 S&FGun -metal,globe or gate valves,with iron wheel head ,screwed both ends for iron pipe and fixed for 15 mm pipe. 35 S&FGun -metal,globe or gate valves,with iron wheel head ,screwed both ends for iron pipe and fixed for 20 mm pipe. 36 S & F in repair 25mm dia Stainless steeldecorated curtain rod with braket and ring complete all as specified and directed. 37 M&L for granite (of any type) tiles 15 to 20 mm thick machine cut for cills of windows, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types including Screed bed or bedding layer of mortar 15 mm thick in C M 1:6, for laying floor finish Complete all as specified an directed. 38 M&L for repair to overhang portion of chajja, facia, dropwall and Chimeny etc. for continuous work by providing PCC(1:2:4) Type B-0 and finished with CM(1:3) after taking down of damaged portion of RCC work by maintaining same level and finished the surface to match with the existing surface by providing same finish. (Height of work to be considered from GL and upto 7m from FFL of Ground Floor.) (Note : Wherever reinforcement and formwork is required to be provided will not be paid seperately, and contractor have to inform the department one day in advance afterbinding of reinforcement and the rate Quoted against the item shall inclusive ofreinforcement and formwork if required at site) 39 M&L for provision of powder coated GI frame work(snap grid) suitable for size as in false ceiling of size 605mm x 605mm including fixing 4mm thick gypsum board in ceilingsize 60cm x 60cm fixed to metacil snap gird and dismantling wall and ceiling boards or insulation boards/slabs any thickness including cover fillets, consisting of followings andall as directed:-i) Powder coated GI sections incorporated in frame work shall conform to designation 63400 given in IS: 737-1986. ii) The snap grid shall consist of powder coated GI main /cross tee of size 36.5mmx25mmx1.0mm thick and 25mm x 25m x1.0mm thick, respectively.iii) Snap grid frame shall be fixed to ceiling withsupporting hangers consisting of S & F2mm to 4mm dia mild steel GI wire.iv) The main and cross tees shall be jointed at junction/crossings with powder coated GI angle bracket, of size 15mmx15mmx1.0mm thick, fixed with suitable mild steel, bolts, nuts and washers all as per manufacturer’s instructions.v) The snap grid (main/cross tee section) shall be supported at ends all along the wall with powder coated GI angle of size 25mmx25mmx1.0 mm powder coated GIthick. vi) Size of the snap grid shall be 605mm by 605mm. vii) Minimum average thickness of powder coating shall be 15 micron vii) including dismantling of old false ceiling of any type board including any type snapgrid complete all as specified and directed. 40 Demolition of cement concrete of ground floor n exc 15 cm in depthin any position nototherwise specifically provided for, complete all as specified and Directed 41 M&L for 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in path /plinth protection , finish even & smooth without using extra cementall as specified and directed. 42 M&L for 60mm thick ColouredPCC tile (interlocking type) jointed filled with sand and campacted with mechanical plate vibrator Complete all as specifed and directed. 43 M&L for sand for cushioning, interlocking tiles joint to be filled with sand, including spreading and levelling in layers n exc 25 mm thick Complete all as specified and directed. 44 M&L for 75 mm thick cement concrete 1:3:6 type C-2 using (40 mm graded stone agg) as in sub base Complete all as specified and directed. 45 S&F Pre-cast cement concrete block masonry 1:2:4 Type B-1 (using 20mm graded stone aggregates) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, including exacavation for fixing and making good complete all as specifed and directed. 46 Taking down carefully any type of battens or conduit point wiringwith or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site . 47 Material & labour forpoint wiring with FRLS PVC insulated 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, unsheathed copper conductor cable in and includingPVC concealed conduit of size 20mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, sunk zinc coated pressed steel terminal boxes including all cutting / chases etc in walls, with 3mm thick plastic laminated sheet cover including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings for One Tube light/bulb/street light point controlled by one, one way switch 05 / 06 Amps. 48 All as per item No 47 here-in-before but one ceiling fan point controlled by one, one way switch 05 / 06 Amps. 49 All as per item No 47 here-in-before but one 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch. 50 All as per serial item No 47 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch. 51 All as per serial item No 47 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 / 16 Amps socket outlet point on independent board. 52 Supply & fixing switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete. 53 Supply & fixing socket outlet 3 pin, 05 / 06 Amps flush type 240 volts complete. 54 Supply & fixing switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete. 55 Supply & fixing of socket outlet3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete . 56 Supply and fixdecorative LED Batten 20 Wattpolycarbonate housing integtrated typecomplete with all accessories and fixing material all as specified and directed. 57 Supply and fix lamp holder , PVC / polycarbonate type back plate suitable for batten fitting complete . 58 Supply & fixing of ceiling rose, 3 terminal PVC polycarbonate isolated body complete all as specified & directed . 59 Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt provison forfixing of 1 No MCCB 3 Pole100Amps 36 KA, 415 volts and 12 Nos MCBs inside of DB, with metal door and flush to wall including grouting and cutting in existingwall and making good disturbed surfacewith two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed. 60 Supply and fixing Isolator 4 poleB series 100 amps capacity AC 415 V,10kA complete all as specified and directed . 61 Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8way, with 200 Amps rated . 62 Supply & fixing MCBSPN, AC, 240 volts of 32 to 63Amps, C curve, 10 kA,. 63 Supply and fixing MCB SP, AC, 240 volts of 06 to 32 Amps, C curve, 10 kA,. 64 Supply and fixing LED luminaire 600 mm x 600 mm,40 watt, 220 V AC recessed type with highefficiency PMMA diffusersoftglare free light completewith driver, holders & LED lamp suitable for roofceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete. 65 Material and labour for sub main wiring with 04Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all MS conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.Note:- One meter of conduit along with 2x4 sq mm wire and one 4.0 sq mm earth shall be measured as one unit length. 66 Material and labour for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all MS conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.Note:- One meter of conduit along with 2x6 sq mm wire and one 6.0 sq mm earth shall be measured as one unit length. 67 Supply, laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 16 Sqmm 3.0 core armoured, PVC sheathed with aluminium conductor heavy duty. 68 Supply / laying and fixing 40mm bore galvanised steel tubes with all fittings, light grade, laid in trenches for cable protection complete. 69 Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 M depth in soft/ loose soil and gating out in soft / loose soil complete all as specified and directed. 70 M&L for washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling and hard punning complete. 71 Material and labour for contineous brick edging withwidth equal to the depth of the brick of whole sub class B bricks laid on edge complete. 72 Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick in soft / loose soil complete. 73 Removing surplus excavated materials n.exc. 50 Mtr and depositing where directed at a level n. exc. 1.5 Mtr above the starting point complete. 74 Supply and fixing LED building security light fitting 1x35 Watt luminarieswith die cast aluminium housing comprising epoxy poweder coated enclosed with glass cover in frame with high power LED white lampof capacity 35 watt including making connections complete with bracket fitting made out of GI pipe medium grade including clampsand nuts and bolts. 75 Taking down Ceiling fan and hook , sealing cable end , dismantling blades and removing fans and blade to stores for safe costudy. 76 Supply and fixing new ceiling fans complete with blades, down rods, electronic regulator compatible for BLDC fans and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor ( BLDC). 77 M&L for Ceiling fan hook made from steel structural, bracing support bend into shape for hanging of ceiling fan complete all as directed at site. 78 Supply and install hi wall split indoor and outdoor complete with cordless remote control unit and with in buit air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 1.5 Ton all as specified nand directed by engr-in-cgarg,( Note Old unsv AC of any type and size will be deposited to AGE E/M-II yard Only) 79 Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completioncomplete.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 25-10-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-11-2025
2 14-10-2025 Amendment to BOQ BOQ 18-10-2025

Key Value

Document Fees
INR 500 /-
Tender Value
INR 14.90 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail