Tender For Provision Of Training Sheds And Pt Sheds At Brc Danapur.; 2 Item No 01 :Design and Construction of Training Shed (432.00 Sqm of shed & 11.20 Sqm for toilet) for agniveers including internal water supply and internal electric supply with permanent specificationof 5.50 mtr Ceiling height as per Pre Engineered Building and all as specified Built with Permanent specification with RCC framed const having M-25 grade concrete,zonal specfication completeTotal Plinth area for 432.00 x 4 = 1728.00 Sqm, 04 Trg shed 3 Item No 02 : Design and Construction of PT Shed (432.00 Sqm of shed) for agniveers including inetrnal water supply and internal electric supply with permanent specificationof 5.50 mtr Ceiling height as per Pre Engineered Building and all as specifiedBuilt with Permanent specification with RCC framed const having M-25 grade concrete,zonal specfication complete.Toilet blockWC4.00 x 2 = 8.00WHB 4.00 x 1 =4.00Urinal 6.00 x 1=6.00Total floor area 18.00Add PACF 180% 32.40Total Plinth area50.40 Sqm 4 Sch A Part-II(External Electric Supply)Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule A Part-II against the lump sum price inserted by the MES. 5 Sch A Part-III(External Water Supply)Lump sum price worked out by the contractor for (External Water Supply) as listed in Schedule A Part-III against the lump sum price inserted by the MES. 6 Sch A Part-IV(Road, Path Curvert)Lump sum price worked out by the contractor for (Road, Path Curvert)as listed in Schedule A Part-IV against the lump sum price inserted by the MES. 7 Sch A Part-V (Sewage Disposal)Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule A Part-V against the lump sum price inserted by the MES. 8 Sch A Part-VI(Area Drainage)Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule A Part-VI against the lump sum price inserted by the MES. 9 Sch A Part-VII (Site Clearance)Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule A Part-I against the lump sum price inserted by the MES. 10 Note for Srl No 2 to 9The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 9by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule 11 Schedule A Part-VIII (Miscellaneous items of works) 12 External Electric Supple 13 Item No 03 : Supply ,fabrication, installation and testing of LT out door type factory made CPRI Approved ,feeder piller box of size 0.75 x 0.75 mtr made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5mm vertical legs frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed. 14 Incoming (a)MCB,415V, 4 pole, C series rating 63 Amps including all fixing accessories with both ends spreader links-01 No. (b)Digital voltmeter of range (0-500) volts, flush mounting type of size 96mm x 96mm (4”x4”) square dial with selector switch – 01 No.(c)Digital Ammeter of range (0-250) Amps, flush mounting type of size 96mm x 96mm (4”x4”) square dial with selector switch – 01 No.(d)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three). 15 Outgoing 16 (a)MCB, 415V, 4 pole, C series rating 40 Amps including all fixing accessories with both ends spreader links-02 No. 17 (b ) Aluminium busbar of 125 Amps current carrying capacity with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 nos. 18 (c)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. 19 Item No 04 : Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified. 20 Water Cooler 21 Item No 05 : Supply and installed water cooler, Electric driven,(single phase 230 volts) having approx storage capacity of 120 Litres and nominal cooling capacity of 60 Litres per hour complete all as specified. 22 Item No 06 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified. 23 Sewage Disposal 24 Item No 07 : RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls, Base slab, Baffle walls and roof slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 25 users conventional type. 25 Item No 08 : Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3 M dia X 3.0 M effective depth. 26 External Water Supply 27 Item No 09 : M & L for Construction of brick masonry valves pits, of the following internal dimension complete with 3015 mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC work complete. 28 (a) 600mm x 600mm x 600mm