| Sl. No. | Item Description |
| 1 | RCC UG SUMPProvision of semi UG sump of 30000 gallons with RCC framed construction including inlet and outlet DI pipe connections to existing pipe lines complete all as per specified in drawing No TD/ST/750 Sheet 1/4 to 4/4 and as directed. |
| 2 | PUMP HOUSEMaterial and labour for construction of pump room with single storey framed structure of 25 Square Metre complete all as per specified in drawing No TD-610 Sheet 1/5 to 5/5 and as directed.NOTE: Rtae quoted for Pump Room shall be excluding Internal Electric Supply and Internal Water Supply and items for such services shall be measured and paid separately under relevant of items of BOQ catered hereafter. |
| 3 | RETAINING WALL |
| 4 | Excavation by mechanical means (Hydraulic excavator) means over areas in all kind of soil (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and as directed. |
| 5 | Material and labour plain cement concrete 1:4:8 type D-2 using 40 mm graded aggregate in foundations, filling and mass concrete complete all as specified and as directed. |
| 6 | Material and labour Reinforced cement concrete (design mix) M-25 using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 7 | Material and labour Reinforced cement concrete (design mix) M-25 using 20 mm graded stone aggregates as in walls, retaining walls, basement walls, ballast wallsany thickness, above top of footings including attached pilasters and buttresses complete all as specified and as directed. |
| 8 | Material and labour for steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for Roughfinished surfaces of concrete flat complete all as specified and as directed.. |
| 9 | Material and labour for steel formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, for fair finished surfaces of concrete flat complete all as specified and as directed. |
| 10 | Supply and fix TMT bars Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 11 | Supply and fix TMT bars Mild steel bars 6mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.. |
| 12 | Supply and fix PVC (SWR) pipes single socketed 75 mm bore in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 13 | Supply and fix Hand packing broken stone aggregate (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and as directed. |
| 14 | Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed. |
| 15 | Spreading and levelling with approved soil obtained from excavation in layers not exceeding25 cm thick, well ramming including watering as required complete all as specified and as directed. |
| 16 | Rough excavation not exceeding 1.5 m deep and getting out in any type of soil complete all as specified and as directed. |
| 17 | Material and labour for moorum/ red bajri filling in floors or pavings or for filling, laid in layers not exceeding. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 18 | Removing excavated material exceeding 250 m but not exceeding 500 m and depositing where directed complete all as specified and as directed. |
| 19 | Material and labour for preparing new surfaces of walls and applying two coats of cement wash with Portland cement slurryto a smooth bodied opaque finish complete all as specified and as directed. |
| 20 | Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ for 250mm thick wall all as specified and as directed |
| 21 | DEMOLITION |
| 22 | Demolition of Reinforced Cement Concrete roofs, floors (other than ground floor), beams, staircases, landing, chajjas and similar suspended work etc complete all as specified and as directed. |
| 23 | Demolition of Reinforced cement Concrete Column etc of any description and in any position not otherwise specifically provided for complete all as specified and asdirected. |
| 24 | Removing building materials etc to a distance of 1 km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination (Per load 3 Cubic Metre) complete all as specified and directed. |
| 25 | Taking up or down oldraising main DI pipe of size 100 mm dia from the RCC overhead reservoir of capacity 0.30 lakhgallonsof15 meter height to the existing valve chamber and keeping aside for taking credit to contractor complete all as specified and directed. |
| 26 | Taking up or down oldraising main DI pipe of size 150 mm dia from the RCC overhead reservoir of capacity 0.30 lakhgallonsof15 meter height to the existing valve chamber and keeping aside for taking credit to contractor complete all as specified and directed. |
| 27 | Taking up or down oldraising main CI pipe of size 150 mm dia from the New tank of DSSC filter House to GE reservoir and keeping aside for taking credit to contractor complete all as specified and directed. |
| 28 | Taking up or down oldraising main GI pipe of size 80 mm dia from the RCC overhead reservoir of capacity 0.30 lakhgallonsof15 meter heightto the existing valve chamber and keeping aside for taking credit to contractor complete all as specified and directed. |
| 29 | Taking up or down olddeliveryCI flanged endpipe of size 200 mm dia from the RCC overhead reservoir of capacity 0.30 lakhgallonsof15 meter heightto ground leveland keeping aside for taking credit to contractor complete all as specified and directed. |
| 30 | Taking down aluminium strips of old unserviceable lightening protection system with along with saddles and test point terminal blocks from top of above overhead reservoir and keeping aside for taking credit to he contractor complete all as specified and directed. |
| 31 | Taking down old unserviceable earthing chamber along with earthing materials such as earth plate, pipe, earth strip etc for taking credit to contractor all as specified and directed. |
| 32 | Taking down old unserviceable valve chamber along with sluice valve of size 80mm to 150mm dia below the overhead reservoir and keeping aside valves to credit to the contractor all as specified and directed. |
| 33 | Taking down old unserviceable conventional type water level indicator from the overhead reservoir and keeping aside for credit to the contractor all as specified and directed.Note: All arrangements for reaching the top of reservoir for removing the above said items (Item No.23 to item No.31) shall deemed to be included in the unit quoted rates. |
| 34 | ROAD/PATH |
| 35 | Surface excavation not exceeding 30 cm deep and averaging 20cm deep and getting out in any type of soil complete all as specified and directed. |
| 36 | Surface excavation not exceeding 30 cm deep and averaging 30cm deep and getting out in any type of soil complete all as specified and asdirected. |
| 37 | Material and labour for hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 38 | Material and labour plain cement concrete 1:4:8, type D-2,using 40mm graded aggregate as in 75 mm thick sub base, finished even and fair etc complete all as specified and as directed. |
| 39 | Material and labour for plain cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in 100 mm thick floors/ pavings, finished even and fair etc complete all as specified and as directed. |
| 40 | Material and labour Chequered cement concrete tiles with grey cement and pigments of min size20cm x 20 cm x 25 mm thick, set jointed and pointed in neat cement slurry in floorsover 20 mmthick screed bed in cement mortar1: 4 etc complete all as specified and as directed |
| 41 | EXTERNAL WATER SUPPLY |
| 42 | Supply and lay ductile iron pipe of size 100 mm diameter, spigot socket type, class-K9 confirmingto IS- 83269:2000 with cement mortar lining with portable slag cement as per relevant IS code, with metallic zinc coating with finishing layer of bituminous coating as per relevant IS including all accessories, tyton joints of EPDM gasket and fitting specials complete all as specified and directed. |
| 43 | Supply and lay ductile iron pipe of size 150 mm diameter, spigot socket type, class-K9 confirming to IS- 83269:2000 with cement mortar lining with portable slag cement as per relevant IS code, with metallic zinc coating with finishing layer of bituminous coating as per relevant IS including all accessories, tyton joints of EPDM gasket and fitting specials complete all as specified and directed. |
| 44 | Supply and laying 80mm bore steel water tubing medium grade galvanized with all fittings and laid in trenches/ fixed on walls/ floors including fittings etc complete all as specified and as directed. |
| 45 | Supply and laying 63mm (21/2\") bore steel water tubing medium grade galvanized with all fittings and laid in trenches/ fixed on walls/ floors including fittings etc complete all as specified and as directed. |
| 46 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles etc complete as specifiedandas directed. |
| 47 | Removal of excavated surplus soil not exceeding 50 m and depositing where directed atlevel not exceeding 1.5 m above the starting pointcompleteall as specifiedandas directed. |
| 48 | Supply and fixSluice valve both ends flanged of Class PN 1.6 of size 100 mm dia with all required necessary accessories etc complete all as specified and directed. |
| 49 | Supply and fix Sluice valve both ends flanged of Class PN 1.6 of size 80 mm dia with all required necessary accessories etc complete all as specified and directed. |
| 50 | Supply and fixSluice valve both ends flanged of Class PN 1.6 of size 150 mm dia with all required necessary accessories etc complete all as specified and directed. |
| 51 | Supply and fix Foot Valve confirmingto IS4038, 65 mm (2.5”) dia with all required necessary accessories etc complete all as specified and directed. |
| 52 | Supply and fix 50mm (2”) dia valve, Gun-metal, globe valve with iron wheel head, screwed both ends for iron pipe and fixed confirmingto IS9338,etc complete all as specified and directed. |
| 53 | Supply and fix 80mm dia non return valve with bypass arrangementswith all required necessary accessories etc complete all as specified and directed. |
| 54 | Supply and install centrifugal Monoblock pump set suitable for 415 V, 3 phase system having capacity 7.5 HP etc complete all as specified and directed.. |
| 55 | Supply and fix Fully Automatic Star Delta Starter 7.5 HP to 15 HP type ML 1.5 current rating 10 to 25 Amps in Sheet-Steel Enclosurewith Single Phase Protection feature (Motor Rating AC-3 Duty, 415 V, 50HZ, 3 Ph) completeall as specified and directed. |
| 56 | Material and labour for sub main wiring completewith and includingtwo runs of 6 Sqmm,single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including non metallic PVC conduit of suitable size including accessories etc as required and concealed in walls/ floors and 6 Sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly including taking down the existing sub main wiring complete all as specified and as directed.Note : (i) Two runs of 6 Sqmm PVC insulated cable and one run of 6 Sqmm cable and one run of PVC conduit shall be measured as one unit length.(ii) The cost of cutting chases and the cost of making good the disturbed surfaces is deemed to be included in the quoted rate. |
| 57 | Material and labour for Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 m below ground level and connected to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI wire protection (upto 7.5m long) & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.Note: On completion of the work/job the Contractor is to perform earth resistance tests for each earthing job in the presence of the Engineer-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Department till the results are satisfactory. |
| 58 | Supply and fixwater level monitoring instrument based on magnetic level sensing, sensor should sealed inside stainless steel and actuated by float and LED display Gives Level Indication (5 stages of 20% EACH) Automatic Control of Pump and Warning Alarms if level goes outside the automation range, including of necessary electrical wiring from float to LED display complete all as specified and directed. |
| 59 | Material and labour for construction of 230 mm thick wall brick masonry valve chamber of size 600 mm x 600 mm x 860mm height (internal size) for valves of size 50mm, including necessary earth work and excavation in any type of soil, 150 mm thick PCC foundation in 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in walls with sub class B bricks built in CM 1:6, PCC Coping 75mm thick and bed blocks for embedding the angle iron hold fasts with PCC 1:2:4 type B-1 using 20 mm stone aggregates, rendering in CM 1:4, 15 mm thick finished fair and even without using extra cement, including provision of MS Sheet cover 2mm thick fixed to MS angle iron frame made out of 40mm x 40 mm 4 mm thick, two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangements with lock and key including tarring to the embedded steel surfaces complete all as specified and as directed. |
| 60 | Material and labour for construction of 230 mm thick wall brick masonry valve chamber of size 900 mm x 900 mm x 860mm height (internal size) for valves of size 80/100mm, including necessary earth work and excavation in any type of soil, 150 mm thick PCC foundation in 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in walls with sub class B bricks built in CM 1:6, PCC Coping 75mm thick and bed blocks for embedding the angle iron hold fasts with PCC 1:2:4 type B-1 using 20 mm stone aggregates, rendering in CM 1:4, 15 mm thick finished fair and even without using extra cement, including provision of MS Sheet cover 2mm thick fixed to MS angle iron frame made out of 40mm x 40 mm 4 mm thick, two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangements with lock and key including tarring to the embedded steel surfaces complete all as specified and as directed. |
| 61 | Material and labour for construction of 230 mm thick wall brick masonry valve chamber of size 1200 mm x 1200 mm x 860mm height (internal size) for valves of size more than 100mm, including necessary earth work and excavation in any type of soil, 150 mm thick PCC foundation in 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in walls with sub class B bricks built in CM 1:6, PCC Coping 75mm thick and bed blocks for embedding the angle iron hold fasts with PCC 1:2:4 type B-1 using 20 mm stone aggregates, rendering in CM 1:4, 15 mm thick finished fair and even without using extra cement, including provision of MS Sheet cover 2mm thick fixed to MS angle iron frame made out of 40mm x 40 mm 4 mm thick, two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangements with lock and key including tarring to the embedded steel surfaces complete all as specified and as directed. |
| 62 | EXTERNAL ELECTRIC SUPPLY |
| 63 | Supply, lay and test of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric power cables, 1100 volt grade,with stranded aluminium conductor of size 95Sqmm x 3.5core, laid in trenches/ through GI Pipe/ fixed along with pole structure etc complete all as specified and as directed.Note : Necessary earthwork, cable protection items shall be measured & paid separately under relevant items. |
| 64 | Supply and spreading clean dry riddled sand in trenches for cushioning all as specified for cable protection in trenches / ducts complete all as directed. Note: The punned down thickness shall only be measured and paid. |
| 65 | Supply and laying un-reinforced precast concrete cable cover, class LV, type1, flat, size 250 x 150 x 40mm in trenches for protection of UG Cable with width equal to length of PCC cover, laid dry & flat complete all as specified and as directed. |
| 66 | Supply install test and commission indoor LT Panel board, TPN 415 Volts, 50 Hz,indoor cubical type floor mountedfactory made double doordust and vermin proof, IP-54, fabricatedout of CRCA sheet not less than 2 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50X50X6mm with cable chamber for incoming and outgoing connections comprising for the following including necessary PCC foundation of minimum 0.35m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal and connecting all incoming and out going cables all as specified and directed :-(a) INCOMING:-MCCB 4 Pole , 16 kA, 63 Amps 415 Volts - 1 No(b) OUTGOING:- (i) MCCB 4 Pole , 16 kA, 40 Amps 415 Volts - 2 Nos (ii) MCB 4 pole , 16kA, 40 Amps 415 Volts - 1 Nos(c) 200 Amps aluminium busbar for phase and 200 Amps for neutralduly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set(d)Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection- 1 Nos(e)LED typeIndication lamp240 Volts Set of three - 1 Set |
| 67 | Material and labour Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 m below ground level and connected to GI earth strip 25x4 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 5 of SSR Part -I and testing on completion including taking down existing earthing etc complete all as specified and as directed.Note: On completion of the work/job the Contractor is to perform earth resistance tests for each earthing job in the presence of the Engineer-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Department till the results are satisfactory. |
| 68 | DG SET |
| 69 | Supplying, Installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set as per CPCB IV norms, fully wired alternator to give an out put of 40 kVA continuously raing at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz + 1% supply, directly coupled with diesel engine, liquid cooled ofsuitable BHP de-rated for Wellington, Nilgiris at high altitude of approximate 2000 Mtr mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line and accessories, PCC foundation work as per manufacture\"s instructions, vibration damper pads, AMF control panel, Battery& other accessories etc and comprising of following :-Make : Kirloskar / Cummins / Greaves Cotton or equivalent makes in list of manufactures(a) Diesel Engine liquid cooled, turbocharged with after cooled to deliver required BHP a under NTP condition ofBS 5514 standard de-rated for Wellington, Nilgiris at high altitude of approximate 2000 Mtr and confirming to IS 10001/10002 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories. |
| 70 | Make :Kirloskar / Cummins/Greaves Cotton(i)Dry type air cleaner(ii) Exhaust Silence suitable for canopy(iii)Expansion bellow(iv) Lube oil Cooler(v)Fuel Filters(vi) Radiator with pusher type fan and mounting(vii)In-line mono block fuel injection pump(viii)Mechanical governor and fuel feed pump(ix) Fly wheel with starter ring and bell bousing suitable for close coupling(x) 12 Volt electric starter motor(xi) Battery charging alternator(xii) Microprocessor based Kilogram934(L1) Controller mounted are fixed in power panel(xiii) Protection system for Low lube oil pressure and High water temperature(xiv) Battery:- Suitable Maintenance free battery with leads & terminals as per OEM recommendation (Make- Exide/Amron) .(xv) Fuel tank:08 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator, fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling from exterior canopy (without opening its panel) etc complete all as specified and directed. |
| 71 | (b) Alternator suitable rated at 40 kVA at 0.8 power factor , 415 volts, 3 phase, 4 wire, 50 Hz atself excited and self regulated with AVR brushless excitation, screen protected, drip proof , insulation class H,self ventilated, floor mounted with ball or bearing on end shields and conforming to IS: 4722 suitable for engine as mentioned here-in before. Make:Kirloskar / STAMFORD/ Crompton.(c) Acoustic Enclosure:- Acoustic enclosure with outer body made of 2mm thick CRCA sheet , epoxy coated and sound insulation to reduce noise level to 75 dBA measured at 1.0 meter average distance for audible frequencies as per guide of Central Pollution Control Board or latest CPCB norms and of suitable size and OEM specification and inside illumination with 1 No. 1 x 18 watt LED fitting .MakePhillips/ Bajaj/ Crompton or equivalent make in list of manufactures(d)Standard Gen set Controller with Control Panel -Gen Set controller unit totally enclosed, steel construction control panel suitable for indoor floor/ wall mounting installation with control fuse base with necessary link, power terminals and control terminal start and stop relayhaving following safeties and display parameters :- |
| 72 | (i) Engine display Parameter for :-(aa) Oil Pressure(ab) Engine Coolant Temperature(ac) Fuel Status(ad) Engine Speed(ae)Battery Voltage(af) Engine Hours (ii) Mechanical Safeties (along with Display) for :-(aa)Under / Over Speed(ab)Low lube oil Pressure(ac)High Engine coolant Temperature (iii) Gen-Set Display parameter for :-(aa)Phase Voltage(ab)Line Current(ac)Frequency & PF(ad)Average Voltage(ae)Average Current(af) Phase KW and Total KW(ag)KWH(ah)KVA & KVAR (iv) Electrical Safety (alongwith display ) parameter for :-(aa) Genset under / over voltage(ab) Under / Over Frequency(ac) Phase Failure(ad) Phase sequence reverse(ae) Over Current(af)Over KW |
| 73 | (e) Civil works:- All civil works related to foundation (Foundation for DG set using cement concrete type B0 1:2:4(12.5mm) graded aggregate as directed by Engr-in-charge), installation of panel and equipment & depth of foundation shall be minimum 300mm with anti vibration pads, or as recommended by manufacturers shall deemed to have been included in the quoted rate. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. |
| 74 | Material and labour for earthing complete with galvanized steel plate earth electrode 60 cm x 60 cm x 6 mm thicksurrounded by char coal and saltburied directly in ground vertically in pit of depth not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 m below the normal ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected togalvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanised iron steel and connected to earthing test point including all earth work , earth lead protection light grade GI pipe of 15 mm dia, light grade GI pipe of 20 mm dia for watering with funnel , wire mess, PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical plate No 3 of SSR Part-I including testing complete all as specified and directed. Note : (i) If earthing resistance not obtained less than 2 ohm then re-earthing or any other work shall be done by contractor without any additional cost complete all as specified and directed. |
| 75 | INTERNAL ELECTRIC SUPPLY |
| 76 | Material and labour for Point wiring for One light /Exhaust fan point/Bell point, controlled by one switch 5 Amp SP one-way complete with 1.5 Sqmm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn through and including non metallic rigid PVC conduit (medium quality) and conduit accessories concealed in wall/ floor/ ceiling, provision of factory made branded galvanised steel pressed terminal box(Modular metal flush box with cover plate) 3mm thick of suitable module with white cover plate of same module with frame for housing the modular switches, sockets, fan regulators etcincluding 1.5 Sqmm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire connecting to common earth dolly etc complete all as specified and directed. |
| 77 | One light / exhaust fan point controlled by one 5 Amps, one way switch complete all as specified and as directed. |
| 78 | One 6A, 2/3 pin switch socket out let multipurpose on same board complete all as specified and as directed. |
| 79 | All as per item No 65.00hereinbefore but with 2.5 Sqmm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 16 Amp on independent board including 2.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire to common earth dolly completed all as specified and directed. |
| 80 | Supply and fix Ceiling rose, surface backlite, 65mm x 50mm three terminals, PVC / polycarbonate isolated body complete all as specified and as directed. |
| 81 | Supply and fix Modular switch, one way, 6Amps, 230V, AC, 50Hz, SP, one module completeall as specified and as directed. |
| 82 | Supply and fix Modular switch, one way, 16Amps, 230V, AC, 50Hz, SP, one module completeall as specified and as directed |
| 83 | Supply and fix Modular socket 6 Amps, 230V AC 50 HZ, 2/3 pin type 2 module complete all as specified and directed. |
| 84 | Supply and fix Modular socket 2/3 pin combined, 6/ 16 Amps, 230V AC 50 HZ, 2 module completeall as specified and as directed. |
| 85 | Material and labour for submain wiring completewith and including2 runs of 6 sqmm,single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including non metallic PVC conduit of suitable size including accessories etc as required and fixed on walls and 6 sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dollycomplete all as specified and as directed by Engineer-in-Charge.Note :Two runs of 6 sqmm PVC insulated cable and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one unit length. |
| 86 | Supply and fix sheet metal enclosure for DBs, double door type, when MCBs to be used SPN 4 ways including blanking plate as required with 200 Amps rated busbar, 240 volts fixed sunk/ flush to the wall or niche etc complete all as specified and directed. |
| 87 | Supply and fix MCB, Single Pole, 240Volts, AC,\"B\" curve, 10KA, 6 to 32 Amps,current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 88 | Supply and fix MCB, SPN 32 Amps,240V, 10 KA \"B\" curve, current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 89 | Supply and fix wall mounted 1 x 20watt LED 6000K, 4 feet LED tube light batten, minimum lumen output 100 lum/ watts extruded alumionium heat sink provided for efficient heat dissipation & integrated electric driver, lamp colour white including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose etc complete all as specified and directed. |
| 90 | Supply and fix LED street light/ security light luminaries fitting 1 x 35 Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple opticswith IP 65/66 protection including makingconnection with PVC insulated 3 single core of 1.5sqmm size multistranded copper conductor cable includingbracket made out of GI pipe light grade 32mm dia 1.20m long, bent to shape with suitable size mild steel flat iron clamps of size 50 x 6mm with nut, bolt & washers as required at site for fixing of street light on LT pole/ wall etc complete all as specified and directed. |