| 1 | Material and labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC (FR) insulated cable in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.5 Sqmm insulated un-sheathed PVC insulated copper conductor common earth and connecting to earth dolly for :- |
| 2 | One light/fan point controlled by one, one way switch |
| 3 | One socket outlet 3 Pin, 5 Amp on independent board |
| 4 | S&F of switch piano flush type single pole one way 6 Amp (ISI Marked) Make - Havells/Schnider/Legrand |
| 5 | S&F of socket out let 2 in 1, 3 pin 5 Ampflush type (ISI Marked) Make - Havells/Schnider/Legrand |
| 6 | M&L for ceiling rose, surface bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate, isolated body (ISI Marked) |
| 7 | Supply and fixing ceiling fans completewith blades, down rods, electronicregulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFMwith service value 6.00 BEE. Five starrated with brushless direct current motor(BLDC) and connecting up and including provision of twisted three core PVC insulated flexible cord of 0.75 Sqmm copper conductor of required length from ceiling rose/connector to fan complete all as specified and directed. |
| 8 | Supply & fix electronic type fan regulator stepped type on existing phenolic laminated sheet etc. suitable for ceiling fan complete all as specified and directed. |
| 9 | Supply and installation and testing ofdesert cooler electric driven (Single phase) for rooms up to 35 Sqm, large pad area for superior cooling, powerful fan , water tank capacity 51 ltrs complete all as specified and directed with following specifications :-Size of Desert Cooler :- L x b x h 660 x 660 x 825 mm (26\" x 26\" x 32.5\") ApproxFan Motor : (i) Fan motor should be copper winding, 500 mm Sweep Cooler fan, three speed (High/Medium/Low) with methalic blade duly painted with Snthetic anti corrosive oven cured paint fitted to body Fan motor Make : Bajaj/Khaitan/Crompton Greaves/GEC (ii) Input Cap 200 watt(approx), Speed 1400 RPM, 230 Volts, 50 Hz, Air Delivery 5000 Cum/HrsSubmersible Pump Motor : Input Cap 40 watt (Approx), Speed 1300 RPM, 230 volts, 50 Hz.Switches/Regulator : One Piano Switch and one Speed Selector Switch (Regulator) 04 Position for controll of Pump Motor and Fan motor respectively will be provided on the body.Pads : Wood wool Pads of proper Thickness will be provided in each panel (Set of three).Drain Plug : Brass drain plug shlall be provided from pump motor to three panel fitted on the cooler body.Cord : Flexible cord PVC Shethed and Insulated size 40/0.25 mm (1.5 Sqmm) 3 core (as per IS 694/1977) length 5 Mtr long with three pin 5 Amp ISI marked Bakelite plug Top shall be provided for power supply to cooler.Note : (i) All Desert cooler should be fitted on first floor or second floor minium height is 8 mtr (ii) Contrctor should be provide all Safty material for worker for installation of Desert Cooler (iii) Contrator should be submitted 01 year Guarntee/Waranty of Desert Fan motor and submersibale pump Motor.(iv) The rate forcooler stand made up from Angle iron 40x40x5mm size are deemed to be included in the quotad rate. |
| 10 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying C/GI pipe complete all as specified and directed by Engineer-in-Charge. Note : Earth work for taking out existing pipe line shall be done after testing commisioning of new pipe line. |
| 11 | Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed. |
| 12 | Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 13 | Taking down 100 mm bore Cl pipe line from trench stacking it reuse or issued to contrctroctor as credit of following sizes Note :- Ttaking out existing pipe line shall be done after testing commisioning of new pipe line complete all as specified and directed. |
| 14 | - ditto- all as per item No. 11 above but CI pipe 150 mm bore complete all as specified and directed. |
| 15 | - ditto- all as per item No. 11 above but CI pipe 200 mm bore complete all as specified and directed. |
| 16 | Refixing old 100 mm bore CI pipe retrived from srviceable Cl pipe line of any description in trench complete all as specified and directed. |
| 17 | - ditto- all as per item No.12 above but CI pipe 150 mm bore complete all as specified and directed.2 |
| 18 | - ditto- all as per item No. 12 but above but CI pipe 200 mm bore complete all as specified and directed. |
| 19 | S&F of DI 100 mm bore pipe K9 in any length laid in trench and connecting up with water supply main |complete including jointes complete all as specified and directed. |
| 20 | - ditto- all as per item No. 13 but above but DIK9 pipe 150 mm bore complete all as specified and directed. |
| 21 | - ditto- all as per item No. 13 but above but DIK9 pipe 200 mm bore complete all as specified and directed. |
| 22 | S&F in replacement cast iron fitting such as bends, tapers, (any type, radius and angle) tapers any type, (straight, bend, increasing,decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs tee pieces, singlebranch for spigot and socket and flanged pipe up to 150 mm bore complete all as specified and directed. |
| 23 | S&F in replacment cast iron sluice valve 80 mm bore with flanged ends, ISl mark with Gun metal spindle, Cl gate with brass ring and iron wheel handle with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S slice valve complete all as specified and directed. |
| 24 | - ditto- all as per item No. 15 but here in before but 100 mm bore complete all as specified and directed. |
| 25 | - ditto- all as per item No. 15 but above but above here in before but 200 mm bore complete all as specified and directed. |
| 26 | M&L for valve pits of internal dimensions 90cmx 90 cm x 90 cm making good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces CM 1:6, 15mm thick and PCC coping in cement concrete |1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angie iron frame 35x35x5mm including frame work as per existing size with two coats of synthetienamel paint over a coat of red oxide primer complete all as specified and as directed. (a) M&L for brick work using sub class \"B\" (old size bricks) in cement mortar 1:4 (b) M&L for rendering 15 mm thick in cement mortar |1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetienamel paint overa coat of red oxide primer to untreated steel surface & prep of surface. |
| 27 | M&L for lead joint suitable for Cl pipe 80 mm bore Gomplete all as specified and directed. |
| 28 | M&L for lead joint suitable for CI pipe 100 mm bore complete all as specified and directed. |
| 29 | M&L for lead joint suitable for Cl pipe 200 mm bore complete all as specified and directed. |
| 30 | M&L for plain cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in block mass concrete below and above the ground level for resting pipe line all as specified and directed. |
| 31 | Excavation in trenches n.exc 1.5m deep & n.exc1.5m wide on plan in soft/loose soil and getting out. |
| 32 | M&L for plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete all as specified. |
| 33 | Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil. |
| 34 | Removing excavated material n exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point. |
| 35 | M&L for brick work with sub class \"B\" Bricks straight or curved on plan exc 6m Mean radius built in cement mortar 1:4 complete all as specifiedas directed. |
| 36 | M&L for providing precast cement concrete 1:2:4 as in man hole covers type B-1 (20 mm graded agg) as in manhole cover set in cement mortar 1:6 ,including necessary form work complete all as specified and directed by the Engineer in Charge. |
| 37 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia. |
| 38 | M&L for TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia. |
| 39 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting outexisting benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm bore drain pipe complete all as specified and as directed. |
| 40 | M&L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:4 finished fair and even complete all as specified. |
| 41 | M&L for concrete bed to drain pipes 300mm bore in cement concrete (1:3:6) type D-2 (using 20mm graded stone aggregate) including forming cradels with concrete after they are laid and testedcomplete all as specified and directed. |
| 42 | M&L for 300mm bore RCC pipe class NP2 laid and jointed complete with collars laid in trenches and tested complete all as specified and directed. |
| 43 | M&L for cement concrete in 1:2:4 (type B0 12.5 mm stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided forwater troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 44 | RCC Septic tankfor 50 users designed to carry sewage and sullage water, excavation in any type of soil,PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, base slab, baffle wall, roof slab including beams etc vent shaft, manhole openings with cover connection etc complete with effective dept of 1.5m and over all depth of 3.0m or more as specified in drawing provided during excecution complete all as specified and directed. |
| 45 | Soakage well size3.6 M dia X 3.0 M effective depth , excavation in any type of soil, foundation in PCC 1:3:6 , walls honey combed masonary with top ring of M-25 concrete including intercepting chamber ans screen chamber made of brick masonary in CM, RCC cover slab in M-25/ SFRC cover , interconneecting pipes of PCC/DWCPE filled wth brick bats inside as per the drawing provided during the time of execution complete all as specified and directed. |