}

Tender For Redevelopment Of Type Iv Staff Quarters And Conversion To Girls Hostel., Delhi-Delhi

Delhi University has published Tender For Redevelopment Of Type Iv Staff Quarters And Conversion To Girls Hostel.. Submission Date for this Tender is 24-10-2025. Building Work Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

51564446
Tender For Redevelopment Of Type Iv Staff Quarters And Conversion To Girls Hostel.
Tender
Indian
Delhi
Delhi
24-10-2025

Tender Details

Tender For Redevelopment Of Type Iv Staff Quarters And Conversion To Girls Hostel.; 1 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 2 15 mm to 40 mm nominal bore 3 Above 40 mm nominal bore 4 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 5 Up to 150 mm diameter 6 Above 150 mm dia up to 300 mm dia. 7 Above 300 mm diameter 8 Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 9 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 10 Up to 150 mm diameter 11 Above 150 mm diameter 12 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. 13 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 14 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 15 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. 16 In cement mortar 17 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): 18 From brick work in cement mortar 19 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 20 Of area 3 sq. metres and below 21 Of area beyond 3 sq. metres 22 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 23 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 24 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 25 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge 26 With cement mortar 1:4 (1 cement : 4 fine sand) 27 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. 28 All kinds of soil 29 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 30 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 31 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos E.C. 20% with 1% concentration 32 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 33 Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. 34 Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improvedurability andworkability without impairing strength;includingpumpingof concrete to site of laying, curing,carriage for allleads; but excluding the cost of centering, shuttering and finishingas per direction of the engineer-in-charge; for the followinggrades of concrete. Note: Extra cement up to 10% of the minimum specified cementcontent in design mix shall be payable separately. In case thecement content in design mix is more than 110% of the minimumspecified cement content, the Contractor(s) shall have discretionto either re-design the mix or bear the cost of extra cement. 35 All works upto plinth level : 36 Concrete of M10 grade with minimum cement content of 270 kg /cum 37 All works above plinth 38 Concrete of M10 grade with minimum cement content of 270 kg /cum 39 Concrete of M20 grade with minimum cement content of 270 kg /cum 40 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). 41 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. 42 Centring and shuttering including strutting, propping etc. and removal of form for 43 Stairs, (excluding landings) except spiral-staircases 44 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 45 Thermo-Mechanically Treated bars of grade Fe-500D or more. 46 Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : 47 Red sand stone slab 40 to 50mm thick 48 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 49 Providing, fabrication and fixing structural steelwork in built-up sections, trusses and framed work, for fixing of platform / staircase/ beam / slab with support at various levels as per Architectural drawings. All M.S. gusset plates, I-sections, C-Channel, M.S Joints cutting/bending , in stringers, treads, landings etc. of stair cases, including use of plate /chequered plate and G.I deck sheet on M.S Platform wherever required for complete installation of the M.S framework & deck sheet complete at all heights and levels. 50 Providing corrugated pre painted galvanized steel sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 51 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 52 M.S. tube 53 Providing and fixing of Rebaring of 12 mm dia of 300 mm depth Hilti Chemical Re-500 V4 in Existing RCC Structure as specified in Drawing complete in all respect as per entire satisfaction of Engineer- in Charge 54 Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in 55 Cement mortar 1:4 (1 cement : 4 coarse sand) 56 Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 57 Cement mortar 1:4 (1 cement : 4 coarse sand) 58 Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 59 Cement mortar 1:4 (1 cement :4 coarse sand) 60 12 mm cement plaster of mix : 61 1:4 (1 cement: 4 fine sand) 62 15 mm cement plaster on the rough side of single or half brick wall of mix : 63 1:4 (1 cement: 4 fine sand) 64 20 mm cement plaster of mix 65 1:4 (1 cement: 4 fine sand) 66 6 mm cement plaster of mix 67 1:3 (1 cement : 3 fine sand) 68 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 69 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 70 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 71 Primer 72 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 73 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 74 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 75 New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution 76 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 77 Glazed vitrified floor tiles polished finish of size 78 Size of Tile 600 x 600 mm 79 Glazed Vitrified tiles Matt/Antiskid finish of size 80 Size of Tile 600 x 600 mm 81 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. 82 Size of Tile 600x600 mm 83 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 84 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 85 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 86 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 87 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 88 Providing & fixing of Girls Hostelin Stainless SteelLetters of 24 Height with power Supply & Warrenty of 2 yearswith fittings complete with all respect. 89 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.10 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD specification, uPVC extruded glazing beads, interlocks and inline sash adapter (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, T-removing of matching polymers, PA6 grade spacer for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitered cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. ​Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with/without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3(ii) Sites with structure height more than 20m for all wind speeds 90 Fixed Window/Ventilator without mullion/transom 91 Using R1 Series with frame (33mm & Above) x (35mm & Above). (Height upto 0.90mt) 92 Ventilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coated handles. 93 Using R2 series with frame (39 mm & above) x (39 mm & above) & sash/mullion (39 mm & above) x (60 mm & above) (Height upto 1.2 metre) 94 Casement door double panel with french (false) mullion with zinc allow (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) podwer coated handles on both sides. 95 Using R3 Series with frames (55mm & above) x (50mm & above) & sash (55mm & above) x (85mm & above) & french (false) mullion (55mm & above) x (60mm & above). (Height upto 2.5mt.) 96 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. 97 Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturers specification and direction of engineer in-charge. 98 Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (pm 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (pm 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (pm 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement in as styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturers specification and direction of engineer-in-charge. 99 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) 100 For fixed portion 101 Powder coated aluminium (minimum thickness of powder coating 50 micron) 102 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of SPM College / Engineer In Charge (Door handle, lock and stopper etc. to be paid separately) 103 Providing and fixing PTMT Bottle Trap for Wash basin and sink 104 Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 105 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 106 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps 107 White Vitreous China Wash Angle back basin size 400 x400 mm with a single 15 mm C.P. brass pillar taps 108 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 109 Rectangular shape 453x357 mm 110 Rectangular shape 1500x450 mm 111 Providing & fixing white vitreous china short wall mounted rimless European type water closet with non-concealed PVC Flushing Cistern and internal fittings with C.P. bolts, nuts, C.I. chair or other hanging arrangement, with white solid plastic seat and lid, rubber buffers, with accessories, C.I/M.S. brackets painted with two or three coats of enamel paintofapprovedshadeoveracoatofprimer.C.P.brassscrewsandwoodencleats,including cutting and making good the wall and floors wherever required. 112 Providing and fixing squatting pan (Indian type WC) with 100 mm sand cast iron P or S trap, 10 litre low level cistern including flush pipe with manually controlled device (handle lever) conforming to IS : 7231with all fittings and fixtures complete, including cutting and making good the walls wherever required : 113 White vitreous china Orissa pattern WC pan of sie 585 x 440 mm with integral foot rests 114 ProvidingandfixingC.P.brassanglevalveforbasin mixerand geyserpointsofapproved quality conforming to IS:8931. 15 mm nominal bore 115 Providing and fixing C.P. brass long body bib cock with quarter turn of approved quality conforming to IS standards and weighing not less than 690 gms. 116 15 mm nominal bore 117 Providing and fixing PTMT grating of approved quality and colour. 118 125 mm nominal dia with 25 mm waste hole 119 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 120 Providing and fixing 15mm dia hygiene spray having 80 lpm water flow with body and spring action lever of SS304,ABS wall bracket and 1200mm long armoured hose, all complete 121 Providing and fixing trap of self-cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 122 100 mm inlet and 100 mm outletSand cast iron S&S as per IS: 3989 123 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 124 100 mm diameter 125 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete 126 32 mm dia 127 40 mm dia 128 Providing and fixing soil, waste and vent pipes : 129 100 mm dia Sand cast iron S&S pipe as per IS: 1729 130 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 131 100 mm dia pipe 132 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 133 For 100 mm dia pipe 134 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 135 100 mm diaSand cast iron S&S as per IS - 1729 136 Providing and fixing plain bend of required degree. 137 100 mm dia Sand cast iron S&S as per IS - 1729 138 Providing and fixing heel rest sanitary bend 139 100 mm diaSand cast iron S&S as per IS - 1729 140 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 141 100x100x100 mmSand cast iron S&S as per IS - 1729 142 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of SPM College / SPM College / Engineer In Charge. 143 15 mm nominal outer dia .Pipes. 144 20 mm nominal outer dia .Pipes. 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of SPM College / Engineer In Charge 146 20 mm dia 147 25 mm dia 148 32 mm dia 149 40 mm dia 150 50 mm dia 151 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 152 15 mm dia 153 20 mm dia 154 25 mm dia 155 32 mm dia 156 40 mm dia 157 50 mm dia 158 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 159 150 mm. dia. 160 250mm dia. 161 300mm dia. 162 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 163 100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 164 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 165 150 mm diameter 166 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) 167 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 168 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 169 Makingkhurras45x45cmwithaverageminimumthicknessof5cmcementconcrete1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 170 Supply and installation of ISI-marked Sintex brand HDPE (High-Density Polyethylene) water storage tank of approved quality and capacity 1000 liters, conforming to IS:12701 standards. Tank shall be UV-stabilized, multilayered (minimum 2–4 layers), leak-proof, rustproof, lightweight, and suitable for overhead or ground installation. It shall include inlet, outlet, overflow, and drain connections as per manufacturer’s specifications. Complete with necessary fittings such as threaded lid, brass float valve, and plumbing accessories. Installation shall be done with proper support base and as per site conditions and engineers instructions. 171 Providing & fixing Ball valve (with motorized actuator) of rating PN 1.0, wafer type, in cast iron body with Ductile Iron disc, EPDM seal, SS single piece shaft, conforming to IS-13095 of the following sizes complete with cast iron hand level companion flanges, bolts, nuts, washers & inserted rubber gaskets, as required and as per enclosed specification, with single phase Electrical Actuator, of 15Nm 400NmTorque, madeof aluminiumalloy(resistantto heat, acid , alkali, corrosion), and weather proofheavydutymotor,withstabilizedstartspeedtoeffectivelyavoidwaterhammering,with waterproofing seal (IP 67) for all housing seals, low noise level, built –in thermal protection complete as per approved type and specifications as per instructions of the Engineer-In-Charge (for pipes for fitting OHT’s). 172 32 mm dia 173 Providing & fixingofapprovedcoloured verticle type hotwater 25 ltr geysers. The inner container shall be made of copper sleeve with PUF insulation between inner and outer container, element pipe and heating element, pressure cum vaccume release, thermostat and thermal cutout arrangements and fusible plug. The outer container shall be of powder coated finish withallother accessories including fixing bracketscomplete as required. 174 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 175 Group- A 176 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 177 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 178 2 X 1.5 sq. mm + 1 x 1.5 sq. mm earth wire Metre 179 2 X 6 sq. mm + 1 x 6 sq. mm earth wire Metre 180 4 X 6 sq. mm + 2 x 6 sq. mm earth wire 181 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 182 20 mm 183 25 mm 184 32 mm 185 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 186 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required 187 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 188 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 189 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 190 12 way, Double door 191 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 192 4 way (4 + 12), Double door 193 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 194 Single pole 195 Double pole 196 Triple pole 197 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 198 Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 199 8 - 10 watt 200 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 201 18- 22 watt 202 Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 203 100 watt 204 Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 205 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)

Key Value

Document Fees
INR 5000 /-
EMD
INR 183560.0 /-
Tender Value
INR 91.78 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail