| 1 | SCHEDULE \"A\" Part-I (Building/Structures) (To be quoted by the tenderer) |
| 2 | Item No 01 A : Design and construction of Single Story Religious Building (Plinth Area: 347.25 Sqm) with permanent specification including internal water supply and inetrnal electric supply, RCC Framed Construction, Provn of ATT, M-25 Concrete, Provn of Mosquito proofing, exterior emulsion (emulsion paint/ weather coat), roof treatment with polymeric water proofing treatment, Complete allspecified in soil bearing capacity report, design basis report drawings and tender documents. |
| 3 | Item No 01 B: Design and construction of Single Story Garrage for B Vehicles Height required 3.2 M (Plinth Area: 467.36 Sqm) with permanent specification including internal electric supply, RCC Framed Construction,M-25 Concrete, exterior emulsion (emulsion paint/ weather coat), roof treatment with polymeric water proofing treatment, Complete allspecified in soil bearing capacity report, design basis report drawings and tender documents. |
| 4 | Item No 01C : Design and construction of Single Story Garrage for B Vehicles Height required 3.6 M (Plinth Area: 605.87 Sqm) with permanent specification including internal electric supply, RCC Framed Construction,M-25 Concrete, exterior emulsion (emulsion paint/ weather coat), roof treatment with polymeric water proofing treatment, Complete allspecified in soil bearing capacity report, design basis report drawings and tender documents. |
| 5 | Item No 01D : Design and construction of Single Story Garrage for B Vehicles Height required 3.6 M (Plinth Area: 415.36 Sqm) with permanent specification including internal electric supply, RCC Framed Construction,M-25 Concrete, exterior emulsion (emulsion paint/ weather coat), roof treatment with polymeric water proofing treatment, Complete allspecified in soil bearing capacity report, design basis report drawings and tender documents. |
| 6 | Item No 01E : Design and construction of Single Story Garrage for B Vehicles Height required 4.5 M (Plinth Area: 413.31 Sqm) with permanent specification including internal electric supply, RCC Framed Construction,M-25 Concrete, exterior emulsion (emulsion paint/ weather coat), roof treatment with polymeric water proofing treatment, Complete allspecified in soil bearing capacity report, design basis report drawings and tender documents. |
| 7 | Item No 01F : Design and construction of Single Story Apron for B type Vehicles (Plinth Area: 2092.08 Sqm) with permanent specification including and inetrnal electric supply, RCC Framed Construction,M-25 Concrete, exterior emulsion (emulsion paint/ weather coat), roof treatment with polymeric water proofing treatment, Complete allspecified in soil bearing capacity report, design basis report drawings and tender documents. |
| 8 | Sch \"A\" Part-II (External Electric Supply)Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule \"A\" Part-II against the lump sum price inserted by the MES. |
| 9 | Sch \"A\" Part-III(External Water supply)Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule \"A\" Part-III against the lump sum price inserted by the MES. |
| 10 | Sch \"A\" Part-IV(Road, Path Curvert)Lump sum price worked out by the contractor for (Road, Path Curvert)as listed in Schedule \"A\" Part-IV against the lump sum price inserted by the MES. |
| 11 | Sch \"A\" Part-V (Sewage Disposal)Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule \"A\" Part-V against the lump sum price inserted by the MES. |
| 12 | Sch \"A\" Part-VI(Area Drainage)Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule \"A\" Part-VI against the lump sum price inserted by the MES. |
| 13 | Sch \"A\" Part-VII(Site Clearance) Lump sum price worked out by the contractor for (Site Clearance)as listed in Schedule \"A\" Part-VII against the lump sum priceinserted by the MES. |
| 14 | Note for Srl No 2 to 13The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 11by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 15 | Schedule \"A\" Part-VIII (Miscellaneous items of works) |
| 16 | Road Path Culvert |
| 17 | Item No 02 : S & F in repairs PVC speed breaker DA-1008 of size 500mm x 365mmx50mm(reflector on both sides) complete all as specified and directed |
| 18 | Sewage Disposal |
| 19 | Item No 03 : Earth work in excavation in any type of soil by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all as specified and directed |
| 20 | Item No 04 :Earth work in excavation in ordinary rock by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all as specified and directed |
| 21 | External Water supply |
| 22 | Item No 05 : M & L for construction of brick masonryvalves pits, of the 900 mm x 900 mm x 900 mm internal dimension complete with 3.15 mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC work complete. |
| 23 | External Electric supply |
| 24 | Item No 06 : M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground (earth pit not less than 2.25 mtrsdeep below ground level) with top edge of the platenot less than 1.5 mtrs below normal ground level,connected togalvanised iron strip 4mm dia GI wire as earthing lead by means of bolts, nuts, check nutsand washers of galvanised iron or steel all as shownin electrical plate No 3 in SSR Part -I connected to earthingtest point all as specified complete withexcavation & earth work, PCC pit with 50mm thickRCC cover (grade M-15) having suitable handle(10mm MS Rod) 20mm dia GI medium grade ISI marked watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth leadconductorall as directed and testing on completion. |
| 25 | Item No 07 : Supply and installationtesting and commissioning LT Panel out door type, water and vermin proof protection of minimum size 1400mm x 1000mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitmentsuppliedfitted and connected internally complete with bus bar with other accessories and alsoincluding removing old exisisting one complete all as specified and as directed. |
| 26 | (a)Copper strip busbar of 200 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Noswith compatible CTs, Digital ammeter and volt meter with selector switches , set of LED type,indicating lamps R,Y,B on incoming side.(b) MCCBTPN, 415 volt adjustable thermal magnetic release type with rotary handle, 80 Amps with breaking capacity 25 KA- 01 No (Incoming )(c) MCCB TPN 415 volt adjustable thermal magnetic release type with rotary handle 63 Amps wirh breaking capacity 25 KA-06Nos (outgoing)(d) MCB TPN 63 Amps Outgoing -02 Nos (e) Chain link fencing of the panel complete all as per standard norms and as specified and directed is included in quoted rate. |
| 27 | Item No 08 : S & F Pressure die cast aluminum alloy housingLED street light fitting90Wattcomprises of pressure die cast Aluminium housing & having system efficiency 110 lumens/Watt i.e 6670 lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 5KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected,THD<10%,CRI>70CCT 5700+/-300K, PF>0.9, Driver efficiency>85%,LM79 report require from NABL Accediated lab all as directed by Engr-in-Charge. |
| 28 | Item No 09 : Supply and installation polycarbonate junction loop in/loop outof internal size 250X210X115 mm made out of FRP (hot moulded type) with weather proof canopy and cocking screws alongwith 5/6 Amp MCB-01 No , 15 Amps rated 3 Pole connnector-01 No, neutral link mounted abd din raiil suitable size for mounting MCB/Connector complete in the box duly fixed to steel tubular pole usin 25 X 3mm FI clamp with suitable gland and lugs for connecting cable including taking down complete all as directed and specified by Engr-in-charge. |
| 29 | Item No 10 : Nature Switch street light controller three phase 5 KW of automatic street light switch using infrared sensor based NATURAL SWITCH for automatic switching of street lights, required illuminance for switching on is ≤30 Lux and for switching off ≥10 Lux also having part night operation 4 to12 hour with contactors and outgoing and incoming MCBs connected with min 10sqmm FLRS multistranded circuit all these must be enclosed in a pole/wall mounted enclosure made of rust proof, electric shock proof and termite proof conforming to IP54 complete all as specified and directed by engineer in charge |
| 30 | Item No 11 : S&F service bracket for street light fitting made out of 40 mm bore light grade GI pipe of length 1.5 mtrlong (approx) bend to shape 115 degree and fix to pole for fixing of street light fitting on pole/wall etcfixed with 2 Nos 32x 6 mm GI clamp, Nut,bolts,washer etc complete all as specified and directed. |