}

Construction Of 120 Men Barrack, Osap 3Rd Bn., Koraput, koraput-Odisha

Orissa State Police Housing And Welfare Corporation Limited has published Construction Of 120 Men Barrack, Osap 3Rd Bn., Koraput. Submission Date for this Tender is 18-10-2025. Building Work Tenders in koraput Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

51502406
Construction Of 120 Men Barrack, Osap 3Rd Bn., Koraput
Tender
Indian
Odisha
Koraput
18-10-2025

Tender Details

construction Of 120 Men Barrack, Osap 3Rd Bn., Koraput-2 50000001Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth.Ground Floor 3 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor 4 50000008Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. Ground Floor 5 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor 6 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor 7 First Floor 8 Second Floor 9 Third Floor 10 Forth Floor 11 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor 12 First Floor 13 Second Floor 14 Third Floor 15 Forth Floor 16 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor 17 First Floor 18 Second Floor 19 Third Floor 20 Forth Floor 21 50000023Priming one coat with any approved primer on new work to give an even shade including scaffolding and cleaning the surface before application etc.complete. (FOR OUTSIDE)Ground Floor 22 First Floor 23 Second Floor 24 Third Floor 25 Forth Floor 26 50000025Wall painting two coats with plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. Ground Floor 27 First Floor 28 Second Floor 29 Third Floor 30 Forth Floor 31 50000035providing & fixing ceramic tiles of approved size in dado & skirting over cement plaster 1:3, 12mm thick jointed with with neat white cement slurry including cost of all material labour T & P etc.complete. Ground Floor 32 First Floor 33 Second Floor 34 Third Floor 35 50000036 Floor Tile flooring over cement plaster 1:1 25mm. thick bed with cost of all materials, labours T & P etc.complete. Ground Floor 36 First Floor 37 Second Floor 38 Third Floor 39 50000044Providing anti-termite treatment including labour and materials etc complete.(As per specification confirming to IS Code 6313-3(2001)part-3 ).Ground Floor 40 First Floor 41 Second Floor 42 Third Floor 43 Forth Floor 44 50000057Drip course mould plaster 1:4 (1:cement :4sand) including necessary scaffolding curing etc. complete at all depth and height.Ground Floor 45 First Floor 46 Second Floor 47 Third Floor 48 Forth Floor 49 50000063 One coat of priming with approved primer over new wood work. Ground Floor 50 First Floor 51 Second Floor 52 Third Floor 53 Forth Floor 54 500000712.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard grinite chips on new work including cost of labour,material,T&P etc all complete. Ground Floor 55 Third Floor 56 Forth Floor 57 50000742Painting two coats of Anti-fugal weather coat water proofing paint including scaffolding and cleaning the surface before application. Ground Floor 58 First Floor 59 Second Floor 60 Third Floor 61 Forth Floor 62 50000879Supplying and fitting, fixing of chequer tiles over cement mortar 1:1, 25mm. thick with cost of all materials, labour, T & P etc.complete. Ground Floor 63 50000884Enamel painting two coats including cost of all materials cleaning,brushes,putty etc. Ground Floor 64 First Floor 65 Second Floor 66 Third Floor 67 Forth Floor 68 50000964Providing and Fixing of Granite Flooring in floors, Treads and Landings over 25mm thick bed of cement mortar 1:1 jointed with neat cement slurry mixed with pigment to match the shades of the Granite including cleaning etc.Ground Floor 69 First Floor 70 Second Floor 71 Third Floor 72 50001303Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & PlinthGround Floor 73 50001305Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure.Ground Floor 74 First Floor 75 Second Floor 76 Third Floor 77 Forth Floor 78 50001311Fly Ash brick masonary in cement mortar 1:4:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure.Ground Floor 79 First Floor 80 Second Floor 81 Third Floor 82 50001633Supplying & fixing of 25mm thick expansion joint sheet including cost of all labour,material atc all complete as per the direction of the engineer-in-charge.Ground Floor 83 First Floor 84 Second Floor 85 Third Floor 86 50001694Supplying, fitting & fixing of Vetrifed Tile in floors of size 600mm x 600mm (colour / printed series)of approved make conforming to IS : 13755 laid on 20 mm thick cement mortar and filling joints with white cement of approved quality including cost of all materials, labour T &P etc required for the works all complete as per direction of Engineer -in- charge. (For new work only)Ground Floor 87 First Floor 88 Second Floor 89 Third Floor 90 50001814Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame. shutters and all fitting and fixtures.Ground Floor 91 First Floor 92 Second Floor 93 Third Floor 94 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor 95 First Floor 96 Second Floor 97 Third Floor 98 Forth Floor 99 50010542Providing, Fitting and Fixing of three track (122mmx 54mm) height below 1.5 Mtr.UPVC glazed sliding window Premium quality with frames and sashes shall be from white UPVC profile. All section of frame and sashes shall be reinforced with galvanized steel in single continuous length, holes about 8mm dia to be provided @ 300mm C/C outer side of lower sashes, window shall be such that glazing or deglazing on site possible without the need to remove the outer frame from the structure of the building. Glazing must be used 5mm thick reflective toughened glass with weather seal. Window frame will be fixed to the wall with 100mm long and minimum 8mm dia. fasteners and after fixing frame the gap in between the frame and wall should be filled with silicon sealant for inner frame sealing complete with all fixtures in all respect. UPVC Window make:-DUROPLAST / SIMTA ASTRIX / NCL VEKA, All GLASS work:- Saint-Gobain/AIS (ASAHI).Ground Floor 100 First Floor 101 Second Floor 102 Third Floor 103 50010554Providing, supplying and fixing of UPVC Glazed Fixed Louvered Ventilator of size 600 mm X600 mm made out of multi chambered UPVC of DUROPLAST / SIMTA ASTRIX / NCL VEKA having isolated drainage, holes about 8 mm dia. to be provided @ 300 mm C/C outer side of lower sashes and reinforced with Galvanized Iron profiles throughout the window with Fan(185mm)of USHA / CROMPTON/Havells/Anchor. The outer frame having an overall size of 39 mm x 39 mm x 2.2 mm thickness with reinforcement of 1.2 mm . Ventilator shall be provided with 4 mm Pin Head glass, standard hardware. Wall thickness of frame and Mullion shall be 2.4 mm, including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site complete for finished item of work with transportation and wastage.Ground Floor 104 First Floor 105 Second Floor 106 Third Floor 107 50010620Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY)Ground Floor 108 First Floor 109 Second Floor 110 Third Floor 111 Forth Floor 112 50010668Providing and Fixing of Factory made WPC Door Frame of size 125x65 provided with plug-in socket arrangement and joined together by screws. The finished door frame units to be of approved colour using high quality pigments complete in all respect as per specification. [NSWI] WPC Frame make:-Century/GreenGround Floor 113 First Floor 114 Second Floor 115 Third Floor 116 50010704Providing and Fixing of Single leaf solid WPC door shutter of 30 mm thick compacted with wood grain finished with 2 Nos SS Handles (150 mm), 2 Nos SS Tower Bolt (250mm x 10mm), 4 Nos. SS Butt Hinges (125mm x 8.5mm x 5.5mm ) with all necessary fittings Complete with approved colour . [NSWI]Make:- WPC Door(Century/Green), Hard ware fittings (Godrej).Ground Floor 117 First Floor 118 Second Floor 119 Third Floor 120 50010716Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing.Ground Floor 121 First Floor 122 Second Floor 123 Third Floor 124 Forth Floor 125 50010827Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia. of 2mm thick circular pipe with Balustrade of size 38mm x 38mm x 2mm @ 900mm C/C, stainless steel square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification and the entrance newel post will be 100mm dia. of 750mm height with top bulb, buffing, polishing etc. with cost, conveyance, labour, T and P etc. required to complete in all respect. [NSWI] Stainless steel Brand:- JINDAL/NIPPON STEEL.Ground Floor 126 First Floor 127 Second Floor 128 Third Floor 129 50010839Supplying, fitting and fixing of 110mm dia PVC rain water down pipe (min. 6kg/sqcm) (IS-4985) with necessary fittings and all complete. PVC Pipe Brand:-SUPREME/ORIPLAST/FINOLEX.Ground Floor 130 First Floor 131 Second Floor 132 Third Floor 133 Forth Floor 134 50011579Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC ROOF SLAB)Ground Floor 135 First Floor 136 Second Floor 137 Third Floor 138 Forth Floor 139 50011592Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC COLUMNS)Ground Floor 140 First Floor 141 Second Floor 142 Third Floor 143 Forth Floor 144 50011604Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC SILL BAND)Ground Floor 145 First Floor 146 Second Floor 147 Third Floor 148 50011616Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR COLUMN FOOTING)Ground Floor 149 50011628Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR LINTEL BEAM).Ground Floor 150 First Floor 151 Second Floor 152 Third Floor 153 Forth Floor 154 50011640Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR RCC CHHAJA & SHELVES).Ground Floor 155 First Floor 156 Second Floor 157 Third Floor 158 Forth Floor 159 50011652Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC STAIRCASE).Ground Floor 160 First Floor 161 Second Floor 162 Third Floor 163 50011664Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR TIE BEAM).Ground Floor 164 50011676Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR RCC FLOOR BEAMS).Ground Floor 165 First Floor 166 Second Floor 167 Third Floor 168 Forth Floor 169 50011688Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC FINS).Ground Floor 170 First Floor 171 Second Floor 172 Third Floor 173 50014362Supplying, fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.Ground Floor 174 50015685Supplying. fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete.Ground Floor 175 First Floor 176 Second Floor 177 Third Floor 178 50015997Priming one coat with any approved primer on new work to give an even shade including scaffolding and cleaning the surface before application etc.complete.(FOR INSIDE)Ground Floor 179 First Floor 180 Second Floor 181 Third Floor 182 Forth Floor 183 EPH 184 10000556Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200cfm/300psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of own rigs with its accessories,tools and plant and consumables etc for lowering of 200mm dia PVC pipes for housing fitted with socket and with or without well screen as per tenecessity for soft,medium,hard and boulder formation (PVC casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and with drawing after completion of the tube well).(Icluding both LABOUR FOR DRILLING 200MM DIA UPTO 30 MTR. & LABOUR FOR DRILLING 150MM DIA FROM 30 MTR TO 150 MTR including all.) CONSIDER FOR 150 MTR DEPTH.Ground Floor 185 10000564Lowering 200mm dia. PVC pipes with or without slotted pipes as per the necessity from ground level with fitting and fixing the same in a perfectly vertical position. This includes cutting, threading pipes/slotted pipes with providing and fixing of required jointing materials, tools and plant etc. complete and keeping the top of the casing pipe threaded including plugging tube wells so as to prevent entry of foreign materials from above. (FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG).Ground Floor 186 10000570Cleaning and developing 200mm dia. tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour .(FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG).Ground Floor 187 10000583Supplying and fixing of control panel board with all accessories. (UPTO 3HP SINGLE PHASE) Make: KSBGround Floor 188 10000588Supplying and fixing of HDPE Pipes 32/40 mm (High Density Polyethylene pipes having inner dia. 32mm and outer dia. 40mm) 6Kg/Sq. cm With IS specification.(32MM NOMINAL BORE SIZE). Make Finolex/Oriplast/Supreme.Ground Floor 189 10000594Supplying and fixing of PVC coated steel rope including cost of material, labour etc. complete. Make-Mahdev/AerolexGround Floor 190 10000596Supplying and fixing of Finolex/L&T/Cable 4 Sq. mm (3core copper wire flat cable with PVC insulation).Ground Floor 191 10000600Supplying and fixing of accessories like Nipple, Bore cover, MS clamp, Nut Bolt, Stainless steel nipple, Short piece, GI bend, Socket etc. complete.Ground Floor 192 10000602Installation charges pump set with all accessories including transportation etc.Ground Floor 193 10001184Supplying of 200mm inner dia. PVC casing pipe for deep bore well CD (deep well casing) type basing on IS-12818-2010, wall thick ness 13mm to 14.8mm with One end of the pipe is male-threaded whereas the other end is a female-threaded socket. Threads are either V-type or trapezoid-type, and protection caps are provided on the threads to protect the threads in transit. With pressure ratings ranging from 7.5 to 20 bar (PN). Make: ORIPLAST/SUPREME/FINOLEXGround Floor 194 10001190Supplying Submersible Pump Set with the cost of Motor of following model including cost of transportation charges.1.5HP, Single phase,32D,19 Stage (head 50-129m). Make: KSB(2C/21).Ground Floor 195 FUR 196 50010506Supplying and fixing of GODREJ MAKE MATTRESS MODEL NO- SWING(78x36x4) MATRESS (56101508SD02049). [NSWI]Ground Floor 197 50010508Supplying and fixing of GODREJ MAKE PILLOW MODEL NO-Neon Pillow16 24 1. [NSWI]Ground Floor 198 50015237Supply and Providing of Cot having(Inside to inside) dimensional length 6-6 (1975 MM) x Width 3(915MM)x Height 22 (560 MM)made of1.6MMthick M.S Tube of 41 MM O/D with Stiffeners(M.S.tube) of 25MM O/D x 1 MM thick. The Top shall be 19mm thick BWP ply with properly bolted to bed stiffeners with 9 nos. of counter shank bolts with lock nuts. The cot shall be painted with 1 coat wood (for ply part)/iron (M.S tube part)primer and 2 coats enamel paints with mosquito curtain stand etc. all complete. [NSWI] Make: MS materials(SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)), PLY(GREEN/CENTURY)(new revised rate)Ground Floor 199 INE 200 40000946Recessed wiring to Angle Holder Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havells/V guard/KEI) Make-switch /Angle holder-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 201 40000949Recessed wiring to Tube Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 202 40000952Recessed wiring to Calling Bell Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular bell push ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-bell push switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 203 40000955Recessed wiring to Bulk Head Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 204 40000958Recessed wiring to Television Point (Modular)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/TV socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK).Ground Floor 205 40000961Recessed wiring to Telephone Point (socket)with 2 pair 0.5sqmm telephone cable with 20 mm dia non metalic PVC flexible conduit with socket ISI marked MS Box including all accessories and connection.( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-s witch-Telephone socket -Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK).Ground Floor 206 40000964Recessed wiring to Portico Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . ( Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch /Ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 207 40000970Recessed wiring to Ceiling Fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 208 40000973Recessed wiring to Exhaust fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 209 40000976Recessed wiring to Security Light Point ( MODULAR)(1X36WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/HPL/KEI) Make-switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 210 40000979Recessed wiring to Security Light Point ( MODULAR) (4X24WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 15 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/HPL/KEI) Make-switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 211 40000982Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 212 40000985Point wiring for 5/ 6 amp socket outlet ( Separate) ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 213 40000988Point wiring for 15/16 amp socket outlet ( MODULAR) with 4.0sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 15/16 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor 214 40001000Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.2)(Make of PVC pipe-AKG/NORPACK)Ground Floor 215 40001003Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.3)(Make of PVC pipe-AKG/NORPACK)Ground Floor 216 40001012Recessed wiring to submain in 4 x 6 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 2.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.10)(Make of PVC pipe-AKG/NORPACK)Ground Floor 217 40001015Recessed wiring to submain in 4 x 10 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 4 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.11)(Make of PVC pipe-AKG/NORPACK)Ground Floor 218 40001036Supply and laying of 35 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI)Ground Floor 219 40001126providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18)Ground Floor 220 40001129Supplying and fixing of 6X4 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-National / Royalam)Ground Floor 221 40001132Supplying and fixing of 8X6 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-(National / Royalam)Ground Floor 222 40001135Supplying and fixing of 8X10 16/18 swg,2 deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5)(Make-(National / Royalam)Ground Floor 223 40001141Supplying and fixing of two modular GI Box 18 swg with Modular base & cover for 2 module (Sl. No- 1301,1421)(Make-switch/Socke t-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor 224 40001145Supplying and fixing of 4 modular GI Box 18 swg with Modular base & cover for 4 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor 225 40001151Supplying and fixing of 8 modular GI Box 18 swg with Modular base & cover for 8 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor 226 40001154Supplying and fixing of 12 modular GI Box 18 swg with Modular base & cover for 12 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor 227 40001163Supply and Fixing of 32 AMP 4P MCB-1NO 32AMP .415 VOLT CUTOUT -03 NOS WITH COPPER BUS BAR & INDICATOR ETC.including all accessories and connections. [Make-(a) MCB/MCCB- Legrand/L&T/ABB/SCHNIDER(b)- Voltmeter, Ammeter-AE/CAPPA (c) ALL OTHER ACCESSORIES ISI MARK]Ground Floor 228 40001172Supply of U-type fan hook(Make-TATA)Ground Floor 229 40001178Supply and fixing of 4 way mcb Box with 32 Amp TPN MCB & 12 nos 20 amp SPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required. ( Sl. No- 2.7.4, 2.5& 2.9)Make-MCB-(Legrand/L&T/ABB/SCHNIDER)Ground Floor 230 40001190Supplying and fixing of Call Bell/buzzer ISI marked suitable for DC/AC single phase 230 volts complete as required (CSR sl no-1.30)Ground Floor 231 40001193Blanking Plate(Make-Legrand /Wipro-NorthWest /Anchor-Panasonic/ havells)Ground Floor 232 40001218Supply and Fixing of 125 AMP. TPMCCB [35 KA] - 01 SET WITHOUT METER SPACE OUT GOING 100 AMP , 25 / 3 MM. COPPER BUS BAR - 04 NOS INSTRUMENTS 0 –100 AMP. AMMETER WITH SELECTOR SWITCH - 01 SET 100 / 5 AMP. CT - 01 SET 0 – 500 VOLT. VOLTMETER WITH SELECTOR SWITCH - 01 SET INDICATING LAMP WITH CONTROLLING SWITCH - 01 SET etc.including all accessories and connections as per instruction of Electrical Engineer-in- Charge. [Make-(a) MCB/MCCB- Legrand/L &T/ABB/SCHNIDER/ANCHOR-PANASONIC(b)- Voltmeter, Ammeter-AE/CAPPA (c) ALL OTHER ACCESSORIES ISI MARK]Ground Floor 233 40001234supply of Stepped type modular fan regulator.(Make-Regulator-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor 234 40001295Supply and fixing of 4 way mcb Box ( 4+12) with 63 amp 4P Isolator/ 4P MCB & 12 nos 20 amp SPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required. Make-MCB-(Legrand/L&T/ABB/SCHNIDER)Ground Floor 235 40001679Supply and fixing of surface mounted led 12 wt square/round portico light with powder coated finished in white housing 1with lamp , choke, connecting wire, and all accessories and connections (Make- CROMPTON/ PHILIPS/ WIPRO)Ground Floor 236 40001876Supply and fixing of 16 Amp top(for inverter installation) with all accessories and conncetion(Make-Legrand/wipro/Anchor-Panasonic)Ground Floor 237 40001879Recessed wiring in 1X1.5sqmm (For inverter)/DG wiring )FR PVC insulated single core multistrand copper conducter of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick as per direction of Engineer in charge(Make of wire Finolex/Anchor/Havells/V guard)(Make of PVC pipe-AKG/NORPACK)Ground Floor 238 40008124Supply & fixing of 400mm (16) wall mounted fan with complete accessories[brown/white].including hanging and connections [MAKE- USHA MODEL-MIST AIR DUOS/ CROMPTON MODEL-TROPEDO HI SPEED//HAVELLS/V-GURAD MODEL-PETAL WF 17/ANCHOR)Ground Floor 239 40008126Supply and fixing of 250 mm sweep air ventilating fan with Louvers (PVC BODY) fan with connecting wire and all accessories including fixing and connections . [MAKE- USHA MODEL-CRISP AIR VX/CROMPTON MODEL-VENTILUS/HAVELLS/ANCHOR)Ground Floor 240 40008158Supply and fixing of 1200 mm BLDC (ISI mark 5 star rated)(28wt with aluminium blade)ceiling fan (without remote) with connecting wire and all accessories including hanging and connections .- [MAKE- USHA MODEL-TECHNIX/ CROMPTON MODEL-ENERGIA GROOVE /V-GUARD /HAVELLS MODEL-EFFICIENCIA NEO/ANCHOR-PANASONIC MODEL-PENTA TURBO)Ground Floor 241 40008291Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia Heavy Duty TATA make including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required.(Minimum 1.5 mtr distance from building & 3 mtr distance from earthing to earthing)Ground Floor 242 40008393Supply and fixing of 9 WT. LED Bulb installred at angle holder/ batten holder.(Make- CROMPTON/ PHILIPS(MODEL NO-AceSaver 9W)/WIPRO(MODEL NO-N09001)Ground Floor 243 40008397Supply and fixing of 4 FT 20 W LED Tube light fitting with lamp including fixing and connections (Make- CROMPTON(MODEL NO-CCS-102- 20-65-SL-DP-NWH/ PHILIPS(MODEL NO-SLIMLINE NEXT 4/ WIPRO(MODEL NO-LL20-221-XXX-65NE3)Ground Floor 244 40008399Supply & fixing of 25 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories (Make- CROMPTON(MODEL NO-TRP-415-25-57-SL-LM-NBK)/ PHILIPS(MODEL NO-BRP029 LED25S 25W 2500LM)/ WIPRO)Ground Floor 245 40008401Supply & fixing of 45 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories (Make- CROMPTON(MODEL NO-TRP-417-45-57-SL-LM-NBK)/ PHILIPS(MODEL NO-BRP031 LED45S 45W 4500LM)/ WIPRO(MODEL NO-LR08-611-XXX-57-XX)Ground Floor 246 40008427Supply and fixing of Bulk Head fitting with 9 wt. LED Bulb including all accessories and connections . (Make- CROMPTON(MODEL NO-LBHP-10-CDL / PHILIPS(MODEL NO-WT202 LED10S 10W 1000LM LED LIGHT BULK HEAD/ WIPRO)Ground Floor 247 IPH 248 10000002Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 20mm nominal outer dia pipesGround Floor 249 10000004Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 25mm nominal outer dia pipesGround Floor 250 10000006Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 40mm nominal outer dia pipesGround Floor 251 10000008Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 50mm nominal outer dia pipesGround Floor 252 10000174Laying in trenches unplasticised PVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by heat application method including testing as per specification complete. (Earth work in trenches to be measured and paid for separately). (160mm dia rigid UPVC pipe Class- 3 (0.60 mpa)).Ground Floor 253 10000176Laying in trenches unplasticised PVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by heat application method including testing as per specification complete. (Earth work in trenches to be measured and paid for separately). (110mm dia rigid UPVC pipe Class- 3 (0.60 mpa)).Ground Floor 254 10000294Laying in trenches OD PVC pipes and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by non-heat application method including testing as per specification complete. 110mm dia OD P.V.C SWR double socket pipes (ISI TYPE-A),Analysis is done as per AR-2013,SL NO-2.3.2 .Ground Floor 255 10000296Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .SINGLE JUNCTION WITH DOOR 110 mm P.V.C SWR TYPE. according to AR-2013 SL NO-3.3.3(V)Ground Floor 256 10000298Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .110MM DIA PLAIN BEND P.V.C SWR TYPEGround Floor 257 10000300Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .110mm dia bend with door P.V.C SWR TYPEGround Floor 258 10000304Fixing 110mm size ‘P’ trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification.110 MM DIA P.V.C SWR P-TRAPGround Floor 259 10000306Fixing floor traps of the following nominal diameter of outlet of self cleaning design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per specification.110mm dia p.v.c Nahani trap without jally.Ground Floor 260 10000308Fixing floor traps of the following nominal diameter of outlet of self cleaning design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per specification.110mm dia GULLY Trap P.V.C SWR TYPEGround Floor 261 10000310Providing and fixing on wall face PVC SWR moulded fittings / accessories for PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .110 mm dia off set as per p.v.c swr type.Ground Floor 262 10000312Providing and fixing on wall face PVC SWR moulded fittings / accessories for PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion.110 mm dia cowel P.V.C SWR TYPE.Ground Floor 263 10000314Fixing water closet, squatting pan (Indian type W.C pan) conforming to IS 2556 : Part 3- 2004 duly embedded in cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per specification.Porcelin 23 inch LWC(ORISSA Pan)Ground Floor 264 10000318Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. ( With Seat and cover)Ground Floor 265 10000322Fixing wash basins with hole for pillar taps conforming to with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification.Porcelain Counter Top Basin Oval shape(550X430) with Pillar cock for basin (C.P Pillar cock with Swinging spout),PVC inlet connection pipe ,Chromium Plated brass waste ,PVC waste pipe 32mm Dia,Chromium Plated brass trap including all as per the direction of the E.I.C.Ground Floor 266 10000326Fixing bowl pattern urinal conforming to IS 2556 : Part 6-1996 including connecting the urinal of 380X580X350 mm sizes respectively with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification.Porcelam Flat back standmg Urinal (Medium)380 x 580 x 350 including all & As per the direction of the E.I.C.Ground Floor 267 10000332Providing and fixing Stainless Steel kitchen sink with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required.24X18X10 STEEL sink single bowl (parry ware) as per the direction of the E.I.C.Ground Floor 268 10000336Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.As per the direction of the E.I.C .(10 litre capacity - colour)Ground Floor 269 10000346Fixing of C.P Screw-down TWO WAY Bib Cocks (Taps) polished bright conforming to with CP flange and CP extension piece of the following nominal sizes as per specification complete As per the direction of the E.I.C . (Delux Head& high quality).(15mm diameter C.P Two way bib cock)Ground Floor 270 10001088Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc. all complete as per specification with 1:4 brick work in cement mortar (1:4) and 12mm thick cement plaster. For 250mm thick wall.Ground Floor 271 10001094Cutting holes in R.C.C floor and roofs up to 19cm thick for passing G.I/PVC pipes and fittings etc. and repairing the hole after insertion of pipes etc. with cement concrete (1:2:4) including finishing complete so as to make it leak proof. Details cost of 1 hole of average size 15cm X 15cm X 25cm.Ground Floor 272 10001096Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete, with cement concrete (1:3:6) and 12mm cement plaster (1:3) along with Cement punning.Ground Floor 273 10001124Providing and fixing of 25mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 25 mm dia. CPVC Full Way Valve / Ball Valve.Ground Floor 274 10001126Providing and fixing of 40mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 40 mm dia. CPVC Full Way Valve / Ball Valve.Ground Floor 275 10001128Providing and fixing of 50mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 50 mm dia. CPVC Full Way Valve / Ball Valve.Ground Floor 276 10001160Providing and fixing Rotational moulded polyethylene cylindrical vertical water storage tank 3layer wall conforming to IS : 12701--1996 including cutting holes through the tank and fixing, fittings CPVC tubes and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting up to a height of 5 metres above ground level and placing the tank to the required position etc. all complete as per specification. Make: SINTEX/SUPREME/ORIPLAST. Triple Layer Cylindrical Vertical water storage tanks.Ground Floor 277 10001162Extra over (item No 3.1.8 as per A.R 2013) for hoisting Rotational moulded polyethylene cylindrical vertical water storage tanks of the following size for every additional height of 5 metres or part there of installation on roof as per the requirement and site condition.Ground Floor 278 10001209Providing and fixing curved/Rectangular shaped urinal partition with 10mm thick frosted glass chrome finish size H:900XW:450mm with stainless Steel brackets including cutting holes in wall and making good the damages etc. complete as per specification. Make: JAQUAR (JSE-CHR-110UC450X/110US450X). Curved/Rectangular shaped urinal partition with 10mm thick frosted glass chrome finish.Ground Floor 279 10001466Supplying,fitting & fixing of 15mm dia C.P.angular stop cock with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor 280 10001468Supplying,fitting & fixing of 15mm dia C.P concealed stop cock with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor 281 10001470Supplying,fitting & fixing of CP Shower (Over Head) with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor 282 10001472Supplying,fitting & fixing of CP Arm for Over head Shower with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor 283 10001474Supplying,fitting & fixing of CP Health Foucet with 1.0 1 RM PVC Tube with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor 284 10001476Supplying,fitting & fixing of C.P.soap holder/disc. with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor 285 10001478Supplying,fitting & fixing of C.P. glass scif with glass with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor 286 10001480Supplying,fitting & fixing of CP. towel rail.(600x20)mm with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor 287 10001482Supplying,fitting & fixing of CP. towel ring. with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor 288 10001484Supplying,fitting & fixing of Bevelled Edge Mirror with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor 289 MIS-CVL-INSPECTION 290 50000001Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth.Ground Floor 291 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor 292 50000008Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. Ground Floor 293 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor 294 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor 295 50001303Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & PlinthGround Floor 296 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor 297 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor 298 MIS-CVL-OVERBURDEN 299 50001659Excavation for roadway in ordinary rock by mechanical means ( 80 HP Dozer) including cutting & pushing the earth to site of e mbankment upto a distance of 100 metres(avarage lead 50 mtr. including trimming bottom and side slopes in accordance with requirements of lines,graders and cross section as per clause 301 & S.r 3.4 of MoSRT&H Spection for road & bridge work.Ground Floor 300 MIS-CVL-PAVERROAD 301 50000001Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth.Ground Floor 302 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor 303 50001701Providing and laying 80 mm thick Factory made cement concrete interlocking Paver block of M40 grade made by block making machine with strong vibratory compaction and approved size and design/ shape laid in required colour and pattern over and including 50 mm thick compacted bed of coares sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer-In-Charge.Ground Floor 304 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor 305 MIS-CVL-RCCDRAIN 306 50000001Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth.Ground Floor 307 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor 308 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor 309 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor 310 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor 311 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor 312 MIS-CVL-SEPTICTANK 313 50000001Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth.Ground Floor 314 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor 315 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor 316 500000184 thick dry brick rammed khoa well watered and fully consolidated complete,including cost of all materials as per direction of Engineer-in-charge. Ground Floor 317 5000001925mm. thick A.S. Flooring with cement concrete 1:2:4 including punning using 12mm. size hard granite chips including cost of all materials T & P etc complete. Ground Floor 318 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor 319 50001303Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & PlinthGround Floor 320 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor 321 50001839Fly Ash brick masonary work in cement mortar 1:4 (1 cement : 4 sand) using fly ash bricks of 23cm X 11cm X 8cm having crushing strength not less than 35kg per sqcm with dimensional tolerance +/-2% including watering,curing and cost,conveyance,royality of all m aterials and cost of labour etc complete.As per the direction of the E.I.C.Ground Floor 322 50010360Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB)Ground Floor 323 50010420Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC CHHAJA and SHELVES)Ground Floor 324 50010446Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS)Ground Floor 325 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor 326 MIS-INE-FIREFIGHTI 327 40007924Providing , fixing of terrace boster pump of 450 lpm volute bronze impeller connected to a TEFC induction motor suitable for 410/440 volts, 3 phase , 50 cycles AC supply as per the details given below.Make:Wilo / Kiloskar Or Lubi.Ground Floor 328 40007936Supply, Installation, Testing and Commissioning 100mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti)Ground Floor 329 40007938Supply, Installation, Testing and Commissioning 80mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti)Ground Floor 330 40007944Providing and fixing of Non return valve 100mm nominal dia cast iron dual plate check valves of PN1.6 including nuts, bolts, 1.5mm thick compressed asbestos gasket including matching flanges .SANT / ZOLOTO / KARTAR.Ground Floor 331 40007952Providing and fixing of 100mm nominal dia C.I. Butterfly valves conforming to PN 1.6/13095 with nuts, bolts, washers, 3mm thick ins ertion rubber gasket and two matching flanges .SANT / ZOLOTO / KARTARGround Floor 332 40007960Supply, installation, testing and commissioning 100mm dia CI `Y strainer with bronze perforated sheet basket including rubber gasket, flanges, nuts, bolts and washers etc., complete.SANT / ZOLOTO / KARTARGround Floor 333 40007964Providing and fixing dial type pressure gauge with isolation cock and chrome plated copper pipe at hydrant station.Make - H-Guru.Dial diameter 100 mm calibration 0-15 kg/sp.cmGround Floor 334 40007968Providing and fixing electrically operated dual type pressure switches with threaded connection for a pressure vessel, complete suitable for 0-15 Kg/Sq.cm model IPS-200 .Make - Dandfos.Ground Floor 335 40007970Providing and fixing of 15mm brass ball valve with lever and screwed female ends.(20 kg/cm2)at all level and position .Zoloto/Kartar.Ground Floor 336 40007972Providing and fixing of 25mm brass ball valve with lever and screwed female ends.(20 kg/cm2)at all level and position .Zoloto/Kartar.Ground Floor 337 40007974Supplying and fixing approved make 25 mm dia automatic air release valve suitable for 20kg/sqcm working pressure with necessary fittings complete in all respect at all level and position .Zoloto/Kartar.Ground Floor 338 40007980Providing & fixing Two way fire brigade inlet Gunmetal collecting head with 63 mm dia instantaneous type inlet and 150 mm dia flanged outlet fire brigade connection to fire risers (I.S. 904-1965) complete with campanion flange as per table E nuts, bolts, gasket included cutting & welding at all level and position ..Fire shield / KARTARGround Floor 339 40007986Supply , Installation , testing and commissioning of control panel of 450lpm fire pump .Make -ASES/LUBI/GREEN POWER .Ground Floor 340 40007998Supply and laying of 3C X 6sqmm sqm copper cable Power cabling (XLPE) insulated and PVC sheathed, armoured, Aluminium Conductor of 1.1 KV grade on existing cable trays).(Finolex/Havells/Polycab)Ground Floor 341 40008008Providing and fixing SS landing valve conforming to IS -52290 with 63 mm dia. instantaneous female coupling on the outlet with PVC cap with chain, necessary companion flanges ( as per table E) nuts, bolts, washer and gasket complete as per specification. (ISI marked) .SAFE GUARD / KARTAR /Ground Floor 342 40008010Providing and fixing first aid fire hose reel drum wall mounting, swinging type fitted with 20mm dia. B129 30m long high pressure rubber hose type -II to IS. 5132 or nylone braieded polypropelene hose of approve make with 5 mm outlet S.S. nozzle with shut off valve (IS. 884-1969).(Make-SAFE GUARD / KARTAR / SWASTIK)Ground Floor 343 40008012Providing and fixing SS coupling 63 mm dia. 15m long rubberized EPDM lined hose including SS male and female instantaneous type coupling approved by fire authority.(Make-SAFE GUARD / KARTAR / SWASTIK)Ground Floor 344 40008014Providing and fixing standard short size SS branch pipe with SS nozzle 16 mm dia. outlet with standard instantaneous type 63 mm dia. coupling. (ISI marked) .(Make-SAFE GUARD / KARTAR / SWASTIK)Ground Floor 345 40008018Providing and fixing M.S. structural work fabricated from standard sections e.g. M.S. Rounds, angles, channels, GI clamps including cutting to size drilling, welding including insert plates or Hilti/ Wurth fastners of required specification in RCC structural/masonry.Ground Floor 346 40008020Providing and fixing fire hose cabinet fabricated from 16 gauge M.S. sheet with locking arrangement and hanging arrangement for accessories painted Fire Red with enameled paint Fire Hose written on front including suitable supports to place 900 mm above ground level properly anchored, approximately size 750x600x250 mm deep (to house two lengths of canvas hose with couplings, branch pipe with nozzle for external hydrants)(Make-Kartar/Newage)Ground Floor 347 40008024Providing and fixing Carbon-di-oxide fire extinguishers. Capacity 4.5 kg. ISI Marked.(Make -Fire shield/Kanex/Safex )Ground Floor 348 40008026Providing and fixing stored pressure portable (powder type) ABC - 6.0 kg fire extinguishers including all accessories as per latest IS with wall bracket and rawl plug(Make -Fire shield/Kanex/Safex .)Ground Floor 349 40008033Providing and fixing of 4kg clean agent type fire extinguishers including all accessories as per latest IS with wall bracket and rawl plug (Make -Fire shield/Kanex/Safex .)Ground Floor 350 40008057Supply ,Installation,testing & Commissioning of convensational 4 Zone Fire Alarm Panel . Make - Agni /ASES Or GST .Ground Floor 351 40008065Supply ,Installation,testing & Commissioning of convensational Manual Call Point . Make - Agni /ASES Or GST .Ground Floor 352 40008067Supply ,Installation,testing & Commissioning of convensational Hooter . Make - Agni /ASES Or GST .Ground Floor 353 40008073Supply and fixing of wall mounting type Auto glow signages of different type like, fire exit with one side arrow /do not use lift in case of fire/Emergency Exit/Staircase Indicating Arrow etc . Sizes :-300x150mm . type .(Make-Prolite autoglow)Ground Floor 354 40008099Supply, Installation, Testing and Commissioning 25mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti/ Wurth)Ground Floor 355 40008716Providing ,fixing , testing and commissioning of 2C X 1.5 sqmm copper armoured FR cable with PVC rigid counduit, shaddles, grips, screws etc complete.Make - PolycabGround Floor 356 MIS-INE-LIGHTINGPR 357 40002086Air-Terminal Supply, Installation, Testing & Commissioning of Early Streamer Emission (ESE-30))type Lightning Air Terminal. Supporting Mast The mounting pole used to support the lightning air terminal shall be minimum length of 05 Mtr. , non corrosive and made up of medium class GI / SS pipe of 1.5″ diameter having base plate at bottom for securely fixing the mast on roof top. The mounting pole and supports shall be securely fixed with the brackets and PVC insulated metallic guy wires to withstand the maximum wind velocity of that area. Protection Radius :- 48 Mtr Make :- ABB / STROMKING All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.Ground Floor 358 40002089Lightning Strike Counter Supply, Installation, Testing & Commissioning of non-electronic & non-resettable (Not require any external power supply) type lightning strike counter to count the lightning stroke having display with IP-67 enclosure including all accessories and connection..(6/7 digit) Make :- ABB / STROMKING All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. Engineer-in-Charge.Ground Floor 359 40002095Supply, Installation, Testing & Commissioning of maintenance free chemical earthing having enhancing chemical compound with 3 Mtr. Long copper bonded steel rod and suitable termination clamp including all accessories. Make :- ABB / STAR-X / UNIVERSAL All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.Ground Floor 360 40002098Supply, connection &Testing of sub earthing with 16 Sq.mm single core multi stranded copper flexible wire from surge protection device (SPD) panel to earth electrode & Main panel board to SPD panel including all accessories, cable socketing and connections. Make :- FINOLEX / ANCHOR / HAVELLS All the work should be carried out as per the specified specifications and instruction of the Engineer-in-ChargeGround Floor 361 40002101Supply, Installation, Testing & Commissioning of indoor type wall mounted Surge protection device (SPD) panel made of 2 mm thick CRCA sheet, dust and vermin proof duly powder coated having the following arrangement & complete factory wired by 16 Sq.mm single core multi stranded copper flexible wire. [A] Type 1+2 AC Surge Protection Device (SPD) (TP+N) (50 KA) - 01 Set [B] 63 Amp. HRC fuse with link – 03 Nos [C] 100 Amp. 4 pole stud connector – 01 No Make of SPD & HRC Fuse :- HAVELLS / L&T / LEGRAND Make of Wire :- FINOLEX / ANCHOR / HAVELLS All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.Ground Floor 362 40002720Supply and laying of 70sqmm single core FR PVC insulated unseathed copper conductor for voltage grade 1100 volt as per IS-694 in sur face/underground as required(sl no-5.5.2)(Make-KEI/FINOLEX/HAVELLS)Ground Floor 363 a) APPROVED MAKE /BRAND FOR CEMENT : ULTRATECH, NUVOCO, ACC, JSW (PSC),RAMCO(PSC),DALMIA(PSC),SAGAR(PSC) 364 APPROVED MAKE / BRANDS ARE TO BE UTILISED STRICTLY DURING EXECUTION OF ABOVE RELATED ITEMS OF WORK 365 CESS

Key Value

Document Fees
INR 11800 /-
EMD
INR 519000.0 /-
Tender Value
INR 5.18 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail