Tender For Provision Of Otm Accommodation At Ajeya Garrison.; 1 SCHEDULE A PART-I (Building and Structure works) is not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only 2 Construction of Administrative Building, Battery charging shop and parking space (G+2) complete with permanent specifications complete all as specified and shown on drawings 3 Construction of Single Living Accn for 29 Havs and 161 ORs and Barber Shop(G+3) complete with permanent specifications complete all as specified and shown on drawings 4 Construction of Cook House and Dining Hall(S/S) complete with permanent specifications complete all as specified and shown on drawings 5 Construction of Fire Point complete all as specified and shown on drawings 6 Construction of Refuse Bincomplete all as specified and shown on drawings 7 SCHEDULE A PART-II to XII under Ser No 6 to 16 are Prepriced by MES 8 Lumpsum price worked out by the contractor for INTERNAL WATERSUPPLY as listed in Schedule A Part-II. 9 Lumpsum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule A Part-III. 10 Lumpsum price worked out by the contractor for PLUMBING WORKSas listed in Schedule A Part-IV. 11 Lumpsum price worked out by the contractor for EARTHWORK AND SITE CLEARANCE WORKS as listed in Schedule A Part-V. 12 Lumpsum price worked out by the contractor for PROTECTIVE WORKS as listed in Schedule A Part-VI. 13 Lumpsum price worked out by the contractor for ROAD /PATH/CULVERT AND HARDSTANDING WORKSas listed in Schedule A Part-VII. 14 Lumpsum price worked out by the contractor for AREA DRAINAGE as listed in Schedule A Part-VIII. 15 Lumpsum price worked out by the contractor for SEWAGE DISPOSAL as listed in Schedule A Part-IX. 16 Lumpsum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Schedule A Part-X. 17 Lumpsum price worked out by the contractor for HOT WATER SUPPLY as listed in Schedule A Part-XI. 18 Lumpsum price worked out by the contractor forEXTERNAL ELECTRIFICATION WORKS as listed in Schedule A Part-XII. 19 SCHEDULE A PART-XIII MISCELLANEOUS B/R AND E/M WORKS is not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only 20 EXTERNAL ELECTRIFICATION WORKS 21 Sand cushioning to under ground cablelaid in trenches for laying of HT/LT UG cables 8 cm wide before laying the cable and 15 cm after laying and punned down to a depth of 10 cmas per MES SSR Part-I (2509) all as specified anddirected. 22 Supply,laying, testing and commissioning of aluminium conductor, XLPE insulated,PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed ,heavy duty 11000 volts (E) grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 95 Sqmm 3 core complete all as specified and directed . 23 Cable jointing kit for 11 KV (earthed) cable for outdoor termination heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable for size 95 Sqmmall as specified and directed by Engr-in-Charge. 24 Supply,laying, jointing and testing and commissioning aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed ,heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 300 Sqmm 3.5 core complete all as specified and directed . 25 Supply,laying, jointing and testing and commissioning aluminium conductor, XLPE insulated,PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed ,heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 185 Sqmm 3.5 core complete all as specified and directed . 26 Supply,laying, jointing and testing and commissioning aluminium conductor, XLPE insulated,PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed ,heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 95 Sqmm 3.5 core complete all as specified and directed . 27 Supply,laying, jointing and testing and commissioning aluminium conductor, XLPE insulated,PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed ,heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 35 Sqmm 3.5 core complete all as specified and directed 28 Supply,laying, jointing and testing and commissioning aluminium conductor, XLPE insulated,PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed ,heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 25 Sqmm 4 core complete all as specified and directed . 29 Supply,laying, jointing and testing and commissioning aluminium conductor, XLPE insulated,PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed ,heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 16 Sqmm 4 core complete all as specified and directed . 30 Gang Operated Air Break Switch (Swing out expulsion fuse insulators), tripple pole mechnical operated from ground level mounted on insulator and steel frame (12 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground level confirming of IS 1818 of 1972 and contineous current rating upto 200 amp and volt 11 KV complete all as specified. 31 Lightning arrestor non liner resistor type comply with IS 3070 Part -I 1985 for alternating current system multple spark gap suitable for voltage grade 11000 volt discharge cap 65 KA complete with all fittings and all as specified. 32 TRANSFORMER: Supply, installation, Testing andCommissioning of Oil Cooled, Copper wound, Step down BIS marked & BEE star labelledtransformer of capacity 315 KVA plinth mounted outdoor type with latest feature complete with standard fitted HT 11 KV 3 phase, LT 433 V 3 phase 4 wire, 50 C/S oil immerse, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at +/-2.5 %to +/-5 % & +/- 7.5 % on HV side and to be changed by means of hand operated off load tap changing gear including first filling of new transformer oil of dielectric strength not less than 55 KV with all fitting and accessories such as LT box with cable gland, HT box with cable gland, Silica gel, breather, Oil level indicator gauge, drain out valve (oil tank),exhaust vent, air release valve, temp gauge, cast iron wheel etc comply with EEL 3 IS 1180 2014 with amendment 1,2,3 & 4 having total losses @ 50% load 955W & total losses @ 100% load 2750W. Following items/ Accessories included in this rate therefore No any extra cost will be paid for this items completeall as specified and directed by Engineer-in-charge. 33 (i) Name, rating & diagram plate (ii) Off circuit tap changing switch(iii) Earthling terminals (iv) Lifting lugs(v) Oil drain valve with plug(vi) Oil filter valve with plug(vii) Conservator with oil filling hole(viii) Thermometer pocket(ix) Air release plug(x) Silicagel breather(xi) Removable inspection opening(xii) Explosion vent(xiii) Chain link fencing of size 4.5m X 4.5m consisting of angle iron of size 65 x 65 x 6mm of height 2.1mtr entrance gate and 40mm stone aggregate all around the transformer plinth all as directed .(xiv) Transformer platform as per manufacturer design. 34 Supply, installation and commissioningand testing of LT Panel cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricatedduly powder coated inside and out side, outer cover made out of 3 mm thick CRCA sheet, internal cover and partitionmade out of 2 mm thickCRCAsheet with angle iron 50 mm x 50 mm x 6mmcovered from all side with front and back openable, weather proof including suitable rating aluminium busbar for 3 phase 4 wire system, wiring with suitable size coppercable and embeded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground withnuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge.Incoming:-(a) MCCB 4 pole, 630 Amp, 36 KA, 415 volts AC with adjustable thermal and adjustable magnetic setting- 01 Nos(b) Aluminiumbus bar 400 Amp TPN - 04 Nos(c) Digital voltmeter 0-500 volts with selector switch - 01 No(d) Digital Amp meter0-500 Amp with selector switch & CT - 01 No(e) Indicator lamp LED type (R, Y, B) complete with bakalite fuse fitting - 01 SetOutgoing:-(a) MCCB 4 pole, 250 Amp, 25 KA, 415 volts AC fixedthermal and fixedmagnetic setting- 02 Nos (b) MCCB 4 pole, 160 Amp, 25 KA, 415 volts AC fixedthermal and fixedmagnetic setting- 02 Nos(c )MCB 4 Pole, TPN 32 Amp,16 KA415 V AC fixedthermal and fixedmagnetic setting -01 Nos 35 Supply, installation and commissioningand testing of LT Panel cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricatedduly powder coated inside and out side, outer cover made out of 3mm thick CRCA sheet, internal cover and partitionmade out of 2 mm thickCRCAsheet with angle iron 50 mm x 50 mm x 6mmcovered from all side with front and back openable, weather proof including suitable rating aluminium busbar for 3 phase 4 wire system, wiring with suitable size coppercable and embeded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground withnuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge.Incoming:-(a) MCCB 4 pole, 200 Amp, 36 KA, 415 volts AC with adjustable thermal and adjustable magnetic setting- 01 Nos(b) Aluminiumbus bar 400 Amp TPN - 04 Nos(c) Digital voltmeter 0-500 volts with selector switch - 01 No(d) Digital Amp meter0-500 Amp with selector switch & CT - 01 No(e) Indicator lamp LED type (R, Y, B) complete with bakalite fuse fitting - 01 SetOutgoing:-(a)MCCB 3 Pole,63 Amp,16 KA415 V AC fixedthermal and fixedmagnetic setting -05 Nos 36 Supply and fixing of electric stainless steel commercial chimney of cap 3500 CFM of size 6 feet hood and size 2 feet length (30 inch in length each with BLDC motor with LED light of suitable size) perforated filter complete along with fixing with help of ankle bolt complete all as specified by manufacturer and making hole for flexible exhaust pipe through cutting of wall and making outlet at outside area complete with fitting complete all as specified and directed. 37 Supply and fixing of food warmer stainless steel body, wheel mounted along with hole for fixing of 4 Nos hot pan (20Kg each) with heating element -02 Nos (2KW) and electric wiring for autocut off and filling of hot water in bottom portion complete all as specified and directed. 38 Cross arm, bracings, supports, clamps and chequered steel back plates, angle iron equal size or any size fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size for cover for cable duct any size and holdingoftwo pole structures, GOD, street light GI bracket, junction boxes and fabrication of anti climbing devices, other works etc as indicated or directed and dulypainted with synthetic enamel aluminium/smoke grey paint over a coat of primercomplete all as specified and directed . 39 Supply & fixing is position cable path indicator made out of MS duly embosing the words LT /HT cable fixed on MS angle iron , at a distance of every 20 mitres & painting the indicators with 2 coats of synthetic enamel paint (Brown colour) over a coat of red oxide primer complete all as specified and as directed . 40 Supply, laying, testing, and commissioning of 3-core PVC insulated and PVC sheathed copper conductor cable of size 1.5 sq.mm, conforming to relevant IS standards, suitable for 1100 volts grade. The cable shall be laid from the pole junction box to the street light connection, including necessary fixing, clamping, and termination at both ends with suitable lugs and glands complete all as specified and directed. 41 LED STREET LIGHT: Supply, fixing and testing of 60 W LED street Light luminairemade up of Pressure Die Cast aluminium housing IP 66 effeiceint protection with heat resistant toughened glass with individual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree) . The luminaire shall be complete available CCT 6500K,IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light should be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall havepower factor more than 0.95 complete all as specified and directed. 42 Note for Item No 36 :- a). SMPS based Driver with lower THD (<10 )shall be potted anti-vibration types. b). LM-79 and LM-80 test report with 1 Lakh burning hours SMD LED life from NABL lab shall be provided. c). CRI (Colour Rendering Index) of fixture shall be > 70.d). CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. e). System Lumen Efficacy shall be > 140 Lm/W.f). 10 KV separate Surge Protection and short circuit and over voltage protection shall be provided as a part of fitting. g). 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. h). Lenses shall be Modular Type. j). PCB used shall be MC PCB type. k). The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. l). CA No. shall be written on each fitting before installation. m). The name of manufacturer to be embossed on the fitting. n). The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover. 43 Supply and fixing new automatic street light switch for LED street light using infrared sensor based nature switch for automatic switching of street light, 440 volt, 3 phase of cap 5-8 KW, outdoor type factory made IP-65 protection having nature switch operating should be based on natural light flux level and selector switch to change the mode of operation, supply indicator with SMC box and locking arrangement. The sensor along withpower Contactor of cap up to 63 Amp and incoming and outgoing MCB TPN cap upto 63 Amp with auto manual operation and overvoltage and over current protection and auto trip & auto reset making arrangement incl internal wiring of copper cable FRLS 10 sqmm single core multistranded and mounted arrangement with clump and nut bolt on wall/poles , dust proof and temper proof complete all accessories as required and provided by manufacturer. 44 Supply and fixing of bracket for street light fitting made out of 40mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by engineer in charge & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light fitting bracket with two coat of red oxide primer and one finishing coat with aluminium paint complete all as specified and directed. 45 Supply & fixing ofjunction box of size 200x150x75mm made of MS Sheet 1.6mm thick, front door openable with fixing screw painting with two coats of synthetic enamel paint over a coat or red oxide including aluminium bus bar 2 Nos of size 20x3mm mounted on epoxy based post insulators and drilled holes for connection all as required and fixed to poles using MS strip of size 20x3mm and nuts & bolts of required size, MCB 10 A single pole all as required at site or directed by Engr-in-charges. 46 M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt startingfrom ground below earth plateupto 150mm above GI plate in alternate layersconnected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel,PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish ,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge,80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified includingprovision of 15 mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete ,all excavation andearth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge. 47 M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt startingfrom ground below earth plateupto 150mm above GI plate in alternate layersconnected to galvanized earth lead wire 4mm (8SWG) by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel,PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish ,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge,80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified includingprovision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete ,all excavation andearth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge. 48 EXTERNAL WATER SUPPLY 49 Cast Iron Air Release Valves with two air Outlets, 100 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed by Engr-in-charge. 50 M&L for brick masonry valve pit of size 90x90x105 cm (internal dimensions of chamber) including 23cm thick wall built in CM 1:6, 15 mm thick plain cement plaster internally in CM 1:4 and flush pointing externally as the work proceeds, PCC 1:5:10 type E2 in foundation 156x156cm size 40mm thick PCC 1:2:4 type B-1 in floor, 50mm thick PCC 1:2:4 as coping over brick work, MS sheet cover of size 112X 112cm X 3 mm thick fixed to angle frame made out of 40x40x3mm angle iron,MS handle to sheet cover,MS hinges welded to frame and sheet cover, painted with two coats of synthetic black paint over a coat of redof red oxide primeron steel work , two coats of white wash on plaster work including excavation and earth work in any type of soil complete all as specified and directed. 51 M&L for making valve pit of size 60 x 60 x 60 Cm ( internal dimensions of the chamber)including and removingthe debrisat a distance not exceeding 50 Mtr and M/L for brick masonry with cement mortar with 1: 6 , 23 cm and flush pointing externally work proceeds in the same mortar complete ( using 30% old bricks & 70% New bricks) complete with the following specificationsand as directed by Engr-in-Charge. Note :-(i) 10mm thick plaster internally in CM 1:6. (ii) Flooring 40mm thick in PCC 1:2:4 type B-1 over 75mm thick hard coreofgauge not exc 63mm thick. (iii)Angle ironframe40X40X6mm thick for cover and mild steel 3mm thick cover with locking arrangement, handle and necessary hinges etc, (iv) PCC 1:3:6 type C-2 100mm thick in foundation. (v) Two coat of synthetic enamelled paint to cover internally and externally over a paint of Red Oxide primer. 52 HOT WATER SUPPLY 53 Supply and installing of the electric water storage heater of ABS body type of 25 ltr capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank along with glass lined Incoloy heating element with anti-corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15 mm dia bore with G I hexagonal adopters/Nuts on the both sides for inlet ( cold water supply) & outlet ( hot water supply) and including provision of wall mounting arrangement and mounding wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and directed by Engr-in-Charge 54 M & L for modular point wiring with 2.5 sqmm (nominal area) PVC insulatedFRLS and unsheathed multistranded copper conductor cable 1100 volts grade drawn through and includingPVC rigidconcealed conduit not less than 1.8 mm thick (ISI marked)with all accessories including suitable modular plate (Inner + Outer) andmodular metalic boxes of suitable sizes including 2.5 sqmmPVCFRLS insulated unsheathed copper conductormultistranded cable for continuous earth conductor connectedto common earth dolly for one 3 pin socket outlet 15Amp multi purpose independent point controlled by 16 Amp, switch, SP, one way, 240 VoltsforSocket, complete all as specified & directed. g :- Note:- Proper colour coding is to be followed as per IS Specification. 55 Supply, Installation, Testing and Commissioning of Solar Hot Water System (Flat Plate Collector) based on indirect transfer of heat of capacity 500 LPD with electric back up (3 runs of 6 Sq mm PVC Copper cable from DB to Solar panel) confirming to ISI complete all as specified & directed. Note : Rates are deems to be included transport and shifted up to roof top of the building all as specified and directed. Make : - Inter Solar/ Supreme/V-Guard. 56 500 Ltrs capacity rotational moulded polethylene water storage tanks, three layers (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part I connecting up pipes including 25 mm bore float valve pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms) with and including inlet and outlet nipple complete all as specified and directed. 57 M & L for lagging to pipes used in internal water supply or plumbing all round with 20 mm thick bonded mineral wool performed SNAP ON pipe sections of density 144 kg/cum conforming to IS 9842 covered with chicken mesh wire netting 25 gauge with 0.01 aluminium foil complete all as specified and directed. 58 Supply and fixing of 1100 volts grade, 6 Sqmm, three-core, heavy-duty PVC insulated and PVC sheathed copper conductor cable (bare annealed), laid and secured with suitable saddle clips, for connection from MCB distribution board to solar water heater, complete as specified and as directed by Engineer-in-Charge. 59 PLUMBING WORKS 60 Supplying and fixing salt-glazed stoneware gully trap, square mounted, type ‘P’, of size 150mm x 150mm, including necessary excavation and earthwork, properly bedded and set in PCC (1:3:6) (nominal mix) block of size 45cm x 45cm, finished with cast iron grating and jointed in cement mortar (1:1), complete all as specified and directed. 61 INTERNAL ELECTRIFICATION 62 Supply and fixing of DBO x MCB Protected socket with sheet steel enclosure single pole 25 Amp with 3 pin plug top for AC connection from socket point to stabilizer complete all as specified and directed. 63 Supply, fixing and testing of high performance IP66 25 Watt LED street Light, housing made up of Die Cast aluminium with street optic lens with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5 sqmm from ceiling rose to 25 watt LED light etc and incl 32 mm bore GI light grade protection pipe upto 1.0 m length with suitable fixing accessories on walls,complete all as specified and directed. 64 Supply and fixing 240V, 10 KA, ‘B’ curve miniature circuit breaker (MCB) of single pole and current carrying capacity 63 Amp in the MCB DB complete with connection, testing and commissioningcomplete all as specified and directed 65 M & L for earthing complete with G.I earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground ( earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5m below the normal ground level connected galvanized earth lead wire 4.0mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 M, including PCC chamber in PCC (1: 2: 4), type B1, using (20mm graded stone aggregate), mild steel frame made out of angle iron of size 40mm x 40 mm x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick Cl cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia light grade GI pipe for watering, 15mm dia medium grade, GI pipe for earth wire protection with and including alternate layer of charcoal dust and common salt. complete all as shown in electrical plate No 3 connected to DBs all as specified and indicated including testing on completion.Note: - (i) GI wire upto 7.5m will be measured and paid under this item only extra lead will be measured and paid seperately under relative link. 66 EARTHWORK AND SITE CLEARANCE WORKS 67 Earth Work in Rough excavation in all kind of soil by mechanical means (hydraulic excavator)(exceeding, 30 cm in depth 1.5m in width as well as 10Sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m as directed by Engr-in- Charge. 68 ROAD / PATH / CULVERT AND HARD STANDING 69 M&L for road line painting upto 100mm to 200mm wide with golden/yellow/white thermostatic compound with reflectorised glass beads on road providing and laying of hot applied thermostatic compound 2.0mm thick including reflectorised glass beads @ 250 gm per sqm area, thickness of 2mm is exclusive of surface applied glass beads as per IRC 35, including cleaning of old road marking paint, the finshed surface to be levelled, uniform and free streaks and holes in addition where arrows of letters are to be provided thermostatics compound should be machine sprayed and the colour of compound, complete all as specified and directed. 70 SEWAGE DISPOSAL 71 M&L for DWCPE 180(OD)/163(ID) mm bore pipe , laid and jointed complete with collars all as specified and directed. 72 M&L forDWCPE 200(OD)/175 (ID) mm bore pipe ,, laid and jointed complete with collars all as specified and directed. 73 RCC Septic tank conventional type for 100 User design to carry out sewage and sullage water excavation in any type of soil , PCC 1:4:8 below foundation RCC-M-30 Design Mix in Walls , base slab, Baffle wall and roof slab including beams etc, with vent shaft , manholes openningwith cover conection etc complete with effective depthof 1.5 mand over all depth of 3.0m , complete all as sepecified. Ref. Drg.No. CEPZ/STD-199/20 Sheet 1/2 to 2/2 Dated 16.11.2020 74 Sokage wells ,excavation in any type of soil , foundation in PCC 1:3:6 , walls of honey combing masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM. RCC cover slab in M-25/ SFRC cover ,interconnection pipes ,RCC/ DWC complete filled with brick bats of size3.60 m dia X 4.50m depth complete all as specified. Ref. Drg.No. CEPZ/C-TD-013/13 Sheet 1/5 to 5/5 Dated 11.09.2013