| 1 | Dismantling of brick tiles or terracing tiles single layer on roofincludingmud phuska also taking down existing APP membrane & disposal of retrieved material upto a distance n.exc 100m where directed, complete all as specified & directed by Engr-in-charge. |
| 2 | M&L for levelling course for roof slab, Type B0, 1:2:4 (12.5 mm graded aggregate) using waterproofing compound (SBR) for maintaining proper roof slope and finishing cement concrete surface even and smooth without using extra (Minimum thickness of concrete should not be less than 50mm at any point) complete all as specified & directed by Engr-in-charge.Note : Waterproofing compound should be measured and paid separately. |
| 3 | OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index not less than 106 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength >= 2 N/mm2 (ASTM D4541), elongation 350 to 400% as per ASTM D412 and crack bridging ability upto 2mm.(a) After proper surface preparation, Apply one coat of Primer for PU coatingas per manufacturers specification.(b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalentby brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c ) Apply 2nd & 3rd coat ofShaliUrethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller. Make : Fosroc/Sika/Choksey/Bostik/STP/ Asian Paints/Berger PaintsNote : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicatorapproved by GE.(iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years. |
| 4 | Supply of SBR waterproofing compound @ 2% ofper kg cement used complete all as specified & directed by Engr-in-charge.Make : Fosroc/Sika/Choksey/Bostik/STP/Asian Paints/Berger Paints |
| 5 | M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etcincluding demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles.complete all as specified and directed by Engineer - in -Charge. |
| 6 | M&L 15mm thick, rendering in cement mortar CM 1:4 to brick/concrete wall surfaces finished even & smooth without using extra cement complete all as specifiedand directed by Engr-in-Charge.Note : Work to be carried out upto 10 mtr height. |
| 7 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in CM 1:6 in finished even and smooth without using extra cement as external plaster on walls complete all as specified & directed by Engr-in-charge. |
| 8 | M&L 5 mm thick cement plaster in cement mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement complete all as specified & directed by Engr-in-charge. |
| 9 | Prepration of New external plastered wall surface and applying complete all as specified complete all as specified and directed by Engineer-in-charge of the following :-(a) Applying 1mm thick wall care puttyon wall surface and smoothening the surface prepatory to paint.(b) Applying 02 coats of exterior emulsion paint (light shade) with highlighter of any approved shade,@ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion complete all as specified & directed by Engr-in-charge. |
| 10 | M&L two coat of white wash on new plastered surfaces of ceiling including preparation of surfaces complete all as specified anddirected by Engr-in-Charge. |
| 11 | Taking up or down GI steel water tubing 15mm bore and connections including fittings from floor/walls/ceiling complete all as specified & directed by Engr-in-charge. |
| 12 | Taking up or down GI Steel water tubing 20mm bore and connections including fittings from floor/walls/centrings complete all as specified & directed by Engr-in-charge. |
| 13 | Taking up or down GI Steel water tubing 25mm bore and connections including fittings from floor/walls/centrings complete all as specified & directed by Engr-in-charge. |
| 14 | S & F Galvanised steel water tubing 15 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good complete all as specified & directed by Engr-in-charge. |
| 15 | S & F Galvanised steel water tubing 20 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good complete all as specified & directed by Engr-in-charge. |
| 16 | S & F Galvanised steel water tubing 25 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good complete all as specified & directed by Engr-in-charge. |
| 17 | Suppy and fix for pipe supporting clamping - single pipe of dia 15 mm (1/2\") down take pipe line fixing done with Clamping System consists of Mono Bracket, U Bolt Rubber sleve mounted sustem running vertically with wall distance 75 mm (3\"):-Pipe support Clamping Made of :-1. Mono Bracket for 15 mm (1/2\")piep having wall distance 75 mm (3\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn(HROP D) Steel (IS 1079):Material size 48 mm x 3mm with ribs and notch are Hot Dop Galvanised + Zn Al Flake Coated havingSalt Spray Test (Test Method- ASTM B-117-2019) result 2000 hrs.2.U Bolt rubber sleeve mounted are made of low carbon mild steel with Rod dia meter 7 mm approx : Zn Al Flake coated with noise abosring semi transparent ribbed silicon rubber slleve ; with Hex flange Nut BSQ 5/16 x18 x8 13 with serration set - Zn Al Flake coated.Hot dip Galvanising : as per IS 2629 (1985) -610 gms/32(>85 microns).Material Grade : IS 1079 used as per MTC confirms to EN 1020 3.1.Material Qualaity : for one unit :-(a) Mono Bracket for 15 mm (1/2\") pipe, wall distance 75 mm (3\") - 01 Nos,(b) U Bolt Rubber sleevemounted for 15 mm (1/2\") GI/UPVC/CPVC Pipe Dia-1 Nos. (c) Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\") - 02 Nos.Fixing Details : Pipe support clamping unit to be fixed at everymetre distance in theduct as complete all as specified and directed by Engineer in Charge |
| 18 | Suppy and fix for pipe supporting clamping - single pipe of dia 20 mm (3/4\") down take pipe line fixing done with Clamping System consists of Mono Bracket, U Bolt Rubber sleve mounted sustem running vertically with wall distance 75 mm (3\"):-Pipe support Clamping Made of :-1. Mono Bracket for 20 mm (3/4\")piep having wall distance 75 mm (3\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn(HROP D) Steel (IS 1079):Material size 48 mm x 3mm with ribs and notch are Hot Dop Galvanised + Zn Al Flake Coated havingSalt Spray Test (Test Method- ASTM B-117-2019) result 2000 hrs.2.U Bolt rubber sleeve mounted are made of low carbon mild steel with Rod diameter7 mm approx : ZN Al Flake coated with noise abosring semi transparent ribbed silicon rubber slleve ; with Hex flange Nut BSQ 5/16 x18 x8 13 with serration set - Zn Al Flake coated.Hotdip Galvanising : as per IS 2629 (1985) -610 gms/32(>85 microns).Material Grade : IS 1079 used as per MTC confirms to EN 1020 3.1.Material Qualaity : for one unit :-(a) Mono Bracket for 20mm (3/\") pipe, wall distance 75 mm (3\") - 01 Nos,(b) UBol Rubber sleevemounted for 20 mm (3/4\") GI/UPVC/CPVC Pipe Dia-1 Nos. (c) Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\") - 02 Nos.Fixing Details : Pipe support clamping unit to be fixed at everymetre distance in theduct as complete all as specified and directed by Engineer in Charge |
| 19 | Suppy and fix for pipe supporting clamping - single pipe of dia 25 mm (1\") down take pipe line fixing done with Clamping System consists of Mono Bracket, U Bolt Rubber sleve mounted sustem running vertically with wall distance 75 mm (3\"):-Pipe support Clamping Made of :-1. Mono Bracket for 25 mm (1\")piep having wall distance 75 mm (3\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn(HROP D) Steel (IS 1079):Material size 48 mm x 3mm with ribs and notch are Hot Dop Galvanised + Zn Al Flake Coated havingSalt Spray Test (Test Method- ASTM B-117-2019) result 2000 hrs.2.U Bolt rubber sleeve mounted are made of low carbon mild steel with Rod dia meter 7 mm approx : Zn Al Flake coated with noise abosring semi transparent ribbed silicon rubber slleve ; with Hex flange Nut BSQ 5/16 x18 x8 13 with serration set - Zn Al Flake coated.Hot dip Galvanising : as per IS 2629 (1985) -610 gms/32(>85 microns).Material Grade : IS 1079 used as per MTC confirms to EN 1020 3.1.Material Qualaity : for one unit :-(a) Mono Bracket for 25 mm (1\") pipe, wall distance 75 mm (3\") - 01 Nos,(b) U Bolt Rubber sleevemounted for 25 mm (1\") GI/UPVC/CPVC Pipe Dia-1 Nos. (c) Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\") - 02 Nos.Fixing Details : Pipe support clamping unit to be fixed at everymetre distance in theduct as complete all as specified and directed by Engineer in Charge |
| 20 | Dismantling water tanks any type exc. 250 ltr but nexc 500 ltr complete all as specified & directed by Engr-in-charge. |
| 21 | Dismantling water tanks any type exc. 500 ltr but nexc 1000 ltr complete all as specified & directed by Engr-in-charge. |
| 22 | Fixing only 500 Litre capacity Rotational moulded polyethylene water storage tanks Triple layered White coloured (cylindrical, vertical with closed top) , hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc.completeall as specified and directed by Engineer-in-Charge. |
| 23 | Fixing only 1000 Litre capacity Rotational moulded polyethylene water storage tanks Triple layered White coloured (cylindrical, vertical with closed top) , hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc.complete all as specified and directed by Engineer-in-Charge. |
| 24 | S&F25 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe,complete all as specified & directed by Engr-in-charge. |
| 25 | Dismantling cast iron work of any description complete all as specified and directed by Engineer-in-Charge. |
| 26 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles, tankconforming to Fe-290 Gde-E-165 complete all as specified & directed by Engr-in-charge. |
| 27 | M&L two coat of synthetic enamel paint on old painted surfaces of steel and iron work over 10 cm width or girth including preparation complete all as specified & directed by Engr-in-charge. |
| 28 | M&L, two coats of synthetic enamel paint over a coat of red oxideon steel surface over 10 cm width or girth, not otherwise described including preparation of new surface complete all as specified & directed by Engr-in-charge. |
| 29 | S&F 110mm bore PVC (SWR) pipessingle socketed in any length with rubber ring joints fixed to wall with PVC holding clamps/laid into trenches and includging Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes,set in cement mortar including PCC haunching and bedding, complete all as specified & directed by Engr-in-charge. |
| 30 | S&F 110mm bore PVC (SWR) bend/Tee, any radius with access door complete all as specified & directed by Engr-in-charge. |
| 31 | S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof etccomplete all as specified and directed by Engineer - in -Charge. |
| 32 | Suppy & fix for pipe supporting clamping - single pipe of PVC dia 110 mm (4\")down take pipe fixing done with clamping system consist of Profile bracket& continous slottted C Channle, U Blot rubber sleeve mounted system running vertically with wall distacne 75 mm (3\") :-Pipe Support Claping made of:- (a) Profile bracket having wall distance 75 mm (3\")made of Low Carbon Rol Gauge Corrected Galvanised , ZU Al Flake coatedhaving salt spray (TEst Method - ASTM B-117-2019) result 2000 hrs with SS 304 Hex Flange Bolt with serration 5/16 x 3/4 (A/F 13 mm)as per DIN 6921 and SS 304 Hex FlangeNut BSW 5/196 x 18 x 18 x 1.3 wieth serratio as per DIN 6923.(b) Continuous slotted \"C\" channelw with ribs to be used of size 250 mm (10\") made of Low CArbon Hot Roll Gauge corrected Oil pickled and Drawn (HROP D) Steel(IS 1079) are hot dip Galvanised, Zn Al Flake Coated with material thickness of 3 mm.U Bolt rubber sleeve mounted are made oflow Carbon mild steel with Rod diameter 7 mm approx; Zn Al Flake coated withnoise absorbing semi tranparent ribbed silicon rubber sleeve: with Hex Flange Nut BSQ 5/16 x 18x18x 13 with serration set as per DIN - 6923 Zn Al Flage coated.Hot dip Galvanising : as per IS 2629 (1985) -610 gm/m2(>85microns).Used as per MTC confimrs to EN 10204 3.1.One unit : 1. Profile bracket wall distance 75 mm (3\")- 02 Nos 2. Continuous slottted C chanbnel of size 250 mm (10\") -01 Nos.3. U bolt runner sleeve mountedfor 75 mm (3\") PVC pipe dia -01 No and Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\") - 0 Nos .Fixing details : Pipe supportc,amping unit to be fizedat every 1-2 meter distance in the duct complete all as specified and directed by Engineer - in -Charge. |
| 33 | S&F in repair 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified & directed by Engr-in-charge. |
| 34 | Disconnecting existing tanks of capacity exceeding 250 litres & not exceeding 500 litres etc, setting aside (or loweringif required)for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.complete all as specified and directed by Engineer in Charge |
| 35 | Disconnecting existing tanks of capacity exceeding 500 litres & not exceeding 1000 litres etc, settingaside (or loweringif required)for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.complete all as specified and directed by Engineer in Charge |
| 36 | Demolition of brickwork or stone/ boulder masonry, but built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & directed by Engr-in-charge. |
| 37 | Dismantling Asbestos cement/metal(corrugated, semicorrugated, etc.) sheets including ridge in roof coverings complete all as specified & directed by Engr-in-charge. |
| 38 | Dismantling unframed timber scantlings 40 sq. cm and over in section, in fillets, rails, posts, rafters, purlins, etc. in any position of any description not otherwise provided for and removing to stores complete all as specified & directed by Engr-in-charge. |
| 39 | Dismantling wrought iron or mild steel work of any description not otherwise provided for removing to stores complete all as specified & directed by Engr-in-charge. |
| 40 | Dismantling wall and ceiling boards (fibre, pulp, AC insulation, etc) or insulationboards/slabs/ blankets, any thickness, including cover fillets & snap grid and any description complete all as specified & directed by Engr-in-charge. |
| 41 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified & directed by Engr-in-charge. |
| 42 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St.-240 complete all as specified and as directed by Engr-in-Charge. |
| 43 | Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooksand hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing (Fe-410- W(Gde-E-250) qualitycomplete including taking out old one complete all as specified & directed by Engr-in-charge. |
| 44 | S&F in repairs Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, grade-Fe-410- W(Gde-E-250) quality-B complete all as specified & directed by Engr-in-charge. |
| 45 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed by Engr-in-charge. |
| 46 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified & directed by Engr-in-charge. |
| 47 | S&F 0.63mm thck plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275complete all as specified & directed by Engr-in-charge. |
| 48 | Taking down internal/external cement plaster on brick or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc. complete all as specified & directed by Engr-in-charge. |
| 49 | M&L for brick work with fly ash bricks, straight or curvedon plan, exc 6m mean radius built in CM 1:4 complete all as specified & directed by Engr-in-charge. |
| 50 | Material & Labour for preparation of newly plastered surfaces of any description and applying Two or more coats of 100% Premium exterior weatherproof acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces and 1.5mm to 2.5mm thick waterproof putty complete all as specified & directed by Engr-in-charge. |
| 51 | M&L for applying two coat interior Acrylic emulsion with 1st quality acrylic emulsion (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification over wall care putty of 2 mm thick over newly plastered surface to prepare the surface even and smooth complete all as specified and directed by Engr in Charge |
| 52 | M&L two coats of interior acrylic emulsion over old decorated surfaces of wall after complete removal of existing treatment includingpreparation of surface including priming coat as per manufacturer instructions and wall care putty 1.5mm to 2.5mm thick complete using roller complete all as specified and as directed by Engr-in-Charge |
| 53 | M & L preparation of old plastered surfaces ofwalls and applying finishing walls with Acrylic Smooth exterior emulsion (weather coat) paint of required shade, two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm and 1.50-2.50mm waterproof putty complete all as specified & directed by Engr-in-charge. |
| 54 | S&F Gl frame work for snap grid/seamless ceiling of size 605x605mm comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equalflanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified & directed by Engr-in-charge. |
| 55 | S&F 8mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified & directed by Engr-in-charge. |
| 56 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified & directed by Engr-in-charge. |
| 57 | S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified & directed by Engr-in-charge. |