Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-10-2025 | Date Extension | Date | 27-10-2025 |
| 2 | 16-10-2025 | Corrigendum 1 | Technical Bid | 22-10-2025 |
| Sl. No. | Item Description |
| 1 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 2 | Excavation for roadway in earth soil of all sorts, sand, gravel or soft murum including dressing section to the required grade camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 mand spreading for embankment or stacking as directed. |
| 3 | Excavation for roadway in soft rock including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 mand spreading or stacking as directed. |
| 4 | Conveying materials obtained from road cutting including all lifts, laying in layers of 20 cm. to 30 cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than97% of standard proctor density for a lead of over 300 m to 500 m. inclusive from the site of excavation to the site of deposition as directed. |
| 5 | Construction of granular sub-base by providing close graded Material,spreading in uniform layers with Motor Grader/ Paver on prepared surface, mixing by mix in place method with rotavator at Optimum Moisture Content and compacting with vibratory roller to achieve the desired density complete as per clause 401. For Grading I Material. |
| 6 | Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0 BHP pump etc. complete. (Prior approval of Superintending Engineer will be necessary) |
| 7 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting, dewatering etc. complete (lift upto 1.5 m)by Mechanical Means. |
| 8 | Filling in plinth and floors with approved excavated materials in 15 cm to 20 cm layers including watering & compaction complete. |
| 9 | Filling in plinth and floors with contractorsmaterial/ brought from outside and approved by Engineer inchargein layers of 15 centimetre to 20 centimetreincluding watering and compaction etc. complete.Spec. No. : Bd.A. 11/Page No. 263 |
| 10 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade). |
| 11 | Providing and laying in situ cement concrete M-30 with tremix treatment for 200milimetrethickness for Concrete Road including laying plastic sheet of 125 micron with groove cutting of 4milimetrewide and 20milimetredeep, with necessary refilling with Refilling with Polysulfide Sealent (pouring Grade) conforming to BS:5212-1989 into sawed groove widened at topfor sealent reservoir of specified size and shape as per detailed drawing including fixing polyethylene foam backer road of required diameter(excluding reinforcement) with course and fine agreegates using VSI quality artificial sand etc. complete. |
| 12 | Providing, cutting, bending, hooking, tyingand laying in position TMT FE 500 steel bars for reinforcement for all RCC works as per detailed drawings etc. complete. |
| 13 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 m.) by Mechanical Means. |
| 14 | Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 80 milimetre thick in M-40 grade of approved size and shape for city streets, small /medium market roads,low volume roads, utility cuts on arterial roads etc. as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of natural sand /crushed sand of 50 milimetre thickness including necessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibratoretc. complete. |
| 15 | Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb without gutter (as per IRC:86-1983) embedded 125 mm below ground level over M-10 P.C.C. finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff anywhere in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant. |
| 16 | Providing and laying of hot applied thermoplastic compound 2.50 milimetre thick including reflectorizing glass beads at 250 grams per square metre area, thickness of 2.50 milimetre is exclusive of surface applied glass beads as per Indian Road Congress:35. The finished surface to be level, uniform and free from streaks and holes complete. |
| 17 | SupplyingandFixing of Molded Shank Raised Pavement Markers/ Cat\"s Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kilogram tested in accordance to ASTM D 4280 Type H and complying to specifications of Category A of MORTH Circular NumberRW/NH/33023/10-97 – DO III Dated 11-06-1997. The height, width and length shall not exceed 50 milimetre, 100 milimetre and 102 +/- 2 milimetre and with minimum reflective area of 13 square centimetre on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 milimetre and height not less than 30+/- 2 milimetre) from the body is to be a minimum value of 500 Kgf. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 18 | Providing and applying two coats of flat oil paint of approved colour and shade to internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. |
| 19 | Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600 mm diamade out of 3mm aluminum composite material ( ACM) sheet bonded with white retro reflective sheeting ofClass B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. ofM. S. angle iron post of size65 mm X 65 mm X 6 mm, 3.45 m long,duly paintedwithwith flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warrantyfrom the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificatein original should be submitted to the Engineer in charge by the contractor/supplier. |
| 20 | Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600 mmmade out of 1.5mm aluminum sheet bonded with white retro reflective sheeting ofClass B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. ofM. S. angle iron post of size65 mm X 65 mm X 6 mm, 3.45 m long,duly paintedwithwith flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warrantyfrom the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificatein original should be submitted to the Engineer in charge by the contractor/supplier. |
| 21 | Providing and fixing of retro-reflectorised informatory sign board Rectangular/ Squarein shape having area greater than 0.9 square metremade out of 4 mm. Aluminum Composite Material (ACM)bonded with white retro reflective sheeting bonded with white retro reflective sheeting of Class C (Type XI micro-prismatic grade sheeting) having pressure sensitive/ heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012, Table No 8.3, supportedwith back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one number of M.S. angle iron post of size75 mm. X 75 mm. X 6 mm., 3.5 m. long, firmly fixed to the ground by means of properly designed foundation with M-25 grade cement concrete 45 cm. x 45 cm. x 60 cm., 60 cm. below ground level as per approved drawing The angle iron postshall be duly painted with one coat of epoxy primer and two coats of epoxy finish paint having alternate black and white bands of 25 cm. width including G.I. fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class C (Type XI micro-prismatic grade sheeting) shall have 10 years written warrantyfrom the manufacturer and authorised distributor/ convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificatein original should be submitted to the Engineer in charge by the contractor/ supplier. |
| 22 | Providing and laying in situ/ Ready Mixcement concrete M-25of trap/ granite/quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/ pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). |
| 23 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). |
| 24 | Providing and laying Weep Holes of 100 mm diameter AC/ PVC pipes as per drawing for abutment returns, return walls etc. Complete. |
| 25 | Providing and laying cement concrete pipe of I.S. 458:2003 non pressure-2 classof 450 milimetrediameterin proper line, level and slope including providingandfixing collars in cement mortar 1:2 complete. |
| 26 | Providing and laying cement concrete pipe of I.S. 458:2003 non pressure-2 classof 600 milimetrediameterin proper line, level and slope including providingandfixing collars in cement mortar 1:2 complete. |
| 27 | Providing and laying cement concrete pipe ofIndian Standard458:2003 non pressure-2 classof 800 milimetrediameterin proper line, level and slope including providingandfixing collars in cement mortar 1:2 complete. |
| 28 | Providing fly ash brick masonary with conventional / I.S. type fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, strikingjoints, racking out joints, watering and scaffolding complete. |
| 29 | Providing Silica plaster plaster externally in two coats in all positions including base coat of 8 to 10 mm thick curing the same for not less than two days and keeping the surface of base coat rough to receive the final coat treatment 5 to 7 mm thick .finishing the surface by taking out grains and curing for 8 to 10 daysscaffolding etc complete.(The silica plast material shall contain 53 grade OPC cement with pozzolanic materials .size of agreegates shall be of 3 mm having 1:3 proportion with cement. |
| 30 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. |
| 31 | Providing & constructing Brick Masonry Inspection Chamber 60 cm x 45 cm x 90 cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half roundGlazedStone Ware pipes, Brick Masonry, plastering from inside and airtight C. I.cover of 75 Kg with lid and frame fixed in cement concrete etc. complete. |
| 32 | Providing & constructing Brick Masonry Inspection Chamber 90 cm x 45 cm x 90 cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round GlazedStone Warepipes, Brick Masonry,plastering from inside andC.I. lid 75 Kg with frame fixed in cement concrete etc. complete.. |
| 33 | Providing & constructing Brick Masonry Inspection Chamber 60 cm x 45 cm x 90 cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round GlazedStone Warepipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. cover medium duty 140 kilogram with frame etc. complete. |
| 34 | Providing & constructing Brick Masonry Inspection Chamber 90 cm x 45 cm x 90 cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round GlazedStone Ware pipes, Brick Masonry, plastering from inside andwith frame fixed in cement concrete with R.C.C. cover medium duty 140 kilogram with frame etc. complete. |
| 35 | Providing and Layingof Rumble strips with Plastirib 2K, or equivalent 2 component cold plasticprofiled material to give total width of 500 mm and height of 10 mm. Ramp providedto give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm.The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 36 | Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.50 m)by Mechanical Means.. |
| 37 | Providing uncoursed rubble masonary oftrap stones in cement mortar 1:6 in foundations and plinth of inner walls/in plinth of external walls including bailing out water manually, striking joints on exposed faces and watering complete. |
| 38 | Providing and laying Cast in situ/ Ready Mix cement concrete M-15 of trap/ granite/ quartzite/ gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed). With fine aggregate (Crushed sand V.S.I. Grade). (Ground Floor) |
| 39 | Providing patti/ band 150 mm. wide on plastered surface 12 mm. to 15 mm. thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.( Ground Floor) |
| 40 | Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm. thick in C.M. 1:4 and rough cast treatment 12mm. thick in proportion 1:1.5:3 including scaffolding and fourteen days curing complete.(Ground Floor) |
| 41 | Providing flush grooved pointing with cement mortar 1:3 for stone masonry work including scaffolding and curing etc. complete.( Ground Floor) |
| 42 | Providing tuck pointing with cement mortar 1:3 for stone/ brick masonry including scaffolding and curing etc. complete. |
| 43 | Providing and fixing in position TMT FE -500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.(Ground Floor) |
| 44 | Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.(First Floor) |
| 45 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. |
| 46 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.(Ground Floor) |
| 47 | Providing and laying cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). (Ground Floor) |
| 48 | Providing and laying cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). (First floor) |
| 49 | Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/quartzite/ gneiss metal for R.C.C. Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). ( Ground Floor) |
| 50 | Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/quartzite/ gneiss metal for R.C.C. Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). (First Floor) |
| 51 | Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Slabs and Landingsas per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). ( Ground Floor) |
| 52 | Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Slabs and Landingsas per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). ( First Floor) |
| 53 | Providing fly ash brick masonary with conventional /IndianStandard type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete.(Ground Floor) |
| 54 | Providing fly ash brick masonary with conventional / I.S. type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete.( First Floor) |
| 55 | Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mmdiameter/ two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking joints and watering etc. complete.( Ground Floor) |
| 56 | Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mmdiameter/ two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking joints and watering etc. complete.( First Floor) |
| 57 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm. thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.( Ground Floor) |
| 58 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ B.B.masonry and or tying by binding wire etc. complete.( Ground Floor) |
| 59 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ B.B.masonry and or tying by binding wire etc. complete.( First Floor0 |
| 60 | Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coats using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.(Ground Floor) |
| 61 | Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.(Ground Floor) |
| 62 | Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.( First Floor) |
| 63 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12 mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1kg/ per bag of cement laying brick bat coba ofrequired thickness in cm 1:5 with waterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20 mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/ per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years\" guarantee on requisite stamp paper including curing etc. complete.(Ground Floor) |
| 64 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg. per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. |
| 65 | Providing and laying vitrified matt fininsh tiles for flooring having size 590 mm to 605 mm x to 605 mm. of 8 to 10 mm. thickness and confirming I.S. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.( Ground Floor) |
| 66 | Providing and laying vitrified matt fininsh tiles for flooring having size 590 mm to 605 mm x to 605 mm. of 8 to 10 mm. thickness and confirming I.S. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.( First Floor) |
| 67 | Providing and laying ceramic tiles having size 30 cm. x 60 cm. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.( Ground Floor) |
| 68 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for plain or molded sills, cornice, jambs, block in course, or architraves of required size and shapes including steel centering, plywood/ steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided,finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.)with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade). (First Floor) |
| 69 | Providing and laying telephone black/ Amba White/ Cadburybrown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.(Ground Floor) |
| 70 | Providing and laying telephone black/ Amba White/ Cadburybrown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.(First Floor) |
| 71 | Providing and fixing fibre glass reinforced polyster door shutter 30 milimetre thick as per IS 14856 (2000) (reaffirmed 2006 ) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, complete.(Ground Floor) |
| 72 | Providing and fixing fibre glass reinforced polyster door shutter 30 mm. thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc. complete.(First Floor) |
| 73 | Providing and fixing in position powder coated aluminium louvered windows/ ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. ( Ground Floor) |
| 74 | Providing and laying Cast in situ/ Ready Mix cement concrete M-15 of trap/ granite/ quartzite/ gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed). With fine aggregate (Crushed sand V.S.I. Grade). (First Floor) |
| 75 | Providing and Fixing mat finish stainless steel (of 302 grade) railing with toppipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use).(Ground Floor) |
| 76 | Providing and Fixing mat finish stainless steel (of 302 grade) railing with toppipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use).( First Floor) |
| 77 | Providing and laying chequered tiles of approved qualityof size 30 cm. x 30 cm. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.(Ground Floor) |
| 78 | Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate fall ceiling (like aeroltie) of approved texture spintone/ cosmos/ hexa or equivalent of size 595 mm x 595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main “T” runner suitably spacedat joints to get required length and size 24x38mm. made from 0.33 mm thick(minimum ) sheet, spaced 1200 mm center to center and cross “T” of size 24x28mm made of0.33 mm thick (minimum ) sheet to be interlocked at the middle of the 1200 x 600 mm panel to form the grid of size 600 x 600 mm resting on periphery walls/ partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450 mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa)in the grid, including light fittings, fixtures, smokedetectors etc., whereverrequired. Main “T” runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5 mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main “T” bottom exposed with 24 mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete.(currently this item should be used only for VIP cabins).(Ground Floor) |
| 79 | Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate fall ceiling (like aeroltie) of approved texture spintone/ cosmos/ hexa or equivalent of size 595 mm x 595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main “T” runner suitably spacedat joints to get required length and size 24x38mm. made from 0.33 mm thick(minimum ) sheet, spaced 1200 mm center to center and cross “T” of size 24x28mm made of0.33 mm thick (minimum ) sheet to be interlocked at the middle of the 1200 x 600 mm panel to form the grid of size 600 x 600 mm resting on periphery walls/ partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450 mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa)in the grid, including light fittings, fixtures, smokedetectors etc., whereverrequired. Main “T” runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5 mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main “T” bottom exposed with 24 mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete.(currently this item should be used only for VIP cabins).(First Floor) |
| 80 | Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture “aerolite” make or equivalent of size 595mm x 595mm having 15 mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46 part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600 x600 mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main “T” runner of size 42 mmx14 mm between main \"T\" 600 mm center-tocenter and secondary cross “T” of size 33x14x0.43 mm thick of length 600 mm long spaced inter-locked at middle of the first crossed “T” in each panel to form grid of 1200 mmx600 mm resting on periphery wall Profile wall section 19mm (7+7) x 19 mm x 0.40 thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, smokedetectors etc., whereverrequired. Main “T” runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6 mm dia and 50 mm long dash fastener, 4 mm dia. G.I. adjustable rods with powder-coated/ good quality G.I. level adjustment clips of 35x35x0.8 mm spaced @1200, center-to-center along main “T” all complete at all heights as per the specifications, drawings and as per the directions of Engineer-in-charge. (Ground Floor) |
| 81 | Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture “aerolite” make or equivalent of size 595 milimetre x 595 milimetre having 15milimetre thick densified micro look edge and 100 percent humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600 x 600 milimetre made from hot dippedGalvanised Ironsteel sections ion silhouette profile, rotary stitched double webbed white with 6 milimetre reveal profile (white/black), wherein, main “T” runner of size 42 milimetre x 14 milimetre between main \"T\" 600 milimetre center-tocenter and secondary cross “T” of size 33 x14 x0.43milimetre thick of length 600 milimetre long spaced inter-locked at middle of the first crossed “T” in each panel to form grid of 1200 milimetre x 600 milimetre resting on periphery wall Profile wall section 19 milimetre (7+7) x 19 milimetre x 0.40 thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, smokedetectors, whereverrequired. Main “T” runners suspended from ceiling with using Galvanised Ironsoffit cleats of size 25x35x1.6 milimetre of required length fixed to the ceiling with 6 milimetre diameter and 50 milimetre long dash fastener, 4 milimetre diameter Galvanised Ironadjustable rods with powder-coated/good quality Galvanised Ironlevel adjustment clips of 35x35x0.8 milimetre spacedat 1200, center-to-center along main “T” all complete at all heights as per the specifications, drawings and as per the directions of Engineer-in-charge. (First Floor) |
| 82 | Providing and fixing on walls /ceiling /floor 15 milimetrediameterCPVC pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedcomplete. |
| 83 | Providing and fixing on walls /ceiling /floor 25 milimetrediameterCPVC pipe with necessary fittings, remaking good the demolished portion.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 84 | Providing and fixing on walls /ceiling /floor 50milimetrediameterCPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. |
| 85 | Providing and fixing P.V.C. Rain water pipes of 160 mm outerdiameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 mm to 40 mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment) |
| 86 | Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall, 100 mmdiameterG.I. plug bend inlet pipe all fittings, cutting and making good walls, floors etc. complete. |
| 87 | Providing and fixingOval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetresize withpillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap ofnecessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180milimetrethick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. |
| 88 | Providing and fixing 10 cm C.I. Nahani Trap including C.I. grating ,bend and piece of C.I. pipe upto the outside face of the wall complete. |
| 89 | Providing and fixing white glazed urinal of serieswith Pressmatic auto closing valve of having32 milimetrediameter P.V.C. flush pipe with fitting and flushing of approvedmake andarrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. |
| 90 | Providing and fixing 50mmdiameterwater meter with non return valve including strainer,sockets/ union nut and including water meter box making locking arrangement and lock. [ without chamber ] |
| 91 | Providing and fixing 15 milimetrediameterscrew down bib/ stop tap of brass including necessary socket union nut complete. |
| 92 | Providing and fixing 450 mm.x550 mm. size superior type Belgium mirror with 16 mm diameter nickel plated towel rod etc. complete. |
| 93 | Providing and fixing 75 mmdiameterstabiliser pipe/P.V.C. soil vent/ waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps etc. complete. |
| 94 | Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles ofium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.(Ground Floor) |
| 95 | Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 1000 to 20000 liters.( Ground Floor) |
| 96 | Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BARof IZE-600MM (H) X600MM (D) and 32MM DIA. and thicknessmm of the approved brand and make.27c) Straight grab bar (2 NOS)Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make.( Ground Floor) |
| 97 | Providing and fixing partition with kadappa stone of all sizes and 25 mm thick polished on both side and edges to original including fixing in position in cement mortar 1:4 curing polishing, cleaning etc. complete.(Ground Floor) |
| 98 | Providing and fixing 15 cm x 10 m salt glazed stoneware gully trap in cement concrete 1:4:8 out side the building including cast iron grating in the sink, connecting glazed stonewre pipe brick masonry chamber with cast iron lid and cast iron grating for the gully trap. |
| 99 | Providing, laying & fixing, jointing Eco-drain 110 mm SN 8 Nu-Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler etc. jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. |
| 100 | Providing, laying & fixing, jointingEco-drain 160 mm SN 4 Nu-Drain UPVC pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc. jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. |
| 101 | Providing, layingandfixing, jointing Eco-drain 200 milimetre SN 4 Nu-Drain Unplasticised Poly Venyl Chloride pipes or of equivalent make, manufacture as per EN 13476 or equivalent as perIndian Standard 15328 with fittings such a bends, tees, coupler, etc. jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material complete. |
| 102 | Providing, laying & fixing, jointing Eco-drain 250 mm SN 4 Nu-Drain UPVC pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 and 16098 with fittings such a bends, tees, coupler, etc. jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. |
| 103 | Providing and laying cement concrete pipe of I.S. 458:2003 non pressure-2 classof 450 milimetrediameterin proper line, level and slope including providingandfixing collars in cement mortar 1:2 complete. |
| 104 | Providing and fixing in position UPVC ultra violet stabilized 110 mm outerdiameter cowl dome confirming to I.S. 4985 including making joints with solvent cement etc. complete. |
| 105 | Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles ofium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.(First Floor) |
| 106 | Cutting down trees including trunks and branches with girths above 30 cm. to 60 cm. and stacking the material neatly with all lifts and lead of 1000 m as directed and earth filling in the depression/pit if any. |
| 107 | Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 metre)by Mechanical Means. |
| 108 | Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 m to 3.0 m)by Mechanical Means. |
| 109 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5m To 3.0 m)by Mechanical Means. |
| 110 | Excavation for foundation in Hard-rock by blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/ murum watering, ramming etc. complete, (Lift from 1.5m To 3.0 m)by Mechanical Means. |
| 111 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. |
| 112 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper. |
| 113 | Providing drytraprubble stone soling 15cm to 20cm thick including hand packing and compacting complete. |
| 114 | Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Ground Floor) |
| 115 | Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (First Floor) |
| 116 | Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.(Ground Floor) |
| 117 | Providing internal cement plaster 12 mm. thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.( First Floor) |
| 118 | Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and finishing the surface scaffolding etc. complete.( Ground Floor) |
| 119 | Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and finishing the surface scaffolding etc. complete.( First Floor) |
| 120 | Providing and applying plaster with plaster of paris in 6mm. thickness to previously plastered surface in all position including preparing the surface scaffolding etc. complete.(Ground Floor) |
| 121 | Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Rubyred/ Ocean Brown granite stone of approved shade and size 18 mm. to 20 mm. thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar1:3 curing and cleaning etc. complete.( Ground Floor) |
| 122 | Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Rubyred/ Ocean Brown granite stone of approved shade and size 18 mm. to 20 mm. thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar1:3 curing and cleaning etc. complete.( First Floor) |
| 123 | Providing and laying vitrified matt finish tiles for Skirting having size 590 mm. to 605 mm. x to 605 mm. of 8 to 10 mm thickness and confirming I.S. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. ( Ground Floor) |
| 124 | Providing and laying vitrified matt finish tiles for Skirting having size 590 mm. to 605 mm. x to 605 mm. of 8 to 10 mm thickness and confirming I.S. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. (First Floor) |
| 125 | Providing and fixing machine cut machine polished 18 milimetreto 20 milimetrethick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaningetc. complete.( Ground Floor) |
| 126 | Providing and fixing machine cut machine polished 18 mm. to 20 mm. thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaningetc. complete.( First Floor) |
| 127 | Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc.complete.( Ground Floor) |
| 128 | Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc.complete.( First Floor) |
| 129 | Providing and laying polished Kotah stone flooring 25mm to 30mm thick & of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete.(Ground Floor) |
| 130 | Providing and laying polished Kotah stone flooring 25mm to 30mm thick & of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete.(First Floor) |
| 131 | Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. (Ground Floor) |
| 132 | Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. (First Floor) |
| 133 | Providing and laying vitrified mirror / glossy finish tiles forSkirting having size 590 mm to 605 mm. x 590 mm. to 605 mm. of 8 to 10 mm. thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete.( Ground Floor) |
| 134 | Providing and laying vitrified mirror / glossy finish tiles forSkirting having size 590 mm to 605 mm. x 590 mm. to 605 mm. of 8 to 10 mm. thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete.( First Floor) |
| 135 | Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete. (Ground Floor) |
| 136 | Providing and fixing frame with/ without ventilator of size as specified with country cutteak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 mm x 40 mm x 5 mm with oil painting, etc.complete. (First Floor) |
| 137 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (Ground Floor) |
| 138 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (First Floor) |
| 139 | Providing and fixing solid core flush door shutter in double leaf 32milimetrethick decorative type of exterior grade as per detailed drawings approved face veneers 3milimetrethick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.(Ground Floor) |
| 140 | Providing and fixing solid core flush door shutter in double leaf 32milimetrethick decorative type of exterior grade as per detailed drawings approved face veneers 3milimetrethick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (First Floor) |
| 141 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm. with lock plate of 3.15 mm. thickness reinforced with 35 x 35 x 5 mm. angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm. and 3.15 mm. respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm. minimum size and shape with square bar, suspension shaft of minimum 32 mm. diameter, hood cover of M.S. sheet not less than 0.9 mm. thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 6248-1979) (With mechanical gear) ( Ground Floor) |
| 142 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm. with lock plate of 3.15 mm. thickness reinforced with 35 x 35 x 5 mm. angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm. and 3.15 mm. respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm. minimum size and shape with square bar, suspension shaft of minimum 32 mm. diameter, hood cover of M.S. sheet not less than 0.9 mm. thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 6248-1979) (With mechanical gear) (First Floor) |
| 143 | Providing & fixing factory-made Single leaf 2 hour fire rated dooras per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer and Flush bolts complete. (Ground Floor) |
| 144 | Providing & fixing factory-made Single leaf 2 hour fire rated dooras per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer and Flush bolts complete. (First Floor) |
| 145 | Providing and fixing in position (as per I.S.1868:1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 milimetreat weight 0.547 kilogram per running metre and window frame bottom track section 61.85 x 31.75 x 1.20 milimetreat weight 0.695 kilogram per running metre.Top and side track section 61.85 x 31.75 x 1.30 milimetreat weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetreat weight 0.417 kilogram per running metre. Inter locking section 40 x 18 x 1.10 milimetreat weight 0.469 kilogram per running metreand handle section 40 x 18 x 1.25 milimetreat weight 0.417 kilogram per running metreand top section 40 x 18 x 1.25 milimetreat weight 0.417 kilogram per running metreAs per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetrethick plain glass with all required screws and nuts etc, complete with powder coating without box.(Ground Floor) |
| 146 | Providing and fixing in position(as per I.S. 1868/1982) aluminiumsliding window of two tracks with powder coating without box with rectangular pipe 63.50 x 38.10 x 1.02 mm at weight 0.547 Kg/Rmt.and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kg/Rmt. Interlocking section 40 x 18 x 1.10 mm at weight 0.469 Kg/Rmt. and handle section 40 x 18 x 1.25 mm at weight 0.417 Kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 Kg/Rmt. as per detailed drawing and as directed by Engineer -In-Charge with all necessary aluminiumsection fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5mm thick plain glass with all required screws and nuts etc complete ( First Floor) |
| 147 | Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm. at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm. at weight 1.070 kg/Rmt. Top and side track section 92 x 31.75 x 1.30 mm. at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm. at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm. at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm. thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating without box.( Ground Floor) |
| 148 | Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm. at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm. at weight 1.070 kg/Rmt. Top and side track section 92 x 31.75 x 1.30 mm. at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm. at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm. at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm. thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating without box.( First Floor) |
| 149 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg./sq.m.as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.( Ground Floor) |
| 150 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg./sq.m.as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.(First Floor) |
| 151 | Providing and fixing 40 mmdiameter and 1.5 mm thick stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete. (Ground Floor) |
| 152 | Providing and fixing 40 mmdiameter and 1.5 mm thick stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete. (First Floor) |
| 153 | Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards,screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.(Ground Floor) |
| 154 | Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards,screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.(First Floor) |
| 155 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm. thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.( GroundFloor) |
| 156 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm. thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.( First Floor) |
| 157 | Providing & applying washable oil bound distemper of approved colour and shade to old & new surfaces in two coats including scaffolding, preparing the surfaces.(excluding the primer coat.) complete.( Ground Floor) |
| 158 | Providing & applying washable oil bound distemper of approved colour and shade to old & new surfaces in two coats including scaffolding, preparing the surfaces.(excluding the primer coat.) complete.( First Floor) |
| 159 | Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete.(Ground Floor) |
| 160 | Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete.( First Floor) |
| 161 | Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface ,including Plaster Groove 6 mm. thickness or Tape Grooves 35 to 45 mm. thickness or as required, in all position including preparing the surface scaffolding etc. complete.( Ground Floor) |
| 162 | Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface ,including Plaster Groove 6 mm. thickness or Tape Grooves 35 to 45 mm. thickness or as required, in all position including preparing the surface scaffolding etc. complete.( First Floor) |
| 163 | Providing and laying Cast in situ/ Ready Mix cement concrete inMix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic ControllerwithSuperwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ).( Ground Floor) |
| 164 | Providing and laying Cast in situ/ Ready Mix cement concrete inM-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ).( First Floor) |
| 165 | Designing, providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of Integrated Wetland Technology (IWT)based Sewage Treatment Plant (STP) consisting of Screen chamber, Oil& Grease trap, RCC Primary treatment tanks (including manholes, vent pipes and graded gravel media) and RCC Secondary treatment tanks (SBBR) (including gravel media, PVC sheets,wetland plants, plastic mesh, etc. as required.)tank, RCC intermediateand treated watertank, sludge recirculation pump and pipe network, room for tertiary treatment unit, E&M works for tertiary treatment includingassociated piping work, internal pathways, wire fencing, etc. complete as turnkey job with all involved civil, electrical and mechanical works inclusive of following items, units as per detailedspecifications for civil, electrical and mechanical components with all duties and taxes, etc. complete as directedby Engineer-In-charge. Allied structure shall be constructed as per the provision in appropriate and relevant standards and design guidelines of respectiveauthorities. RCC and civil works will be as directedby Engineer-in-charge. Sewage Treatment Plant (STP) to be designed to treat the row water sewage with the characteristics in table number\"A\" to produce the treated sewage with characteristics as mentioned in table number \"B\"Raw Sewage CharacteristicsTemperature - AmbientpH - 5.5-9.0BOD5 - 300 mg/LCOD - 600 mg/LFOLLOWING COMPONENTS ARE INCLUDED :1. SCREEN CHAMBER:2. Oil and Grease Trap3. Primary Treatment Tank4.Static Bed Biofilm Reactor (SBBR)5. Intermediate and Treated Water Tank6. Tertiary Treatment Unit7. Treated Water Outfalls |
| 166 | Designing (aesthetically), providing, fabricating Package Water Treatment Plant at the shop, transporting to site, installing, testing and commissioning at the site, giving necessary one month\"s free test and trail run with guarantee for oneyear, etc. complete. Prefabricated Package Water Treatment Plantcomprising following : 1.Rapid mixing channel in M.S. sheets and M.S. baffle.2.Flocculator not less than 10 minutes detention, in M.S. prefabricated box, flocculation being achieved either by glass pebbles of graded size or PVC tetrapod orequivalent arrangement to ensure good floc formation. 3. Plate or tube settlers of not less than 30 minutes detention in M.S. prefabricated box, the plates / tubesmounted in the settler basin with inclination of not less than 60 degree to horizontal. 4.Rapid sand gravity filter in M.S. prefabricated box withfilter sand not less than 500 mm thick, supported onfalse floor below with polypropylene nozzles spaced atnot more than 500 mm centres in either direction. 5.Backwashing, inlet & outlet facilities shall be provided. 5.1Air blowers - Air Blowers are not required for WTPhaving capacity less than and equal to 3 MLD, for WTPhaving capacity more than 3 MLD air blowers capacityof delevering 600 LPM per sqm of free air of filter area0.4 kg/sqcm at underdrain(100% standby)5.2Wash water tank capacity equal to 2 % of designedquantity of filer water in a day + 10 %5.3wash water pump with 100 % standby (Minimum 3 HPwith all accessories) 5.4Backwash with water not less than 0.6 cum/sqm of filterbed area in filter box. 5.5 Piping of outlet upto sump6) Laboratory equipments7) Extemal & Internal electrification8) TCL solution tank with mixing, carrying and dosing arrangement with piping9) Gravity feed gas chlorinator with 100% standby.10) Four alum storage unit11) Drainage arrangement12) Providing room with RCC roof for office and Lab space with necessary water supply & drainage arrangement & internal roads13) RCC sump of one hour cap and pump house on it14) Intemal Road15) Wire fencing with gate for WTP premises.16) All civil works for foundation, consisting of raised RCC platform above G.L. or walls in B.B. masonry or UCR masonry shall be provided as per needs at site.17) Bypass in the form of pipes or M.S. channels included in the design, effecting bypass of such new tank and filter individually or both. (Limit upto 5.0 M. from W.T.P. face)18) The entire MS. fabricated tank provided with FRP lining (5 mm thick) to inside face in contact with water epoxy painting-two coats with one coat of primer on outside. The thickness of plates employed shall not be less than 6mm19) Alum dosing and mixing arrangements to be provided in twin tanks, each of 8 hours capacity, capable of importing does of 20 ppm with 5% solution. The alum tanks provided with a dose in steps of 5 ppm and entire unit mounted on the top of flocculator/settler box, in the form of prefabricated structure, with access platform and ladder. Alum boxes with FRP lining (5 mm thick) inside and epoxy paint two coats with one coat of primer on outside20) Both flocculator and setting basins provided with hopper bottom with slope not less than 45 degrees to the horizontal drain pipes and valves provided to both flocculator and settling basin.21) Flow ratings to conform following parametersa) Velocities in channels not to exceed 0.8 M. Secondb) Velocities in filter outlet pipes and valves not to exceed 1 M. Secondc) Velocities in interconnecting pipe and controls not to exceed 1M/Secondd) Backwash with air: Not required.e) Backwash with water: Not less than 0.6 M/Sqm. of filter bed area in filter box23) Free board for all units not less than 300 mm23) Rates as above include all taxes, octroi and duties which would be specific to the site locations |
| 167 | Providing and fixing interior wall to wall expansion joint cover model W90 for 50 mm gap size, this surface mounted aluminium cover is designed for interior application where low maintenance is desirable. This model is made using Aluminium alloy 6063 and temper T5/T6. This cover is installed using stailness steel clip in the rear which helps the movement to +10 mm ( Ground Floor) |
| 168 | Providing and fixing interior wall to wall expansion joint cover model W90 for 50 mm gap size, this surface mounted aluminium cover is designed for interior application where low maintenance is desirable. This model is made using Aluminium alloy 6063 and temper T5/T6. This cover is installed using stailness steel clip in the rear which helps the movement to +10 mm( First Floor) |
| 169 | Providing and fixing of external wall to wall cover model ASM 200X for 50 mm gap size, this surface-mounted metal wall cover is designed for exterior applications where low maintenance or tamper-resistant applications are desired. The free-floating aluminum center plate spans the joint and slides over the surface of the wall to allow required movement EPDM vapor barrier to protect the joint with water. This profile is extruded aluminum with ASTM B 221, Alloy 6063-T5. This profile has been tested under Architectural Testing Agency (an Intertek Company) for the movement performance. The minimum opening of the profile is 10mm (40mm) and the maximum openeing of the profile is 76mm (+26mm) which is more than 50% movement( Ground Floor) |
| 170 | Providing and fixing of external wall to wall cover model ASM 200X for 50 mm gap size, this surface-mounted metal wall cover is designed for exterior applications where low maintenance or tamper-resistant applications are desired. The free-floating aluminum center plate spans the joint and slides over the surface of the wall to allow required movement EPDM vapor barrier to protect the joint with water. This profile is extruded aluminum with ASTM B 221, Alloy 6063-T5. This profile has been tested under Architectural Testing Agency (an Intertek Company) for the movement performance. The minimum opening of the profile is 10mm (40mm) and the maximum openeing of the profile is 76mm (+26mm) which is more than 50% movement( First Floor) |
| 171 | Providing and fixig of floor to floor expansion joint cover GFT 200 for 50 mm gap size. The cover which is designed for interior floor to floor application suitable for most floor finishes where frame depth and configuration is variable to suit selected finish. It is a gasketed floor to floor joint cover comprises of extruded aluminium frames made of aluminium alloy 6063 temper T5/T6 and TPR seal having strength of 90 shore A as per ASTM D2000 and available in 4 colours, with standard loading capacity of 500 lbs. The nominal joint width of the profile is 51 mm which contracts down to 38 mm as minimum and can expand 64 mm as maximum, the movement has been tested with Architectural testing INC., an Intertek company (Intertek ATI) as per ASTM E 1399-97( Ground Floor) |
| 172 | Providing and fixig of floor to floor expansion joint cover GFT 200 for 50 mm gap size. The cover which is designed for interior floor to floor application suitable for most floor finishes where frame depth and configuration is variable to suit selected finish. It is a gasketed floor to floor joint cover comprises of extruded aluminium frames made of aluminium alloy 6063 temper T5/T6 and TPR seal having strength of 90 shore A as per ASTM D2000 and available in 4 colours, with standard loading capacity of 500 lbs. The nominal joint width of the profile is 51 mm which contracts down to 38 mm as minimum and can expand 64 mm as maximum, the movement has been tested with Architectural testing INC., an Intertek company (Intertek ATI) as per ASTM E 1399-97( First Floor) |
| 173 | ITEM No.1: Drilling surface bore well 150mm dia. By DTH rig Machine,work (including transportation) (includes 150 mm diameter reaming drilling in clay/sand strata and 115 mm diameter drilling in hard rock (wet drilling) etc.completeSpec. No.: As directed by Engineer-in-chargeGWSDA Rate For Year 2024-25 |
| 174 | ITEM No.2: Providing and fixing P.V.C. casing pipe 180 mm dia. etc.complete (6 Kg./Sq.Cm.) (IS 4985-1988)Spec. No.: As directed by Engineer-in-chargeGWSDA Rate For Year 2024-25 |
| 175 | ITEM No.3: Lowering and grouting P.V.C. casing pipe 180 mm dia. etc.complete (6 Kg./Sq.Cm.) (IS 4985-1988)Spec. No.: As directed by Engineer-in-chargeGWSDA Rate For Year 2024-25 |
| 176 | ITEM No.4: Yeild testing by V noteches etc.completeSpec. No.:As directed by Engineer-in-chargeGWSDA Rate For Year 2024-25 |
| 177 | ITEM No.5: Providing & Fixing PVC Cap for 180 mm Casing Pipe etc.completeSpec. No.:As directed by Engineer-in-chargeGWSDA Rate For Year 2024-25 |
| 178 | ITEM No.6: Supplying and erecting submersible pumpset of 3.75 KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 20 to 80 LPM discharge at 258 to 118 m head & (max. efficiency at 190 m head & 50 lpm) discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification no. WP-SMPElectrical DSR 2020-21 I. No. 12-2-25 |
| 179 | ITEM No.7: Automatic Control Panel (12.4.17)Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.c. Submersible/centrifugal pump set upto 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosurewith IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc Electrical DSR 2020-21 I. No. 12-4-17 |
| 180 | ITEM No.9:Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.Electrical DSR 2020-21 I. No. 12-4-9 |
| 181 | ITEM No.11 Providing and supplying in standard lengths Polyethelene Pipes (HDPE) of 63 mm Dia (8Kg./Sq.cm.) including all local & central taxes, octrai, inspection charges, transportation to stores etc. complete. M.J.P. D.S.R.2021-2022 I.No.1A-b- i P.No.113 |
| 182 | ITEM No.12: Lowering,laying, jointing Providing and supplying in standard lengths Polyethelene Pipes (HDPE) 63 mm of Dia. including all labour cost, , transportation etc. complete. M.J.P. D.S.R.2021-2022 I.No.2-vi P.No. 115 |
| 183 | Providing Ashlar Masonry with Soft Compacted Basalt stone. First Sort like walls, columns, cap stones etc. with dressing as per drawing and as directed by Engineer-in-Charge, in cement mortar 1:4 with fitting joints (paper), setting with stainless steel dowels, pins and fixing with Araldite and hardner etc. including transportation and conveyance to specific required location, scaffolding, tools and tackels, racking the joints with neat cement slurry, curing cleaning etc complete. The stones shall be dressed full or to template, or as shown in working drawings. The exposed faces of the stone shall be fine-chissel dressed, and all joints shall be in line and close not more than 3mm thick. All visible angles and edges to be free from unsightly chippings, etc. complete. As directed by Engineer-In-Charge. (The sample of the moulded stone shall be approved prior to execution by Consultant/Engineer-In-Charge.) |
| 184 | Shingles on Roof Providing and fixing shingles on Roof of size 17 X10 mch to 11 1/4\" to 39 \"1/8 \"of asphalt The material are resistance against fire and atmospheric aggrestons and are developed using high quality material and cutting edge technology |
| 185 | GARDEN SOIL : Supplying on site gardensoil well sieved 90% to pass through I.S. sieve of 10 mm size free from stones rubbish like dried grass mots and other such materials. The soil should be fresh from qarry. The colour of the soil generally be red. The soil will be measured by measuring box .(Farma) (Item includes Royalty charges, Transporting, loading unloading etc.) lead charges for 20k.m. is considered |
| 186 | Preparing Lawn (30 cms.Depth) Excavating the ground to a required depth of 30 cms. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/silt & manure in excavated area in 3:1 proportion to a height of 30cms. Mixing garden soil and manure thoroughly, well, leveling, watering on previous night. Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping, rolling etc. complete |
| 187 | Providing Ashlar Masonry for Mural Molding at 4.522meter.Ht. with Soft Compacted Basalt stone. Size- 3357mm(W) x 4522mm (Ht.) x 450mm (L) Stone size 200mm x 330mm x 450mm with dressing as per drawing and as directed by Engineer-In-Charge, in cement mortar 1:4 with fitting joints (paper) including transportation and conveyance to specific required location, scaffolding, tools and tackels, racking the joints with neat cement slurry, curing, cleaning etc complete. The stones shall be dressed full or to template, or as shown in working drawings. The exposed faces of the stone shall be fine-chissel dressed, and all joints shall be in line and close not more than 3mm thick. All visible angles and edges to be free from unsightly chippings, etc. complete. As directed by Engineer-In-Charge. (The sample of the moulding stone shall be approved prior to execution by Consultant/Engineer-In-Charge.)For Building No. 29+30-ADB+PVB. Item Code-SM19 |
| 188 | Providing Ashlar Masonry for Mahirap Arch Molding at 4.067meter. Ht. with Soft Compacted type stone. Size-2267mm(W) x 1667mm (Ht.) x 300mm (L) stone size 300mm x 300mm x 450mm, with dressing as per drawing and as directed by Engineer-In-Charge, in cement mortar 1:4 with fitting joints (paper) including transportation and conveyance to specific required location, scaffolding, tools and tackels, racking the joints with neat cement slurry, curing, cleaning etc complete. The stones shall be dressed full or to template, or as shown in working drawings. The exposed faces of the stone shall be fine - chissel dressed, and all joints shall be in line and close not more than 3mm thick. All visible angles and edges to be free from unsightly chippings, etc. complete. As directed by Engineer-In-Charge. (The sample of the moulding stone shall be approved prior to execution by Consultant/Engineer-In-Charge.) |
| 189 | Providing Ashlar Masonry for Parapet Charya at 9.492meter.Ht. with Soft Compacted Basalt stone. Size-690mm(W)x1056mm (Ht.)x450mm thk. made out of 350mm x 350mm x 450mm 6 stones, with dressing as per drawing and as directed by Engineer-In-Charge, in cement mortar 1:4 with fitting joints (paper) including transportation and conveyance to specific required location, scaffolding, tools and tackels, racking the joints with neat cement slurry, curing, cleaning etc complete. The stones shall be dressed full or to template, or as shown in working drawings. The exposed faces of the stone shall be fine chissel dressed, and all joints shall be in line and close not more than 3mm thick. All visible angles and edges to be free from unsightly chippings, etc. complete. As directed by Engineer-In-Charge. (The sample of the moulding stone shall be approved prior to execution by Consultant/Engineer-In-Charge.)For Building No. 29+30-ADB+PVB. Item Code-PC1 |
| 190 | Providing Ashlar Masonry for Stone Moulding at 8.15 meter.Ht. with Soft Compacted Basalt stone. Stone Size-300mm(W)x300mm (Ht.)x450mm (L). with dressing as per drawing, and as directed by Engineer-In-Charge, in cement mortar 1:4 with fitting joints (paper) including transportation and conveyance to specific required location, scaffolding, tools abd tackels, racking the joints with neat cement slurry, curing, cleaning etc complete. The stones shall be dressed full or to template, or as shown in working drawings. The exposed faces of the stone shall be fine chissel dressed, and all joints shall be in line and close not more than 3mm thick. All visible angles and edges to be free from unsightly chippings, etc. complete. As directed by Engineer-In-Charge. (The sample of the moulding stone shall be approved prior to execution by Consultant/Engineer-In-Charge.) For Building No. 44-DVT. Item Code-SM40 |
| 191 | Providing and fixing FRP comice of specified length as per manufactures specificationHt.1.20m(As per drawing) The cost includes5 mm thick FRP, Pattern-mould, Fitting & Finishing Painting Loading & Unloading |
| 192 | Providing and fixing FRP cornice of specified length as per manufactures specification, HL0.45m(As per drawing) The cost includes5 mm thick FRP, Pattern- mould. Fitting & Finishing. Painting, Loading & Unloading |
| 193 | Providing Ashlar Masonry for 2.50m Level Moulding with Soft Compacted Basalt stone of size 300mm x 250mm x 150mm from approved source, with dressing as per drawing and as directed by Engineer-In-Charge in Cement Mortar 1:4 with paper fitting joints, including transportation and conveyance to specific required location, scaffolding, tools and tackles, racking the joints with neat cement slurry, curing, cleaning, etc. complete. The stones shall be dressed full or to template, or as shown in working drawings. The exposed faces of the stone shall be fine - chissel dressed, and all joints shall be in line and close not more than 3mm thick. All visible angles and edges to be free from unsightly chippings, etc. complete. As directed by Engineer-In-Charge. (The sample of the moulding stone shall be approved prior to execution by Consultant/Engineer-in-Charge. |
| 194 | Providing Ashlar Masonry for Parapet Charya at 10.674 meter. Ht. with Soft Compacted Basalt stone. Stone Size-690mm(W) x 1056mm (Ht.) x 450mm thk. made out of 350mm x 350mm x 450mm 6 stones, with dressing as per drawing andas directed by Engineer-In-Charge, in cement mortar 1:4 with fitting joints (paper) including transportation and conveyance to specific required location, scaffolding, tools and tackels, racking the joints with neat cement slurry, curing, cleaning etc complete. The stones shall be dressed full or to template, or as shown in working drawings. The exposed faces of the stone shall be fine chissel dressed, and all joints shall be in line and close not more than 3mm thick. All visible angles and edges to be free from unsightly chippings, etc. complete. As directed by Engineer-In-Charge. (The sample of the moulding stone shall be approved prior to execution by Consultant/Engineer-In-Charge.) |
| 195 | Providing Ashlar Masonry for Plinth Level Stone Moulding at 450mm. Ht. with Soft Compacted Basalt stone. Stone Size-310mm(W) x 245mm (Ht.) x 450mm (L) with dressing as per drawing and as directed by Engineer-in-Charge, in cement mortar 1:4 with fitting joints (paper) including transportation and conveyance to specific required location, scaffolding, tools and tackels, racking the joints with neat cement slurry, curing, cleaning etc complete. The stones shall be dressed full or to template, or as shown in working drawings. The exposed faces of the stone shall be fine chissel dressed, and all joints shall be in line and close not more than 3mm thick. All visible angles and edges to be free from unsightly chippings, etc. complete. As directed by Engineer-In-Charge. (The sample of the moulding stone shall be approved prior to execution by Consultant/Engineer-In-Charge.) |
| 196 | Providing and fixing soft compacted basalt stone of size 600L x470 D x 300 H mm size from approved source, for Carved Flower design (750mm x 750mm) at 6.85 m level embeded in Ashlar masonry, with dressing as per drawing and as directed by Engineer-In-Charge in cement mortar 1:4 with fitting joints (paper) including transportation and conveyance to specific required location, scaffolding, tools tackels racking the joints with neat cement slurry, curing cleaning varnishing etc complete. (The sample of the Mural stone shall be approved prior to execution by Consultant/Engineer-in-Charge.) As directed by Engineer-In-Charge. |
| 197 | Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg CCorrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mmBacteria immobilization PVC mattes (on all partition)With DRDO TOT licensee and latest batch certificate(month & year of supply) andcapacity as below.( First Floor) l) Up to 500 user size (6mx2.0mx1.6m), Capacity of Biodigester:-20000 liters, Area of top, bottom and side walls:- 50.72 sq.m, Area of partition walls: 13.36sq.m, Total weight of FRP:- 917.86 Kilogram, Bacteria inoculums quantity:- 7000 liters, Minimum thickness of side walls / top and bottom: 9 mm, One Number of inside partitions:- 4, Minimum thickness of partition wall: 4mm |
| 198 | SUB- WORK - NO-1 Providing Internal Electrification for Proposed Bhimashankar Large and Samll ST Bus Stand\"s campus,Nigdale Dist-PuneSupplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. 1-1-7 |
| 199 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (1-1-8) |
| 200 | Supplying and erectingHMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.(1-1-9) |
| 201 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (1-1-10) |
| 202 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. (1-1-11) |
| 203 | Supplying and laying HMS PVC conduitFRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (1-1-12) |
| 204 | Supplying and erecting mains with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW1-3-1 |
| 205 | Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW1-3-1 |
| 206 | Supplying and erecting green colour earthing with 1x 2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (1-3-2) |
| 207 | Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (1-3-2) |
| 208 | Supplying and erecting green colour earthing with 1x 4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (1-3-3) |
| 209 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW. (1-3-3) |
| 210 | Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. (1-6-1) |
| 211 | Supplying and erectingmodular type switch 16Aduly erected on provided plate and box with wiring connections complete. (1-6-2) |
| 212 | Supplying and erectingmodular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete. (1-6-3) |
| 213 | Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. (1-6-10) |
| 214 | Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. (1-6-11) |
| 215 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. (1-6-24) |
| 216 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. (1-6-34) |
| 217 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. (1-6-36) |
| 218 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. (1-6-38) |
| 219 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-40 |
| 220 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and requiredaccessories as per specification No: WG-PW/CW.for 6M Length (1-7-5) |
| 221 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and requiredaccessories as per specification No: WG-PW/CW.for 10M Length (1-7-5+Add on) |
| 222 | Secondary point wiring for additionallight/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW 1-7-22 |
| 223 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and requiredaccessories as per specification No: WG-PW/CW. (1-7-6 New) |
| 224 | Point wiring for light/bellhybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls)in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW 1-7-15 |
| 225 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and requiredaccessories as per specification No: WG-PW/CW 1-7-5 + Note 3 (staircase) |
| 226 | Point wiring for independent plug, concealed type inmin 20 mm FRLS grade HMS PVC conduit with1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch,earthing and requiredaccessories as per specification No WG-PW/SW. (1-7-8) |
| 227 | Wiring for plug on board withSwitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW. (1-7-26) |
| 228 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12Wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. 2-1-16 |
| 229 | Supplying and erectingLED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 2-1-5 |
| 230 | Supplying and erectingLEDPanel Light(600mm X 600mm) Max. 30 Whaving CRCA powder coated housing,polystyrene diffuser havingsystem lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 2-1-7 |
| 231 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22Wwith high transitivity diffuser withsystem lumens output ofMin.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. 2-1-18 |
| 232 | Supplying and erectingLED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 2-1-2 |
| 233 | Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimumlumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg.,THD<10%, p.f. >0.95, operating range of230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty. 2-1-10 |
| 234 | Supplying and erectingbulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. 2-1-15 |
| 235 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty 2-1-8 |
| 236 | Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 237 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size (2-3-13) |
| 238 | Supplyinganderectingluminous / modular type call bell indicator with plasticbody, heavy duty coil and indicatorlamp working on 230V A.C. supplywith resetting arrangement complete erectedondouble wooden/ sunmica board. (2-3-14) |
| 239 | Supplyinganderecting Electronic type cordlesscallbell erected on T.W.board havingportablebellpush working on 9V D.C. battery and(effective range upto 45 meter) bell on 250 V A.C. supply. (2-3-15) |
| 240 | Supplying & erecting 0.5W, 230V integral type LED Lamp suitable for B-22/E-27 base. (2-8-7) |
| 241 | Supplying and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘E’ class insulation. (2-10-4) |
| 242 | Supplying and erectingLED wall light Max. 3W wall Light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. (Non-CSR) |
| 243 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. (2-10-14) |
| 244 | Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF (2-10-16) |
| 245 | Supplying and erectingenergy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF (2-10-21) |
| 246 | Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. (2-11-4) |
| 247 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. (2-11-6) |
| 248 | Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. (1-6-23) |
| 249 | Supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermalfunctioncut-out, valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH (3-1-2) |
| 250 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC (3-3-10) |
| 251 | Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) (3-5-1) |
| 252 | Supplying, erecting, testingandcommissioning of 3kVA capacity onlinepure sine wave with backup time of 30min. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protectionsas per specification no. AP-UPS 3-7-3 |
| 253 | Supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board.5-3-18 |
| 254 | Supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 63Ain provided distribution board.5-3-19 |
| 255 | Supplying, erectingand marking double pole isolator only switch version of miniature circuit breakerof40Awith required wiring connections and lugs etc. in provided distribution board. 5-3-14 |
| 256 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete 3-8-10 |
| 257 | Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (5-3-2) |
| 258 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (5-3-3) |
| 259 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB (5-3-13) |
| 260 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB5-3-6 |
| 261 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 5-3-10 |
| 262 | Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetictype with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 5-6-5 |
| 263 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO5-6-13 |
| 264 | Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs,with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB 5-4-9 |
| 265 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), withdoor, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 (5-4-16) |
| 266 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 5-4-17 |
| 267 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core95sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL (7-1-19) |
| 268 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core25 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL (7-1-15) |
| 269 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL (7-1-16) |
| 270 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL (7-1-17) |
| 271 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core70sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL (7-1-18) |
| 272 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core185 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL (7-1-22) |
| 273 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core240sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL (7-1-23) |
| 274 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core4sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU 7-2-15 |
| 275 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core4sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU 7-2-31 |
| 276 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6 sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU 7-2-32 |
| 277 | Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU 7-2-33 |
| 278 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 100 mm height comprising all required standard accessories. (7-11-5) |
| 279 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories. (7-11-3) |
| 280 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories. (7-11-2) |
| 281 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories. (7-11-1) |
| 282 | Supplying and erecting ironsheet metal work consisting of CRCA sheetsvarious sections of ironplateschequered plates rodsbarsMS pipesetc. for panel board or any other purpose with bendingcuttingdrilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.( For Cross Angles 4.5 Mtrs of 25 X 25angles 4 Nos. 18 Mtrs @1.4 Kg.per mtr 25 2 Kg say 25 Kg.) (6-1-19) |
| 283 | Supplying & erectingconventionalspike typeair termination suitable to carry lightning stroke made up of heavy gauge40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete. (9-3-1) |
| 284 | Typical Floor Panel-Supply Installation Testing and commissioning of LT Panel requirements The Panel Should Be Mfg. From CPRI Approved Panel Manufacturer with IEC-61439 .Panel With 16 SWG 7 Tank Processed Epoxy Powder Coated.Cable Entry From TOP & Out From TOP Side Of Panel. The minimum sizes of sections of bus bars are given in Table VI -CPWD Standard. Each phase duly covered with Red yellow Blue and Black Colour Heat Shrink Sleeves.The Panel Should be Should be Indoor Type & Floor Mountable with IP-42. Name Tag Plates Should Be Provided As Per The Requirement.Paint - Seminice Gray - Powder Coating. The Schematic Drawing for the Above Panel should be get approved from appointed electrical consultant before manufacturing the Panel. The Panel should be Inspected & Tested at Manufacturing Place before dispatch At Site from Electrical Consultant. Incomer should be with R Y B Phase Indicating Lamp & MFM Meter compatible for BMS Monitoring. Refer Electrical Main Single Line diagrams forpanel details. INCOMER: 400 Amp FP MCCB- 1 Nos with R-Y-B & On/off/trip lamps.BUSBAR: 500A, 25kA FP Aluminium Busbar OUTGOING: with on/off/trip indication lamps.125 Amp FP MCCB. -3 Nos63 Amp FP MCCB. -3 Nos 40 Amp FP MCB. - 6 Nos |
| 285 | Typical Floor MPDB-Supply Installation Testing and commissioning of LT Panel requirements The Panel Should Be Mfg. From CPRI Approved Panel Manufacturer with IEC-61439 .Panel With 16 SWG 7 Tank Processed Epoxy Powder Coated.Cable Entry From TOP & Out From TOP Side Of Panel. The minimum sizes of sections of bus bars are given in Table VI -CPWD Standard. Each phase duly covered with Red yellow Blue and Black Colour Heat Shrink Sleeves.The Panel Should be Should be Indoor Type & Floor Mountable with IP-42. Name Tag Plates Should Be Provided As Per The Requirement.Paint - Seminice Gray - Powder Coating. The Schematic Drawing for the Above Panel should be get approved from appointed electrical consultant before manufacturing the Panel. The Panel should be Inspected & Tested at Manufacturing Place before dispatch At Site from Electrical Consultant. Incomer should be with R Y B Phase Indicating Lamp & MFM Meter compatible for BMS Monitoring. Refer Electrical Main Single Line diagrams forpanel details. INCOMER: 250 Amp FP MCCB- 1 Nos with R-Y-B & On/off/trip lamps.BUSBAR: 500A, 25kA FP Aluminium Busbar OUTGOING: with on/off/trip indication lamps.160 Amp FP MCCB. -2 Nos63 Amp FP MCCB. -1 Nos 40 Amp FP MCB. - 8 Nos 40 Amp DP MCB. - 3 Nos |
| 286 | AC Floor Main Panel-Supply Installation Testing and commissioning of LT Panel requirements The Panel Should Be Mfg. From CPRI Approved Panel Manufacturer with IEC-61439 .Panel With 16 SWG 7 Tank Processed Epoxy Powder Coated.Cable Entry From TOP & Out From TOP Side Of Panel. The minimum sizes of sections of bus bars are given in Table VI -CPWD Standard. Each phase duly covered with Red yellow Blue and Black Colour Heat Shrink Sleeves.The Panel Should be Should be Indoor Type & Floor Mountable with IP-42. Name Tag Plates Should Be Provided As Per The Requirement.Paint - Seminice Gray - Powder Coating. The Schematic Drawing for the Above Panel should be get approved from appointed electrical consultant before manufacturing the Panel. The Panel should be Inspected & Tested at Manufacturing Place before dispatch At Site from Electrical Consultant. Incomer should be with R Y B Phase Indicating Lamp & MFM Meter compatible for BMS Monitoring. Refer Electrical Main Single Line diagrams forpanel details. INCOMER: 100 Amp FP MCCB- 1 Nos with R-Y-B & On/off/trip lamps.BUSBAR: 500A, 25kA FP Aluminium Busbar OUTGOING: with on/off/trip indication lamps.63 Amp FP MCCB. -3 Nos40 Amp FP MCB. - 2 Nos |
| 287 | Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breakingcapacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixedmagnetic setting with provided leads, provision for installation of shunt/UV/tripalarm contact. MCCB with phase barriers on both sides, insulation withstandcapacity 800V, no line-load bias in provided enclosure/panel as per specificationno. SW-SWR/MCCB 5-5-1 |
| 288 | Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breakingcapacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting andadjustable magnetic setting with provided leads, provision for installation ofshunt/UV/trip alarm contact and MCCB should have phase barriers both sides,with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCB 5-5-2 |
| 289 | Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breakingcapacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting andadjustable magnetic setting with provided leads, provision for installation ofshunt/UV/trip alarm contact and MCCB should have phase barriers both sides,with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCB 5-5-3 |
| 290 | Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box. 1-5-7 |
| 291 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 292 | SUB- WORK - NO-2 Providing External Electrification Work for Bhimashankar ST Bus Stand,Nigdale Dist-PuneSupplying,erecting,testing and commissioning 11KV LT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paintof required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 10/5A to 50/5A, VA10 or 15, Class 0.5S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.5 suitable for provided trivector meter, andprovision for incoming and outgoing cables complete duly tested by licensee with necessary test certificatesand erected on provided plinth/ cc foundation.-6-4-1 |
| 293 | Supplying, installing, testing and commissioning 11 kV 800A,Outdoor type ring main unit with 1 VCB & 2 LBS with internal arc compliance complete erected on provided CC foundation/MS channels/trench, etc., as per specification no SW-HTS / RMU 5-9-7 |
| 294 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT7-3-7 |
| 295 | Supplying and erecting 200 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating ,APFC panel shall be compliance to IEC 61439 and power qualityIEC 61921 standard as per specification no CP-ED/APFC(6-7-9) |
| 296 | Supplying & erectingG.I. pipe ‘A’ class75 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE .(7-6-4) |
| 297 | Supplyingandlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.(7-6-9) |
| 298 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. (7-6-12) |
| 299 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mmoutside dia, double wall corrugatedpipes (DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. (7-6-14) |
| 300 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mmoutside dia, double wall corrugatedpipes (DWC)ofHDPE for enclosing cable below ground/road surface, to required depth complete. ( 7-6-16) |
| 301 | Supplying & erecting 100 x 50 x 6 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4 m wide DP structure and erecting on DP with 50x6mm clamp complete as per specification no. OH-PL/BKT (8-3-11) |
| 302 | Supplying and erecting ironsheet metal work consisting of CRCA sheetsvarious sections of ironplateschequered plates rodsbarsMS pipesetc. for panel board or any other purpose with bendingcuttingdrilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.( For Cross Angles 4.5 Mtrs of 25 X 25angles 4 Nos.18 Mtrs @1.4 Kg.per mtr 25 2 Kg say 25Kg.) (6-1-19) |
| 303 | Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI (8-5-6) |
| 304 | Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete asper specification no. OH-INS/PN (8-5-9) |
| 305 | Supplying and erecting distribution class, 11 kV thyrite type lightening arrester with nut bolts, on provided MS channel as per specification no. OH-INS/LA(8-5-15) |
| 306 | Supplying and erecting 11 kV outdoor type gangoperated air break,triple pole switch200 A capacitywith3postpin type insulator per phase, mounted in horizontalor vertical position with necessary channelson providedcrossarmwithadequate length of \"C\" class G.l. pipe for operating handle erectedonextendedsquareshaft. Theoperatinghandle provided with lock and key at suitable heightfrom ground level with necessary clamp. ( 10-6-1) |
| 307 | Supplying and erecting, 11 kV outdoor type drop out fuse with insulator complete with fuse holders, fusebarrelwithmetalfitting,fuse elementmounted onM.S.channel with working currentof15A capacity complete erected on provided cross arm. (10-6-5) |
| 308 | Supplyinganderecting hard drawn coppersolidwire no. 0to 6SWG complete erected for connections on H.T. sides. (10-6-10) |
| 309 | Supplyinganderectingextrathick alkathene pipe 10 mm dia. erected to enclosebareconductor wires complete.. (use shall be restricted to H.T.) (10-6-11) |
| 310 | Supplyingheavydutyoperating rod, outerdia 25 mm & inner dia 20 mm suitable for 11 kV with brass couplings etc.for removingdropout fuses at 6 meterslength, 4 pieceseach with rain shade with hand grip including earthling chain 1.5m complete. (10-6-13) |
| 311 | Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG. (10-6-18) |
| 312 | Supplying and erecting 50 x 50 x 6 mm angle iron as cornersupport 2m long fixed at the middle ofthefencing frame and the otherside inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete. (10-6-19) |
| 313 | Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD.(10-6-20) |
| 314 | Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.). (10-6-21) |
| 315 | Providing printed instruction chart for treating persons suffering from electric shock, printedinEnglish & Marathi and duly laminated complete.(10-6-22) |
| 316 | Providingpair ofdulytestedrubber hand glovesas per IS :47705suitable forworking up to 22 kV supply complete.(10-6-23) |
| 317 | Supplying standardfirst aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)(10-6-24) |
| 318 | Supplying and fixingPVC synthetic elastomerelectrically insulating matwith class A insulation conforming to IS: 15652 – 2006having 2 mm thickness up to 3.3 Kv. (10-6-25) |
| 319 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.(13-15-1) |
| 320 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 630 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound Non-sealed transformer delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions , with standard accessories complete with test certificate with losses below 1860 Watts at 50% load, 5300 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL.10-1-10 |
| 321 | Supplying, erecting, testing and commissioning of DIESEL GENERATING SET with alternator confirming to CPCB-IV plus Emission Compliantoutput continuous rating, 3 phase, 415 V, 50 Hz, 0.8 p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G3 and maximum fuel consumptionltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads, with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m provided with first filling of oil, suitable capacity DEF tankdiesel not less than 690 ltr etc., on provided M20 grade CC foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG This D.G set is Fitted in Soundproof & Weather Proof Acoustic Enclosure as per CPCB IV plus Emission Compliant (with acoustic enclosure as per latest Government norms) approved Norms. for bellow mentioned capacity.----\"---- Diesel Generating Set: DG Set Capacity :200KVA, 3 Phase, Maximum Fuel Consumption (Ltr/Hr @75% Loading):54.89,Diesel Tank Capacity ( Ltrs): 850 |
| 322 | Supplying, erecting, testing and commissioning of DIESEL GENERATING SET with alternator confirming to CPCB-IV plus Emission Compliantoutput continuous rating, 3 phase, 415 V, 50 Hz, 0.8 p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G3 and maximum fuel consumptionltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads, with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m provided with first filling of oil, suitable capacity DEF tankdiesel not less than 690 ltr etc., on provided M20 grade CC foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG This D.G set is Fitted in Soundproof & Weather Proof Acoustic Enclosure as per CPCB IV plus Emission Compliant (with acoustic enclosure as per latest Government norms) approved Norms. for bellow mentioned capacity.----\"---- Diesel Generating Set: DG Set Capacity :180KVA, 3 Phase, Maximum Fuel Consumption (Ltr/Hr @75% Loading):54.89,Diesel Tank Capacity ( Ltrs): 850 |
| 323 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 140 kVA up to 180 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. |
| 324 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. |
| 325 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). 16-3-7 |
| 326 | Makingtransformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete.(16-3-1) |
| 327 | Making cement concrete foundationin 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). (16-3-5) |
| 328 | Making cement concrete foundation including excavation(60x 60x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metalwith necessary curing and finishing complete.(for stay).(16-3-6) |
| 329 | Making trench in Hard murum/Tar roadhaving 0.75 m depth and minimum0.3mtr width as per IS for laying provided cables up tovoltage level1.1Kv cable complete as per specification No. CW-EXN-CTR 16-1-2 |
| 330 | Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram). 16-2-4 |
| 331 | Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. 7-6-8 |
| 332 | MAIN LT PANEL - 01Supply Installation Testing and commissioning of LT Panel requirements The Panel Should Be Mfg. From CPRI Approved Panel Manufacturer with IEC-61439 .Panel With 16 SWG 7 Tank Processed Epoxy Powder Coated.Cable Entry From TOP & Out From TOP Side Of Panel. The minimum sizes of sections of bus bars are given in Table VI -CPWD Standard. Each phase duly covered with Red yellow Blue and Black Colour Heat Shrink Sleeves.The Panel Should be Should be Indoor Type & Floor Mountable with IP-42. Name Tag Plates Should Be Provided As Per The Requirement.Paint - Seminice Gray - Powder Coating. The Schematic Drawing for the Above Panel should be get approved from appointed electrical consultant before manufacturing the Panel. The Panel should be Inspected & Tested at Manufacturing Place before dispatch At Site from Electrical Consultant. all feeders with R Y B Phase Indicating Lamp & MFM Meter compatible for BMS Monitoring .All Incoming feeders Should be with OV UV& Earth leakage protection.All ACB\"s shall be EDO. Refer Electrical Main Single Line diagrams forpanel details. INCOMER: 1000 AMP FP ACB - 1 NOS & 630AMP FP ACB- 1 NO 36 KA(Ics=Icu=100% upto 415 V) with R-Y-B & On/off/triplamps, ammeter, voltmeter & multifunction meter.BUSBAR: 1250A, 36kA FP Aluminium Busbar OUTGOING: with on/off/trip indication lamps.400AFP MCCB-1Nos ,400 Amp FP MCCB. - 1 Nos320 Amp FP MCCB. - 2 Nos,250A FP MCCB- 9 Nos,200A FP MCCB- 3 Nos, 125A FP MCCB-2 Nos , 32A FPMCB- 6 Nos |
| 333 | PROJECT COMMON PANEL-Supply Installation Testing and commissioning of LT Panel requirements The Panel Should Be Mfg. From CPRI Approved Panel Manufacturer with IEC-61439 .Panel With 16 SWG 7 Tank Processed Epoxy Powder Coated.Cable Entry From TOP & Out From TOP Side Of Panel. The minimum sizes of sections of bus bars are given in Table VI -CPWD Standard. Each phase duly covered with Red yellow Blue and Black Colour Heat Shrink Sleeves.The Panel Should be Should be Indoor Type & Floor Mountable with IP-42. Name Tag Plates Should Be Provided As Per The Requirement.Paint - Seminice Gray - Powder Coating. The Schematic Drawing for the Above Panel should be get approved from appointed electrical consultant before manufacturing the Panel. The Panel should be Inspected & Tested at Manufacturing Place before dispatch At Site from Electrical Consultant. Incomer should be with R Y B Phase Indicating Lamp & MFM Meter compatible for BMS Monitoring. Refer Electrical Main Single Line diagrams for panel details. INCOMER: 250 Amp FP MCCB- 2 Nos with R-Y-B & On/off/trip lamps. ATS-250A FPBUSBAR: 400A, 25kA FP Aluminium Busbar SUB INCOMER-160A FP MCCB-1 NOS , 250A FP MCCB -1 NOSBUS BAR-200AFP AL& 320 A FP ALOUTGOING: with on/off/trip indication lamps.250 Amp FP MCCB. -1 Nos40 Amp FP MCB. - 8 Nos 40AmpDP MCB -2 Nos |
| 334 | PLUMBING PANEL -Supply Installation Testing and commissioning of LT Panel requirements The Panel Should Be Mfg. From CPRI Approved Panel Manufacturer with IEC-61439 .Panel With 16 SWG 7 Tank Processed Epoxy Powder Coated.Cable Entry From TOP & Out From TOP Side Of Panel. The minimum sizes of sections of bus bars are given in Table VI -CPWD Standard. Each phase duly covered with Red yellow Blue and Black Colour Heat Shrink Sleeves.The Panel Should be Should be Indoor Type & Floor Mountable with IP-42. Name Tag Plates Should Be Provided As Per The Requirement.Paint - Seminice Gray - Powder Coating. The Schematic Drawing for the Above Panel should be get approved from appointed electrical consultant before manufacturing the Panel. The Panel should be Inspected & Tested at Manufacturing Place before dispatch At Site from Electrical Consultant. Incomer should be with R Y B Phase Indicating Lamp & MFM Meter compatible for BMS Monitoring With starter etc. Refer Electrical Main Single Line diagrams forpanel detailsINCOMER: 125 Amp FP MCCB- 1 Nos with R-Y-B & On/off/trip lamps.BUSBAR: 160A, 36kA FP Aluminium Busbar OUTGOING: with on/off/trip indication lamps.40 Amp TP MCB. - 5 Nos |
| 335 | LIGHTING PANEL-Supply Installation Testing and commissioning of LT Panel requirements The Panel Should Be Mfg. From CPRI Approved Panel Manufacturer with IEC-61439 .Panel With 16 SWG 7 Tank Processed Epoxy Powder Coated.Cable Entry From TOP & Out From TOP Side Of Panel. The minimum sizes of sections of bus bars are given in Table VI -CPWD Standard. Each phase duly covered with Red yellow Blue and Black Colour Heat Shrink Sleeves.The Panel Should be Should be Indoor Type & Floor Mountable with IP-42. Name Tag Plates Should Be Provided As Per The Requirement.Paint - Seminice Gray - Powder Coating. The Schematic Drawing for the Above Panel should be get approved from appointed electrical consultant before manufacturing the Panel. The Panel should be Inspected & Tested at Manufacturing Place before dispatch At Site from Electrical Consultant. Incomer should be with R Y B Phase Indicating Lamp & MFM Meter compatible for BMS Monitoring With starter etc. Refer Electrical Main Single Line diagrams forpanel detailsINCOMER: 63 Amp FP MCB- 1 Nos with R-Y-B & On/off/trip lamps.BUSBAR: 100A, 16kA FP Aluminium Busbar OUTGOING: with on/off/trip indication lamps.10 Amp DP MCB. - 12 Nos |
| 336 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core300 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL (7-1-24) |
| 337 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL7-1-23 |
| 338 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL 7-1-22 |
| 339 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL 7-1-21 |
| 340 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm.aluminium conductor complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL7-1-20 |
| 341 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL7-1-19 |
| 342 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP (9-1-1) |
| 343 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameterLow Carbon Steel with 250 micronmolecular copper bonded earthing rod ofLength 3malong with 25 kg Carbonbased environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI (9-1-5) |
| 344 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clampsfixed on wall painted with insulating and non-corrosive bond with requiredjoints As per specification no. EA-EP. (9-2-7) |
| 345 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with insulating and non-corrosive bond with requiredjointsAs per specification no. EA-EP.(9-2-8) |
| 346 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.(3-11-77) |
| 347 | Supplying, erectingand marking triplepoleisolatorsonlyswitch versionofminiaturecircuitbreaker of 40A with required wiring connections and lugs etc. in provided distribution board.5-3-15 |
| 348 | SUB- WORK - NO-3 Providing Solar roof Top Electrification Work for Proposed Bhimashankar ST Stand,Nigdale Dist-PuneSupplying, installing, testing and commissioning of ON-GRID Solar PV System / Plant consisting Solar PV Mono Crystalline Panel 550Wp and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter proper base plate canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB MCB etc. wiring up to solar Inverter in casing and capping display board sign board two distinct earthing lightning arrester liaisoning charges remote monitoring system with maintaining card/chip for 5 years including net charges for RMS System complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG,ON-GRID Solar PV System / Plant consisting Solar PV Mono Crystalline Panel100 KWP (550 wp x 182 Nos) |
| 349 | SupplyinganderectingAC three phase LT CT multifunctionnet meterDLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz,with backlitLCD display, optical port& RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power)with wiring connections and mountinghardwareonprovidedpanelscompletewith calibration certificate from manufacturer. 6.3.15 |
| 350 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 6.1.19 |
| 351 | Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu),adjustablethermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB 5-5-4 |
| 352 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall/ trusses/pole or laid in providedtrench/ pipe as per specification no. CB-LT/AL 7.1.29 |
| 353 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 7-1-20 |
| 354 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 7.6.9 |
| 355 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing orany other purpose).(for Solar Mounting stand). 16-3-7, |
| 356 | SUB- WORK - NO-4 Providing Street Light Electrification Work for Proposed Bhimashankar ST Bus Stand,Nigdale Dist-PuneSupplying & erecting single phase, 240V, street light control panelup to the max load of 12kW, SPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 357 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV |
| 358 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core2.5sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 359 | Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. |
| 360 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. withnecessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 361 | Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2.(2-4-5) |
| 362 | Light Bulb Included Holder Type E27Weight 7190 GMProduct Category Outdoor LightingDimensions 21 X 53 X 210 CMMaterial Metal, GlassColor BrownProduct Includes 1 Pole LightNumber of Lights 2 X45w |
| 363 | Supplying & erectingwater tight terminal box of 1.6 mm (16 gauge) CRCA sheet of size 300 x 200 x 150 mmcomplete on poleas per specification No. CB-SB |
| 364 | Supplying and erectingConcealed type foot/step light Max. 5Whaving IP67. IK10 rated Pressure die casthousing having system lumens output of Min. 500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg.,THD<10%, SDCM<5,p.f. >0.95, operating range of230-270V, surge protection of 2.5 kV, Life class of 25,000 Hrs. at L70B50, including driver by making necessary arrangement/recess in wall to make it flush with surface with 2 Year warranty. |
| 365 | Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser,havingsystem lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification NoFG-ODF/FLS2.Pole-1.2mtr |
| 366 | SITC of 30W 2400 Lumens Surface Mounted Downlight made up of Extruded Aluminum Housing duly pure polyester powder coated Dark gray color with Tougehened glass on front .Having height of 230mm & dia of 100mm. Suitable for OutdoorInstallation with IP65 & IK06 Rating. LED Must be of make Nichia/ Cree/Bridgelux having 50000 Burning Hours at L70B50, CRI 70, 3000K CCT, Luminaires having beam angles of 23deg.Driver is Integral to Luminaires & suitable to operate in Voltage range of 140-280V, Driver Efficiency greater than 85%, THD less than 10% & PF greater than 0.95, Internal Surge Protections 3KV.Provision of pig tell cable for ease of wiring. OEM must Submit LM80,LM79, BIS & Photobiological Safety reports for approval. Waranty must be 5years. |
| 367 | SITC of 30W 2400 Lumens Reccessed Mounted Downlight made up of Extruded Aluminum Housing duly pure polyester powder coated Dark gray color with Tougehened glass on front.Having height of 175mm & dia of 100mm. Suitable for OutdoorInstallation with IP65 & IK06 Rating. LED Must be of make Nichia/ Cree/Bridgelux having 50000 Burning Hours at L70B50, CRI 70, 3000K CCT, Luminaires having beam angles of 23deg.Driver is IP66 Rated External to Luminaires & suitable to operate in Voltage range of 140-280V, Driver Efficiency greater than 85%, THD less than 10% & PF greater than 0.95, Internal Surge Protections 3KV. OEM must Submit LM80,LM79, BIS & Photobiological Safety reports for approval. Waranty must be 5years. |
| 368 | SITC of 40W 3600 Lumens 1000mm Linear Wall Washer made up of Extruded aluminum housing & PDC End cap duly pure polyester powder coated in dark grey (RAL7021) with Tougehened glass on front.Having height of 75mm & width of 46.5mm. Suitable for OutdoorInstallation with IP66 & IK07 Rating. LED Must be of make Nichia/Seoul/ Cree/Bridgeluxhaving 50000 Burning Hours at L70B50, CRI 70, 3000K CCT, Luminaires having beam angles of 15 by 40 deg Assymteric.IP67 Driver Fixed on Luminaires& suitable to operate in Voltage range of 100-300V, Driver Efficiency greater than 80%,PF greater than 0.95, Internal Surge Protections 3KV. OEM must Submit LM80,LM79, BIS & Photobiological Safety reports for approval. Waranty must be 5years. |
| 369 | SITC of 60W 3300 Lumens Flood Light made up of Aluminum die cast housing duly Powder coated with gray pure polyester powder with Integrated High Purity Lens front.Having height of 149mm & dia of 148 mm. Suitable for OutdoorInstallation with IP66 & IK08 Rating. LED Must be of make Nichia/Seoul/Osram/ Cree/Bridgeluxhaving 50000 Burning Hours at L70B50, CRI 80, 3000K CCT, Luminaires having beam angles of 15 deg .IP67 Driver Fixed external with Loop in loop out features. Driver suitable to operate in Voltage range of 100-300V, Driver Efficiency greater than 80%,PF greater than 0.95, Internal Surge Protections 3KV. OEM must Submit LM80,LM79, BIS & Photobiological Safety reports for approval. Waranty must be 5years. |
| 370 | SITC of 10W 850 Lumens Spike Lights for Tree Highlighter made up of Extruded aluminum housing duly pure polyester powder coated Dark gray color with Toughened Glass.Having height of 185mm & dia of 65 mm. Suitable for OutdoorInstallation with IP65 & IK06 Rating. LED Must be of make Nichia/Seoul/ Cree/Bridgeluxhaving 50000 Burning Hours at L70B50, CRI 70, 3000K CCT, Luminaires having beam angles of 15 deg . Driver is Internal & suitable to operate in Voltage range of 140-280V, Driver Efficiency greater than 80%,PF greater than 0.95, Internal Surge Protections 3KV. OEM must Submit LM80,LM79, BIS & Photobiological Safety reports for approval. Waranty must be 5years. |
| 371 | Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. |
| 372 | SITC of 18W 900 Lumens Inground/ Ground Burrial Lights made up of Al Die cast heatsink ,Engineering Plastic cover in black with SS ring with Toughened Glass suitable for walkover.Having height of 90mm & dia of 200 mm. Suitable for OutdoorInstallation with IP67 & IK10 Rating. LED Must be of make.having 50000 Burning Hours at L70B50, CRI 80, 3000K CCT, Luminaires having beam angles of 30 deg . Driver to be Installed Externally & suitable to operate in Voltage range of 100-300V, Driver Efficiency greater than 80%,PF greater than 0.95, Internal Surge Protections 3KV. OEM must Submit LM80,LM79, BIS & Photobiological Safety reports for approval. Waranty must be 5years. |
| 373 | Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 , including driver complete with 2 Year warranty as per specification No FGODF/FLS2. Pole-2.5mtr |
| 374 | SITC of 14W /mtrs- 5 mtr roll714 Lumens/Mtrs Strip Lights made up of Silicone Ectrusion. Suitable for OutdoorInstallation with IP67Rating. LED Must be of make.having 50000 Burning Hours at L70B50, CRI 80, 3000K CCT, Luminaires having diffused dotless ambience & suitable for Top Bend . Driver to be Installed Externally & suitable to operate in Voltage range of 100-300V, Driver Efficiency greater than 80%,PF greater than 0.95, Internal Surge Protections 3KV. OEM must Submit LM80,LM79, BIS & Photobiological Safety reports for approval. Waranty must be 5years. |
| 375 | SITC of 2*18W 2*1620 Lumens Up Down Wall Mounted Lights made up of Extruded aluminum housingduly pure polyester powder coated Dark gray color with Toughened Glass Front. Suitable for OutdoorInstallation with IP65Rating. LED Must be of make.having 50000 Burning Hours at L70B50, CRI 70, 3000K CCT, Luminaires having beam angle of 29deg . Driver is Internal & suitable to operate in Voltage range of 140-280V, Driver Efficiency greater than 85%,PF greater than 0.95, THD Less than 10%, Internal Surge Protections 3KV. OEM must Submit LM80,LM79, BIS & Photobiological Safety reports for approval. Waranty must be 5years. |
| 376 | Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT -8-2-22 |
| 377 | Supplying and erecting of decorative single bracket Street light pole 7 mtr Also, the lighting pole shall be cast iron, All forms of Pole true to the pattern/mould with decorative embellishments.as cast iron parts. The poles are painted with Polyurethane paint for a longer service life. CastThe pole is provided with 3 Each, of hot dip galvanized type Anchor bolts. A door is provided with anchorage and wiring accessories. The colour of lamp is Antique copper. Material used in poles iron, an alloy of iron that contains 2 to 4 percent carbon, along with varying amounts of silicon and manganese and traces of impurities such as sulphur and phosphorus. Bottom of pole is rectangle shape and top or other is circular shape of pole. The product is an all-weather proof & Maintenance free. It\"s self coloured textured surface finish with scratch resistant aliphatic grade UV. Stabilized PU. Paint with UV stale Polyurethane. The thermal conductivities properties of cast irons range widely from 20 to 70 w/m/c. Include 2 mtr bottom side decorative pole, 4 mtr plane pole & 1 mtr Invert U decorative gradually decreasing diameter. Surface finish colour coated. Shap is rounded. With 2 years warranty |
| 378 | Supplying and erecting Clear post top and Top Mounting LED Lantern to be installaed in suspended manner on ornamental pole bracketv, 70 W fitting Top mount lantern, Aluminium Di cast Housing. Acrylic Diffuser, with a historical appearance that offers high performance.Luminous flux-5050 Im, Luminaire efficacy - 70 Im/W, Input Voltage - 150V to 270V AC, Input Frequency - 50 Hz, Ingress Protection - IP65 With 2 years warrantyTag: TF-Clear post top and Top Mounting LED Lantern 1 x 70 W fitting (NON CSR) |
| 379 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT -8-2-21 |
| 380 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). |
| 381 | SUB- WORK - NO-5 Providing EV Electrification Work for Proposed Bhimashankar ST Stand,Nigdale Dist-PuneSupplying, erecting, testing and commissioning of 15 KW DC ElectricVehicle Charger (suitable for 4 wheeler)having minimum IK08 & IP54protection suitable for three phase 415V AC 50Hz incoming supply and 1 no.output charger interface GB/T with 40-100VDC supply and 15 kW capacity,interlocking arrangement with minimum 5 meter charging cable length , 7\" LCDtouch screen for human interface & LED light for status indication, metering formeasurement of consumed energy having metering accuracy +/-1%, One hourbattery backup for communication, emergency push stop button. User interface bymobile application/QR Code/RIFD Card/Password Login with payment optionsand having short circuit, over & under voltage, surge protection, earth leakageprotection and enclosure made of minimum 1.5mm duly RAL7035 coated M.S,erected on iron/GI frame on provided cement concrete foundation completewith one year on site warranty, confirming to IS 17017 Series as per specification |
| 382 | Supplying, erecting, testing and commissioning of 10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) having minimum IK08/IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming and 3 nos. of outgoing as per IEC 60309 industrial sockets having capacity of output current of 16A 240VAC at each socket with 3.5\"TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button,with user interface by mobile application/QR Code/RFID Card and having short circuit, over & under voltage, overload,over temperature, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 Coated M.S, Erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, Confirming to IS 17017 Series as per specification no. ESD-EVC. |
| 383 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE forenclosing cable below ground/road surface, to required depth complete.(CSR No : 7-6-10) |
| 384 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core120sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 385 | Making cement concrete foundation including excavation(60x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45x 45x 45) cm /45 cm dia. x 45 cm height plinth duly plastered,with necessary curing and finishing complete.30 kW DC Electric Vehicle Charge-20 =0.8*0.6*0.6=5.76 App 6 Meter cube0kW, 3 x 3.3 KW AC Electric Vehicle charger -20 =0.8*0.6*0.6=5.76 App 6 Meter cube =Total 12 mcube |
| 386 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clampsfixed on wall painted with insulating and non-corrosive bond with requiredjoints As per specification no. EA-EP. |
| 387 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with insulating and non-corrosive bond with requiredjointsAs per specification no. EA-EP. |
| 388 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameterLow Carbon Steel with 250 micronmolecular copper bonded earthing rod ofLength 3malong with 25 kg Carbonbased environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 389 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core25 sq. mm. copper conductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 390 | Supplying and erecting triple pole mini feeder pillarwith500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP |
| 391 | SUB- WORK - NO-6 Providing LA-Early Steamer Emmision system Electrification Work for Proposed Bhimashankar ST Stand,Nigdale Dist-PuneSupplying, Erecting, Testing and Commissioning ofESE Lightning Arrester, Controlled Early StreamerEmission Air terminal (ESEAT) with following specifications:ESEAT Protection Radius - 107 Mtr. with suitablemast height, with triggering time of 60 micro secondas per NFC 17-102 which emits local electrostaticfield that develops naturally around the shaft as a thunderstorm begins to gather, The ESEAT air-terminal shall be tested to support a200kA current (waveform 10/350 μs). Test to be performed in compliance with NFC 17 102 version2011 The ESEAT Should be able to work in both (positiveand negative) lightning polarities. The ESEAT shall be in Strict compliance with thenew test guidelines as per \"Annex C\" of the revisedNFC 17 102 version 2011(As Amended up to date)for ESE lightning protection system.The ESEAT shall be made of Stainless Steel304L/316 grade non-corrosive metallic components,Electronic Circuit, Capacitor Bank, Transformer,Amplifier, Sensor etc. to generate the Streamer.The ESEAT to be a fully autonomous systemrequiring no external power supply. The ESEAT shall be Testable on site, using proprietary testers. The ESEAT should be sustainably designed to mitigate its environmental impact. The ESEAT to be mounted on provided base &support arrangements and installed as per the Technical specifications & General ArrangementsDrawing attached complete with testing Warranty: 5 years (60 months) from the date of commissioning Non CSR Aproved by SE electrical vide letter no क्रमांकमु अ (वि )/ का - ३ अर्थ / 2285 2021 dt 30 dec 2021 |
| 392 | Supplying and erecting ISI mark GIpipe 50 mm. dia ‘C” class position with accessories complete. Specification no. CW-PLB/GP this item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached complete with testing . |
| 393 | Supplying and erecting ISI mark GI pipe 65 mm. dia ‘C” classposition with accessories complete. Specification no. CW-PLB/GP.this item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached complete with testing . |
| 394 | upplying and erecting heavy duty Galvanized mildsteel pole coupler suitable for connecting C classGI pipe size 50 mm.dia & C class GI pipe size 50mm.dia 65mm dia duly threaded or welded complete with necessary arrangements & erected inposition complete with ensuring electricalconductivitythis item proposed to installed as per the Technicalspecifications & General Arrangements Drawing attached complete with testing |
| 395 | Supplying and fixing base for ESEAT cum polecap duly galvanized with necessary anticorrosivetreatment fabricated from mild steel fixed to pole topby means of welding and fixed at position withrequired size & type threads suitable for mounting ofESEAT with 2nos earth terminals having min.30x6mm cross section 50mm length each towardsdown direction for fixing 2nos down conductorswith necessary welded GI nuts & bolts of requiredsize with washerthis item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached completeNon CSR Aproved by SE electrical vide letter no क्रमांकमु अ (वि )/ का - ३ अर्थ / 2285 2021 dt 30 dec 2021 |
| 396 | Supplying and fixing Pole base plate made up ofmild steel having minimum 250mm size and 10mmthick fixed to pole base by welding with min. 4nostriangular cross arms of min 6mm thick welded duly galvanizedand fixed at position. With 4nos 20mmdia holes for erection on provided foundationthis item proposed to installed as per the Technicalspecifications & General Arrangements Drawing attached complete Non CSR Aproved by SE electrical vide letter no क्रमांकमु अ (वि )/ का - ३ अर्थ / 2285 2021 dt 30 dec 2021 |
| 397 | MakingM- 20 grade reinforced cement concretefoundation byconsidering the safe soil bearing capacity at site as 10 T/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole). this item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached complete with testing . |
| 398 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws,G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and poleclamps duly erected in provided cement concrete foundation complete.this item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached complete with testing . |
| 399 | Making cement concrete foundation including excavation(60x 60x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metalwith necessary curing and finishing complete.(for stay). |
| 400 | Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for HV/EHV (11000 Volts) installation with compliance to IS 2551-1982 this item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached complete with testing . |
| 401 | Supplying and erecting Contra go up devicefabricated from required size mild steel flat of 40x5mm dult welded with mild steel drooping spikes ofmin. 200mm long completely galvanized erected on pole with necessary GI nut bolts complete.this item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached complete Non CSR Aproved by SE electrical vide letter no क्रमांकमु अ (वि )/ का - ३ अर्थ / 2285 2021 dt 30 dec 2021 |
| 402 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. Weight analysis 25 X 6 mm GI Strip , 1.2 Kg / mtr for total length 18+3+3+4*3=36 mtr total weight 43.2 kg X3 nos = 129.6 (this item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached complete with testing . ) |
| 403 | Supplying and erecting pole clamp made fromrequired size MS flat for pole post galvanized &painted with one coat of red oxide and two coats ofaluminium paint and erected with necessary GIbolts and nuts, complete suitable for erecting TestJoint & Lightning flash counter this item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached complete Non CSR Aproved by SE electrical vide letter no क्रमांकमु अ (वि )/ का - ३ अर्थ / 2285 2021 dt 30 dec 2021 |
| 404 | Supplying and Erecting Test Joint[Test Clamp]mounted in between the Earth Electrode(EC) andDown Conductor(DC)at the height of about 2meterabove ground level to be done as per relevant IS specifications designed and situated so as theresistance of Earth Electrode can be measured Test Clamp to be attached to pole with provided Poleclamp this item proposed to installed as per the Technicalspecifications & General Arrangements Drawing attached complete with testingNon CSR Aproved by SE electrical vide letter no क्रमांकमु अ (वि )/ का - ३ अर्थ / 2285 2021 dt 30 dec 2021 |
| 405 | Supply, Installation, Testing & Commissioning ofminimum 2 Digit Digital Lightning StrikeCounter(LSC) Electronically controlled and mounted on down conductor having followingfeatures:a. Strike detection range: 1 KA to 100 KA.b. Minimum current sensitivity (id/3): 500 Ac. Protection class: IP 67 (Without Enclosure)d. Easy to monitor and install and No maintenancerequired.e. Standards applicable: IEC 62561 Lightningprotection system components (LPSC) - Part 6:Requirements for lightning strike counters (LSC) Lightning strike Counter to be mounted at a height of about 2mtr from Ground level with provided Poleclamp this item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached complete with Testing Non CSR Aproved by SE electrical vide letter no क्रमांकमु अ (वि )/ का - ३ अर्थ / 2285 2021 dt 30 dec 2021 |
| 406 | Supplying, erecting, testing & commissioning ofMaintenance free earthing system suitable forlightning protection system. The earth pit comprisesof 125 to 150mm inner dia bore up to suitable depthfrom ground surface and a high corrosion resistancematerial of minimum 250 micron copper bondedsolid steel rod electrode of 2meter long having 17.2mm dia. with necessary conductor clamps for Earthrod/Earth rod to tape connector clamp etc. as per siterequirements. with backfill earthing compound withGround Enhancing compound combination ofminimum 30Kg as per IS 3043- 2018 and IEEE 80- 2000 with satisfactory Test report from Govt. ownedTest Laboratory .The requirements of Ground enhancing Compundare as Follows:a ) The compound shall have Ionic property to createions for easy conduction.b) The compound shall be enable to disperse the ionsequally in the earth pits.c) The compound should expand so much to removeentrapped air (bad Conductor of electricity) andcreate a strong conduction between electrode andsoil.d) The compound should diffuse in the soil to createconductive silicate. This Silicate should expand intothe soil with the edge of the earth pits and result inprogressive reduction of earth pit resistance.e) The compound should have a property to assist inabsorbing humidity from the neighbouring soil tokeep earth pit moist, which in turn helps betterconduction.f) The compound should have the property to ensuremoisture is retained throughout the year irrespectiveof the weather condition without addition of waterduring the life of the earth pit.g) The compound should be non toxic, non reactive,non explosive & non corrosive.h) The compound shall be permanent & maintenancefree and in its “set form”, maintain constant earthresistance with time.this item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached complete with testing Non CSR Aproved by SE electrical vide letter no क्रमांकमु अ (वि )/ का - ३ अर्थ / 2285 2021 dt 30 dec 2021 |
| 407 | Suppling & erecting HDPE (High DensityPolyethylene) earthing pit inspection chamber with Cover having factory Built Holes for accessingStrip/Wires easily at two sides made of Environmentfriendly Withstand colour /UV unaffected Resistantmaterials, assuring durability and 5Ton load bearingcapacity.Minimum Dimensions are 260mm at Top, 260mm atBottom, 210mm Height this item proposed to installed as per the Technicalspecifications & General Arrangements Drawingattached complete with testing Non CSR Aproved by SE electrical vide letter no क्रमांकमु अ (वि )/ का - ३ अर्थ / 2285 2021 dt 30 dec 2021 |
| 408 | SUB- WORK - NO-7 Providing HVAC Work For Large and Samll Bus stand at Nigade Dist PuneSupplying 230/250V, 50Hz, evaporative air cooler (desert cooler) having normal cooling capacity of 50cu.m per minute, with 12\" exhaust, min 40 to 55 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non-corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non-corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dBA at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthing complete as per specification no. AP-WCR/DAC |
| 409 | Supplying 230/250V, 50Hz, evaporative air cooler (desert cooler) having normal cooling capacity of 60 to 70 cu.m per minute, with 12\" exhaust, min 68 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non-corrosive material, circular opening shall be more than fan sweep but not exceeding more than25mm, filter pads shall be made of wood wool or any other substitute placed in non-corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dBA at 1m distance, 3 core copper cable minimum2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. AP-WCR/DAC |
| 410 | Supplying 230/250V, 50Hz, evaporative air cooler (desert cooler) duct type having normal cooling capacity of 120cu.m per minute, with 17\" exhaust, min 75 to 80 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non-corrosive material, circular opening shall be more than fan sweep but not exceeding morethan 25mm, filter pads shall be made of wood wool or any other substitute placed in non-corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dBA at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. AP-WCR/DAC |
| 411 | Supplying and erecting exhaust fan heavy duty 440 V A.C. 50 cycles 900 RPM 375/380 mm complete erected in position as per specification no. FG-FN/EXF |
| 412 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 413 | Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275microns with galvanization process compliance to IS 2629:1985 to be usedfor fabrication of boxes panel boards etc. including cutting, bending, drilling,welding, riveting etc. and painting with one coat of red lead paint and 2 coats ofenamel paint.0.55 |
| 414 | Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275microns with galvanization process compliance to IS 2629:1985 to be usedfor fabrication of boxes panel boards etc. including cutting, bending, drilling,welding, riveting etc. and painting with one coat of red lead paint and 2 coats ofenamel paint.0.7 |
| 415 | Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275microns with galvanization process compliance to IS 2629:1985 to be usedfor fabrication of boxes panel boards etc. including cutting, bending, drilling,welding, riveting etc. and painting with one coat of red lead paint and 2 coats ofenamel paint.0.9 |
| 416 | Supplying and erecting GI sheet 1.25 mm (18 SWG) having zinc coating of350 microns with galvanization process compliance to IS 2629:1985 to beused for fabrication of boxes panel boards etc. including cutting, bending,drilling, welding, riveting etc. and painting with one coat of red lead paint and 2coats of enamel paint.1.2 |
| 417 | Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 300 cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete. |
| 418 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 419 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 420 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 421 | Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete. 3-11-82 Pg No 76 |
| 422 | Supply, installation, testing and commissioning of volume control box with collor for control damper of required sizes in GI construction complete with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete. 3-11-81 Pg No 76CSR No.3-11-81 |
| 423 | Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45 degree. 3-11-88 Pg No 76CSR No.3-11-88 |
| 424 | HVAC Panel Design,fabrication,assembling,supply,inst allation,testingand commissioning of cubicle type LT panels suitable for415 V3 phase ,4 wire 50 Hz AC supply system fabricatedin compartmentised design from CRCA sheet steel of 2mm thick for frame work IP 52 and covers,3 mm thick forgland plates i/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032,extendable type TPN aluminium alloy bus bars of high conductivity,DMC/SMC busbar supports, with bottom base channel of MS section not less than 75mm X 50 mm X 5mm thick, entire panel shall have a common copper earthbar of required size at the rear with2 nos earthstuds, solid connection from main busbar to switchgearswith require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable ,cablealleys ,cable gland plates i/c accessories as per specification and providing switchgears, metering instruments etc. for follwing panelsINCOMER:200 AMP 4P MCCB- 1 Nos 36 KA(Ics=Icu=100% upto 415 V) with R-Y-B& On/off/triplamps, ammeter, voltmeter & multifunction meter.BUSBAR: 250A, 36kA FP Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar.OUTGOING: (50kA Ics=Icu=100% upto 433V) with on/off/trip indication lamps & multifunction meterO/G32 Amp DP MCB- 35Nos63 Amp FP MCCB- 2Nos |
| 425 | SUB- WORK - NO-8 Providing LVWork For Bhimashankar Small and Large Bus Stand at Nigdale Dist PuneSupplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. |
| 426 | Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP |
| 427 | Supplying, installing, testing and commissioning of addressable optical smokedetector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to32 V DC two wires supply, in-built locking mechanism to check the removal andpilferage of the detector, in built isolation mode, start up current 300μA and alarmcondition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C,humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/SD . |
| 428 | Supplying, installing, testing and commissioning of intelligent addressablethermal/heat detector with rate of rise cum fixed temperature thermistorcomplete with base as required, suitable for temperature variations from -20°C to38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heattype detectors, in built isolation mode, suitable for offices/ceiling cabletrenches/less ventilation area\"s etc. with 3 years equipment replacement warrantyIS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 429 | Supplying, installing, testing and commissioning of intelligent addressablethermal/ heat detector with rate of rise cum fixed temperature thermistorcomplete with base as required, suitable for temperature variations from - 20°C to38 °C for fixed-heat and rate-of-rise type detectors whereas 0°C to 90°C for highheat type detectors, in built isolation mode, suitable for industrial/ kitchen/ boilerroom etc. with 3 years equipment replacement warranty, IS : 2175-1988reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 430 | Supplying, installing, testing and commissioning of addressable manual callpoints ( break glass type/pull station type), made of addressable break glassplastic square in shape surface/flush mounted with \"Break Glass\" massageembedded on the glass, complete erected with mounting base and requiredaccessories conforming to EN 54 or UL listed with 3 years equipmentreplacement warranty FF-AFAS/MCP. |
| 431 | Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 orUL Listed FF-AFAS/CRM |
| 432 | Supplying, installing, testing and commissioning of addressable fire monitormodule complete as required. EN 54 or UL Listed with 3 years equipmentreplacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relaysFF-AFAS/MM |
| 433 | Supplying, installing, testing and commissioning of addressable fire isolatormodule complete as required. EN 54 /FM or UL Listed with 3 years equipmentreplacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relaysFF-AFAS/ISM |
| 434 | Supplying, installing, testing and commissioning of addressable horn cumstrobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chartgiven in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operatingvoltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with3 years equipment replacement warranty FF-AFAS/SSH. |
| 435 | Supplying, installing, testing and commissioning of digital linear heat detectioncable addressable through monitor module with temperature ratings such as 60°-70°C, conforming to IS 2189: 2008, EN 54 or UL listed FF-AFAS/LHDC. |
| 436 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 437 | Supplying, installation , testing and commissioning of Priority Switching Module micro processor based for 16 ZONEwith suitable selection module (having key padfor zone selection with LCD display), power supply unit c/w battery, program timer etc. |
| 438 | Supplying, erecting, testing and commissioning 2000 W amplifier suitable tooperate on 230 Volts A.C. / 12 Volts D.C. supply complete as perspecification no. FF-PA/AFR |
| 439 | Supplying, erecting, testing and commissioning 15 to 30 Watts soundcolumn or ceiling mounted complete as per specification no. FF-PA/SOC |
| 440 | Supplying, erecting, testing and commissioning 15 to 30 Watts soundHorn Type mounted complete as per specification no. FF-PA/SOC |
| 441 | Supplying, erecting, testing and commissioning stand mounted/handheldtype wired microphone having 2 mV/Pa sensitivity, impedance level limit 300ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min.7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jackcomplete as per specification no. FF-PA/MIC |
| 442 | Supplying, erecting, testing and commissioning rust free microphone floorstand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mmheight and sturdy mechanism ensuring trouble free movement complete. |
| 443 | Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC |
| 444 | Rack of Approx. (600mm X 2100mm) high amplifier rack assembly made of aluminium channel equivalent to euro rack system, with side and rear panels made of 14 swg powder coated sheet steel front transparent persplexdoor and with rails, rollers & bearings. Fans shall provided at the top for ventilation side panels will be ventilated type. The rack shall be powder coatedof approved colour and spare \"U\" shall be covered with blank panels. |
| 445 | Supplying, Installing, Testing and Commissioning of Condenser gooseneck mic (cardioid), black, length 500 mm (18\"), two flexible segments, programmable switch (PTT, PTM, ON/OFF), Braille-marking, switchable illuminated ring, switchable low cut filter,3-pin XLR male, windscreen included with base. |
| 446 | Fire Alarm Control Panel (FACP) interfaces with other building systems, such as the Building Management System (BMS), via standard protocols like BACnet or Modbus, or proprietary interfaces, to exchange data and control functions |
| 447 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 448 | Providing, commissioning and maintaining temporary CCTV system with 66 channel NVR, IP video/audio input-1 no, IP based 4.0 MP, Full HD, IR IP dome camera - 2 nos, IP based 4.0 MP, Full HD, IR IP PTZ camera - 4 nos, 8TB Hard Disk - 2 no, 42\"\" Full H D professional display - 1 no, 16 port PoE Switch - 2 no, Power supply unit to camera - 1 no, On Line UPS - 1 no with necessary mains, switchgears on hire basis for one day. |
| 449 | High definition4/5 MegapixelIP IR Dome Camerawith following featuresImage Sensor : minimum 1/2.8\" Progressive Scan CMOS, Video Resolution:minimum 2592 x 1520VideoCompression: H.264,H.265or higher,at leastThree individually configurable stream,Frame Rate : minimum 25 fps at all resolutions WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant.minimum IR distance : 50m,Lens Type: 2.8 - 13mm Lens, auto/motorized varifocal focal, Field of View : horizontal FOV 103° to 32°, vertical FOV 73° to 24°, diagonal FOV 142° to 40°Luxsensitivity- minimum0.2Luxat color,minimum0.05LuxatBlack& White,0.0Lux(IR)NightVisionDistanceMin IR- 30m,Camera minimum AdjustmentAngles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE, IP67/IP66, IK10,built in micro SD/SDHC/SDXC card slot of min 128 GB, built in microphone.minimum Input/Output- Audio in × 1, Audio Out × 1, Alarm in× 1, Alarm Out × 1.Image Settings : Rotate mode, saturation,brightness,contrast, sharpness, gain, white balance.ImageEnhancements: Day/Night-Auto(ICR)/Color/Black&White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. (3 Years Warrenty) |
| 450 | High definition4/5 MegapixelIP IR VarifocalDome Camerawith following featuresImage Sensor : minimum 1/2.8\" Progressive Scan CMOS, Video Resolution:minimum 2592 x 1520VideoCompression: H.264,H.265or higher,at leastThree individually configurable stream,Frame Rate : minimum 25 fps at all resolutions WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant.minimum IR distance : 50m,Lens Type: 2.8 - 13mm Lens, auto/motorized varifocal focal, Field of View : horizontal FOV 103° to 32°, vertical FOV 73° to 24°, diagonal FOV 142° to 40°Luxsensitivity- minimum0.2Luxat color,minimum0.05LuxatBlack& White,0.0Lux(IR)NightVisionDistanceMin IR- 30m,Camera minimum AdjustmentAngles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE, IP67/IP66, IK10,built in micro SD/SDHC/SDXC card slot of min 128 GB, built in microphone.minimum Input/Output- Audio in × 1, Audio Out × 1, Alarm in× 1, Alarm Out × 1.Image Settings : Rotate mode, saturation,brightness,contrast, sharpness, gain, white balance.ImageEnhancements: Day/Night-Auto(ICR)/Color/Black&White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. (3 Years Warrenty) |
| 451 | Supply Installation, testing & commissining of Indoor type IP Mini Dome type Camera with 1/2\" 2 Mega Pixel progressive CMOS Sensor, integrated 2.8mm Fixed Lens, 2MP high definition, Minimum Triple Stream Support, Inbuilt Smart IR LED upto 10m distance, 0.002 lux color/0 lux with IR LEDs on, H.265 profile, True WDR min 120 dB, True Day/Night, Built in Power over Ethernet (PoE), & 12VDC operated, inbuilt Micro SD Card Slot support min 64GB, Inbuilt motion detection, tampering alarm, ONVIF Profile S & G compliant, with Junction box & required accessories. |
| 452 | Supply, installation, testing & commissioning of 1 set of Module (Transmitter & Receiver) for wireless communication for above camera (Wi-Fi / IP Based system) with required accessories. |
| 453 | High definition4/5 MegapixelIP IR VarifocalDome Camerawith following featuresImage Sensor : minimum 1/2.8\" Progressive Scan CMOS, Video Resolution:minimum 2592 x 1520VideoCompression: H.264,H.265or higher,at leastThree individually configurable stream,Frame Rate : minimum 25 fps at all resolutions WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant.minimum IR distance : 50m,Lens Type: 2.8 - 13mm Lens, auto/motorized varifocal focal, Field of View : horizontal FOV 103° to 32°, vertical FOV 73° to 24°, diagonal FOV 142° to 40°Luxsensitivity- minimum0.2Luxat color,minimum0.05LuxatBlack& White,0.0Lux(IR)NightVisionDistanceMin IR- 30m,Camera minimum AdjustmentAngles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE, IP67/IP66, IK10,built in micro SD/SDHC/SDXC card slot of min 128 GB, built in microphone.minimum Input/Output- Audio in × 1, Audio Out × 1, Alarm in× 1, Alarm Out × 1.Image Settings : Rotate mode, saturation,brightness,contrast, sharpness, gain, white balance.ImageEnhancements: Day/Night-Auto(ICR)/Color/Black&White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. (3 Years Warrenty) |
| 454 | Supply, installation, testing & commissioning of CCTV Profestional 24X7 operation, 365days, Wall mount 42\" Full HD Flat LED TV / Monitor having VGA & HDMI port with wall mount accessories. |
| 455 | Design, Fabrication, Supply and installation of Tubular G.I. Pole having 6mtrs height. using 100mm dia. pipe and 250x250mm,10mm thick base plate, for mounting with cable entry provisions from pole bottom and including arrangement for fixing of Bullet camera with brackets and required accessories, etc. The pole shall be painted with 2 coats of primer & bottom with black paint & 2 coat of silver paint etc. complete. (for outdoor camera) |
| 456 | Supply, installation, testing & commissioning of Basic L2 features, 24 Port NON PoE auto-sensing 10/100/1000 Network Switch with 2X1Gb Uplink Ports including standard connectivity accessories. (for common Data network) |
| 457 | Supply, installation, testing & commissioning of 6 Port Fiber LIU with Pigtails & required accessories. |
| 458 | Supply, installation, testing & commissioning of CAT 6, 24 port Loaded Patch Panel with required accessories. |
| 459 | Supply & installation of 12U 600mm x 550mm Wall mount Rack with Front Glass Door, Fan Tray on Top, Perforated Rear Doors, Openable Entry at the Bottom for the Cable entry, Cable Basket for Cable Dressing & Vertical Power Strip with all necessary accessories & hardware. |
| 460 | Supply, installation, testing & commissioning of6 Core Single Mode Fiber Optic Cable, Outdoor Type with required end termination. |
| 461 | Supplying and installing cat-6 cable suitable for networking as per specificationno. WG-COC/NC |
| 462 | Supply, laying & testing of Cat 6 Armoured UTP cable including labelling and end termination with connectors both end. |
| 463 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 464 | Supplying and laying HMS PVC conduit FRLS grade 50 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. 50 mm perforated tray 16 SWG. |
| 465 | Supplying and laying HMS PVC conduit FRLS grade 100 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. 100 mm perforated tray 16 SWG |
| 466 | Supplying and laying HMS PVC conduit FRLS grade 200 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. 200 mm perforated tray 16 SWG. |
| 467 | Supplying and laying HMS PVC conduit FRLS grade 450 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. 450 mm perforated tray 16 SWG. |
| 468 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 50 mm tray cover (18 SWG). |
| 469 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) 100 mm tray cover (18 SWG). |
| 470 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) 200 mm tray cover (18 SWG). |
| 471 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) 450 mm tray cover (18 SWG). |
| 472 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 473 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 474 | S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 475 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. |
| 476 | SUB- WORK - NO-9 Providing External CCTV Servilliance, Fire Detection and ELVWork For Bhimashankar Small Bus Stand at Nigdale Dist PuneSupplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. |
| 477 | Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP |
| 478 | Supplying, installing, testing and commissioning of addressable optical smokedetector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to32 V DC two wires supply, in-built locking mechanism to check the removal andpilferage of the detector, in built isolation mode, start up current 300μA and alarmcondition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C,humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/SD . |
| 479 | Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heattype detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area\"s etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 480 | Supplying, installing, testing and commissioning of intelligent addressablethermal/ heat detector with rate of rise cum fixed temperature thermistorcomplete with base as required, suitable for temperature variations from - 20°C to38 °C for fixed-heat and rate-of-rise type detectors whereas 0°C to 90°C for highheat type detectors, in built isolation mode, suitable for industrial/ kitchen/ boilerroom etc. with 3 years equipment replacement warranty, IS : 2175-1988reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 481 | Supplying, installing, testing and commissioning of addressable manual callpoints ( break glass type/pull station type), made of addressable break glassplastic square in shape surface/flush mounted with \"Break Glass\" massageembedded on the glass, complete erected with mounting base and requiredaccessories conforming to EN 54 or UL listed with 3 years equipmentreplacement warranty FF-AFAS/MCP. |
| 482 | Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 orUL Listed FF-AFAS/CRM |
| 483 | Supplying, installing, testing and commissioning of addressable fire monitormodule complete as required. EN 54 or UL Listed with 3 years equipmentreplacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relaysFF-AFAS/MM |
| 484 | Supplying, installing, testing and commissioning of addressable fire isolatormodule complete as required. EN 54 /FM or UL Listed with 3 years equipmentreplacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relaysFF-AFAS/ISM |
| 485 | Supplying, installing, testing and commissioning of addressable horn cumstrobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chartgiven in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operatingvoltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with3 years equipment replacement warranty FF-AFAS/SSH. |
| 486 | Supplying, installing, testing and commissioning of digital linear heat detectioncable addressable through monitor module with temperature ratings such as 60°-70°C, conforming to IS 2189: 2008, EN 54 or UL listed FF-AFAS/LHDC. |
| 487 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 488 | Supplying, installation , testing and commissioning of Priority Switching Module micro processor based for 16 ZONEwith suitable selection module (having key padfor zone selection with LCD display), power supply unit c/w battery, program timer etc. |
| 489 | Supplying, erecting, testing and commissioning 2000 W amplifier suitable tooperate on 230 Volts A.C. / 12 Volts D.C. supply complete as perspecification no. FF-PA/AFR |
| 490 | Supplying, erecting, testing and commissioning 15 to 30 Watts soundcolumn or ceiling mounted complete as per specification no. FF-PA/SOC |
| 491 | Supplying, erecting, testing and commissioning 15 to 30 Watts soundHorn Type mounted complete as per specification no. FF-PA/SOC |
| 492 | Supplying, erecting, testing and commissioning stand mounted/handheldtype wired microphone having 2 mV/Pa sensitivity, impedance level limit 300ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min.7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jackcomplete as per specification no. FF-PA/MIC |
| 493 | Supplying, erecting, testing and commissioning rust free microphone floorstand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mmheight and sturdy mechanism ensuring trouble free movement complete. |
| 494 | Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC |
| 495 | Rack of Approx. (600mm X 2100mm) high amplifier rack assembly made of aluminium channel equivalent to euro rack system, with side and rear panels made of 14 swg powder coated sheet steel front transparent persplexdoor and with rails, rollers & bearings. Fans shall provided at the top for ventilation side panels will be ventilated type. The rack shall be powder coatedof approved colour and spare \"U\" shall be covered with blank panels. |
| 496 | Supplying, Installing, Testing and Commissioning of Condenser gooseneck mic (cardioid), black, length 500 mm (18\"), two flexible segments, programmable switch (PTT, PTM, ON/OFF), Braille-marking, switchable illuminated ring, switchable low cut filter,3-pin XLR male, windscreen included with base. |
| 497 | Fire Alarm Control Panel (FACP) interfaces with other building systems, such as the Building Management System (BMS), via standard protocols like BACnet or Modbus, or proprietary interfaces, to exchange data and control functions |
| 498 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 499 | Providing, commissioning and maintaining temporary CCTV system with 66 channel NVR, IP video/audio input-1 no, IP based 4.0 MP, Full HD, IR IP dome camera - 2 nos, IP based 4.0 MP, Full HD, IR IP PTZ camera - 4 nos, 8TB Hard Disk - 2 no, 42\"\" Full H D professional display - 1 no, 16 port PoE Switch - 2 no, Power supply unit to camera - 1 no, On Line UPS - 1 no with necessary mains, switchgears on hire basis for one day. |
| 500 | Supply Installation, testing & commissining of Indoor type IP Dome Camera with 1/2\" 2 Mega Pixel progressive CMOS Sensor, integrated 2.8mm Fixed lens, 1080P high definition, Minimum Triple Stream Support, Inbuilt Smart IR LED upto 10m distance, 0.002 lux color/0 lux with IR LEDs on, H.265 profile, True WDR min 120 dB, True Day/Night, Built in Power over Ethernet (PoE), & 12VDC operated, inbuilt Micro SD Card Slot support min 64GB, Inbuilt face detection, motion detection, tampering alarm, ONVIF Profile S & G compliant, with Junction box & required accessories. |
| 501 | Supply Installation, testing & commissining of Indoor type IP Dome Camera with 1/2\" 2 Mega Pixel progressive CMOS Sensor, integrated 2.8~12.0 mm Varifocal motorized zoom lens, 1080P high definition, Minimum Triple Stream Support, Inbuilt Smart IR LED upto 10m distance, 0.002 lux color/0 lux with IR LEDs on, H.265 profile, True WDR min 120 dB, True Day/Night, Built in Power over Ethernet (PoE), & 12VDC operated, inbuilt Micro SD Card Slot support min 64GB, Inbuilt face detection, motion detection, tampering alarm, ONVIF Profile S & G compliant, with Junction box & required accessories. |
| 502 | Supply Installation, testing & commissining of Indoor type IP Mini Dome type Camera with 1/2\" 2 Mega Pixel progressive CMOS Sensor, integrated 2.8mm Fixed Lens, 2MP high definition, Minimum Triple Stream Support, Inbuilt Smart IR LED upto 10m distance, 0.002 lux color/0 lux with IR LEDs on, H.265 profile, True WDR min 120 dB, True Day/Night, Built in Power over Ethernet (PoE), & 12VDC operated, inbuilt Micro SD Card Slot support min 64GB, Inbuilt motion detection, tampering alarm, ONVIF Profile S & G compliant, with Junction box & required accessories. (to be installed Inside all Lifts) |
| 503 | Supply, installation, testing & commissioning of 1 set of Module (Transmitter & Receiver) for wireless communication for above camera (Wi-Fi / IP Based system) with required accessories.(for Lift camera integration) |
| 504 | Supply Installation, testing & commissining of Indoor / Outdoor type IP Bullet Camera with 1/2\" 2 Mega Pixel progressive CMOS Sensor, integrated 2.8~12 mm Varifocal motorized zoom lens, 1080P high definition, Minimum Triple Stream Support, Inbuilt Smart IR LED with 30m Distance, 0.002 lux color/0 lux with IR LEDs on, H.265 high profile, True WDR, True Day/Night), Built in Power over Ethernet (PoE) & 12VDC operated, inbuilt Micro SD Card Slot support min 64GB, Inbuilt face detection, motion detection, tampering alarm etc, ONVIF Profile S & G compliant, outdoor type (IP66 rated), Wall/Pole/Column mount brackets, junction Box & required accessories. |
| 505 | Supply Installation, testing & commissining of Outdoor type IP PTZ camera with 1/4\" 2 Mega Pixel Sony Pprogressive CMOS Sensor, 1080P high definition, 25X Optical Zoom lens, Focal Length 6 mm ~180 mm, Minimum Triple Stream Support, Inbuilt Smart IR LED with 150m Distance, 0.005 lux (color) / 0.0005 lux (B/W), 0 lux with IR LEDs on, H.265 profile, True WDR min 120 dB, True Day/Night), inbuilt Micro SD Card Slot support min 64GB, integrated pan tilt zoom accessories, pan speed upto 360 degree, Inbuilt Analytics- Face Detection, motion detection, alarm for camera disfocus /tampering/ move/ masking, ONVIF compliant, Waterproof (IP67 rated) housing, working temp -20°C to 55°C, mounting Brackets suitable for Pole / Wall mounting, 24V AC operated including Power Supply adaptor for camera & required accesories. |
| 506 | Supply Installation, testing & commissining of USB control 3-Axis Joystic for PTZ camera with required accessories. |
| 507 | Supply, installation, testing & commissioning of CCTV Profestional 24X7 operation, 365days, Wall mount 42\" Full HD Flat LED TV / Monitor having VGA & HDMI port with wall mount accessories. |
| 508 | Design, Fabrication, Supply and installation of Tubular G.I. Pole having 6mtrs height. using 100mm dia. pipe and 250x250mm,10mm thick base plate, for mounting with cable entry provisions from pole bottom and including arrangement for fixing of Bullet camera with brackets and required accessories, etc. The pole shall be painted with 2 coats of primer & bottom with black paint & 2 coat of silver paint etc. complete. (for outdoor camera) |
| 509 | Supply, installation, testing & commissioning of CCTV Surveillance Network Switch (Support 250 Meter Cat 6 cable length for Camera) Basic L2 features, 24 Port PoE auto-sensing 10/100/1000 Network Switch with 2X1Gb Uplink Ports including standard connectivity accessories. |
| 510 | Supply, installation, testing & commissioning of Basic L2 features, 24 Port NON PoE auto-sensing 10/100/1000 Network Switch with 2X1Gb Uplink Ports including standard connectivity accessories. (for common Data network) |
| 511 | Supply, installation, testing & commissioning of 6 Port Fiber LIU with Pigtails & required accessories. |
| 512 | Supply, installation, testing & commissioning of SC/LC type single mode Duplex Fiber Patch Cord with required accessories. |
| 513 | Supply, installation, testing & commissioning of CAT 6, 24 port Loaded Patch Panel with required accessories. |
| 514 | Supply, installation, testing & commissioning of CAT-6 patch cord - 1.0 meter (at rack side) |
| 515 | SITC of 1 Nos. RJ 45 socket outlet with back box & modular face plate at one place. |
| 516 | Supply & installation of 42U 600mm x 800mm Floor mount Rack with Front Glass Door, Fan Tray on Top, Perforated Rear Doors, Openable Entry at the Bottom for the Cable entry, Cable Basket for Cable Dressing & Vertical Power Strip with all necessary accessories & hardware. (Rack for mounting Network switches & NVR) |
| 517 | Supply & installation of 12U 600mm x 550mm Wall mount Rack with Front Glass Door, Fan Tray on Top, Perforated Rear Doors, Openable Entry at the Bottom for the Cable entry, Cable Basket for Cable Dressing & Vertical Power Strip with all necessary accessories & hardware. |
| 518 | Supply, installation, testing & commissioning of6 Core Single Mode Fiber Optic Cable, Outdoor Type with required end termination. |
| 519 | Supplying and installing cat-6 cable suitable for networking as per specificationno. WG-COC/NC |
| 520 | Supply, laying & testing of Cat 6 Armoured UTP cable including labelling and end termination with connectors both end. |
| 521 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 522 | Supply, fabrication and installation of readymade hot dip GI perforated type trays of following size with 50 mm depth unless otherwise specified including readymade accessories e.g. Vertical, horizontal bends, tee\"s, right angles, M.S. angle / channel supports for trays, frames etc.-50 mm perforated tray 16 SWG. |
| 523 | Supply, fabrication and installation of readymade hot dip GI perforated type trays of following size with 50 mm depth unless otherwise specified including readymade accessories e.g. Vertical, horizontal bends, tee\"s, right angles, M.S. angle / channel supports for trays, frames etc.-100 mm perforated tray 16 SWG. |
| 524 | Supply, fabrication and installation of readymade hot dip GI perforated type trays of following size with 50 mm depth unless otherwise specified including readymade accessories e.g. Vertical, horizontal bends, tee\"s, right angles, M.S. angle / channel supports for trays, frames etc.- 200 mm perforated tray 16 SWG. |
| 525 | Supply, fabrication and installation of readymade hot dip GI perforated type trays of following size with 50 mm depth unless otherwise specified including readymade accessories e.g. Vertical, horizontal bends, tee\"s, right angles, M.S. angle / channel supports for trays, frames etc.- 450 mm perforated tray 16 SWG. |
| 526 | Supply and installation of readymade hot dip GI tray covers fabricated from 16/18 SWG CRCA sheet including readymade shape of Vertical & Horizontal Bend, Tee\"s, Rightangles reducers etc. to suit tray for all vertical runs.-50 mm tray cover (18 SWG). |
| 527 | Supply and installation of readymade hot dip GI tray covers fabricated from 16/18 SWG CRCA sheet including readymade shape of Vertical & Horizontal Bend, Tee\"s, Rightangles reducers etc. to suit tray for all vertical runs. 100 mm tray cover (18 SWG). |
| 528 | Supply and installation of readymade hot dip GI tray covers fabricated from 16/18 SWG CRCA sheet including readymade shape of Vertical & Horizontal Bend, Tee\"s, Rightangles reducers etc. to suit tray for all vertical runs. 200 mm tray cover (18 SWG). |
| 529 | Supply and installation of readymade hot dip GI tray covers fabricated from 16/18 SWG CRCA sheet including readymade shape of Vertical & Horizontal Bend, Tee\"s, Rightangles reducers etc. to suit tray for all vertical runs. 450 mm tray cover (18 SWG). |
| 530 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 531 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 532 | Supply Installation Testing Commissioning of Automatic Boom Barrier 5 to 6 Meter length of below mentioned MakeMAKE : FAAC / CAME / EFA FLEX/ MARANTEC / RIB |
| 533 | Supply Installation Testing Commissioning of Vehicle Detection and Safety Loop for Barrier with the technical specification enclosed:-i)Two Loop Detectors shall be supplied with Boom Barrier to enable connection with induction loopsii)One of the loop is triggering loops which first detects the presence of vehicles and then alert the system and keeps its ready for entry/exit.iii) The other loop is closing/safety loops which activates the barrier to closewhen there is no vehicle over the loop. |
| 534 | Supply Installation Testing Commissioning of Long Distance UHF Reader (with read range from 06 to 10 Meters) & RFID 2 way controller complete in all respects as per site requirementMAKE : FAAC / CAME / EFA FLEX/ MARANTEC / RIB |
| 535 | UHF Vehicle Tag with read range from 06 to 10 Meter with operatingfrequency of 300 Mhz and 3 GHz |
| 536 | Supply Installation of Traffic Signal Light (Red + Green) at entrance/exit gate |
| 537 | Supply Installation of Welcome Display as per Specification enclosed |
| 538 | Supply Installation of Speed Bumps & Breakers [250 x 350 x 50mm] PVCCoated fitted with reflector for night vision for capacity up to 15 Tons. |
| 539 | Supply Installation Testing Commissioning of Safety Bollard x 36” Length ofHigh Quality |
| 540 | Supply and laying of 4C x 1.0 Sq.mm multistrand Copper, FRLS PVC insulated Flexible cable with required end termination. (for Boom Barrier, EM Lock etc.) |
| 541 | Supply & Installation of Tripod Turnstile & Control System |
| 542 | Supply & Installation of: Swing Turnstile & Control System for Handicapped persons:Make: CAME URBACO/AUTOMATIC SYSTEMS/Sunfre/FAAC/Housys/Autopass-India/ATTSystem/Vehant/Turnstar/ESSI. |
| 543 | Supply & Installation of: Central Management Server & Software (ACS-Turnstiles) with the following Configuration: 2U rack mounted Modular Server; Processor: Intel Xeon E5-2630v3 2.4GHz, 20MB Cache, 8 cores (with upgradability of 2nd Processor); RAM: 12 DIMM slots configured with 64GB DDR4 ECC RAM; 8x Hot-swappable SAS SATA or SSD drives; (HDD: 8x1TB or 4x2TB) 10K rpm 12Gbps SAS in RAID (Hardware 12Gbps RAID controller with support for RAID 0, 5, 6 & 10); DVD +/- RW; 2xPCIe 3.0, 2x10Gbps Base-T, 4x1Gb Base-T, 2x25 Gbps FC; RHEL, SLES, MS Windows Certification; Interactive LCD screen for display of error code; Intrusion alert in case chassis cover being opened; Display: Full HD 21.5 inch or higher; Display Viewing Angle: 178° vertical / 178° horizontal; Real time power meter, thresholds & alerts graphin, Historical power counter, Power Capping, Temperature monitoring & graphing. Dual SD Module slots in redundent configuration & auto synchonization of contents in the SD modules; Operating System: Preloaded Windows Server 2016.Make: DELL/HP/IBM |
| 544 | SITC of Biometricdevice and RFID card reader (Entry and Exit): Having following features;Built in controller with inbuilt multiple interfaceWi-Fi, LAN, 3G or higher version, DATA with auto negotiation,500000 event storage capacity, on-controller MAC ID synchronization, IP65,inbuilt interface for smart card , direct enrolment of finger and smart card from the controller, LAN/ MPLS /Internet auto-switching, contactless smartcard interface., inbuilt minimum 2.5 inch capacitive Touch Screen, pop up Photo , inbuilt USB port, inbuilt POE interface,external power source,in-built battery back up with minimum 2 hrs power support, min. 9000/ fingerprint support in 1:N mode and min. 100000 fingerprint in 1:1 mode . Template per user 10 finger print per user and 10 card per user, Protective Box for controller, 3G-dongle support with ISP charges for one year after commissioning, CE,FCC,ROHS,BIS certified, battery backup.MAKE: Matrix/ HID/ Suprema or any brand which will comply above specification. |
| 545 | Supply & Installation of: Customised Application Software having features :10000 Users expandable to 1 Million, Basic Access Control and Enrollment Management Software user License. Make: HID/MATRIX/Suprema/Greentech or equivalent.Warranty: 03 (THREE) years onsite Warranty. |
| 546 | Supply & Installation of: Access Control Module Software:Web based Application Software (open source type of the same OEM as that of controller) or any equivalent licensed software of third party certified by OEM, minimum 9000 Usersupgradable upto 1million users and 65000 controllers by adding necessary licence with comprehensive Time-Attendance configuration, multiple shift Management including night shift, Roster upload through excel file,Leave Management, Holiday Management, Attendance and Leave Policy Creation, past adjustment, manually leave correction, reports and chart generation, Scheduled report generation (daily attendance, Late attendance, Early out, habitual late punch report etc.) through mail, online leave application and approval, employee self log in for information of shift allocation, online leave application and status of available leave etc. Integration with Payroll (through API integration if permitted), Active Directory and HRM, Shift Schedule, Holiday Schedule and Past Adjustment, Manually Attendance Correction Leave /Tour Application and Approval, SMS and Email Notification, inbuilt facility to configure unlimited departments, multiple credentials for report generation, roster management and shift management, individual monitoring , unlimited client log in for individual departments for downloading monthly attendance report and all administrative configuration based on user rights ; support for different type of controllers (from the same OEM) without additional software licences. In-built Access control facilityon demand. |
| 547 | Supply & Installation of:Controller for Registration:Smart Card and NFC (Near Field Communication) Reader, Built-In Power over Ethernet (PoE), Tri Color LED and Buzzer.Make: HID/MATRIX/BOSCH/ ITECH/SSE/MRKDI/HIKVISION/TYCO/CP Plus/Mifare. |
| 548 | Supply & Installation of: RFID Smart Card: 1K (Blank); as per sample.Make: HID/MATRIX/BOSCH/ ITECH/SSE/MRKDI/HIKVISION/TYCO/Mifare. |
| 549 | Supplying and erecting modular type telephone socket two gang with safetyshutter, duly erected on provided plate and box with wiring connectionscomplete. |
| 550 | Analog CO/Trunk Lines: The number of connections for standard telephone lines. Digital Extensions: The maximum number of specific digital phones that can be connected. IP/VoIP Extensions: The number of network-based IP phones. ISDN/PRI/E1 Trunks: For high-capacity digital connections to the public network. GSM/3G/VoLTE Trunks: Connections for cellular communication. |
| 551 | Supplying, erecting & commissioning 50 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 552 | Supplying and erecting modular type computer Jack RJ45 with safety shutter,duly erected on provided plate and box with wiring connections complete. |
| 553 | Supplying and installing cat-6 cable suitable for networking as per specificationno. WG-COC/NC |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail