| 1 | EARTHWORK |
| 2 | Land Development including earth excavation, demolishing of old structure, disposal demolished materials within a lead of 5 KM…as directed by the Engineer in charge by engaging machineries and manpower. |
| 3 | Earthwork in excavation in foundation trenches or drains etc. not exceeding 2 meters depth including dressing of bottom and sides of trenches and subsequent filling and compaction in 15 cm layes as in column foundations, fence post, etc. and disposal of all surplus soil as directed within a lead of 30metres(b) Hard soil (pick work) |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m. |
| 5 | Providing and filling approved river sand in trences, plinth etc. in layers not exceeding 20cms in depth, consolidating each layer by ramming and watering and dressing complete. |
| 6 | CONCRETE WORK |
| 7 | Providing and laying in position cement concrete of specified garde excluding cost of centering and shuttering. All works upto plinth level 1:2:4 (1cement :2 course sand : 4 stone, aggregate 20mm nominal size) |
| 8 | Providing and laying in position cement concrete of specified garde excluding cost of centering and shuttering. All works upto plinth level… 1:3:6 (1cement :3 course sand : 6 stone aggregate 20mm nominal size) |
| 9 | DAMP-PROOF COURSE |
| 10 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1cement : 2 course sand : 4, stone aggregate 12.5mm size) |
| 11 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer\"s specification. |
| 12 | REINFORCED CEMENT CONCRETE |
| 13 | Providing & laying in position reinforced cement concrete excluding cost of centering & shuttering, finishing and reinforcement in: All work upto plinth level.(a). 1:1.5:3 (1cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size) |
| 14 | Reinforcement cement concrete work in walls including attached pillasters, columns, pillers, posts, piers, abutments, return walls, retaining walls, struts, buttresses, string or lacing courses, fillets etc. upto floor five level excluding cost of centering shuttering etc complete... 1:1.5:3 (1cement: 1.5coarse sand: 3 graded stone aggreagte 20mm nominal size). |
| 15 | Reinforcement cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, window sills, stair cases, spiral stair cases, cantilevers upto floor five level, excluding cost of centering shuttering etc. complete with 1:1.5:3 (1cement : 1.5 Coarse sand : 3 stone aggregates 20mm). |
| 16 | FORM WORK |
| 17 | Centering and shuttering including strutting propping etc. and removal of form for all heights: Foundations, footings, bases of columns etc. for mass concrete. |
| 18 | Centering and shuttering including strutting propping etc. and removal of form for all heights: Suspended floors, roofs, landings, shelves and their support, balconies and chajjaj.etc. |
| 19 | Centering and shuttering including strutting propping etc. and removal of form for all heights:Lintels, beams, plinth beams, girder, bressumers and cantilevers etc. |
| 20 | Centering and shuttering including strutting propping etc. and removal of form for all heights: Columns, pillars, piers, abutments, posts and struts. |
| 21 | STEEL REINFORCEMENT |
| 22 | Steel reinforcement for RCC work including straighthening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500 or more |
| 23 | BRICK WORKWITH BRICKS |
| 24 | First class brick work in foundation and plinth in: cement mortar 1:4 (1cement :4 course sand) |
| 25 | Half brick masonry with first class brick in superstructure above plinth level upto floor V level.in cement mortar 1:4 (1cement : 4 course sand) |
| 26 | WOODWORK |
| 27 | Providing 1st class teak wood dressed in frames of chaukat for doors, windows, clerestory windows fixed in position |
| 28 | Providing and fixing factory made door shutters 30mm thick made of prelaminated flat pressed three layer particleboard conforming to IS : 12823 exterior grade (Grade-I Type-II) having one side decorative lamination of approved shade including 2nd class teak wood lipping of 25mm wide x 12mm thick size with necessary screws and black enamelled M.S. butt hinges complete as per direction of the Engineer-in-Charge. |
| 29 | ALUMINIUM WORKS |
| 30 | Providing and fixing anodised aluminium work for doors, windows, ventilations and partitions with extruded built up standard sections /other sections of approved make conforming to IS: 733 and IS: 1285...fixing with dash fasteners of required dia and size,including necessary filling of gaps at junctions at top ,bottom and sides with required PVC/neoprene gaskets etc. Aluminium sections shall be smooth,rust free,straight, mitred and jointed mechanically wherever required including cleat angle,aluminium snap beading for glazing/paneling,CP brass/stainless steel screws all complete including fixing of glasses but excluding the cost of glasses (i) Anodised....2 track windows/Ventilators |
| 31 | Providing and fixing anodised aluminium work for doors, windows, ventilations and partitions with extruded built up standard sections /other sections of approved make conforming to IS: 733 and IS: 1285...fixing with dash fasteners of required dia and size,including necessary filling of gaps at junctions at top ,bottom and sides with required PVC/neoprene gaskets etc. Aluminium sections shall be smooth,rust free,straight, mitred and jointed mechanically wherever required including cleat angle,aluminium snap beading for glazing/paneling,CP brass/stainless steel screws all complete including fixing of glasses but excluding the cost of glasses (i) Anodised....3 track windows/Ventilators |
| 32 | Providing and fixing galzing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.: (a) With glass panes of 5.00mm thickness |
| 33 | Providing and fixing alluminium sliding door bolts(aldrops) anodised transparent or dyed to required colour or shade with nuts and screws etc. complete… 250 x 16 mm |
| 34 | Providing and fixing Alluminium Tower Bolts (socket bolts) anodised transparent or dyed to required colour or shade with nuts and screws etc. complete 150 mm |
| 35 | Providing and fixing alluminium handles anodised transparent or dyed to required colour or shade with necessary screws, etc. complete… 125mm |
| 36 | Providing and fixing 150mm bright finished brass floor door stopper with rubber cushion, screws, etc. to suit shutter thickness complete. |
| 37 | STEEL WORK |
| 38 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 39 | Providing and fixing MS fan clamp 12mm dia HYSD bar bent to shape with hooked endin RCC slabs during laying including painting the exposed portion of loop complete. |
| 40 | Providing and fixing stainless Steel ( grade 304) railing made of hollow tubes,channels, plates etc. including welding,grinding,buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete,i/c fixing the railing and with necessary accessories & stainless steel dash fastners, stainless steel bolts etc. of minimum 80 cm height in staircase,balcony,corridor etc.consisting of 75 mm for rail and post, 63 mm for longitudinal intermediate rail and 25mm of vertical section,spacing 125mm interval and as per approval of Enigineer-in Charge. |
| 41 | FLOORING |
| 42 | Providing and filling stone aggregate of size below 90mm in plinth etc. in layers not exceeding 10cm in depth, consolidating each layers by ramming and watering and dressingcomplete. |
| 43 | Cement concrete flooring 1:2:4 (1cement : 2 sand : 4 well graded stone aggregate 20mm size) finished with a floating coat of neat cement including cement slurry etc. complete but excluding cost of nosing of step etc. … 40mm thick. |
| 44 | Cement plaster skirtingor dado (upto 30cm height) with cement mortar 1:3 (1cement : 3 sand) finished with a floating coat of neat cement including rounding of junction with floor. |
| 45 | Providing & laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) withwater absorption less than 0.08 % and conforming to IS:15622 of of approved make, in all colours andshades ,laid on bed of 20mm thick cement mortar 1:4( 1 cement : 4 coarse sand)including the joints with white cement and matching pigments etc.complete as per design colours . (a) Double charge |
| 46 | Providing & laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) withwater absorption less than 0.08 % and conforming to IS:15622 of of approved make, in all colours, shades in skirting/dado,riser of steps, over 12 mm thick bed of cement 1:3 ( 1 cement : 3 coarse sand)including the joints with white cement and matchingpigments etc.complete. (a) Double charge |
| 47 | Coloured polished granite slab of size not less than1200mm x 600mm x 20mm thick in flooring,treads of steps andlandings laid over 20mm (average) thick base of cement mortar 1 : 4 and jointedwith white cement slurry including rubbing and polishing complete.(b) Galaxy black |
| 48 | CERAMIC GLAZED TILES |
| 49 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12mm thick bed cement mortar 1:3 (1cement : 3 coarse sand) and jointing with cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 50 | Providing and laying rectified glazed ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS 15622 of approved make in all colours, shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1cement : 4 course sand) including pointing the joints with white cements and matching pigments etc. complete. as per designed colour... Matt/Antiscratch |
| 51 | SANITARY INSTALLATION |
| 52 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm uPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the wallsand floors wherever required: (a) Orrisa pan with integral type foot rests (i) White |
| 53 | Providing and fixing vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with allfittings and fixtures complete, including cutting and making good the walls and floors wherever required : (a) White |
| 54 | Providing and fixing White vitreous china wash basin Standard of Parryware/ Hindware/ Cera and equivalent make with R.S. or C.I. brackets, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plugs, 32mm C.P. brass waste of standard pattern, 32mm C.P. brass traps and union complete including painting of fittings and brackets, cutting and making good the walls wherever required.(a) Vitreous China Wash basin size 630x450 mm with single 15 mm C.P. brass pillar taps, (i). White |
| 55 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (Hindware or equivalent) (a). Single Sink 610x510 mm bowl depth 200mm |
| 56 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing |
| 57 | Providing and fixing C.P. brass towel rail with two C.P. brass brackets to wooden cleats with C.P. brass screws (a) 750x20mm size. |
| 58 | Providing and fixing on wall face SWRPVC soil, waste and vent pipes including jointing with rubber lubricant/cement solvent complete. (a) 110mm dia. |
| 59 | Providing and fixing SWRPVC socket including jointing with rubber lubricant/cement solvent. (a) 110mm dia socket. |
| 60 | Providing and fixing single equal SWRPVC plain junction of required degree with access door (T-junction)(a) 110x110x110mm |
| 61 | Providing and fixing SWRPVC plain bend of required degree (87.50° ) including jointing with rubber lubricant/cement solvent complete. (a) 110 mm dia. |
| 62 | Providing and fixing on wall face SWRPVC soil, waste and vent pipes including jointing with rubber lubricant/cement solvent complete. (a) 75mm dia. |
| 63 | Providing and fixing SWRPVC plain bend of required degree (87.50°) including jointing with rubber lubricant/cement solvent complete. (a) 75 mm dia. |
| 64 | Providing and fixing single equal SWRPVC plain junction of required degree ( T-Junction ) (a) 110x110x110mm. |
| 65 | FINISHING |
| 66 | 12mm cement plaster 1 : 4 (1 cement : 4 fine sand) |
| 67 | 15mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement : 4 coarse sand) |
| 68 | Providing and applying plaster of Paris of 2mm thickness over plastered surface to prepare the surface even and smooth. |
| 69 | Applying priming coat with ready mixed primer of approved brandand manufacture on plaster surface. (a) Ready mix white primer. |
| 70 | Distempering with oil bound washable distemper of approved brand and manufacture and of required shade and colour to give an even shade on new work (two or more coats). |
| 71 | EXTERIOR FINISHING |
| 72 | Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade. New work (two or more coats) |
| 73 | Applying priming coat with ready mixed primer of approved brand and manufacture on plaster surface. (a) Ready mix pink primer. |
| 74 | Painting with synthetic enamel paint of approved brand and manufacture in all shades on new work (two or more coats).a) General quality |
| 75 | WATER SUPPLY |
| 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Enigineer in Charge. Internal work-Exposed on wall(a) 15mm dia nominal bore |
| 77 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Enigineer in Charge. Internal work-Exposed on wall(b) 20mm dia nominal bore |
| 78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineerin Charge.(a) 25mm dia nominal bore |
| 79 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineerin Charge.(b)32mm dia nominal bore |
| 80 | Making connection of CPVC pipes distribution branch by providing and fixing equal Tee with jointing, testing complete including cutting and making good etc. (a) 15 mm nominal dia |
| 81 | Making connection of CPVC pipes distribution branch by providing and fixing equal Tee with jointing, testing complete including cutting and making good etc.(b) 20mm dia nominal bore |
| 82 | Making connection of CPVC pipes distribution branch by providing and fixing equal Tee with jointing, testing complete including cutting and making good etc. (c) 25mm dia nominal bore |
| 83 | Making connection of CPVC pipes distribution branch by providing and fixing equal Tee with jointing, testing complete including cutting and making good etc. (d) 32mm dia nominal bore |
| 84 | Making connection of Astral CPVC pipes distribution branch by providing and fixing reducing Tee with jointing, testing complete including cutting and making good etc.. (a) 25x25x20mm |
| 85 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Elbow 90° with jointing, testing complete including cutting and making good etc. (a). 15 mm dia nominal bore |
| 86 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Elbow 90° with jointing, testing complete including cutting and making good etc. (b). 20 mm dia nominal bore |
| 87 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Elbow 90° with jointing, testing complete including cutting and making good etc. (c). 25 mm dia nominal bore |
| 88 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Elbow 90° with jointing, testing complete including cutting and making good etc. (d). 32 mm dia nominal bore |
| 89 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Female Adaptor (Brass) with jointing, testing complete including cutting and making good etc. (a) 15mm dia nominal bore |
| 90 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Female Adaptor (Brass) with jointing, testing complete including cutting and making good etc. (b) 20mm dia nominal bore |
| 91 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Female Adaptor (Brass) with jointing, testing complete including cutting and making good etc.(c) 25mm dia nominal bore |
| 92 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Socket/Coupling with jointing, testing complete including cutting and making good etc. (a) 15mm dia nominal bore |
| 93 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Socket/Coupling with jointing, testing complete including cutting and making good etc.(b) 20mm dia nominal bore |
| 94 | Making connection of CPVC pipes distribution branch by providing and fixingSocket/Coupling with jointing,testing complete including cutting and making good etc. (c) 25mm dia nominal bore |
| 95 | Making connection of CPVC pipes distribution branch by providing and fixingReducer coupling with jointing,testing complete including cutting and making good etc. (b) 20 x 15mm |
| 96 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Reducer Coupling with jointing, testing complete including cutting and making good etc. (a) 25 x20mm |
| 97 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Reducer Coupling with jointing, testing complete including cutting and making good etc. (f) 32 x 25mm |
| 98 | Providing and fixingCPVC Ball valve / Globe/Stop & waste valve/Boiler drain etc.Complete (a) 25 mm |
| 99 | Providing and fixingCPVC Ball valve / Globe/Stop & waste valve/Boiler drain etc.Complete (b) 32 mm |
| 100 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 (a) 15 mm nominal bore. Class-I |
| 101 | Providing and fixing 15 mm nominal bore C.P. brass angle stop cock for basin mixer and geyser points of approved qualityconforming to IS:8931. (a).Class-I |
| 102 | Providing and fixing chromium plated brass long neck pillar cock of approved quality.(a) 15mm nominal bore. Classik |
| 103 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards. (a) 15mm nominal bore |
| 104 | Providing and fixing chromium plated brass shower rose with 15 or 20mm inlet.(a) 100mm dia CP brass shower rose. |
| 105 | Providing and fixing factory made PVC door frame made of PVC extruded section (Chaukhat) having overall dimension of 48x40 mm (tolerance + 1 mm) with wall thickness 2.0 mm + 0.2 mm, corners of the door frame to be mitred and joined by means of plastic/M.S. galvanished brackets and stainless steel screws. The hinge side vertical of the frames reinforced by galvanised M.S. tube of size 19x19 mm and 1 mm + 0.1 mm wall thickness and 3 Nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge. (Sintex, Plasopan or equivalent) |
| 106 | Factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. \"U\" cleats. The shutter frame filled with a uPVC multi chambered single panel of size not less than 620 mm,having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened withnuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter) (Sintex, Plasopan or equivalent). (a) 30 mm thick shutter |
| 107 | Providing and fixing wire gauge shutters with frames of 1st class local wood using galvanised M/S wire gauge of average width of aperture 1.4mm with wire of dia. 0.63mm for doors, windows and clerestory windows including bright finished or/and black enamelled M/S butt hinges with necessary screws(a) 30mm thick. |
| 108 | Providing anf fixing anodised alluminium towel rail with two anodised alluminium brackets to wooden cleats with C.P brass screws..(a) 750 x 20mm size |
| 109 | Providing and fixing toilet paper holder.(a) CP.brass toliet paper holder of standard size |
| 110 | Providing and fixing liquid soap container with CP. Brass lid and brackets fixed to wooden cleats with CP.brass screws.(a) Glass container with CP. Lid and brackets |
| 111 | Diluting and injecting chemical emulsion for anti termite treatment during construction.. (a) Treatment of soilunder floor using chemical emulsion |