| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | Supplying and Filling in Plinth with Sand Under Floors including watering ramming consolidating and dressing complete |
| 4 | Providing and Laying cement Concrete 1:4:8(1cement:4 coarse sand(Zone-III):8graded stone aggregate 40 mm nominal size derived from natural resources) |
| 5 | Providing and Laying cement concrete in Retaining Walls Return Walls inlcuding attached pilasters,columns, piers, abutments, pillars posts struts, buttress,strings or laces courses, parapet,coping,bedblocks,anchorblocks,plain window sills fillets,sunken floor etc upto floor level five, excluding the cost of centreing shuttering and finishing 1:3:6(1cement:3 coarse sand(Zone-III): 6graded stone aggregate 20 mm nominal size derived from natural resources) |
| 6 | Providing and Laying cement concrete in Retaining Walls Return Walls inlcuding attached pilasters,columns, piers, abutments, pillars posts struts, buttress,strings or laces courses, parapet,coping,bedblocks,anchorblocks,plain window sills fillets,sunken floor etc upto floor level five, excluding the cost of centreing shuttering and finishing1:1.5:3(1cement:1.5coarse sand(Zone-III): 3graded stone aggregate 20 mm nominal size derived from natural resources) |
| 7 | Centering and Shuttering including strutting propping etc for wall including attached pilaster, columns , pillars |
| 8 | Centering and Shuttering including strutting propping etc and removal of formwork for Foundation, Footings and Bases of columns |
| 9 | Making Plinth Protection 50 mm thick of cement concrete1:3:6 over 75 mm thick bed of Dry Brick Ballast 40 mm nominal size well rammed and consolidated and grouted with Fine Sand including necessary excavation, levelling, & dressing and finishing the top smooth |
| 10 | Providing & doing Brick work with common burnt clay bricks FPSnon modularin below foundation of class designate 75 in foundation and plinth in CM1:4 |
| 11 | Providing & doing Brick work with common burnt clay bricks FPSnon modularin below foundation of class designate 75 above plinth in CM1:6 |
| 12 | Half Brick Mansonary with common burnt clay bricks non modular with class deignate 7.5 in super structure above plinth level upto level V in CM1:4 |
| 13 | Providing and Fixing 18 mm thick gang saw cut mirror plshed,premoulded and prepolished,machine cut for Kitchen Platforms,vanity counters,window sills,facias and similar locations of required size approved colour or texture laid over 20 mm thick base cement mortar 1:4(1 cement:4 coarse sand) joints treated with white cement,mixed with matching pigment,epoxy toch ups including rubbing curing,moulding of edges, polishing to give high gloss finish etcGranite stone slab of all colours except black, cherry or ruby red area of slab over 0.50 sqm |
| 14 | Providing edge moulding to 18 mm thick marble stone counters including machine polishing to give high gloss finish etc |
| 15 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 16 | Providing wood work in doors of windows, celestry windows, door frames, wroughed framed and fixing in position,with hold fast lugs and dash fastners, of required dia and length (Hold fast lugs or dash fastners to be paid seperatel) |
| 17 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters: |
| 18 | Extra for providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters confirming to IS2202 part 1 |
| 19 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 20 | Extra for cutting rebate in flush door shutters |
| 21 | Providing & Fixing IS 12817 Stainless steel butt hinges heavy weight with stainless screws complete 125X64X2.50 mm |
| 22 | Providing and Fixing ISI Marked Stainless steel handles 250 mm long 10 mm thick of good quality with necessary screwsas approved by Engineer In Charge |
| 23 | Providing and Fixing ISI Marked Stainless steeltower bolts 250X10 mm Barrel type with necessary screwsof good quality as approved by Engineer In Charge |
| 24 | Providing and Fixing ISI Marked Stainless steel door latch/aldrop 250X10 mm Barrel type with necessary screwsof good quality as approved by Engineer In Charge |
| 25 | Providing & Fixing hanging type door stopper stainless steel including screws |
| 26 | Providing and fixing aluminium extruded section body tubular typeuniversal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete |
| 27 | Providing & Fixing Ismarked Aluminum Butt Hingesanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc100X63X3.2 mm |
| 28 | Providing & Fixing Is marked Aluminum Tower bolts barrel typeanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc250X10 mm |
| 29 | Providing & Fixing Is marked Aluminum Handles typeanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm |
| 30 | Providing & Fixing Is marked Aluminum Door Stopper typeanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm Twin Rubber Stopper |
| 31 | Providing & Fixing of Aluminum Pull Bolt lockanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm Twin Rubber Stopper |
| 32 | Providing and Fixing brass finished 100 mortise lock and latch with six leversISI marked with screws etc |
| 33 | Providing & Fixing of Aluminum casement stays anoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm Twin Rubber Stopper |
| 34 | Providing and Fixing Fly Proof Stainless steel grade 304 to windows and celestry windows using wire guage with average width of aperture 1.4 mm in both directions with wire of dia0.50 mm all complete with 12mm mild steel u beading |
| 35 | Structural steel work fixed with or without connecting plate including cutting hoisting fixing in position,and applying a priming coat of approved steel primer all complete |
| 36 | Providing & Fixing MSSheet Door Frame of 40X40X6 mm agnle iron3 mm gusset plates at the Junctions,and corners 25 mm dia pulley including all necessary fittings and primer coat of approved steel primer using MS agnles40X40X6 for diagonal braces |
| 37 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 38 | Marble Stone Flooring with 18 mm thick as per sample of marble approved over20 mm thick base of cement mortar 1:4 laid and jointed with grey cement slurry including rubbing and polishing complete Udaipur Green Marble |
| 39 | Extra for prefinishednosing to treads of steps of marble stone |
| 40 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 41 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 42 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (a) Size of Tile 600x600 mm |
| 43 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % andonforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 44 | Grouting the joints of Flooring having joints of 3mm width using epoxy grout of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardnerand 0.20kg of resin per kg including filling grouting and finishing complete as per directions of Engineer In Charge size of tile 600mmX600mm |
| 45 | Providing and laying flamed finish Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent. |
| 46 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) |
| 47 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand) |
| 48 | 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) |
| 49 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 50 | Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 51 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 52 | Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 53 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 54 | Providing and fixing Sand Cast Iron grating for Gully trap 100 mm |
| 55 | Providing and Fixing SS grating 100 mm (lockable)(100 mm/75mm) dia for floor trap |
| 56 | Providing and Fixing Float glass panes 4mm thick. |
| 57 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion |
| 58 | For Openable Portion shutters of doors windows and ventilatorsFor shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the cost ofEPDM rubber / neoprene gasket required (Fittings shall bepaid for separately) |
| 59 | Providing and fixing 12 mm thick pre laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. |
| 60 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm width and 5 mm depth |
| 61 | Providing & Fixing aluminium casement window fastner of required length for aluminium windows with necessary screws etc Anodised (AC15) Aluminium |
| 62 | Steel Reinforcement in RCC Works including straightening, cutting, bending and Fixing in Position, and Binding all complete upto plinth level TMT bars of FE500 or more grade |
| 63 | Steel Reinforcement in RCC Works including straightening, cutting, bending and Fixing in Position, and Binding all complete above plinth level TMT bars of FE500 or more grade |
| 64 | Providing and Fixing double action hydraulic floor spring of approved brand and Manufacture confirming to IS 6315, having brand logo embossed, on the body plate with double spring mechanism, and door weight upto 25 kgs,for doors, including cost of cutting floors, embedded n floors as required, and making good the same , matching to existing floor finishing and cover plates,with brass pivot and single pieces, MS sheet outer box plate and complete as per the directions of Engineer-In-Charge with SS cover plate of minimum 1.25 mm thickness |
| 65 | Providing and Fixing 12 mm thick frameless, toughened Glass door shutter, of approved brand and manufacture, including providing and fixing top and bottom pivot, and double acting hydraulic floor spring type fixing arrangement, and making necessary holes etc for fixing required door fittings,all complete as per the directions of Engineer-In-Charge(Dor, Handle and lock to be paid seperately) |
| 66 | Providing and fixing 60 mm thick factory made cement concrete paver block of approved shape and size of M-35 grade in footpath ,parks, lawns, driveways, made by table vibrratry method using PU Mould, into sand bedding layerfilling the joints with sand and cutting of paver blocks, as per required size, shape and pattern,finishing and sweeping extra sand |
| 67 | Designing ,suplying, fabricating and fixingincludingtesting extruded tubular and other aluminium sections as per architectural draings and approved shop drawings , the aluminiu quantity as per grade 6063T5 or T6 as per BS1474 including superdurable power coating of 60-80microns confirming to AAMA2604,of required colour and shade as approved by Engineer-In-Charge. The item include cost of material such as cleats,sleeves, screws etc,necessary for fabrication of extruded aluminium framework(Nothing extra shall be paid on this account) The weight of Aluminium extruded section shall be taken for purpose of payment payment |
| 68 | Providing and fixing Toughened Glass of 6 mm thick reflective with structural glazing tape 2mmX12mm VHB along with filling o of Joints with weather silicon to make structure leak proof |