Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Lift from 1.50 m to 3.00 m |
| 2 | Earth work excavation for mass cutting in all kinds of soil including hard laterite, strutting, shoring and packing cavities wherever required, bailing/pumping out water from any depth, if required and getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth, consolidating each layer by watering, ramming, etc., and disposing of surplus excavated earth of at all leads at the risk of the contractor etc. complete. |
| 3 | Lift upto 1.50 m |
| 4 | Lift from 1.50 m to 3.00 m |
| 5 | Providing and filling in plinth or in areas with selected earth brought from outside the site including transportation, loading, unloading, taxes, etc, screening, watering, ramming, and consolidating in layers of 15 cms etc complete as directed by Engineer-in-Charge. |
| 6 | Filling over areas, inside plinth etc. with earth available at site including compaction in layers of uniform thickness not exceeding 200 mm compacted thickness, watering the earth to bring the earth upto required OMC and rolling to specification with the use of suitable roller when earth is at suitable moisture content to achieve dry field density not less than 95% maximum dry density (Modified proctor density), including loading, unloading transportation to all leads etc complete as directed by Engineer-in-Charge. |
| 7 | Supplying, diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier, using Chlorpyriphos or any equivalent Emulsifiable concentrate 20% with 1% concentration, as per IS:6313 (part II) under and all around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor, along the external perimetre of building, expansion joints, surroundings of pipes and conduits etc. complete as per specifications (Plinth area of the building at ground floor only shall be measured for payment). |
| 8 | CONCRETE AND ALLIED WORKS |
| 9 | Providing and laying PCC 1:4:8 (1 cement, 4 coarsesand and 8 graded stone aggregate 40mm nominalsize) machine mixed and properly consolidated withhand rammers, for foundation and flooring including cost and conveyance ofall materials, labour, shuttering, curing, lead lift, etc.complete at all levels and as directed by Engineer-in-charge. |
| 10 | Providing and laying PCC 1:3:6 (1 cement, 3 coarsesand and 6 graded stone aggregate 40mm nominalsize) machine mixed and properly consolidated withhand rammers, for foundation and flooring including cost and conveyance ofall materials, labour, shuttering, curing, lead lift, etc.complete at all levels and as directed by Engineer-in-charge. |
| 11 | Providing and laying RCC of design mix M25 to proper gradients, lines and levels, machine mixed, mechanically vibrated including cost of centering and shuttering, curing, etc. complete including cost, conveyance, lead, lift of all materials, labour, etc. but excluding cost and labour for steel reinforcement for foundations, footings, pile caps, rafts,grade beams, base slab, etc. below plinth level as directed by Engineer-in- charge. (Minimum cement content 360 kg/ cum) |
| 12 | Providing and laying RCC of design mix M30 to proper gradients, lines and levels, machine mixed, mechanically vibrated including cost of centering and shuttering, curing, etc. complete including cost, conveyance, lead, lift of all materials, labour, etc. but excluding cost and labour for steel reinforcement for columns, Pillars, etc. as directed by Engineer-in- charge. (Minimum cement content 360 kg/ cum) |
| 13 | Upto Highest Plinth level |
| 14 | Ground Floor upto 3.50 m |
| 15 | Ground Floor from 3.50 m to 7.00 m |
| 16 | Ground Floor from 7.00 m to 10.50 m |
| 17 | Providing and laying RCC of design mix M25 to proper gradients, lines and levels, machine mixed, mechanically vibrated including cost of centering and shuttering, curing, etc. complete including cost, conveyance, lead, lift of all materials, labour, etc. but excluding cost and labour for steel reinforcement for beams, lintels etc. as directed by Engineer-in-charge. (Minimum cement content 330 kg/cum) |
| 18 | Ground Floor upto 3.50 m |
| 19 | Ground Floor from 3.50 m to 7.00 m |
| 20 | Ground Floor from 7.00 m to 10.50 m |
| 21 | Providing and laying RCC of design mix M25 to proper gradients, lines and levels, machine mixed, mechanically vibrated including cost of centering and shuttering, curing, etc. complete including cost, conveyance, lead, lift of all materials, labour, etc. but excluding cost and labour for steel reinforcement for roof slabs, sunshades etc. as directed by Engineer-in-charge. (Minimum cement content 330 kg/cum) |
| 22 | Upto Highest Plinth level |
| 23 | Ground Floor upto 3.50 m |
| 24 | Ground Floor from 3.50 m to 7.00 m |
| 25 | Providing and laying RCC of design mix M25 to proper gradients, lines and levels, machine mixed, mechanically vibrated including cost of centering and shuttering, curing, etc. complete including cost, conveyance, lead, lift of all materials, labour, etc. but excluding cost and labour for steel reinforcement for walls up to 25cms thick as directed by Engineer-in-charge. (Minimum cement content 360 kg/cum) |
| 26 | Upto Highest Plinth level |
| 27 | Ground Floor upto 3.50 m |
| 28 | Ground Floor from 3.50 m to 7.00 m |
| 29 | Providing and laying RCC of design mix M25 to proper gradients, lines and levels, machine mixed, mechanically vibrated including cost of centering and shuttering, curing, etc. complete including cost, conveyance, lead, lift of all materials, labour, etc. but excluding cost and labour for steel reinforcement for stairs as directed by Engineer-in-charge. (Minimum cement content 330 kg/cum) |
| 30 | Ground Floor upto 3.50 m |
| 31 | Providing and laying RCC of design mix M25 to proper gradients, lines and levels, machine mixed, mechanically vibrated including cost of centering and shuttering, curing, etc. complete including cost, conveyance, lead, lift of all materials, labour, etc. but excluding cost and labour for steel reinforcement for Flooring as directed by Engineer-in-charge. (Minimum cement content 330 kg/cum) |
| 32 | Straightening, decoiling, cutting bending, fixing in place, binding with 18 gauge GI binding wire, placing in position Grade Fe 500 TMT steel reinforcement including cost, conveyance, lead, lift of all materials for all types of RCC works as per drawings / specifications and as directed by Engineer-in-charge. (Overlaps of steel as per drawing and with authorised overlaps only shall be measured and paid for.) |
| 33 | MASONRY WORK |
| 34 | Providing and constructing cement concrete solid block masonry 15 cm / 20 cm thick in C.M 1:6 (1 cement : 6 coarse sand) using solid block of size 30x20x15 cms and approved qualityincluding scaffolding, raking out of joints, curing, cost and conveyance of all materials, labour, lead,lift, etc complete as per the direction of Engineer-in-Charge for all types of masonry works. |
| 35 | Upto Highest Plinth level |
| 36 | Ground Floor upto 3.50 m |
| 37 | Ground Floor from 3.50 m to 7.00 m |
| 38 | Ground Floor from 7.00 m to 10.50 m |
| 39 | Providing and constructing 100mm thick cement concrete solid block masonry 10 cm thick in C.M 1:4 (1 cement : 4 coarse sand) in partition walls, parapets, etc. using solid block of size 30x20x10 cms and approved quality including scaffolding, raking out of joints, curing, cost and conveyance ofall materials, lead, lift, etc. complete including providing 2 Nos. 6mm dia bars, as reinforcement at everythird layer wherever specified (Reinforcement shall bemeasured and paid for under relevant item) and as directed by Engineer-in-charge at all levels. |
| 40 | Ground Floor upto 3.50 m |
| 41 | WOOD WORK & ALUMINIUM WORKS |
| 42 | Providing and fixing fullypanelled powder coated Aluminum door of Indal sections (Section nos.9809, 5140, 9241, 9239, 9240, 9200, 9201, 4682 etc.) with 12mm thick exterior grade both side laminated particle board of approved brand fixed with aluminum glazing clips, neoprene beading as per drawings with lock systems, concealed tower bolts, pivots, floor mounted door closers, door handles etc including cost of all materials, conveyance, lead, lift etc. complete as per specifications and as directed by Engineer-in-charge. |
| 43 | Providing and fixing fully glazed powder coated Aluminium sliding windows (20 mm series of Hindalco or equivalent with shutter width of 60 cms approx.) of approved colour using approved 20 mm series sections (Outer frames with thickness 1.50 / 1.60 mm and shutter frames with thickness 1.50 mm) and plain float glass of thickness not less than 5mm including all fittings such as handles, rollers, stoppers, locking arrangement, cost and conveyance of all materials, labour charges, sundries etc complete as per the directions of Engineer-in-charge. |
| 44 | Providing and fixing powder coated Aluminium louvered ventilators (sections of Hindalco or equivalent with panel width of 50 cms approx.) of approved colour using approved Indal sections (Section no.9809) and pin headed glass of thickness not less than 4mm including cost and conveyance of all materials, labour charges, sundries etc complete as per the directions of Engineer-in-charge. |
| 45 | STEEL WORKS |
| 46 | Steel work in built-up sections, trusses, purlins, framed work, etc with MS Hollow Sections, grade 310 MPa, as per the drawings including cost of all materials, labour charge and conveyance, straightening,cutting, fabricating, hoisting & fixing in position and painting two coats of anti corrosive yellow zinc chromate primer & two coats of synthetic enamel paint of approved makeetc. complete as directed by Engineer-in-charge. at all levels |
| 47 | Supplying and fixing M.S. round holdong down bolts with nuts and washer plates etc., complete. |
| 48 | Supplying and fixing MS fabricated grills to window / ventilator frames / wall openings using MS flats, MS Squares, MS rods etc. as per drawing including cutting, fabricating, welding, fixing, painting with one coat of zinc chromate primer and two coats of synthetic enamel paint of approved quality and colour, all cost of materials and labour charges, etc. complete as directed by engineer-in-charge at all levels. |
| 49 | Providing and fixing chicken wire mesh of 24 gauge including fixing with nails etc. at the junction of brick masonry and RCC or any other place including cost and conveyance of all materials, labour etc. complete as directed by engineer-in-charge at all levels. |
| 50 | Providing and fixing of SS hand rails (grade 304) made of square / rectangular hollow sections, plates etc for stairs / steps using 40 mm square top rail and verticals at start and ending points and 25 mm square verticals at 125 mm c/c spacing, including welding, grinding, buffing & polishing and making curvature (where ever required), and fitting the same with necessary SS nuts and bolts etc complete. |
| 51 | Supplying and fixing powder coated rolling shutters of approved make, made of 80 x 1.25mm M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No. 2, necessary bearings and 1.25mm thick M.S. top cover for rolling shutters. |
| 52 | Extra for providing mchanical device chain and crank operation for operating rolling shutters exceeding 10.00 sqm and upto 16.80 sqm in the area |
| 53 | ROOFING |
| 54 | Supplying & fixing of Galvalume Hi Rib Profiled Sheeting 970mm-1000mm covered width, 26-28mm crest height at 195-200mm centres made out of 0.5mm TCT cold rolled steel 550Mpa yield strength confirming to ASTM A 368 (OR) AS 1595 with hot dip metallic coating of minimum 150gm/sqm zinc aluminium alloy coating mass (55% aluminium, 43.5% zinc & 1.5% silicon) total of both sides as per ASTM A792 (OR) AS 1397.The colour shall have a total coating thickness of 35 micron of modified |
| 55 | polyester paint system of approved colour comprising 20 micron exterior coat on top surface and 5 microns reverse coat on back surface over 5 micron primer coat on both sides.The roofing sheet shall be crest fixed to purlins with hot dip galvanized self drilling fasteners with EPDM washers. Minimum sheet overlap at end laps shall be 150mm. Penetration and end laps in sheet shall be sealed by using proper sealant.Rate shall include cost and conveyance of all materials, lead, lift, scaffolding, labour charges etc. complete at all levels and as directed by Engineer In Charge. |
| 56 | Supplying & Fixing of 0.5mm thick galvalume Ridge/Flashing made out of 0.5mm TCT cold rolled steel 550Mpa yield strength confirming to ASTM A 368 (OR) AS 1595 with hot dip metallic coating of minimum 150gm/sqm zinc aluminium alloy coating mass (55% aluminium, 43.5% zinc & 1.5% silicon) total of both sides as per ASTM A792 (OR) AS 1397.The colour shall have a total coating thickness of 35 micron of modified polyester paint system of approved colour comprising 20 micron exterior coat on top surface and 5 microns reverse coat on back surface over 5 micron primer coat on both sides fabricated to required size as per the site requirement up to 600mm girth. All the joints shall be sealed with proper sealant and stitched with stitching screws. Rate shall include cost and conveyance of all materials, lead, lift, scaffolding, labour charges etc. complete at all levels and as directed by Engineer In Charge. |
| 57 | FLOORING |
| 58 | Charges for Vacuum Dewatering in concrete flooring with addition of floor hardener as per the following operations. (Cost of concreting including laying and levelling will be paid separately in the respective item). |
| 59 | a) Providing ISMC shuttering with 25 mm dia holes @ 300 c/cfor inserting MS rod. |
| 60 | b) Vibrating the base concrete with surface vibrator. |
| 61 | c)Removing excess water from the concrete using vacuum compresssed dewatering system. |
| 62 | d)Supplying, providing and spreading nito floor hardner toping standard @ Rs.3.5 Kg/cm2. |
| 63 | e)Finishing the top surface of the floor with power trowel to achieve smooth floor. |
| 64 | Cutting 5 mm x 10 mm deep grooves in the vacuum dewatered concrete floor and filling with polysulphide sealant of Fosroc make or approved equivalent, as per manufacturers specification, including cost and conveyance of all materials, labour charges, sundries etc. complete. |
| 65 | Providing and applying floor plastering over steps, staicases etc. with cement mortar 1:3 (1 cement and 3 fine sand) 15mm thick finished with a floating coat of neat cement with thread lines, including cleaning, applying cement slurry, cost and conveyance of all materials, labour, curing, etc as directed by Engineer-in-Charge at all levels. |
| 66 | Providing and laying Anti-skid ceramic tiles 300x300mmin toilet flooring, including an under layer of cement mortar 1:4 (1 cement : 4 coarse sand) 20mm thick and cement slurry @ 3.3kg of cement per sqm. finished with flush pointing using approved joint filler of matching shade including cost and conveyance of all materials labour etc. complete as directed by engineer-in-charge at all levels. |
| 67 | Providing and laying coloured glazed tiles of approved design and pattern of size 200x300 mm on walls flush with the wall plastering, dado etc., including an under layer of cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick and finished with flush pointing using approved joint filler of matching shade including cost and conveyance of all materials, labour, etc. complete as directed by Engineer-in-charge at all levels. |
| 68 | FINISHING |
| 69 | Providing and applying cement plaster 1:3 (1 cement and 3 fine sand) 9mm thick one coat floated hard andtrowelled smooth to get a smooth finish to ceiling including cost and conveyance of all materials, labour, curing, etc as directed by Engineer-in-Charge at all levels. |
| 70 | Providing and applying cement plaster 1:5 (1 cement and 5 fine sand) 12mm thick one coat floated hard andtrowelled smooth to get a smooth finish to all surfaces such as walls, columns, beams, etc. on inside and outside, including cost and conveyance of all materials, labour, curing, etc as directed by Engineer-in-charge at all levels. |
| 71 | Providing and applying cement plaster 1:3 (1cement and 3fine sand) 15mm thick in two coats including a flushing coat of cement @ 2.2 kg/SQM) including mixing of approved quality water proofing compound (as per manufactures specification or Engineers direction), over slabs, gutters, sunshades, and smooth surface, etc. including cost and conveyance of all materials, labour, curing, etc. as directed by the Engineer-in-charge at all levels. |
| 72 | Providing and applying antifungal exterior emulsion paint of approved quality and colour, two or more coats over a coat of exterior grade primer of approved brand, to all exterior surfaces such as walls, columns, ceiling, etc., after scraping and cleaning the surface and providing an even finish, including cost and conveyance of all materials, labour, hire charges for scaffolding, etc., as directed by Engineer-in-charge at all levels. |
| 73 | MISCELLANEOUS BUILDING WORK |
| 74 | Supplying and fixing FRP door frame and shutter, with frame of size of 100x63mm including the thickness of FRP and 30 mm thick door shutters with 100 mm outer frames and 80 inner styles, filling inside of FRP with seasoned treated rubber wood, including providing and fixing anchor bolts for fixing the frames, three numbers of 100 mm heavy duty MS powder coated hinges, two numbers 150 mm anodised aluminium tower bolts, one number 150x16 mm anodised aluminium aldrop, two numbers 100 mm anodised aluminium handles, finishing the joints to match the surroundings and finishing the frames and shutter by buffing and polishing with wax etc. complete as directed by Engineer-in-charge. |
| 75 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom and other concrete surface etc., by applying cement based two component polymer modified water proofing slurry coating, after cleaning the surface free from scale, rust, grease, oil, etc. preparing the surface to be true and flat and saturated, mixing the liquid (A) and powder (B) components in the ratio 1:4 by weight, applying in two coats with an interval of 2 to 6 hrs for hardening in between and finally finishing by rubbing down with a soft, dry sponge including protecting the applied surface from direct sunlight and strong wind and curing by damp gunny bags or polythene sheating upto 5 days etc. complete. The rate includes the preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. Note: Rendering /plastering as protective layer if required will be paid separately. The treatment shall carry 10 years guarantee for any kind of defects. |
| 76 | Supplying and filling in sunken slabs with 6 mm stone chips under floors including, watering, ramming, consolidating and dressing complete. |
| 77 | WATER SUPPLY WORKS |
| 78 | Supplying, laying, jointing and testing in position schedule 40 high pressure uPVC pipes pasting type conformingto ASTM-D-1785 (sizes in ID) cutto requiredlengthsincluding all necessary fittings and schedule 80 specials conforming to ASTM-D-2467, such as tees, bends, elbows, unions, etc. including fixing at wall/ceiling level supported by galvanized clamps, slotted rails, height adjustable hangers, etc. as per specification, cutting hole in wall / floor / slab and making good the same, testing the lines after connecting to mains, etc. complete for ceiling / wall suspended water supply lines. |
| 79 | 40 mm dia (1 1/2 inch) |
| 80 | 32 mm dia (1 1/4 inch) |
| 81 | 25 mm dia (1 inch) |
| 82 | 20 mm dia (3/4 inch) |
| 83 | Supplying, laying, jointing and testing in position schedule 40 high pressure uPVC pipes pasting type conformingto ASTM-D-1785 (sizes in ID) cutto requiredlengthsincluding all necessary fittings and schedule 80 specials conforming to ASTM-D-2467, such as bends, tees, unions,reducers,flanges& plugs, etc. for concealed water supply lines including making chasing in wall / floor and making good the same by using 1:1 cement mortar, providing and fixing threaded fittings with metal inserts for fixing water supply fittings, making proper connection, cutting hole in wall / floor / slab and making good the same etc complete. |
| 84 | 25 mm dia (1 inch) |
| 85 | 20 mm dia (3/4 inch) |
| 86 | Supplying, laying, jointing and testing in position schedule 40 high pressure uPVC pipes pasting type conformingto ASTM-D-1785 (sizes in ID) cutto requiredlengthsincluding all necessary fittings and schedule 80 specials conforming to ASTM-D-2467, such as bends, tees, unions,reducers,flanges& plugs, etc. for underground lines for water supply including earthwork, refilling, dewatering, ramming, consolidating, etc. testing the lines after connecting to mains, rectifying any leakage or defects, etc., complete. |
| 87 | 40 mm dia (1 1/2 inch) |
| 88 | 32 mm dia (1 1/4 inch) |
| 89 | 25 mm dia (1 inch) |
| 90 | 20 mm dia (3/4 inch) |
| 91 | Providing and fixing superior quality forged brass ball valve of approved make including all charges. |
| 92 | 38mm dia |
| 93 | 32mm dia |
| 94 | 25mm dia |
| 95 | 20mm dia |
| 96 | Providing and fixing superior quality Bronze Y-Type Strainer (Screwed) of approved make including all charges. |
| 97 | 38mm dia |
| 98 | Providing and fixing superior quality Bronze Non Return Valve screw type of approved make including all charges. |
| 99 | 40mm dia |
| 100 | 32mm dia |
| 101 | Providing and fixing 15 mm dia CP brass long body tap including CP cup in water line including all charges. |
| 102 | Providing and fixing CP brass Health Faucet with angle valve including all charges. |
| 103 | Providing and fixing 15 mm dia brass bib cock with hose holder, including all charges. |
| 104 | SANITARY WORKS |
| 105 | Supplying, laying, jointing, testing and commissioning ISI marked rigid PVC pipes 6 kg/cm2 for soil & waste pipes conforming to IS:4985 cut to required lengths including all necessary fittings and specials such as tees, elbows, bends, flanges, reducers, end caps, couplings, Ys, WC connectors etc and specials with access doors wherever necessary, fixing in sunken slab / below slab through core cut holes fixed with GI supporting system to proper line and level making proper connection with fittings and jointing with solvent cement, cutting chases/holes in floors / walls / slab making connection to vertical stack, making good the walls and floors etc. complete. (Rate includes fixing pipes with brick / concrete supports inside sunken portion to maintain the required slope / fixing pipes below slab with GI supporting system.) |
| 106 | 110 mm dia |
| 107 | 75 mm dia |
| 108 | 50 mm dia |
| 109 | Supplying, laying, jointing, testing and commissioning ISI marked rigid PVC pipes 6 kg/cm2 for soil & waste pipes conforming to IS:4985 cut to required lengths including all necessary fittings and specials such as tees, elbows, bends, flanges, reducers, end caps, couplings, Ys, etc and specials with access doors wherever necessary, supported by galvanised steel slotted rails fixed on walls / ceiling etc. with grouting / anchor fastener legs, U clamps, cutting chases/holes in floors / walls / slab making connection to soil and waste lines, making good the walls and floors etc. complete for soil, waste, vent and rain water lines in ducts and ceiling level. |
| 110 | 110 mm dia |
| 111 | 75 mm dia |
| 112 | Supplying, laying, jointing, testing and commissioning ISI marked rigid PVC pipes 4 kg/cm2 for Rain Water and Balcony Drain pipes conforming to IS:4985 cut to required lengths including all necessary fittings and specials such as tees, elbows, bends, flanges, reducers, end caps, couplings, Ys, etc, supported by galvanised steel slotted rails fixed on walls / ceiling etc. with grouting / anchor fastener legs, U clamps, cutting chases/holes in floors / walls / slab making connection to soil and waste lines, making good the walls and floors etc. complete for Rain Water and Balcony Drain pipes in ducts and ceiling level. |
| 113 | 160 mm dia |
| 114 | 110 mm dia |
| 115 | Supplying, laying, jointing, testing and commissioning ISI marked rigid PVC pipes 6 kg/cm2 for soil & waste pipes conforming to IS:4985 cut to required lengths including all necessary fittings and specials such as tees, elbows, bends, flanges, reducers, end caps, couplings, Ys, etc and specials with access doors wherever necessary, for underground piping including cost of necessary excavation, dewatering, backfilling, ramming, consolidating etc complete for underground drain lines. |
| 116 | 110 mm dia |
| 117 | 75 mm dia |
| 118 | Providing and fixing PVC floor trap (multi trap), 110mm outer dia with CP grating and 150 mm square grating ring, including all charges. |
| 119 | Supplying and fixing PVC tee 110mm in septic tanks, collection tanks etc. including testing of joints, cost of materials, labour, etc. complete. |
| 120 | Providing and fixing PVC vent cowl to vent pipe already fixed, including all charges. |
| 121 | 110 mm dia |
| 122 | 75 mm dia |
| 123 | Supplying and fixing 100mm PVC gully trap for waste lines including earth work, brick masonry chamber of size 30x30 cm over base concrete of 10 cm thick PCC 1:4:8 using graded stone aggregate 40mm, plastering with cement mortar 1:3, 12mm thick with neat cement flushing coat, grating 150x150mm on inside, cover slab 10 cm thick in RCC 1:2:4 with FRP manhole cover 30x30 cms and frame 25 MT Capacity (HD) etc complete. |
| 124 | Providing and constructing brick masonry manhole in cement mortar 1:6, RCC top slab 150 mm thick, with medium / heavy duty FRP manhole cover, 100 mm thick, base concrete 1:4:8 mix using graded stone aggregate 40mm, inside & outside plastering 12mm thick with cement mortar 1:3 finished with a flushing coat of neat cement and making channels in cement concrete 1:2:4 mix using graded stone aggregate 20mm, neatly finished complete as per standard design including cost of materials, labour, etc. complete. |
| 125 | Inside size 30x30 cm and depth upto 40 cm with FRP manhole cover 30x30 cms and frame 25 MT Capacity (HD) |
| 126 | Inside size 45x45 cm and depth upto 60 cm with FRP manhole cover 45x45 cms and frame 25 MT Capacity (HD) |
| 127 | Supplying and fixing glazed earthenware wash basin 550 x 400 mm or nearest size, with half pedestal including one CP brass pillar cock 15 mm size including connecting pipes with all fittings 32mm dia CP brass waste coupling, 32mm dia waste pipe, angle valve, PVC connection, rag bolt, etc. complete. |
| 128 | Supplying and fixing EWC pan with P or S trap including duroplastic seat and lid, with PVC hinges, 3/6 litres dual flush PVC low level flushing cistern with fittings and brackets, 40mm dia PVC flush bend, over flow pipe with mosquito proof arrangements, angle valve with PVC connection etc. complete including cutting and making good the walls and floors etc. complete. |
| 129 | Providing and fixing white vitreous china large flat back urinal basin of 635x420x395mm size with 15mm CP angle cock, CP spreader with CP connection pipe, CP dome type gratings, TW plugs, screws, etc., including all labour, cutting & making good walls, etc. complete including cutting and making good the walls and floorsetc. complete. |
| 130 | Providing and fixing white vitreous china urinal division plate with teak wood plugs, screws etc., including all labour, sundries etc. complete. |
| 131 | Providing and fixing sanitary fixtures of approved colour including all charges. |
| 132 | Soap Dish |
| 133 | CP towel rod with end fixtures 600mm |
| 134 | Making core cutting in RCC slabs (upto 120 mm thick) using diamond core cutting machine, without cutting the reinforcement as far as possible and sealing the holes drilled in slab for taking pipe lines to ensure watertight filling using rich concrete with liquid polymer admixture and hydro tight coating using crystalline catalyst waterproofing coating, including curing, all hire charges, labour, disposal of debris, scaffolding, sundries etc. complete. for pipes of following sizes. |
| 135 | 110 mm dia (4 inch) |
| 136 | 75 mm dia (2 1/2 inch) |
| 137 | 63 mm dia (2 inch) |
| 138 | 50 mm dia (1 1/2 inch) |
| 139 | 40 mm dia (1 1/4 inch) |
| 140 | 32 mm dia (1 inch) |
| 141 | 25 mm dia (3/4 inch) |
| 142 | Making core cutting in RCC beam (upto 250 mm thick) using diamond core cutting machine, without cutting the reinforcement as far as possible and sealing the holes drilled in slab for taking pipe lines to ensure watertight filling using rich concrete with liquid polymer admixture and hydro tight coating using crystalline catalyst waterproofing coating, including curing, all hire charges, labour, disposal of debris, scaffolding, sundries etc. complete. for pipes of following sizes. |
| 143 | 100 mm dia |
| 144 | 75 mm dia |
| 145 | 63 mm dia |
| 146 | 50 mm dia |
| 147 | 40 mm dia |
| 148 | 32 mm dia |
| 149 | Supply, fixing, testing and commissioning of open well submersible pump and single phase electric motor, with cast iron head, SS shaft, bronze Impeller, and provided with mechanical seal, lifting arrangements, sundries etc. complete.Flow rate 1.50 LPS Head 12 Mts |
| 150 | Supply, fixing, testing and commissioning of open well submersible pump and single phase electric motor, with cast iron head, SS shaft, bronze Impeller, and provided with mechanical seal, lifting arrangements, sundries etc. complete.Flow rate 1.70 LPS Head 18 Mts |
| 151 | ELECTRIFICATION WORKS |
| 152 | OUTDOOR METERING PANEL |
| 153 | SITC of 125A, LT, floor mounted type, dust and vermin proof, free standing, cubical type construction, made out 16SWG CRCA sheet painted with approved colour after degreasing prickling, phosphating etc consisting of the following:(a)Incomer: 125A 4P 36kA MICROPROCESSOR BASED MCCB with 3 O/C, S/C, ROM and 2 Sets of Spreader with Interphase Barrier(b)Bus bar: 125A Aluminium bus bar. (c)Outgoing: 80A 4P MCCB - 4Nos.set at 63A (Provision for fixing 3 phase KWH meter,cut out neutral link,etc,.in 4 outgoings)DIN Rail Surge Protection Device (4+0) Class B&C/ Type 1&2 Tested as per IEC 61643 Part 11:2016 . Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 260KA (8/20µ sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV withstandfor 120 Min : 442 V and with out Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT& the Protection Modes for : L & N toPE . Short- Circuit Current rating (Isccr) – 25kA/50 kA. Back up fuse required more than 315AgG/gL. Health Status Indication required in all cartridge. Total Response time <100nano sec- 1No |
| 154 | Supply |
| 155 | Labour |
| 156 | GSB |
| 157 | SITC of 200A, LT, floor mounted type, dust and vermin proof, free standing, cubical type construction, made out 16SWG CRCA sheet painted with approved colour after degreasing pickling, phosphating etc consisting of the following:(a) Incomer: 200A 4PIsolator -1 No.(b) Bus bar: 200A Aluminium bus bar. (c) Metering: Multi Function meter (A,V,F,PF)-1setand metering CTs200/5A, Class 1, 10VA-3set and 2A Cut out fuses-1set(d) Outgoing: 125A 25kA 4P MCCB-1No,200A 4P Isolator-1Nos,32A 4P MCB-1No.RYB phase indicating lamps (lamps shall be of LED) with control fuses and switches – 1 set. |
| 158 | Supply |
| 159 | Labour |
| 160 | DISTRIBUTION BOARDS |
| 161 | SITC of double cover enclosure of MCB DB IP42/43 for 3phase inclusive of copper/brass bus bar, neutral link and DIN bar including cutting holes on wall,making good the damages colour washing etc as required. |
| 162 | 4 WAY VTPN DB |
| 163 | Supply |
| 164 | Labour |
| 165 | 6 WAY(EVDB) |
| 166 | Supply |
| 167 | Labour |
| 168 | 6 WAYTPNDB ( LDB,PDB OF EACH GODOWN & COMMON DB) |
| 169 | Supply |
| 170 | Labour |
| 171 | 16 WAY SPN DB (UPSDB ) |
| 172 | Supply |
| 173 | Labour |
| 174 | SITC of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required. |
| 175 | 2/6/10/16/25/32 A, 10 kA, SP MCB (C ,B curve) (LDB, PDB, CVDB & UPS DB OUTGOINGS) |
| 176 | Supply |
| 177 | Labour |
| 178 | 2/6/10/16/25/32 A, 10 kA, TP MCB (C ,B curve)( CVDB OUTGOINGS,VDB\"s & EVDB\"s OUTGOINGS FOR DB\"s & ATS ) |
| 179 | Supply |
| 180 | Labour |
| 181 | 40A, TP MCB (C ,B curve)( VDB\"s OUTGOINGS FOR DB\"s ) |
| 182 | Supply |
| 183 | Labour |
| 184 | 63A, TP MCB (C,B curve) (VDB\"s OUTGOINGS FOR DB\"s) |
| 185 | Supply |
| 186 | Labour |
| 187 | 32A DP ISOLATOR (UPS INCOMER AND OUTGOING SIDE ) |
| 188 | Supply |
| 189 | Labour |
| 190 | 10A DP MCB |
| 191 | Supply |
| 192 | Labour |
| 193 | 40A FP ISOLATOR |
| 194 | Supply |
| 195 | Labour |
| 196 | 63A FP ISOLATOR (MAIN VDB1, VDB2, VDB3, EVDB INCOMER & COMMON VDB INCOMER) |
| 197 | Supply |
| 198 | Labour |
| 199 | 125A FP ISOLATOR |
| 200 | Supply |
| 201 | Labour |
| 202 | SITC of 3 Module (100x150x96) indoor-polystyrene AK03 Thermoplastic enclosure on surface complete with connections, testing and commissioning etc. as required.(for theUPS incomer side,MCB (Light control)) |
| 203 | Supply |
| 204 | Labour |
| 205 | 10A DP MCB |
| 206 | Supply |
| 207 | Labour |
| 208 | RCBO |
| 209 | SITC offollowing rating, residual current circuit breaker with overload protection (RCBO), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 210 | 63A ,4P RCBO, 100mA |
| 211 | Supply |
| 212 | Labour |
| 213 | 63A ,4P RCBO, 30mA |
| 214 | Supply |
| 215 | Labour |
| 216 | 40A ,4P RCBO, 30mA |
| 217 | Supply |
| 218 | Labour |
| 219 | 40A ,4P RCBO, 100mA (PDBs INCOMER) |
| 220 | Supply |
| 221 | Labour |
| 222 | 32A ,4P RCBO, 30mA (LDBs & COMMON DB INCOMER) |
| 223 | Supply |
| 224 | Labour |
| 225 | 16A ,DP RCBO, 100mA (water pump control) |
| 226 | Supply |
| 227 | Labour |
| 228 | 1kVA UPS (SINGLE PHASE IN AND OUT) |
| 229 | SITC ofof 1kVA UPS Single phase in and out standalone UPS. INX SERIES,STANDARDAND LONG BACKUPMODEL SINGLE PHASE 1KVA/36V DC input 1 phase in and out tower type online pure sine wave double conversion UPS system with latest technology with external exide make 12V 26AH smf battery 3 numbers for the battery backup 30min.Input pf >0.99 at nominal voltage (input voltage 230V), input voltage range 110-300 Vac, 50Hz Single Phase, output 230V, It shall be 100% generator compatible, with Efficiency > 88% and output power factor 0.8 (1kVA= 0.8kw), and including all accessories etc as required.(FOR COMMON AREA) |
| 230 | Supply |
| 231 | Labour |
| 232 | Wiring |
| 233 | Following items are for internal wiring works. Consealed wiring is proposed everywhere, unless and otherwise mentioned separately .Conduting shall be done on surface /concealed /RCC / wall, including providing and fixing IS marked suitably sized medium grade rigid PVC conduits, fittings, accessories, etc. Cost of civil works like cutting grooves on wall/RCC, fixing conduits, filling the grooves with cement mortar, making good thereof, etc. shall also be included in the rates. The tenderer shall study the drawings carefully for assessing the length of circuits from DB to Switch Boards, and from Switch Boards to Points for Point and Circuit Wiring. This would help tenderers to quote for competitive rates. |
| 234 | Light Point Wiring (Primary points) |
| 235 | Supply wiring testing and commissioning ofPoint wiring for Light point/fan point/exhaust fan point/call bell point using 1.5 Sq.mm (including earth wire 1 sqmm green) HRFR PVC insulated copper conductor stranded cable, in existing concealed/open ISI marked PVC medium grade conduit (rigid / flexible upto fixture) complete with Modular type Switch with non metalic inner and outer cover, suitable GI metal boxes,other accessories, ceiling roses, etc. complete. |
| 236 | Supply |
| 237 | Labour |
| 238 | Light Point Wiring (Secondary points) |
| 239 | Supply ,wiring testing and commisioning of Secondary Point wiring for light point/fan point/exhaust fan point/call bell pointusing 1.5 Sq.mm (including earth wire 1 sqmm green) HRFR PVC insulated copper conductor stranded cable, in existing concealed/open ISI marked PVC medium grade conduit (rigid / flexible upto fixture) complete without Switch. |
| 240 | Supply |
| 241 | Labour |
| 242 | 2-Way Point wiring |
| 243 | Supply,Wiring testing and commisioning ofPoint wiring for 2-way control points using 1.0 Sq.mm (including earthing) HRFR PVC insulated stranded copper conductor cable, in existing concealed/open ISI marked PVC medium grade conduit (rigid / flexible upto fixture), 2 Nos. 2 way 5/6A Modular type switch with non metalic outer and inner cover, suitable GI metal boxes, other accessories, ceiling roses, etc. complete. |
| 244 | Supply,Wiring for 2 light controlled by two way switch in the above system. |
| 245 | Supply |
| 246 | Labour |
| 247 | 6A socket outlets (independent position) |
| 248 | SITC of 6A plug points in independent positions 6A modulartype shuttered universal plug socketcontrolled by 6A switch with moulded front plate, housed in a suitable factory built MS box.Giving connections, earthing as detailed above etc complete as required(Socket & Switch at independent locations). (For Computer points). |
| 249 | Supply |
| 250 | Labour |
| 251 | 6A socket outlets (combined position) |
| 252 | SITC of 6A plug points in combined positions fixing 6A modulartype universal plug socketcontrolled by 6A switch mounted in a suitable factory built MSbox with earthing facilities as per standards. (Circuit from same switch board)(Socket+Switch at combined locations along with other switches).(For Computer points.) |
| 253 | Supply |
| 254 | Labour |
| 255 | 16A Power socket outlets |
| 256 | SITC of 16 Amodular type power plug socket controlled with 16A modular type switch in same switch board, mounted on a suitable factory built MS box giving interconnections etc complete as required and as directed by engineer in charge. |
| 257 | Supply |
| 258 | Labour |
| 259 | 32A Industrial socket outlets |
| 260 | SITC of wall mounted single phase 32A industrial socket Distribution box with DIN RAIL outlet with IP 67,UV resistant &Lite weightHalogen Thermoplastic enclosure on surface complete with connections, testing and commissioning etc. as required. |
| 261 | Supply |
| 262 | Labour |
| 263 | AC Point |
| 264 | SITC of 20 amps Modular type Switch with indicator complete with non metallic inner & outer plates, suitable metal boxes, etc. on surface/ recess on wall or below counter etc with all necessary accessories as required.(AC Control switch) |
| 265 | Supply |
| 266 | Labour |
| 267 | SITC of 20 amps Modular type Socketcomplete with non metallic inner & outer plates, suitable metal boxes, etc. on surface/ recess on wall or below counter etc with all necessary accessories as required.(AC Socket) |
| 268 | Supply |
| 269 | Labour |
| 270 | Fan Regulator |
| 271 | SITC of Modular type, 5 speed step electronic fan regulator 100W ratingcomplete with non metallic inner & outer plates, suitable metal boxes, etc. on surface/ recess with all necessary accessories as required. |
| 272 | Supply |
| 273 | Labour |
| 274 | SITC of extra conduit down rod of 30 cm length G.I.pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 275 | Supply |
| 276 | Labour |
| 277 | CONDUIT & FIXING ACCESSORIES |
| 278 | Supply, Laying medium gauge PVC conduit conforming to IS (9537/1983 Part III) open or concealed as required in wall or slab. For wall use saddle clip, nails, tie wire etc. as required and for slab use suitable solvents, tying with binding wire etc as required. (for light points, circuits 6A, Industrial sockets, CCTV, etc) |
| 279 | 20 mm for floor/wall |
| 280 | Supply |
| 281 | Labour |
| 282 | 25 mm for floor/wall |
| 283 | Supply |
| 284 | Labour |
| 285 | 32 mm for floor/wall |
| 286 | Supply |
| 287 | Labour |
| 288 | Supply, Laying of flexible conduit |
| 289 | Supply |
| 290 | Labour |
| 291 | CIRCUIT MAINS |
| 292 | Circuit Submain wiring in PVC conduit:Supply,Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of HRFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 293 | 2 x 1.5 sq. mm + 1 X 1 sq. mm earth wire(light point ) |
| 294 | Supply |
| 295 | Labour |
| 296 | 2 x 2.5 sq. mm + 1 X 1.5 sq. mm earth wire(DB TO SPN DB- GODOWN) |
| 297 | Supply |
| 298 | Labour |
| 299 | 2 x 4 sq. mm + 1 X 2.5 sq. mm earth wire(For IndustrialSocket ,AC Points and VDB to UPS) |
| 300 | Supply |
| 301 | Labour |
| 302 | 4 x 6 sq. mm + 1 X 4 sq. mm earth wire(For VDBs to PDBs and LDBs). |
| 303 | Supply |
| 304 | Labour |
| 305 | Blank plates |
| 306 | Supply,Fixing ofSwitch blank plate for dummy points as required. |
| 307 | Supply |
| 308 | Labour |
| 309 | Supply,Fixing ofMCB SP blank plate for dummy points as required. |
| 310 | Supply |
| 311 | Labour |
| 312 | SITC ofLight Fixtures |
| 313 | Highbay Light Luminaire-100W( UNO LH21-122-090-57-X1) |
| 314 | Supply |
| 315 | Labour |
| 316 | Ceiling Light -12W( Make: WIPRO-LD06-111-XXX-57-XX) |
| 317 | Supply |
| 318 | Labour |
| 319 | Wall lamp -10W(Make: WIPRO LW07-141-XXX-57-G1) |
| 320 | Supply |
| 321 | Labour |
| 322 | Mirror light-5W( Make:Havells Pride plus) |
| 323 | Supply |
| 324 | Labour |
| 325 | Ceiling Fan-75W(Make:CromptonAura prime 1200MM) |
| 326 | Supply |
| 327 | Labour |
| 328 | Wall Fan-60W (Make:Crompton Torpedo 400-MM) |
| 329 | Supply |
| 330 | Labour |
| 331 | Bulk head-10W(Make: WiproLW07-141-XXX-57-G1) |
| 332 | Supply |
| 333 | Labour |
| 334 | Tube light-20W( Make: Wipro LL20-221-XXX-65NE3 ) |
| 335 | Supply |
| 336 | Labour |
| 337 | Exhaust fan-40W ( Make:Havells Ventil air-DXW-100) . |
| 338 | Supply |
| 339 | Labour |
| 340 | Industrialtype exhaust fan -150W(Make: Almonard 380mm) |
| 341 | Supply |
| 342 | Labour |
| 343 | CCTV |
| 344 | SITC of Outdoor type IR Fixed Bullet Camera with below specifications as minimum and with all the necessary accessories for the installation - 4MP Resolution - 3.6mm Fixed Lens - H.265, MJPEG codec - IR - 30 meters - 120dB WDR - IP67 |
| 345 | Supply |
| 346 | Labour |
| 347 | SITC of NVR with below specifications as minimum and with all the necessary accessories for the installation -16 Channels - H.265, H.264, MJPEG compression - HDMI and VGA independent outputs |
| 348 | Supply |
| 349 | Labour |
| 350 | SITC ofHDD 10 TB WD SATA as required to maintain storage. |
| 351 | Supply |
| 352 | Labour |
| 353 | SITC of Network Rack-6U |
| 354 | Supply |
| 355 | Labour |
| 356 | CAT6 Patch Cord - 1 Meter |
| 357 | Supply |
| 358 | Labour |
| 359 | SITC of 8 portswitch |
| 360 | Supply |
| 361 | Labour |
| 362 | SITCof LED Displays 21/22\" Inch for CCTV Monitoring with all the necessary wall mounting accessories. |
| 363 | Supply |
| 364 | Labour |
| 365 | TELEPHONE,TV,NETWORK SYSTEM |
| 366 | SITC of modular type Co axial T.V socket mounted in suitable factory built MSbox with earthing facilities etc complete as per standards. |
| 367 | Supply |
| 368 | Labour |
| 369 | Supply,Laying of coaxial cable through existing 25mm PVC conduit for TV sockets and giving connections as required. |
| 370 | Supply |
| 371 | Labour |
| 372 | Supplying ,Laying of ISI marked 6 core single mode OFC on surface /concealed /RCC / wall,in existing concealed/open ISI marked suitably sized medium grade rigid PVC conduits, fittings, accessories, etc. |
| 373 | Supply |
| 374 | Labour |
| 375 | SITC of CAT 6 RJ 45 Sockets for Data point with suitable size of GI box with modular plate and cover infront on surface or in recess including connection as required. |
| 376 | Supply |
| 377 | Labour |
| 378 | Supply and laying of CAT 6 cable through existing 25mm PVC conduit for wifi ,data, camera point connections. |
| 379 | Supply |
| 380 | Labour |
| 381 | Supply and laying of Modular type telephone 2 line socket RJ-11 with shuttercomplete with non metallic inner & outer plates, suitable metal boxes, etc. on surface/ recess with all necessary accessories as required. |
| 382 | Supply |
| 383 | Labour |
| 384 | Supply and laying of 2 pair telephone cable of size 0.50 dia annealed copper conductor PVC insulated and PVC sheathed unarmoured cable. Wiring shall be done onin existing concealed/open ISI marked suitably sized medium grade rigid PVC conduits, fittings, accessories,cutting and finishing, etc.2 Pair cable |
| 385 | Supply |
| 386 | Labour |
| 387 | External Lightning Protection System |
| 388 | SITC of Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rodmeter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load.All air terminal must have Interception Tip at the Top of air terminal.Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports.Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. |
| 389 | 2 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories (Total 3 Sets) |
| 390 | SITC of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below:Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5) with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. |
| 391 | Conductor with Down Conductor Holder made of whether resistant plastic holder @ every 0.75 meters (Total 70 M) |
| 392 | SITC of Cross Connector/T Connector/Folding Clamp/Clamping Shoe/ Expansion Piece: to route vertical down conductor /mesh formation made of Aluminium Ferrule using screw free joints. Folding Clamp/Clamping Shoe for metal panels (up to 20mm thickness of the metal frame): Folding clamp/clamping shoe for metal frame thickness up to 20mm, made of stainless steel SS 304/316 grade , conforms to the requirements accordingto (IS/IEC 62305). Expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector:using Aluminium Ferrule. Quick installation using crimp joints. Conforms to the requirements according to(IS/IEC 62305). Make sure all joints are strong and will be inspected at site. Galvanised Iron joints are not permitted to avoid risk of corrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required. (Total 15 Nos) |
| 393 | Supply |
| 394 | Labour |
| 395 | SITC of Stainless Steel Test Joint suitable with suitable Outdoor Enclosure: For 8mm dia solid round aluminium conductor & 10mm dia copper coated solid steel round conductor having 100 microns of copper bonding . Conforms to the requirements accordingto (IS/IEC 62305).The enclosure should be outdoor glass-fibre reinforced polycarbonate opaque having minimum inner dimension of 75mm x 75 mm x 50 mm. The test link has to be straight and needs minimum 4 mounting screws for strong joints. Inspection of bimetallic corrosion at site required. Seperation of 8mm Aluminium & 10mm Copper bonded steel is required for future inspection and contractor has to make sure both conductors should not touch eachg other to avoid bimetallic corrosion. Single bolt joints are not permitted. Govt approved Indian labs test certificate required. |
| 396 | Supply |
| 397 | Labour |
| 398 | Supply and laying copper coated steel solid round conductor 10mm diameter from earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. After test link needs to be routed inside Heavy duty conduit to avoid touch potential till ground level. Govt approved Indian labs test certificate required.(Total 50M) |
| 399 | SITC of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 3048mm length (10 feet), having a diameter of 20mm with copper bonding thickness of 250 microns as per UL 467.The Rod has to be either continuous or with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA. The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend test with out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Ordinary Stainless steel/Copper alloy universal clamps are not recommended. For self coupling peg & bore arrangement rod needs Impact point on the bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances. The mineral compound is required to have minimum 17.5 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. Concrete Earth electrode inspection chamber with weight bearing capacity of 60KN. The dimension shall be 290mmx 290mmx 209mm. Govt approved Indian labs test certificate required. (Total 9 Set) |
| 400 | Supply |
| 401 | Labour |
| 402 | Supply and laying of following size copper earth strip /wire through walls, trench etc. including giving terminations. |
| 403 | 25 x 3 mm copper strip |
| 404 | Supply |
| 405 | Labour |
| 406 | No.10 SWG Copper wire |
| 407 | Supply |
| 408 | Labour |
| 409 | No.8 SWG Copper wire |
| 410 | Supply |
| 411 | Labour |
| 412 | No.4 SWG Copper wire |
| 413 | Supply |
| 414 | Labour |
| 415 | Plate Earthing |
| 416 | SITC ofplate earthing as per I.S 3043 with 1200x1200x12 mm CI earth plate with required length of 38.1 mm dia. \"B\" class G.I watering pipe extending to the middle of the plate and clamped to the plate with minimum 2 Nos. GI clamps of size 50x6 mm flat with 50x10 mm, GI bolt and nuts including drilling necessary holes, providing G.I funnel with weld mesh, fixing GI strip of size 50 x 6mm with minimum length of 30 cm clamped with 50x6 mm GI flat using 50x10 mm GI bolt and nut as test joint to the watering pipe, fixing 2 Nos. G.I strip of size 50x6 mm from test joint to earth plate, |
| 417 | filling with homogeneous mixture of charcoal, common salt and river sand around the earth plate, upto a distance of 15 cm on either side, filling the rest of the portion with excavated soil including watering and ramming, providing brick work (20cm masonry) at the top in 1:6 cement mortar, plastering inside and top of the man hole with 12mm thick 1:6 cement mortar and providing 45 cm x 45 cm 1:2:4 RCC slab 50 mm thick as covering at the top. (For DG & Panel) |
| 418 | Supply |
| 419 | Labour |
| 420 | Pipe Earthing |
| 421 | SITC ofISI Pipe earthing as per IS 3043 with 3.5 Metre long 38.1 mm dia. \"B\" class G.I pipe, providing G.I funnel with weld mesh, fixing G.I strip of size 50x6 mm with minimum length of 30 cm clamped with 50x6 mm G.I flat using 50x10 mm G.I bolt and nut at top of the G.I pipe as test joint, filling around the G.I pipe at a radius of 15 cm with a homogeneous mixture of charcoal, common salt and river sand upto a height of 2.5 Metre from the bottom, filling the rest of the portion with excavated soil including watering and ramming providing brick work (20 cm) masonry at the top in 1:6 cement mortar, plastering the inside and top of the manhole with 12 mm thick 1:6 cement mortar, and providing 45cmx45cm 1:2:4 RCC slab 50 mm thick as covering at the top. |
| 422 | Supply |
| 423 | Labour |
| 424 | 125kVA GENERATOR |
| 425 | SITC of 125kVA, 3phase, 415V, D.G set consisting of the following. |
| 426 | a) Alternator: 125kVA, 415V, 3 phase alternator with Automatic voltage regulator. |
| 427 | b) Diesel Engine: 156bhp, 4 cylinder diesel engine with base frame made of channel suitable for coupling with alternator. |
| 428 | c) Control Panel: 200A 25kA 4P MCCB set at 175A ,1 Set volt meter, 3 Nos. ammeters with CT etc. |
| 429 | d) Fuel tank |
| 430 | e) Miscellaneous materials like Battery, Antivibration mountings, residential silencer, Necessary flanges, flexible couplings, fuel connectors, valves etc. |
| 431 | Supply |
| 432 | Labour |
| 433 | Supply and laying of following size of exhaust pipe including all fabricated supports. |
| 434 | 100mm |
| 435 | Supply |
| 436 | Labour |
| 437 | 125mm |
| 438 | Supply |
| 439 | Labour |
| 440 | CABLE TRAY |
| 441 | Fabrication, supply and fixing of followingsizes perforated cable trays, supports etc using angle iron and flats including painting using 2 coats of synthetic enamel paint over zinc chromate metal primer. |
| 442 | 150mm Width x 50mm Height |
| 443 | Supply |
| 444 | Labour |
| 445 | 250mm Width x 50mm Height |
| 446 | Supply |
| 447 | Labour |
| 448 | LT CABLES |
| 449 | Supply and Laying of Aluminium conductor, PVC insulated, PVC Sheathed, armored, cable for working voltageup to 1.1KV, through wall/tray,in existing trench etc. |
| 450 | 3 .5 x 150mm2 (GCP to GSB) |
| 451 | Supply |
| 452 | Labour |
| 453 | 3 .5 x 70mm2 (GSB to Fire panel) |
| 454 | Supply |
| 455 | Labour |
| 456 | 3 .5 x 50mm2 (GSB to EVDB) |
| 457 | Supply |
| 458 | Labour |
| 459 | 4 x 25 mm2 (MC to VDB1,2,3,4, COMMON VDB) |
| 460 | Supply |
| 461 | Labour |
| 462 | 2X4mm2 (Common VDB to Water Pump 1&2) |
| 463 | Supply |
| 464 | Labour |
| 465 | 6 x 2.5mm2 Cu (DG AMF Control) |
| 466 | Supply |
| 467 | Labour |
| 468 | END TERMINATION |
| 469 | Supply of materials and termination for cable of following size using brass siemens type gland and AluminiumPalm/banana type socket. |
| 470 | 3 .5 x 150mm2 (GCP to GSB) |
| 471 | Supply |
| 472 | Labour |
| 473 | 3 .5 x 70mm2 (GSB to Fire panel) |
| 474 | Supply |
| 475 | Labour |
| 476 | 3 .5 x 50mm2 (GSB to EVDB) |
| 477 | Supply |
| 478 | Labour |
| 479 | 4 x 25 mm2 (MC to VDB1,2,3,COMMON VDB) |
| 480 | Supply |
| 481 | Labour |
| 482 | 2X4mm2 (Common VDB to Water Pump 1&2) |
| 483 | Supply |
| 484 | Labour |
| 485 | 6 x 2.5mm2 Cu (DG AMF Control) |
| 486 | Supply |
| 487 | Labour |
| 488 | Earth Bench |
| 489 | Supply and clamping 25 x 3 mm tinned Cu. Earth bench of the following lengths on the surface of wall for connecting earth continuity leads at required locations. |
| 490 | 60 cm Earth Bench |
| 491 | Supply |
| 492 | Labour |
| 493 | 30 cm Earth Bench |
| 494 | Supply |
| 495 | Labour |
| 496 | Supply of following items: |
| 497 | Supply & laying of 1100 V grade Synthetic mat of size 2 m x 1m x2mm in front of MSB and Panels as per IS 5424 |
| 498 | Supply |
| 499 | Labour |
| 500 | Supply and fixing of suitably painted, round bottom type, 9 litre capacity G.I fire bucket with clamps. |
| 501 | Supply |
| 502 | Labour |
| 503 | Supply and fixing of 5 kg Dry Chemical Powder type fire extinguisher. The fire extinguisher shall confirm to IS 13849, IS:4308 & IS:2171 for Class B & C fires |
| 504 | Supply |
| 505 | Labour |
| 506 | Supply of one set of first aid box with required medicines and first aid items. |
| 507 | Supply and fixing of laminated artificial respiration chart & instructions both in English & Malayalam in the Sub-station. |
| 508 | Supply of Caution Board ( LT) |
| 509 | APPROVALS & SANCTIONS |
| 510 | Preparation of all drawings submitting and getting approval from KSEB/Electrical inspectorate, submitting of Completion certificates and arranging inspection, getting sanction and energization certificate etc, for commissioning of the whole installation in the premises. |
| 511 | FIRE PUMP ROOM |
| 512 | MAIN PUMP : Supply, Installation, testing and commissioning of Horizontal mounted end suction Electric motor driven Pump set suitable for automatic operation rated for 2280LPM at50MWC, high efficiency, volute type with cast iron casing, cast iron impeller pump coupled to a squirrel cage induction motor of 50 HP@65 Mtr Head, screen protected drip proof. The operating voltage is 415v 3 phase 50 Hz. The pump-set is of foot mounted type including all accessories such as standard coupling, coupling guard, common base-frame, foundation bolts, etc. complete |
| 513 | JOCKEY PUMP : Supply Installation, Testing and Commissioning Electrically driven Mono block Jockey pump having capacityof 180 LPM at 50MWC with all the necessary accessories operating on 3 Ph. 50 Hz. 415 V AC supply including foundation bolts etc. complete. The Pump set shall be of 10 HP @ 70mtr Head. Jockey pump. |
| 514 | Supply, installation, testing and commissioningof Diesel Engine driven high pressure centrifugal firepump, suitable for automatic operation consisting of the following: a) Horizontal type, centifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm at the highest and farthest outlet at specified flow of 2280 lpm at 65 m head conforming to IS 1520 b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 Volts electric starting equipment, suitable batteries, battery charger, diesel tank of adequate capacity to run the pump for 4 hrs, control panel for diesel engine pump, exhaust pipe extended upto 1 m outside pump house duly insulated, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, pained with post office red colour etc. as required. c) Commonbaseplate for (a) and (b) from M.S. Channel for required size.d. Suitable cement concrete foundation with cement concrete plaster etc., with anti-vibration arrangement of cushy foot mountingsand provide necesssary cabling/earthing as per IS standards complete. |
| 515 | Supply Installation, Testing and Commissioning of Electrically driven monoblock Booster Pump having capacity 450 LPM at 35 Mtr with all the necessary accessories, operating on 3Ph. 50Hz, 415V AC supply including foundation bolts, ect complete. The pump shall be of 7.5 HP terrace pump |
| 516 | Supply, installation, testing and commissioning Butterfly Valve of the following size best in commercial quality with non-rising SS internals |
| 517 | 150 mm dia |
| 518 | 100 mm dia |
| 519 | 80 mm dia |
| 520 | Supply, installation, testing and commissioning of Non Return Valve of following sizes without bye pass arrangements wafer check type eith cast iron body and flanges |
| 521 | 150mm dia |
| 522 | 80 mm dia |
| 523 | Supply, Installation, Testing & Commissioning of Y Type Strainer |
| 524 | 150 mm dia |
| 525 | Supply, installation, testing and commissioning of Air Release Valve 25mm with Ball Valve 25mm dia |
| 526 | Supply Installation Testing and Commissioning of Pressure Switch bellow type for the automatic operation as approvedand instructedby the Engineer In Charge |
| 527 | Supply, Installation, Testing and Commissioning of Pressure Guage burden typewith 0 to 200 PSI range 3\" dial as approved and instruced by the Engineer In Charge |
| 528 | Supply, Fabrication, Erection, testing & commissioning of Air cushion vessel MS to withstand 15 kg/cm2 pressure, 200 mm dia and height of 120cm, with automatic air release cock Bronze make 20mm dia, drain valve, shut off arrangement etc. complete |
| 529 | Above Ground piping Pump Room: Supply, installation, Testing, and Commissioning of MS class \"B\" pipes confirming to IS:1239 Part-I with malleable specials confirming to IS:1239 Part-II such as elbows, reducers, flanges etc. including cutting, welding, fixing on walls, ceiling by using suitable supports of following sizes with fabricated welded joints with necessary fittings / specials. The pipe shall be painted with two coats of primer and two coats of Epoxy paint of Fire Red colour / shade. |
| 530 | 200mm dia |
| 531 | 150mm dia |
| 532 | 80mmdia |
| 533 | 25mmdia |
| 534 | Supply, Installation, Testing and Commissioning of Fire Hydrant System Panel for Electrical Main pumps, Stand by Pump and Jockey pumps incorporating automatic star delta switch gear rated for the motor HP. The Control panel shall be duly painted with 2 coats of anti-corrosive primer and Epoxy paint of Fire Red Colour fabricated out of 16SWG CRCA sheet floor / wall mounted type complete, and shall include necessary indications lamps for the RYB phase showing the power supply conditions, ammeter with clear indications for motor full load current, voltmeter with selector switch, control and power terminals, etc. with L&T / SIEMENS / BCH accessories etc. as per electrical Inspectorate Standards, excluding cabling upto the panel |
| 535 | SUPPLY, INSTALLATION TESTING AND COMMISSIONING OF FIRE HYDRANT & SPRINKLER SYSTEM |
| 536 | Supply, Installation, Testing and Commissioning of Hydrant Valve S.S with ISI of 63mm size oblique type with instantaneous hose coupling adaptor |
| 537 | Supply, Installation, Testing and Commissioning of Branch Pipe with SS short branch pipe ISI marked with 63mm female instentaneous lnlet made of gunmetal, male threaded outlet, complete, fitted with hexagonal based nozzle heavy quality confirming to IS: 903 etc complete |
| 538 | Supply, Installation, Testing and Commissioning of Single door Hose Box suitable to accommodate one of 15M hose pipe, with male and female couplings and one branch pipe. The cabinet is made of 1.5mm (minimum) MS sheet, glass fronted with hinged door and lock. The cabinet The cabinet shall be powder coated painted to scarlet red colour on outside and off white on inside and should have the followingdimensions (W-38, H-65, and D-25 all in cm) |
| 539 | Supply, Installation, Testing and Commissioning of Double door Hose Box suitable to accommodate two of 15M hose pipe, with male and female couplings and one branch pipe. The cabinet is made of 1.5mm (minimum) MS sheet, glass fronted with hinged door and lock. The cabinet shall be powder coated painted to scarlet red colour on outside and off white on inside and should have the followingdimensions (W-76, H-65, and D-25 all in cm) |
| 540 | Supply, Installation, Testing and Commissioning Fire Fighting Hose confirming to IS:636, in 15 Mtrs. Length of 63 mm dia, with heavy duty SS couplings |
| 541 | Supply, Installation, Testing and Commissioning of First Aid Hose Reel wall mounted, swinging typefitted with 20mm dia X 30 Mtr long, high pressure hose with 5mm outlet PVC nozzle with shut off valve CONFORMING to IS 884-1969 |
| 542 | Supply, installation, testing and commissioning of Fire Brigade intet (FBI) consisting 4 Nos 63 mm dia inlentvalve of gun metal conforming to IS complete. |
| 543 | Supply, installation, testing and commissioning of Tank Filling intet (TFI) consisting 3 Nos 63 mm dia inlentvalve of gun metal with footvalve assemblyconforming to IS complete. |
| 544 | Above Ground piping: Supply, installation, Testing and Commissioning of MS class \"B\" pipes of following sizes confirming to IS:1239 Part-I with malleable specials confirming to IS:1239 Part-II such as elbows, reducers, flanges etc. including cutting, welding, fixing on walls, ceiling by using suitable supports of following sizes with fabricated welded joints with necessary fittings / specials. The pipe shall be painted with two coats of primer and two coats of Epoxy paint of Fire Red colour / shade. |
| 545 | 150 mm dia |
| 546 | 100 mm dia |
| 547 | 80 mm dia |
| 548 | 65 mm dia |
| 549 | 50 mm dia |
| 550 | 40 mm dia |
| 551 | 32 mm dia |
| 552 | 25 mm dia |
| 553 | Under Ground Piping: Supply, erection, testing and commissioning of MS class \"B\" pipes confirming to IS:1239 Part-I with malleable specials confirming to IS:1239 Part-II such as elbows, reducers, flanges etc. including necessary earthwork excavation, backfilling, cutting, welding, laying underground by using suitable supports of following sizes with fabricated welded ioints with necessary fittings / specials. The pipes shall be painted with two coats of primer and two coats of Epoxy paint of Fire Red colour / shade with wrapping, required overlaps, trimming etc. complete. |
| 554 | 100 mm dia |
| 555 | 150 mm dia |
| 556 | Supply, installation, testing and commissioning of Butterfly Valve of the following size best in commercial quality with non-rising SS internals |
| 557 | 150 mm dia |
| 558 | 80 mm dia |
| 559 | 65 mm dia |
| 560 | Supply installation Testing and Commisioning of CI Ball Valve |
| 561 | 25mm dia |
| 562 | Supply,installation,Testing and Commissioning of 19mm nominal bore quatrizoid bulb type Sprinkler of approved make, K-factor 5.6, chrome finished, suitable for operating at 68 degree C. The fixing shall be done as per IS sepecifications and as instructed by the Engineer In Charge |
| 563 | PendantType |
| 564 | Supply, installation, Testing and Commissioning of Flow Switch of approved make including all charges |
| 565 | SUPPLY AND INSTALLATION OF CONVENTIONAL FIRE ALARM SYSTEM |
| 566 | Supply installation Testing and Commisioning of ABS Red cov Call Point, Flush Mounting, Glass. Back Box For MCP, all aceesoris etc. complete |
| 567 | Supply, Installation, Testing and Commissioning ofwall mounted ABS Hooter including all accessories like back boxes, glands, terminating lugs etc. complete |
| 568 | 4 Zone Fire Alarm Panel :- Supply installation testing and commissioning of 4 zone microprocessor based Fire Alarm Control Panel with necessory accessories with battery backup. |
| 569 | Smoke Detector : Supply, Installation, Testing and Commissioning of Conventional Smoke Detectors including all accessories like junction boxes, glands, terminating lugs etc. complete. |
| 570 | Heat Detector : Supply, Commissioning of Conventional Heat Detector including all accessories like junction boxes, glands, terminating lugs etc. complete. |
| 571 | Supply, lnstallation, Testing and Commissioning of 2 core x 1.5 Sqmm FRLS Copper armoured PVC insulated cable confirming to relevant IS Fire Protection Laws, including termination,Junction boxes etc, complete as per specifications as required |
| 572 | Supply, lnstallation, Testing and Commissioning of 20 mm PVC Conduit including all accessories like junction boxes, saddles, etc. complete |
| 573 | Supply, lnstallation, Testing and Commissioning of 2 core x 1.5 Sqmm FRLS flexible copper PVC insulated cable confirming to relevant IS Fire Protection Laws, including termination etc, complete as per specifications as required |
| 574 | SUPPLY AND INSTALTATION OF FIRST AID FIRE EXTINGUISHER SYSTEM |
| 575 | Supply and fixing of Dry chemical powder type 4 Kg capacity Fire Extinguishers suitable for A B & C classes of fire, Stored Pressure type, filled with Mono Ammonium Phosphate based powder, pressurised with Nitrogen gas, complete with pressure indicating gauge, initial charges, discharge hose, wall mounting brackets etc. and with ISI mark. |
| 576 | Supply and installation of 9 LtrMechanical Foam type Extinguishers. |
| 577 | Supply and installation of 5 Kg DCP type Modular Extinguishers. |
| 578 | SIGNAGES |
| 579 | Supply, Installation of LED type \"Fire Exit\" signages |
| 580 | Supply, Installation of Auto Glow \"Fire Duct\" signages |
| 581 | Supply, Installation of Auto Glow \"Exit\" Signages |
| 582 | Supply, Installation of Auto Glow \"Assembly Point\" Signages |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail