| 1 | Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor(iv) 12mm |
| 2 | Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floorGlossy/Matt/Suede excluding surface texture or metallic lustre.(i) Thickness of laminate 1.5mm |
| 3 | Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. |
| 4 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface : With super gloss (hi-gloss) -(iii) One coat (with any shade except white) |
| 5 | Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
| 6 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)(b) Two Coatsii) Solvent based interior grade Acrylic Primer |
| 7 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface.Two Coats |
| 8 | (b) Supplying \"Godrej\" mortice lock chromium plated with keys 6 levers including fitting & fixing complete. |
| 9 | Polyurethane Polishing to woodwork with required colour as approved by Engineer-in-Charge with preparing surface including scaffolding and hire charges of compressor machine including cost of filler and hardener material such as P. U. Sealing, P. U. Top coat (Matt/Glossy), Thinner, Spirit etc. and inclusive of all operation, material and labour complete as per direction of Engineer-in- Charge. |
| 10 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in- Charge.(White cement, synthetic adhesive and grout material to be supplied by the contra conc. (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (A) Deep Colour & White |
| 11 | i) Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete.ii) Godrej Hydraulic door closer fitted and fixed complete.(b) Medium type |
| 12 | A) Supplying & laying of approved brand of scratch proof, semi flexible P.V.C. blended homogeneous marble Vinyle flooring in tiles conforming to IS:3461, fixing with synthetic acrylic adhesive after preparing the floor, levelling & smothaning when necessary with suitable putty, as per the design & instruction of the Engineer-in-charge.2 mm thick |
| 13 | M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and inished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labourharges etc. complete) In ground floor |
| 14 | Supplying and fixing of window Curtain set as per instruction of the office. |
| 15 | Supplying and fixing of Executive Quality Vencian window Curtain in Microbiological laboratory, Room no 7 set as per instruction of the office. |
| 16 | Repairing , Welding, Colouring and renovaiton of Rackin Microbiological laboratory, Room no 7Set as per instruction of the office. |
| 17 | Repairing , Welding, Colouring and renovaiton of Chairin Microbiological laboratory, Room no 7 as per instruction of the office. |
| 18 | Supplying and fixing of PVC Wall panelling for prevent the dampness of brick wallin Microbiological laboratory, Room no 7 as per instruction of office. |
| 19 | Inspection and cleaning of aluminum sliding window channels in Microbiological Laboratory, Room No. 7. |
| 20 | Repairing and securing chair cushions in Microbiological Laboratory, Room 7 |
| 21 | Maintenance and servicing of the ceiling fan in Microbiological Laboratory, Room No. 7 |
| 22 | Inspection and repair of the water pipeline, including maintenance and fixation of the water basin in the Microbiological Laboratory, Room No. 7. |
| 23 | Supply and placing of a foot door mat 2\" X 1.5\"in Microbiological Laboratory, Room No. 7 |
| 24 | Repairing and sealing gaps in the laboratory under-counter storage (rear and end sections) and addressing gaps in the false ceiling using ACP panels in the Regional, Chemical, and Hydrological Laboratory, Room No. 9 |
| 25 | Repair and reinforcement of chair wheels, along with welding of aged metal chair frames, in the Regional, Chemical, and Hydrological Laboratory, Room No. 9. |
| 26 | Repairing and Servicing of 1.5 ton AC in Microbiological Laboratory, Room No. 7 |
| 27 | Add GST 18 % on items 1 to 13 |
| 28 | Add Cess 1 % on items 1 to 27 |