| 1 | Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in in any type of soil. |
| 2 | Returning and filling in, including, spreading, levelling, watering and well raming in layers n.exc 25cm in hard/Dense soil. |
| 3 | Removing excavated material (Soil) n.exc. 50m and sepositing where directed at a level n.exc. 1.5m above the starting point |
| 4 | M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete. |
| 5 | M&L for RCC M-30 design mix (20mm graded stone aggragates) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 6 | M&L for RCC M-30 design mix (20mm graded stone aggragates) in Columns, pillars, piers, posts and struts |
| 7 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 8 | M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surface of concrete square/ractangular or polygonal. |
| 9 | M&L for Mild steel TMTbars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 10 | Ditto above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 11 | M&L Pre-cast cement concrete block masonry with solid blocks Type C1 1:3:6, exc. 10 cm in width and setting in Cement mortar (1:4) mortar, complete. |
| 12 | M&L rendering 15mm thick on fair faces of brick or stone masonry or concrete surface in CM 1:4 is to be finished even and smooth(without using extra lime or cement) |
| 13 | S&Frolled mild steel in roof trusses(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing(Beam,tee, angle, channel or hollow square sections) incl distance pieces, cleats, etc conforming to grade Fe-410W-(Gde E-250 Quality A). |
| 14 | S&F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 15 | S&FSteel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240.Complete all As specified directed |
| 16 | M&L for Framed work as in arnamental doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-290 grade E-165. |
| 17 | Preparation of new steel and iron surfaces of any description over 10 CM width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 18 | S&F Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick with AZ 150 GSM of colour having tensile stength of 550Mpa as in roof coverings/cladding to wall, fixed with self tapping screws as specified.(make JSW) |
| 19 | S&F suspended false ceiling and vertical cladding using (ACP) Aluminium Composite Panel sheet 3mm thick incl jointing cleats etc including aluminium rectangular hollow section for grid suspension ceiling and wall cladding fixed to MS or Concrete surfaces with stainless steelscrews toaluminium framed work. incl requisite size of aluminium fillets complete all as specified and directed. |
| 20 | M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like 20mm thick screed in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 21 | Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in any type of soil. |
| 22 | M&L cement concrete 1:4:8 type D2 (40mm graded aggregate) in foundations, filling and mass concrete or as in floor sub base .complete all as specified and directed |
| 23 | M&L for machine pressed pre cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement and pigment. Complete all as specified. |
| 24 | M&L for sand filling under floors or in foundations including watering and consolidation |
| 25 | M&L for Durastone Heavy Duty Vitrified tiles (400x400mm) 10-12mm thick in floor set and jointed with neat cement slurry and pointed in coloured cement to match over and incl screed bedor bedding layer of mortar 20mm in cement 1:6 complete all as specified and directed |
| 26 | S&F 30cm high, 05mm thick and 10cm wide stainless steel grade 304 alphabets fixed where directed and approved by EIC complete all as specified |
| 27 | M & L forproviding and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line level and curvature jointed with cement moratr 1:3 (1 cement :3 sand) incl making jointing except shall not 5 mm etc complete all as specified |
| 28 | S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cmlength \"medium grade \" with rubber ring joint, fixed to walls with dash ture nut and MS ring (25x6 FI used) bolt at every 1.5 mtrs length complete , incl taking up/down old pipe with all fittings all as specified and directed by Engineer-in-charge. |
| 29 | S&F PVC (SWR) bends with or without door of 110mm bore. |
| 30 | S & F MS bands, straps, supports or stays for rainwater, ventilating pipes, including bolts if reqd, hooks(stay), hook and pintle hinges, large hasp and staples, clamps, hold fasts, wall ties, plain angle cleats for securing purlins to wood trusses or rafters and similar small articles confirming to Fe-290 Gde E-165. |
| 31 | S&F for 150mm bore PVC valley gutter pipes (Traingle/half circle/rectangular) single socketed Pressure rating @4Kg/Sq cmlength \"medium grade \"fixed with pvc solvent as in rain gutterwith and inclMS frame work (angle50x50x5mm) at every 1.5 mtrs length at height of minimum 10m complete all as specified and directed. |
| 32 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 coreMake: Polycab/ KEI/ Apar |
| 33 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 34 | Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 35 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 36 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. |
| 37 | Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified.Make: Mehtab tiles/ National |
| 38 | M&L for cutting existing road/hard and dence soil not exc 45x50 cm in wide & depth getting out excaveted materials for laying GI tube; returning filling & well rammin watering finish surface 10 cm from top using PCC 1:3:6 not less than 4 inch thick; including removal of surplas soil all as per directed. |
| 39 | S&F of HDPE pipe 50 mm dia, PN-10 for laying in ground, road crossing etc for cable protection including necessary fittings, clamps for supports, etc all as. Make-Prayag/ Sudhakar/Plasto/ Prince |
| 40 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm ,4 core, 1100 Volts grade.Make: Polycab/ KEI/ RPG |
| 41 | M & L forpoint wiring complete with proper colour coding with 1100 Volts grade, 1.5 Sqmm PVC insulated FRLS, unsheathed, wire confirming to IS-694, Part II, ISI marked with multistranded copper conductor drawn in and including PVC concealed conduit of suitable size of wall/ RCC slab/ ceiling/ colunms/ beams etc with all accessories, fittings, PVC junction boxes etc,for mounting modular switches, sockets, fan regulators etc, also including 1.5 Sqmm, PVC insulated, FRLS unsheathed, 1100 Volts multistranded copper conductor green colour as contineous earth wire connected to common earth dolly for one light point/fan/bell point controlled by one way switch, complete all as specified and directed. Note : Rates included for concealed cutting as required at site without any damage and making good in CM 1:4 and matching the surface as required 2 all screws and washer for point wiring shall be Stainless steel. Nothing is extra shall be admisible on this account Make of wire : Polycab/ KEI/ BenloMake of conduit: Precision/ Presfit |
| 42 | All as per item No.41 above but wiring complete with 2.5Sqmm for 3 pin 15 A socket multipurpose on independent board complete all as specified and directed. |
| 43 | S&F LED downlighter, 20 Watt complete all as directed by Engr-in - Charge.Make : Bajaj/ Wipro/ Jaquar |
| 44 | S&F 6 way DB double door type Triple pole and neutral operating on 415 V, 50Hz, AC supply complete comprising the following accessoriesa) MCB SPN 25 Amp 10 KA \"C\" series- 02 Nosb) MCB SP 20 Amp 10 KA \"C\" series- 02 NosMake: C&S/ Legrand/ Schnieder |
| 45 | Supply install commissioning and testing floor mounted outdoor cubical type LT Panel Board, CPRI type tested, fabricated out of 3.15 mm thick CRCA Sheet and suitable size of angle iron frame of suitable size, factory made, compartmental type totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry andexist from bottom with cable glands and gaskets, Copper bus bar fixed on porcelain insulator with internal copper control wiring with suitable size, Copper flexibles to be used for incoming and outgoing connection of all switches/MCCB\"s & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and bus bar size of all phases and neutral suitable for withstanding 1.5 time of incoming rated current and to be connected with Copper lugs, with seven tank process, including powder coated with two coats of synthetic enameled paint on the surface externally & internally after duly surface preparation including necessary PCC (1 : 3 : 6) type C2 as in foundation complete all as directed, comprising of the following : |
| 46 | (a) Electolytic copper bus bar of capacity 100 Amps for RYB&N(b) Incomer- MCCB 63 Amp 4 Pole- 01 No. Make- L&T, C&S, Legrand(c) Outgoing- i) MCB SPN 40 Amp 10KA- 01 Nos Make: C&S/ Legrand/ L&Tii) MCB SPN 32 Amp 10KA- 01 Nos Make: C&S/ Legrand/ L&T(d) 0-200 volts digital type volt meter with selector switch - 1 NoMake L&T , C&S, Schneider.(e) 0-100 Amps digital type Ammeter with selector switch - 1 NoMake L&T , C&S, Schneider.(f)LED based indicating pilot lamps in RYB Colour - 1 setMake L&T , C&S, Schneider.Note : (i) The Lay out drawing of the panel shall be got approved by the Vendor from GE before the panel fabrication work. |
| 47 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 48 | M&L Earthing complete with galvanised iron strip 32X6mm earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion Note: (1). 7.5 RM GI strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately. (2) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of GI earth plate. |