Repair Work District Office , Krishi Upaj Mandi,Chimanganj Ujjain , Repair Work District Office , Krishi Upaj Mandi,Chimanganj Ujjain , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceablematerial And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar15.6.3 , Steel Work In Built Up M.S. Tubular Section (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses/Frame Work Etc. Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. 10.14 .3 , Supply & Installation Of Silicon Modified Polymer Precoatedgalvanised Iron Profile Sheets (Size,Shape And Pitch Of Corrugationas Approved By Engineerin-Charge)0.50 Mm +/- 5% Total Coatedthickness (Tct) Thick Zinc Coating 120Gsm As Per Is: 277 In 240Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheetand Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches While Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge.The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55Mm) With Epdm Seal Or With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces Excluding The Cost Of Purlins, Rafters And Trusses Nd Including Cutting To Size And Shape Wherever Required.24.11 , Providing Corrugated G.S. Sheet Roofing Including Vertical/ Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00Mm Thick With Zinc Coating Not Less Than 275Gm/M² 12.1.1 , Providing And Laying In Situ Four Course Water Proofing Treatment With App (Atactic Polypropylene) Modified Polymeric Membrane Over Roof Consisting Of First Coat Of Bitumen Primer @ 0.40Kg Per Sqm, 2Nd And 4Th Courses Of Bonding Material @ 1.20 Kg/Sqm, Which Shall Consist Of Blown Type Bitumen Of Grade 85/25 Conforming To Is : 702, 3Rd Layer Of Roofing Membrane App Modified Polymeric Membrane 2.0Mm Thick Of 3.00 Kg/Sqm Weight Consisting Of Five Layers Prefabricated With Centre Core As 100Micron Hmhdpe Film Sandwiched On Both Sides With Polymeric Mix And The Polymeric Mix Is Protected On Both Side With 20Micron Hmhdpe Film. (With 5 Years Service Guarantee). , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottom Disposal Of Excavated Earth, Lead Up To 50M And Lift Up To 1.5M, Disposed Earth To Be Levelled And Neatly Dressed. (No Extra Lift Is Payable If Work Is Done By Mechanical Means) All Kinds Of Soil , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Upto Plinth Level : M-10 Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete (Nominal / Design Mix With 20Mm Nominal Size Graded Stone Aggregate) Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 5.1.1 M-20 M-20 Grade Concrete , Reinforced Cement Concrete Work (With 20 Mm Nominal Size Graded Stone Aggregate) In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Posts And Struts Etc. Above Plinth Level And Upto Floor Two Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement: 5.2.1 M-20 M-20 Grade Concrete , Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding Including Cost Of Binding Wire All Wastages And Overlaps, Couplers (Overlaps Shall Be Provided As Per Requirement Of Is 13920 For Ductile Detaling Is 456 Rcc Design & Sp 34 Reinforcement Detailing ) Etc. Complete . Thermo-Mechanically Treated Bars. Fe 500 Conforming To Is 1786. , Centering And Shuttering In Cluding Strutting, Propping Etc. And Removal Of Form For: , Foundations, Footings, Bases Of Columns,Etc. For Concrete Upto Plinth Level , Walls (Any Thickness) In Cluding Attached Pilasters Butter Esses, Plinth Beams And String Courses Etc. 5.9.2.1 , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Columns, P I L L A R S , Piers, Abutments, Posts And Struts. , Brick Work With Well Burnt 25Kg /Cm2 Chimney Bricks In Bulls Pattern Trench Kiln, Crushing Strength Not Foundation And Less Than 25Kg /Cm2 And Water Plinth Absorption Not More Than 20% In Foundation And Plinth I/C Curing Etc Complete. 6.3.2 Cm 1:6 Cement Mortar 1:6 (1 Cement:6 Sand). , Supplying And Filling In Plinth With Crusher Stone Dust / Coarse Sand Under Floors Including, Watering, Ramming And Compacting In Layers Not Exceeding , 12Mm. Thick Cement Plaster In C:M 1:6(1 Cement:6 Sand) , 15Mm. Thick Cement Plaster In C:M 1:6 (1 Cement:6 Sand) , Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/Ltr Of Approved Manufacturer, Of Required Shade And Colour Complete, As Per Manufacturers Specification. Two Or More Coat On New Work. 13.45 , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade: Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture. 13.65 , Finishing Walls By Any Mechanical Or Manual Means With Acrylic Smooth Exterior Paint (Economy Exterior) Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @1.67Ltr/10Sqm Over And Including One Coat Undiluted Exterior Waterproofing Coating @ 2.39 Litre/10 Sqm With Crack Bridging Ability Of Upto 0.5Mm On Horizontal Surfaces With An Elongation Of 150% And Water Proofing Of Upto 3 Bars On Vertical Surface , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : Old Work (Two Or More Coat Applied @ 1.67 Ltr/ 10 Sqm) On Existing Cement Paint Surface). , Providing And Fixing Of Factory Make Single Rebate Openable/Fixed Windows Made Of Roll Formed Galvanized Pre- Pained Steel With Epoxy Primer Of 5-7 Microns Thick, Finish Painted With A Polyester Paint Of 12-16 Microns Thick And Back Coated With Alkyd Backer 5-7 Microns Thick Or Powder Coated With Pure Polyester Powder Up To 50-60 Microns Thick, Colour Coated/Powder Coated (Base Steel As Per Is 513 Of “D Quality, Galvanized As Per Is 277 With Zinc Of 120 Grams/Sqm) Outer Frame Section 48 X 50 X0.58Mm, Centre Mullion Section 48 X 50 X0.58Mm, Shutter Section 47 X 20 X0.58Mm And The Fixed Glass Beading Section 12 X 12 X0.58Mm, Outer Frame And Mullions Shall Consists Rebate For Glazed Shutter With A 20 Mm Provision For Guard Bars/Grills And The Sections Cut To Length Mitre Joined With Corner Bracket, Centre Mullion Fixed With Mullion Cap, Handle, Stay, 2 Nos. Ss (Stainless Steel) Heavy Duty Pivot Hinges Per Shutter And Window Fitted Without Glazing (Glazing Shall Be Paid Separately As Per Sor Rate) With Epdm (Ethyl Propylene Diamine Monomer) Gaskets Including Fixing Frames In Concrete/Masonry Wall By Means Of Self- Expanding Screws, Including 10Mm Square Bars Welded To 6X12mm Flat At A Distance 150Mm C/C (Pitch) Etc. Including Filling The Gap Upto 5 Mm Depth And 5 Mm Width In Between Steel Frame And Adjacent Rcc/ Brick/ Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-Incharge Complete 10.39.1 , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2mm And Braced With Flat Iron Diagonals 20X5mm Size With Top And Bottom Rail Of T-Iron 40X40x6mm With 40Mm Dia Steel Pulleys Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. Rate Includes Recess Cutting In Floor And Making Good The Same Wherever Required. 10.3 , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete Including The Cost Of Providing And Fixing Necessary 27.5Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To I.S. 4454- Part-1 And M.S. Top Cover Of Required Thickness For Rolling Shutters. 80X1.20 Mm M.S. Laths With 1.20 Mm Thick Top Cover. , Providing And Fixing Ball Bearing For Rolling Shutters. 10.9