Tender For Addn/ Altn To Airmen Mess At Af Stn Dinjan Under Ge (Af) Mohanbari; 1 Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and directed. 2 Demolition of RCC of any descrition and in any position not other wise specially provided for complete all as specified and directed. 3 Surface Dressingnot exceeding 30 cm deep and averaging 15 cm deep and getting outin soft / loose soil complete all as specified and directed. 4 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5 m depth insoft /loose soil etc complete all as specified and directed. 5 Excavation in trenches not exceeding 1.5m wide and not exceeding 3.00m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5 m depth insoft /loose soil etc complete all as specified and directed. 6 Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. 7 Removing excavated material exc 1.50 KM & n.exc 5 KM and depositing where directed at a level n.exc 1.5 M above from starting point complete all as specified and directed. 8 M&L for aggregate for loose Filling Broken stone builders gauge 40mm to 80mm complete all as specified and directed. 9 M&L for Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. 10 M&L for RCC (design mix) M-25using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed 11 M&L for RCC (design mix) M-25 using 20 mm graded stone aggregatesas in columns, pillars, piers, posts and struts and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. 12 M&L for RCC(design mix) M-25 using 20 mm graded stone aggregatesas in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately 13 M&L for RCC (design mix) M-25 using 20 mm graded stone aggregatesas in slab supported on wall, beam and column in floors, roofs, landings, balconies, canopies and inshelves and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. 14 Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter complete all as specified and directed. 15 Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs complete all as specified and directed. 16 Use and waste of Formwork to sides of pillars, posts, struts, piers, columns complete all as specified and directed. 17 Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, chazza and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. 18 M&L for Treating with Anti - Termite Treatment to the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified and directed. 19 M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area 20 M&L for Treating Anti - Termite Treatment the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. 21 M&L for Treating Anti - Termite Treatment the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. 22 M&L for Treating Anti - Termite Treatment the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. 23 M&L for Mild SteelTMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 24 M&L for Mild SteelTMT bar 6 to 8 mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 25 M&L for Brick work using old size bricks with sub class B bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. 26 M&L for rendering on fair faces of brick workor concrete surfaceof wall 15 mm thick in cement mortar 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed. 27 M&L for rendering 15mm thick in two layers (10 mm thick in cement mortar 1:6 and 5 mm thick in cement mortar 1:4 on external surface) on fair faces of brick work or concrete surfaces of wall and finished even and fair complete all as specified and directed. 28 M&L for rendering 5 mm thick in cement mortar 1:4 on RCC ceiling surface complete all as specified and directed . 29 M&L for applying two or more coats on new work for1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification.incl. priming plastered and other surfaces with alkaliresistant priming paint complete all as specified and directed. 30 M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqmover new surfaces, (including Camouflage pattern) complete all as specified and directed. 31 S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Roof/valley gutter/ cladding to wall, fixed with self tapping screws as specified.all joints to be sealed by silicone sealant complete all as specified and directed. 32 S&F for Plain, black, mild steel sheeting in ridges 0.63mm, hips valley gutters, drip and straight flashing (length and girth as fixed) complete all as specified and directed. 33 M&L for Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc Fe 410-W (Gde E-250) quality B complete all as specified and directed. 34 M&L for structural steel work Fe-410-W(Gde-E-250) quality-B as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. 35 M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end tobe fillted with washers and one hexagonal or square nut , exc 22.5cm and n exc 30cm long dia of shank 16 to 20mm complete all as specified and directed. 36 S&F for PVC (SWR) pipes single socketed 110mm dia in any length with rubber ring joints fixed to walls complete all as specified and directed. 37 S&F for 110mm dia PVC (SWR) bends any radius complete all as specified and directed. 38 M&L for Preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed. 39 M&L for 2nd class softwood clean sawn boards or planks, 30mm Thick, width n. exc 25 cm complete all as specified and directed. 40 M&L for preparation of new wood surfaces and applying two coats of sythetic enamel paint over a coat of wood primer complete all as specified and directed. 41 M&L for hard core using stone aggregate of size 63mm of basalt/ traps complete all as specified and directed 42 M&L for PCC 1:4:8Type D2 using 40mm graded stone aggregate as in sub base of the floor of 100mm thick complete all as specified and directed. 43 M&L for PCC 1:2:4 Type B1using 20mm graded stone aggregateinfloor of 25mm thick complete all as specified and directed 44 M&L for light shade Vitrified ceramic tiles 10mm thick (square/rectangular) polished ,area of each tilesexc 0.36 sqm but n exc 0.46 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour with 15mm thick screed bed (1:4) complete all as specified and directed. 45 M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in skirting/dado etc. over and including 10 mm thick plaster in cement and sand mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and directed. 46 M&L for machine cut kota stone slab flooring 20-25mm thickin riser of steps,skirting,dado and pillar laid over 10mm thick cement screed base1:4 laid and jointed with grey cement to match the shade of the slab including rubbing and polishing complete all as specified and directed. 47 M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.including 20mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed. 48 M&L for Cement concretetype B-2, 1:2:4 (40mm graded stone aggregate) 75mm thick for surafce finish complete all as specified and directed. 49 M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with gray cement and pigments including 20mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as dierected. 50 S&F for factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 42x50 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified and directed. 51 S&F for factory made uPVC white colour Casement door with top hung ventilator with 3D and SS friction (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 + 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed.Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 52 S&F for 5.00mm thick figured glass pin head tyhpe and glazing with oil putty in squares n.exc 0.50 sqm each complete all as specified and directed. 53 S&F for Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. 54 S&F for 150 mm extruded aluminium alloy handles, fabricated type complete all as specified and directed. 55 S&F for Aluminium anodised barrel tower bolt of extruded section 150mm long complete all as specified and directed. 56 S&F for 100 mm long butt hinges extruded aluminium alloy with galvanisedmild steel hinge pin anodised type B-21 complete all as specified and directed. 57 S&F for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed. 58 S&F for factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 59 S&F for unanoidised snap grid frame work of size of grid 605x605mm for false ceiling complete all as specified and directed. 60 M&L for hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expension hold fasterners 12.5mm dia, 40mm long complete all as specified and directed. 61 S&F for Non asbestos fibre cement 4mm thick building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. 62 S&F for Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc,fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for following bore of pipes. 63 20mm dia bore 64 25mm dia bore 65 S&Ffor Vitreous china counter type wash basin, white, flat back, size 630 mm x 450 mm fixed on and including cast iron cantilever bracketand including fixing of tap, waste fitting and union complete all as specified and directed. 66 S&F for 15 mm dia bore pillar taps fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or “cold’ with long screwed shank and flynuts, screwed for iron pipe and fixed complete all as specified and directed. 67 S&F for 15mm bore brass chromium plated stop cock fancy type long body with CP brass cup and screwed down to GI pipe complete all as specified and directed. 68 S&F for PVC connection 15 mm size with PTMT nuts of length 450 mm of approved quality complete all as specified and directed. 69 S&F for Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms)complete all as specified and directed. 70 S&F for PVC (SWR) floor trap of diameter of outlet 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed. 71 M&L for point wiring with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor(FRLS) 1100 Volts grade cable (red colour cable to be used for Phase connection and black colour cable to be used for neutral connection)including PVCconduit with all accessories including 1.5 sqmm copper multistrand conductor FRLS 1100 Volts grade unsheathed PVC insulated (green colour) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box made out of MS sheet 1.2 mm thick for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. 72 Light/Fan/Exhaust fan/Bell point 73 5 amp socket on same boared 74 5 Amp switch socket on Independent Board. 75 All as per item No 69 here in before but 4.0Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 5 pin 6/16 Amp switch socket combination on independent board complete all as specified and directed. 76 S&F for socket only 3 pin, 5 Amps flush type 230/240 V complete all as specified and directed. 77 S&F for switch socket combination 2 in 1, 5/6 Amps flush type230/240 V complete all as specified and directed. 78 S&F forswitch socket combination 3 pin, 15/16 Amps flush type 230/240 V complete all as specified and directed. 79 S&F for ceiling rose 3 phase/PVC/polycarbonate,isolated body,surface type with ISI marked complete all as specified and directed. 80 S&F for switch piano flush type 5/6 amps , 240 volt single pole one way complete all as specified and directed. 81 S&F for Step type electronic fan regulator flush type230 volt 5 speed control and connecting up and fix position complete all as specified and directed. 82 S&F for ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. 83 S&F for wall decorative ultra slim LED 18/20 Watt, 230 volts, 50 Hz, 4 feet, lighting fixture with extruded polycarbonate lighting fixture, environmental friendly, energy efficient ready to use pack including lamp complete all as specified and directed. 84 S&F for recessed mounted 36 Watt (clear white) LED panel light2x2 feet, ultra slim design, 230 volts, 50 Hz with CRCA sheet housing precoated white colour and high quality diffuser for uniform light and high efficiency with separate replaceable electronic driver including lamp complete all as specified and directed. 85 S&F for building security light LED type of minimum 3000/3500 Lumens (30/35watts) pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twisted copper conductor cable of suitable size including bracket made of 32mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and directed. 86 S&F for factory made sheet metal enclosure for DBs double door, SPN, 230 volt,12 Way, IP-42 protection with bus bar, neutral link, earth link complete all as specified and directed. 87 S&F for 240V, 10KA C curve miniature circuit breaker (MCB) SP 10 to 32 Amp current carrying capacity complete with connection testing complete all as specified and directed. 88 S&F for 240V, 10KA C curve miniature circuit breaker (MCB) SPN 63 Amp current carrying capacity complete with connection testing complete all as specified and directed. 89 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified and directed. 90 S&F for GI Pipe of 25 mm dia light grade for cable protection pipe complete all as specified and directed. 91 Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm spread any type of soil complete all as specified and directed. 92 Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and directed. 93 M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as specified and directed.Note: Punned thickness of sand shall be measured & paid. 94 M&L for well burnt sub class B bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick including taking out old complete all as specified and directed. 95 M&L for Earthing complete with GI plate electrode 600x600x6.3mm thick, buried directly and preferably vertically in ground(earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with Galvanize earth wire 4 mm diaby means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways,20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion. 96 Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5TR complete all as specified and directed. 97 M&L for sub main wiring withtwo run of 4 Sqmm PVC unsheathed, copper conductor cable, 1100 Volt,and onerun of copper earth wire 4.0 Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type complete all as specified and directed. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduictshall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. 98 S & F for sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete including one MCB, SPN, 20 Amps, 240 volts, 10 KA complete all as specified and directed. 99 S&F forVoltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4KVA complete all as specified and directed. 100 Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.