Tender For Addition / Alteration Of Bldg No 56 ( Otm Accn ) At Nahan Under Ge Chandigarh; 1.00 Demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) as in roofs, floors (other than ground floors) beams, slabs, staircases, landing, chajjas and similar suspended work complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. 2.00 Taking down Cement plaster or cement lime plaster on brick or stone walls including raking out joints, hacking for key & scrubbing down with water,cutting of trees,shrubs,any type of vegetation etc complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. 3.00 Taking down chowkhats or frames n.exc 1.5 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts complete all as specified and directed by Engineer-in-Charge. 4.00 Taking down chowkhats or frames exc 1.5 sqm but n.exc 4 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts etc complete all as specified and directed by Engineer-in-Charge. 5.00 Dismantling timber scantlings in in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section any location and any position complete all as specified and directed by Engineer-in-Charge. 6.00 Demolition of brick work or stone/boulder masonary built in cement mortar incl all quions arches, pillar or any other descrption etc complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. 7.00 Dismantling existing wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. 8.00 Demolition of cement concrete of any description and in any position including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. 9.00 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. 10.00 Dismantling boarding, any description, fixed in any position with nails including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. 11.00 Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. 12.00 Dismanting of mild steel of any description not otherwise provided for inany location and any position complete all as specified and directed by Engineer-in-Charge. 13.00 Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. 14.00 Taking up or down steel tubing and connections of 25mm bore in pipe, including cleaning for re-fixing or removal from site to store complete all as specified and directed by Engineer-in-Charge. 15.00 Taking up or down steel tubing and connections of 20mm bore in pipe, including cleaning for re-fixing or removal from site to store complete all as specified and directed by Engineer-in-Charge. 16.00 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel framesor stone, concrete or brick surrounds, glazed with putty or fixed with beads complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. 17.00 Dismantling of existing waterproofing treatment hessain cloth base,membrane or any other type complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. 18.00 Taking out old PVC (SWR )pipes 100 mm bore , jointed in cement mortar and taking out of trenches, if required including removal from site to store complete all as specified and directed by Engineer-in-Charge. 19.00 Taking out old PVC (SWR )pipes 75 mm bore , jointed in cement mortar and taking out of trenches, if required including removal from site to store complete all as specified and directed by Engineer-in-Charge. 20.00 Disconnecting existing tanks of capacity exc. 500 ltr & n. exc. 1000 ltr, setting aside and removing from site complete all as specified and directed by Engineer-in-Charge. 21.00 Cutting chases in stone walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good, cutting not exc 10 cm girth and complete all as specified and directed by Engineer-in-Charge. 22.00 Plain cement concrete (1:4:8) type D-2,using 40 mm graded stone aggregate as in foundations, filling and mass concrete, sub base etc complete all as specified and directed by Engineer-in-Charge. 23.00 75 mm thick, cement concrete type C-1, 1:3:6 using 40 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, complete all as specified.Plinth protection shall be laid in 1:20 slope and joint filling sealed with bituminous sealing compound grade A . 24.00 Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete complete all as specified and directed by Engineer-in-Charge.. 25.00 Forming Contraction (Dummy) joints 25mm deep x 10mm wide, filled with sealing compound Grade A complete all as specified and directed by Engineer-in-Charge. 26.00 Reinforced Cement Concrete nominal mix 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate as in slabs supported on walls, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge. 27.00 Reinforced Cement Concrete nominal mix 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified and directed by Engineer-in-Charge. 28.00 TMT steel bars 10mm dia and over, of grade Fe-500D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. 29.00 TMT steel bars 6 mm to 8mm dia and over, of grade Fe-500D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. 30.00 TMT steel bars 5 mm dia and over, of grade Fe-500D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified and directed by Engineer-in-Charge. 31.00 Use & waste of Formwork to to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge. 32.00 Use & waste of Formwork to to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge. 33.00 First quality Non - skid coloured Ceramic tiles 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge. 34.00 First quality Non - skid coloured Ceramic tiles 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge. 35.00 First quality Non - skid coloured Ceramic tiles 8 mm thick (square/ rectangular) area of each tile exceeding 0.42 sqm but not exceeding 1.0 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge. 36.00 Glazed ceramic coloured tiles 450 x 350 x 7 mm thick on vertical surface such as skirting , dado etc. over and including 10 mm thick rendering in CM 1:4 thick set and jointed with 4 mm spacer and grouting the joint of wall with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 complete all as specified and directed by Engineer-in-Charge. 37.00 Machine cut Kota stone slab flooring 22-25 mm thick,SIZE 55 CM x 55 cm laid over & including 20 mm thick screed bed in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and directed by Engineer-in-Charge. 38.00 Machine cut Kota stone slab 22-25 mm thick as in skirting,steps, dado and pillars etc , laid over & including 10 mm thick rendering in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and directed by Engineer-in-Charge. 39.00 Cutting,grinding and mirror polishing of Kota stone / Marbe stone in floors,treads of steps complete all as specified and directed by Engineer-in-Charge. 40.00 Cutting,grinding and mirror polishing of Kota stone / Marbe stone in skirting,risers of steps complete all as specified and directed by Engineer-in-Charge. 41.00 Granite jet black shade, 18-20 mm thick, (table rubbed and polished) in single piece (in one direction) machine cut, machine polished, bedded and jointed with adhesive suitable for granite/stone & pointed with grout of matching shade including necessary cutting over & including 20 mm thick (average thickness) cement mortar (1:4) screed and jointed with grey cement mixed with matching shade pigment including rounding of/moulding to edge (half round ) as in cooking platform, shelves, RCC counters, window cills,jamb,cill,step & riser, similar situations, complete all as specified and directed by Engineer-in-Charge. 42.00 Brick work with sub class B bricks, class designation 100, old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. 43.00 Water proofing roof treatment/sunken treatment using APP polymeric water proofing membrane minimum 3 mm thick and weighting not less than 3.6 Kg/Sqm black finish reinforced with non-woven polyster matt wt not less than 150 gms/Sqm with thermo fusable finish laid over compatible bitumen primer at the rate of 0.40 Ltr/Sqm over cleaned surface including parapet,applying a coat of blown bitumen 85/25 grade @ 1.2 kg per square metre over priming coat torching over laps with a propane or butan gas torch with a over lap of 100 mm at the side and 150 mm at the ends and sealing all as per manufacturers instructions incl wire brushing and cleaning the top surfaces of concrete, roof surfaces etc. with water including flashings and junction of parapets etc complete all as specified and directed. 44.00 Rendering 20 mm thick in cement mortar 1:6, on fair faces of stone or concrete surfaces in patches , trowelled to even and smooth surface without using extra cement, complete all as specified and directed by Engineer-in-Charge. 45.00 Rendering 15 mm thick in cement mortar 1:4 on on fair faces of stone or concrete surfaces etc in patches mixed with water proofing compound finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. NOTE: Water proofing compound shall be measured and paid separately. 46.00 Rendering 20 mm thick in cement mortar 1:4 on on stone masonary surface,brickwork or other than fair faces ,one side of lathing mixed with water proofing compound finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. NOTE: Water proofing compound shall be measured and paid separately. 47.00 Rendering 5 mm thick in cement mortar 1:3 as in ceiling/soffits of slabs/Chajja/ Sunshade finishing the plastered surface even & smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge. 48.00 Supply only liquid water proofing compound ISI Marked complete all as specified and directed. 49.00 Preparation of new plastered surfaces of wall and applying 1 mm thick white cement based wall care putty iafter applying emery paper or sand paper complete all as specified and directed. 50.00 Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper on walls over and including a coat of alkali resistant primer complete all as specified and directed. 51.00 Preparation of new external surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces in camouflaging pattern or in any other pattern upto 2nd storey bldg all as per manufacturers instructions etc complete all as specified and directed by Engineer-in-Charge. 52.00 Preparation of plastered or unplastered new surfaces of ceilings and applying three coats of white wash including preparation of surface complete all as specified and directed by Engineer-in-Charge. 53.00 Providing & fixing false ceiling at all heights with fully perforated GRG (Glass Fibre With Reinforced Gypsum) false ceiling tiles of perforated Size 595 x 595 mm of approved texture, 12mm thick micro tegular edged or 10 mm square edged GRG false ceiling tiles ,design and patterns having moisture content less than 2%, humidity resistance edged of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items(galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 tiles fully mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specificationsand as per directions of the Engineer-inCharge. 54.00 Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators,casements/sliding shutters and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with rawl plugs and screws or with fixing clips or with expansion hold fastener of required dia and size, including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall not be less than 2 mm thick,smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,hinges/pivot and making provision for fixing of fittings wherever complete all as specified and directed by Engineer-in-Charge. Note :1. The rate is inclusive of rollers,Maruti locks/star locks,rubber beading,rubber seal etc for sliding / casement shutters 2. Panel fillings other than aluminium and necessary fittings shall be measured and paid for separately 55.00 Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) 56.00 Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engineer-in-Charge. 57.00 19mm thick plywood BWR type BB, fixed with screws to timber frame work as in kitchen cabinets , cupboards etc, fixed in repair with lipping / frame to match complete as specified and directed by Engineer-in-Charge. 58.00 1 mm thick sunmica (Coloured ) fixed with adhesive over plywood surface and wooden surface to match complete as specified and directed by Engineer-in-Charge. 59.00 PVC hollow wall panelling 5 mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site including cover fillets complete all as specified and directed 60.00 Aluminium composite panel 4 mm thick as decorative choice fixed in aluminum panels of standard size as required at site complete all as specified and directed 61.00 Supply and fixing of stainless steel butt hinges 100 mm long anodised type C-21 fixed with stainless steel screws or welding to existing MS frames complete ,all as specified and as directed by Engr-in-charge. 62.00 150 mm long stainless steel D type handles, with back plate fabricated type,anodised complete all as specified and directed by Engineer-in-Charge. 63.00 75 mm long stainless steel handle fancy type fixed in position with stainless steel screws ISI marked suitable for rubber wood shutter drawer complete as per sample kept complete all as specified and directed by Engineer-in-Charge. 64.00 Stainless steel barrel tower bolts of extruded section with length of bolt 150 mm and dia of bolt not less than 12 mm,ISI marked complete all as specified and directed by Engineer-in-Charge 65.00 Stainless steel sliding bolts of extruded section with length of bolt 250 mm and dia of bolt not less than 12 mm,ISI marked complete all as specified and directed by Engineer-in-Charge 66.00 Door stopper 75 mm single legged with rubber shoe fixed to door shutter with screws complete all as specified and directed by Engineer-in-Charge. 67.00 Door closer hydraulically regulated,Aluminium body (Die cast ) designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by Engineer-in-Charge. 68.00 Continuous (piano) hinges,stainless steel Grade -304, bright finish or electrogalvanised 30 mm width of flap when open complete all as specified and directed by Engineer-in-Charge. 69.00 Magnetic catchers 50mm long superior quality ,fixed with stainless steel screws to PVC/Wooden moulded shutters frame work in kitchen cabinets,cupboards etc complete all as specified and directed by Engineer-in-Charge. 70.00 Supply and fixing in repair door strip (snake guard strip ) min 18 mm wide aluminium body and nylon brushes min 22 mm wide alongwith screw fixing complete ,all as specified and directed by Engineer-in-Charge. 71.00 Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws,hooks etc complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE 72.00 Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410 (Gde E-250) complete all as as specified and directed by Engineer-in-Charge. 73.00 Mild Steel Framed work as in guard bars/grills, gratings, etc.. with ends of bars shouldered/welded and/or riveted, or forged into spikes; framed guard bars/grills conforming to Fe-290 (Gde E-165) complete all as as specified and directed by Engineer-in-Charge. 74.00 Sheet glass 4.0 mm thick, ordinary quality and glazing with silicon sealant & spring glazing clips using Silicon for fixing of glass in addition to glazing putty, in squares not exceeding 0.5 Sq. mtr in each pane, complete all as specified and directed by Engineer-in-Charge. 75.00 4.0 mm thick figured glass pin head type and glazing with silicon sealant in square not exc 0.5 sqm each and using Silicon for fixing of glass in addition to glazing putty complete all as specified and directed by Engineer-in-Charge. 76.00 Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge. 77.00 25mm dia stainless steel fancy type drapery rod of wall thickness 0.9 mm with fixed brackets,stops and rollers including taking out of old pelmet/bracket, complete all as specified and directed by Engineer-in-Charge. 78.00 Stainless steel bracket and stainless steel fancy type fennel complete all as specified and directed by Engineer-in-Charge.Note: The quoted rate includes one pair comprising of two brackets and two fancy type fennels. 79.00 Preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. 80.00 Preparation of old or previously treated steel and iron surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge. 81.00 Supplying and fixing in repairs Vitreous China squatting pan of “Orissa Pattern” of size 580x440mm white with integral footrest complete white including 10 ltr capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve float and handle with brackets complete all as specified and directed by Engineer-in-Charge. Note : The quoted rate shall include provision of P or S trap. 82.00 Supplying and fixing in repairs Vitreous China Wash down water closet floor mounted one piece white including 10 ltr capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve float complete all as specified and directed by Engineer-in-Charge. 83.00 Vitreous China urinals,half stall urinal type white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engineer-in-Charge. 84.00 Vitreous china urinal partition white of size 310x700 mm.complete all as specified and directed by Engineer in Charge. 85.00 Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms).complete all as specified and directed by Engineer in Charge. 86.00 Supplying and fixing in repairs vitreous china counter top wash hand basin in square /round /rectangular shape of standard size including chromium plated waste coupling, waste pipe etc., (incl all waste fittings) complete all as specified and directed by Engineer-in-Charge. 87.00 Supplying and fixing in repairs 15 mm fancy type chromium plated Pillar taps mixture type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed screwed down suitable for 15mm bore pipe or union complete all as specified and directed by Engineer-in-Charge. 88.00 Supplying and fixing in repairs 15 mm fancy type chromium plated fancy type bib tap brass long body with flange screwed down high pressure CP cast copper alloy with crutch or butterfly handles screwed down suitable for 15mm bore pipe or union complete all as specified and directed by Engineer-in-Charge. 89.00 Supplying and fixing in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-Charge. 90.00 Supplying and fixing in repairs Brass chromium plated shower rose 125mm size including making connections and fixed in position complete all as specified and directed by Engineer-in-Charge. 91.00 Supplying and fixing in repairs type stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, all as specified, of 15mm bore, fancy type, chromium plated with long shank and cup (Concealed type) complete all as specified and directed by Engineer-in-Charge. 92.00 Supplying and fixing in repairs fancy type stop valves/Angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, all as specified, of 15mm bore, fancy type, chromium plated with long shank and cup complete all as specified and directed by Engineer-in-Charge. 93.00 Supply and fixed in repair stainless steel towel ring, 150 mm dia round shape with peg set complete all as specified and directed by Engineer-in-Charge. 94.00 Supply and fixed in repair brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flangescomplete all as specified and directed by Engineer-in-Charge. 95.00 Supply and fixed in repair corner shelf 225 x225 mm of 6 mm thick toughened glass polished edged.Frame shall be of brass chromium plated tubing with brushed finish.Shelves shall be supported by adjustable shelf supports for a weight capacity of 15 Kg. Shelf shall be installed using appropriate anchors for wall complete all as specified and directed by Engineer-in-Charge. 96.00 Supply and fixed in repair toilet paper holder with flat recessed type stainless steel complete all as specified and directed by Engineer-in-Charge. 97.00 Supply and fixed in repair chromium plated brass jet spray with flexible tube 1.5 mtr complete all as specified and directed by Engineer-in-Charge. 98.00 PVC connections 15mm size with PTMT nuts of length 450 mm fixed in repair complete all as specified and directed by Engineer-in-Charge. 99.00 Supply and fixed in repair Brass chromum plated wall mixer for mixing hot and cold water fancy type with screwed down for 15mm dia iron pipe complete all as specified and directed by Engineer-in-Charge. 100.00 Supply and fixed in repair 5 mm bevelled edge looking mirror of selected quality glass, mounted on 12mm thick marine plywood with eatching alround and fixed with wooden plugs, chromium plated screws, cup and washers complete all as specified and directed by Engineer-in-Charge. 101.00 Supplying and fixing in repairs waste pipe 32 mm dia,800 mm long flexible for Sink and WHB complete all as specified and directed by Engineer-in-Charge. 102.00 Supplying & fixing of PVC water storage tank 1000 ltr capacity HDPE triple layered ,white colour cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection incl locking arrangement, including 15/20 mm GI nipples and supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight 200 mm - 210 gms ) complete Note : (i) Inlet, outlet & wash out pipe will be measured paid for separately. (ii) The quoted rate is inclusive of minimum one union each on inlet and outlet of water tank as per size of pipe shall be provided. 103.00 PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore fixed in repair including jointing to waste pipe in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer in Charge. 104.00 PVC (SWR) P’ trap 125 /110 mm bore fixed in repair complete all as specified and directed by Engineer in Charge. 105.00 75mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamps made out of flat iron of size 25 mm x 3 mm including nuts,bolts complete all as specified and directed by Engineer-in-Charge. 106.00 110 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamps made out of flat iron of size 25 mm x 3 mm including nuts,bolts complete all as specified and directed by Engineer-in-Charge. 107.00 PVC(SWR) bends (any radius), for 75 mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge. 108.00 PVC(SWR) bends (any radius), for 110mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge. 109.00 CPVC(SDR-11) pipes of outer dia 25 mm with and including CPVC SDR-11 brass and plain fittings on walls and ceilings or laying in floors complete all as specified and directed by Engineer-in-Charge. 110.00 CPVC(SDR-11) pipes of outer dia 20 mm with and including CPVC SDR-11 brass and plain fittings on walls and ceilings or laying in floors complete all as specified and directed by Engineer-in-Charge. 111.00 Ball valvesCPVC (SDR 11)of diameter 25 mm bore complete all as specified and directed by Engineer-in-Charge. 112.00 Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule of diameter 25 mm bore complete all as specified and directed by Engineer-in-Charge. 113.00 INTERNAL ELECTRIC SUPPLY WORKS 114.00 Taking down Copper/Aluminium point wiring (light, fan, socket or power) complete, any type / size complete with removing all connection and accessories, fittings and fixtures such as switches , sockets, ceiling rose,pendent holder,fan regulator any type , all type of tube light fitting , batten , steel or PVC conduit , casing caping etc compele and making good the disturbed surface of wall , floor etc. complete all as specified and directed by Engineer-in-Charge. Note :-- Rates for cutting/chases in walls and making good disturbed area deemed to be included in the quoted rate 115.00 Taking down existing unserviceable sub main wiring with 2 Runs/4 Runs of 2.5/4/6/10 Sqmm aluminum/copper cable all as directed by Engr-in-charge. 116.00 Taking down existing unserviceable MCCB incommer DB/MCB DB/AC box /Meter box of any size and disposal under schedule of credit,and making good disturbed area all as directed by Engr-in-charge. 117.00 Point wiring using approved colour coding as per IS ,with stranded copper conductor 1.5 sqmm (nominal area ) single core , flame retardant low smoke and low halogen FRLSH PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,marked TEC and FIA approved in and including PVC conduit medium grade ISI marked 20mm dia with all fittings and accessories, concealed type/ surface type (surface type only on ceiling), PVC junction boxes, modular metal sunken/flush boxes of any modules from 2 to 18 Modules with Inner and outer modular cover plates, including FRLSH flame retardant low smoke and low halogen rigid PVC insulated unsheathed stranded copper conductor 1.5 Sqmm (nominal area )single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed by Engr-in-charge.Note :- 1. Cutting/chasing of wall etc. deemed to be included in the quoted rate of this item. 2. Modular metal flush/sunken Box along with modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 3. Only switch socket and fan regulators to be measured and paid separately 118.00 (a) One light point controlled by one switch or one (Ceiling/ Wall/ Exhaust) fan point ,bell controlled by one switch and regulator 119.00 (b) One 3 pin 5 Amps socket outlet on independent board 120.00 (c ) One 3 pin 5 Amps socket outlet on same board with other switches 121.00 Point wiring using approved colour coding as per IS ,with stranded copper conductor 4 sqmm (nominal area ) single core , FRLSH flame retardant low smoke and low halogen PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,marked TEC and FIA approved in and including PVC conduit medium grade ISI marked 20mm dia with all fittings and accessories, concealed type/ surface type (surface type only on ceiling), PVC junction boxes, modular metal sunkun/ flush boxs of any modules from 2 to 18 Modules with Inner and outer modular cover plates, including FRLSH flame retardant low smoke and low halogen rigid PVC insulated unsheathed stranded copper conductor 2.5 Sqmm (nominal area )single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed by Engr-in-charge.Note :- 1. Cutting/chasing of wall etc. deemed to be included in the quoted rate of this item. 2. Modular metal flush/sunken Box along with modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 3. Only switch, socket and fan regulators to be measured and paid separately 122.00 Modular snap Switch one way 6 Amps one module complete all as specified and directed. 123.00 Modular snap Switch one way 16 Amps one module complete all as specified and directed. 124.00 Modular Socket 6 Amps 5 Pin 2 Module complete all as specified and directed. 125.00 Modular Socket 6/16Amps 5 Pin 2 Module complete all as specified and directed. 126.00 Modular AC box MCB protected socket 4 module plastic box with 25 A power unit complete all as specified and directed. 127.00 Modular blanking plate suitable for 1 Module complete all as specified and directed 128.00 Modular fan Regulator step electronic type 2 module complete all as specified and directed. 129.00 Ceiling rose surface backlite 65 x 20mm size three terminalcomplete all as specified and directed. 130.00 Lamp holder, PVC/ Polycarbonate type with back plate with and including one no of LED bulb 15 watt Base-22 retrofit type complete all as specified & directed. 131.00 LED indoor light fitting 1x 22 Watt, 220V,AC decorative box type for fixing on ceiling / wall with aluminium base directly including retrofit LED tube light colour cool day light 4 ft wide operating voltage 140-270 connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including 20 watt LED tube rod complete all as specified and directed. 132.00 Surface mounted wall mirror LED light Compact & sturdy 10 watt LED decorative fixture with anti glare polycarbonate diffuser, multi purpose lighting solution & applications .all accessories & fixtures, internally prewired and connecting by providing copper flexible wire 23/.0076 mm twin core upto fitting, complete all as specified and directed. 133.00 10W Bulk head LED luminaries Die cast aluminium alloy body ,heat resistent prismatic glass cover ,with specially designed gasket incl all accessories & fixtures, internally prewired and connecting by provding copper flexible wire 23/.0076 mm twin core upto fitting, complete in all respects complete all as specified and directed by Engineer-in-Charge. 134.00 Security Light LED 35 Watt made up of pressure dia cast Alumunium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including sevice bracket of GI pipe 32mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required as site and making electrical connection, complete all as specified and directed. 135.00 Post top lantern LED Nebula type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 136.00 LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.internally prewired and connecting by providing copper flexible wire 23/.0076 mm twin core upto fitting, complete all as specified and directed. 137.00 25W LED batten with opal diffuser,IP 20,battery backup upto 4 hours (Fitting should have inbuilt 2 Nos of Li-on battery of 2600 mA each) .Housing of fixture should be of extruded aluminium efficacy of fixture >100 LPW,P>F>0.9,THD<30% complete in all respects complete all as specified and directed by Engineer-in-Charge. 138.00 Round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete., complete all as specified and directed. 139.00 Sub main wiring using approved colour coding as per IS with two runs of 6 sqmm PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor with one run of 6 sqmm (green colour) PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor as earth wire connected to common earth dolly with thimbles, drawing into & including PVC Concealed conduit ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc all as specified and directed.Note: (i) Three runs ( main ) of 6.00 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose. 140.00 Sub main wiring using approved colour coding as per IS with two runs of 4 sqmm PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor with one run of 4 sqmm (green colour) PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor as earth wire connected to common earth dolly with thimbles, drawing into & including PVC Concealed conduit ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc all as specified and directed.Note: (i) Three runs ( main ) of 4.00 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose. 141.00 Sub main wiring using approved colour coding as per IS with two runs of 2.5 sqmm PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor with one run of 2.5 sqmm (green colour) PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor as earth wire connected to common earth dolly with thimbles, drawing into & including PVC Concealed conduit ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc all as specified and directed.Note: (i) Three runs ( main ) of 2.5 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose. 142.00 Vertical Distribution Board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/S 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 125 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. 143.00 Distribution Board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, 12 way SPN, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections complete all as specified and directed. 144.00 Distribution Board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, 8 way SPN, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections complete all as specified and directed. 145.00 Distribution Board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, 4 way SPN, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections complete all as specified and directed. 146.00 SPN AFDD 16A/32A/40A offering protections for overload, short circuit, Residual current characterisitics TYPE A, Over Voltage protection above 270 AC plus minus 5% & series parallel arc fault. AFDD must be dual test button for AFDD and Earth leakage functions along with single diagnostic LED with blinking patterns for continuous ON, Series Arc, Parallel arc and overvoltage protection complete all as specified and directed. 147.00 ISOLATOR TPN 63 Amp,415 volts,50Hz, 10KA, C series ISI marked as incoming and outgoing controlling circuit all as specified and directed. 148.00 ISOLATOR DP 40-63 Amp,240 volts,50Hz, 10KA, C series ISI marked as incoming and outgoing controlling circuit all as specified and directed. 149.00 ISOLATOR SP 6- 40 Amps, 220 volts , 50 Hzs, 10 KA , C series, ISI marked all as specified and directed. 150.00 XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 16 sq. mm, 4 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified. 151.00 Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, 8cm in depth before laying the cable and 15 cm in depth after laying the cable including spreading, levelling and consolidation complete all as specified and directed. Note : Consolidated/punned sand shall be measured for payment purpose. 152.00 Supply and laying burnt bricks sub class B old size for cable protection laid flat length perpenducualr to the axis of cable complete all as specified and direted by Engineer-in-Charge. 153.00 GI pipes light grade size 40 mm dia for protection of UG cable,road crossing, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified. 154.00 Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009) complete all as shown on drawings and as specified and directed by Engineer-in-Charge.Note : The unit rate includes for protecton pipe 15mm and GI earth strip 4mm from top of earth plate upto 7.50 metre above ground level. 155.00 COMMON ITEMS 156.00 Excavation in trenches in any type of soil not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth; for foundation or for shafts, wells, cesspits, manholes, pierholes, etc. not exceeding 10 sq. m on plan and getting out complete all as specified. 157.00 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick each,excavated soil in soft/loose soil, complete, all as specified and directed by Engineer-in-Charge. 158.00 Removing of surplus soil/ excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and directed by Engineer-in-Charge.