Tender For Provn Of Certain Spl Repair And Lbw Work Under Ge Dehradun; 1 Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 2 Material and labour for brick work with sub class B brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. 3 Material and labour for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4, surface finished even and fair complete all as specified and directed. 4 Material and labour for 12-15 mm thick Granite, of any type, table rubbed and polished in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding complete all as specified and directed. 5 Demolition of reinforced cement concrete as in roofs, floors, beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed. 6 Material and labour for RCC (1:2:4) type B-1, using 20 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. 7 Material and labour for RCC (1:2:4) type B-1, using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed. 8 Material and labour for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers including supports, overhangs etc. also spays between floors and beams etc. for flat fair finished surfaces complete all as specified and directed. 9 Material and labour for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; nexc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 10 Supply and fixing for mild steel TMT bar 10 mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. 11 All as per item No 10 here in above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed. 12 Dismantling of wrought iron or mild steel work of any description not otherrwise provided for complete all as specified and directed. 13 Supply and fixing for Framed work such as grills, gratings, etc. or hand rails with ends of bars (angle, hollow section) shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. 14 Dismantling of boarding, any description, fixed with screws in any position complete all as specified and directed. 15 Supply and fixing 3mm thick ACP sheet ACP (Aluminium composite panel) fixed with screws on existing mild steel frame complete all as specified and directed.Note: Mild steel frame will be measured and paid separately. 16 Supply and fixing for stainless steel 304 grade pre fabricated letters of size 18 height fixed in position by screws complete all as specified and directed. 17 Supply and fixing Acrylic pre fabricated logo of size 18 height fixed in position by screws complete all as specified and directed. 18 Material and labour for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10 cm width or girth & complete all as specified and directed. 19 M&L for cement concrete type B1 1:2:4 (20mm graded aggregate) as in window or door cills, lintels, copings. kneelers, apex stones, posts, boundary pillars, bonders (for stone walling), brackets, etc. with plain fair faces, including chamfers, weatherings, throating etc. complete all as specfied and directed. 20 Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr depth and getting out in any type of soil complete all as specified and directed. 21 Returning filling in incl spreading, levelling, watering and well ramming in layers n.exc 25 cm thick each layer complete all as specified and directed. 22 Removal of surplus soil to a distance n exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed. 23 M&L for Plain cement concretetype D-2, 1:4:8 (40 mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed. 24 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etcpier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting outcomplete all as specified and directed. 25 M&L for cement concrete type C2 1:3:6 (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed. 26 S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming toFe 410-W(Gde E-250) quality-A all as specified and directed 27 M&L for 304 grade stainless steel hollow tubes with base plate, gusset plate, bracing including stainless steel nuts and bolts welding etc as required ( TIG welding or Tungesten Arc welding) as in vertical posts for supporting the roof frame/truss including grinding and polishing complete all as specified and directed (Note:Roof frame/Truss not included in this Item) 28 S&F 3 mm thick Nylon netting with 25mmx25mm aperture for bird proofing fixed with screw to framed ceiling complete all as specified and directed. 29 S&F pre-painted semi-circular or straight (as directed) galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed. 30 S&F polycarbonate sheets 8mm thick ,60 micron, ultra violet coated double layered coloured and as approved by GE and fixed with aluminium angles profile rubber gasket silicon screws etccomplete all as specified and directed. 31 M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10 cm width or girth & complete all as specified and directed. 32 M&L for Brickwork (except bricks) with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortor 1:6 (bricks obtained under item No-1 will be used) complete all as specified and as directed. 33 Taking down cement plastering of any description on brick/stone/concrete wall surfaces of any description incl racking out joints hacking for key,scrubbing down with water etc. complete all as specified and as directed. 34 M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished surfaces even and smooth complete all as specified and as directed. 35 M&L for new plastered surface of walls including corners and applying two coats of distemper oil emulsion over applying of 1..50mm thick wall care putty finish wall surface even & smooth by roller complete all as specified and directed. 36 M&L for complete removal of existing treatment of walls incl corners and applying two coats of distemper oil emulsion over applying of 1.50mm thick wall care putty finish wall surface even & smooth by roller complete all as specified and directed. 37 Material and labour for preparation of newly plastered surface of walls including corners to receive the coats as per manufacturer directions and applying two coats of SmartCare Damp Proof Advanced of approved colour consist of fiber reinforced elastomeric liquid applied waterproofing membrane, formulated with select elastomeric and resilient acrylic polymers and reinforcing synthetic fiber which forms a thick, seamless, durable membrane upon curing and offers ultimate waterproofing complete all as specified and directed by Engr-in-Charge. 38 Material and labour for preparation of old plastered surface of walls including corners to receive the coats as per manufacturer directions and applying two coats of SmartCare Damp Proof Advanced of approved colour consist of fiber reinforced elastomeric liquid applied waterproofing membrane, formulated with select elastomeric and resilient acrylic polymers and reinforcing synthetic fiber which forms a thick, seamless, durable membrane upon curing and offers ultimate waterproofing including preparation of surfaces complete all as specified and directed. 39 M&L for preparation of new wooden painted surfaces including preparation and applying two coat of synthetic enamel paint any description, over a coat of pink primer, not overwise described, over 10 cm width/girth complete all as specified and directed. 40 M&L for preparation of old painted surfaces of wood over 10 cm width/girth and applying one coat of synthetic enamel paint all as specified and directed. 41 Dismantling floor hearth or wall tiling including cement motor bedding (Including backing), removing serviceable tiles to stone and rubbish off the premises 42 M&L for Vitrified Ceramic tiles light shed /double charged 7-8 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. including screed bed 15 mm thick in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to matchwith tile adhesive complete all as specified 43 Description same as per item No 42above but as in skirting including 10 mm thick rendering in cement mortar 1:4, complete. 44 M&L non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm x 6- 7 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 and dismantling of existingtiling including cement mortar bedding (but not backing) andrubbish off the premisescomplete. 45 M&L for coloured Glazed ceramic tiles in vertical surfaces of size 300mm x450mm x 7mm thick over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match all as directed. 46 Demolition of Stone slabs and tiles laid, bedded in any mortar of any description or thickness in floors, aprons etc. 47 S&F granite 12-15mm thick of any type ( table rubbed and polished in steps, jambs pillars, window cill, cooking platform and like in cement mortar 1:4 incl pointing in white cement complete all as specified and ditected. 48 Taking down chowkat with shutter n. exc 1.5 Sqm each complete all as specified and as directed . 49 Taking down chowkat with shutter exc 1.5 Sqmbut n.exc 4 Sqm each complete all as specified and as directed . 50 Supply and fix factory made 100 % solid wood plastic composite (WPC) door frame 75x50 mm made from wood plastic composite (single extruded process) material with density 780 Killogram/Cubic meter from ISO certified company door should be water proof, teRunning meterite proof, fire retardant and having good screw holding capacity all as per specification and drawing complete all as specified and directed . 51 Supply and fixing 30 mm thick WPC factory made 100% solid flush designer door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side plain with density not less than 600 Kg/cum.Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire retardant and having screw holding capacity complete all as specified and directed . 52 S&F 200 mm long, solid in one piece stainless steelbarrel tower bolts complete all as specified and directed . 53 S&F 150 mm long, solid in one piece stainless steelbarrel tower bolts complete all as specified and directed. 54 S&F 150mm size solid in one piece stainless steel handles,cast, fixed in stainless steel screwsall as directed complete all as specified and directed . 55 S&F 100 mm size stainless steel butt hinges and fixed with stainless steel screws, complete all as specified and directed by Engr-in-Charge. 56 S&F stainless steel sliding door bolts 204 grade,hasp and staple typewith bright bolt not less than 12mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 250mm long complete all as specified and ditected. 57 S&F in repair peg set of five stainless steel fixed on CP steel plate 304 grade including fixing screw as per approved sample. 58 Dismantling of framed or unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. 59 S&F MSjoist channel (Fe 410-W Gde E-250 Quality A), angle or Tee section,MS tubes, flats square bars etcfixed indepently or framed or without connecting plates ,trusses etc any type framing including purlins and rafters etc confirming to Grade Fe 410-0 or Fe-310-0 complete all as specified and directed. 60 S&F mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; staircase; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 including necessary welding, drilling hole complete all as specified and directed. 61 M&L for two coat of synthetic enamel paint over a coat of primer including preparation onnew steel surfaces ofany description over 10 cm width or girth 62 Preparation of old Steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint all as spd and directed 63 Dismantling of plain or corrugated steel sheeting any guage, thickness including nainital or similar pattern roof coverings complete all as specified and directed. 64 S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.60 mm thick Mangalore parttern of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. 65 S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and profile should match with galvalume sheet complete all as specified and as directed. 66 S&F 1200 mm x 1200 mm x 6 mm thick bevelled edge mirror of selected quality glass,mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. 67 S&F in repairs glass corner shelf suitable size made of 5mm thick toughned glass all as specified. 68 S&F in repair 25 mm dia stainless steel polished 204 grade drapery rod 1mm thick with final decorative, including brackets, decorative finished at both ends completeall as speccified and directed as per approved sample complete all as specified and ditected. 69 S&F in repairs CP brass Soap dish 6 inches complete all as specified and directed. 70 S&F in repair PVC Shelves 450mm of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105 gms) 71 Demolition of reinforced cement concrete, shelves, chajjas, slabs and similar work carefully and matching to adjoining disturbed surfaces all as directed. 72 M&L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and colums, in floors, roofs, landing balconies, canopies, deck slabs, chajja and in shelves and the like, complete all as specified and directed. Note : The work will be carried out upto tripple storey builing the rate of scafolding is included for this item also. 73 M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) forcolumns, pillars, piers, post and strut complete all as specified and directed. 74 M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for foundations, includingf rafts, footings, foundations beams, plinth beams, bases for columns etc complete all as specified and directed. 75 M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in cills, copings, benching on chajjas, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed. 76 M & L forformworktosides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantiliver shelves etc.for fair finished complete all as specified and directed. 77 M & L forformworktosides of pillars, posts, struts, piers, columns and stanchions etc.for fair finished surface complete all as specified and directed. 78 M & L forformworktoedges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed. 79 M&L for mild steel TMT bars 8 mm dia and over cut to length and bent to shape required and binding with mild steel wire dia not less than 0.9 mm (annealed) complete all as specified complete all as specified and directed by Engineer-In- Charge 80 Supply and fixof CPVC pipes outer diameter 25mm, SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceilings or laying in floors including fittings like elbow, tee, etc. including dismantling of old GI tubing complete all as specified and directed. 81 Supply and fixof CPVC pipes outer diameter 20mm, SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceilings or laying in floors including fittings like elbow, tee, etc. including dismantling of old GI tubing complete all as specified and directed. 82 M&L cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10cm girth. 83 Supply and fixing for rotational moulded polyethylene 1000 Ltrs Capacity white water storage tanks of weight not less than 33 kg (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float three layer external and internal white and fly nut complete screwed down for iron pipe of 15 mm dia including dismantling of old tank complete all as specified and directed. 84 S&F in repair ball valve high pressureof PTMT with epoxy coated alum rod & high density plastic ball screwed for 15mm bore iron pipe and fixed ( minimum weight 20mm -210 gms) complete all as specified and directed. 85 S&F in repair CP toilet paper holder as approved by Engr-in-Charge. 86 S&F in repair CP Brass 3 in 1 hot & cold 15 mm dia wall mixer for mixing hot & cold water with telephonic shower provn with connecting legs & flanges complete all as specified and directed. 87 S&F in repair CP brass Central hole basin mixer fancy type 15mm dia all as specified and directed. 88 S&F in repair CP brass bib tap fancy type short body15mm bore screwed for iron pipe or for brass ferrule all as specified in SSR Part I . 89 S&F in repair 15mm bore Bib taps long body, cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. 90 S&F in repair 15 mm bore Angle cock/stop valves (2 in 1), cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. 91 S&F in repair PVC Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified and directed and approved. 92 S&F in repairs 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified. 93 S&F in repair brass chromium platedovehead shower with shower arm complete all as specified and directed. 94 S & F in repairs wash down water closet (EWC) white with P or S trap including Flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern and plastic water closet seat & cover mild steel chromium plated or aluminised hinging device and connection to low level flushing cistern and flush pipe, etccomplete all as specified and directed. 95 S&F of 40mm outer dia of CPVC pipe class 1 on wall /ceiling or laying in floor incl of all fitting i.e elbow,tee and socket etc, complete all as specified 96 S&F vitreous china, white, oval shape wash hand basin, flat size 550 x 400 mm including MS brackets including 12 to 15mm thick prepolished mirror granite fixed on RCC slab 1:11/2:3, 50mm thick with steel reinforcement (paid separately) cutting for and pinning in ends of brackets but excluding Waste pipe & with 32mm (PTMT) waste coupling (half or full threaded) minimum weight 32gm-45gms) & 15mm bore CP pillar tap supply only 25mm dia PVC (LDPE) of pressure 6Kg/cm2 down pipe 75cm long complete all as specified and directed. 97 S&F PVC connection 15mm size with PTMT nuts, of 450 mm length. 98 Taking down AC/Salt glazed warepipes and fittings upto 110mm. 99 S&F in repairs for 100mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and directed. 100 S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls complete all as specified and directed. 101 S&F PVC (SWR) pipes of 75 mm dia, single socketed fixed to walls complete all as specified and directed. 102 S&F PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed. 103 S&F PVC (SWR) bends of 75 mm dia, any radius complete all as specified and directed. 104 S&F PVC (SWR) junction single Tee equal or unequal 110 mm dia complete all as specified and directed. 105 S&F PVC (SWR) junction single Tee equal or unequal 75 mm dia complete all as specified and directed. 106 PVC(SWR) floor trap, plain with grating including jointed with solvent cement of 75 mm outlet dia complete all as specified and directed. 107 S&F in repairs PVC waste pipe not less than 60cm long with PVC coupler for kitchen sink, WHB, urinal, etc complete all as specified and directed . 108 S&F in repair CP steel Grating round with steel frame with hinge 100mm dia all as sample approved. 109 S & F for Anodised aluminium frame for doors, windows ventilators (Powder Coated)with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 110 S&F sheet glass ordinary quality 4mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc. .5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and directed. 111 Supply & fixing for powder coated Aluminium standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter and one nos stainless steel wire gauged shutter sliding type, 3 track numbers for sliding windows, and glazed with glass 4mm thick & including glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum including locking system and provision of space for AC etc complete all as specified and directed by Engr-in-charge.Size of Track-Both Top & Bottom (Verticles sides):- 100 x 44 x 1 mmSize of Shutter Frame:- 25 x 12 x 1 mmNote: Iron grill with frame to be fixed with window (measured and paid separately) 112 Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) 113 M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement and demolition of existing old cement concrete of plinth protection inground floor and paving below or above ground level complete. 114 Dismantling wall and ceiling board,of any description complete all as specified and directed. 115 M & L 595 mm X 595mm false ceiling system , using hot dipped galvanised steel section exposed surface with precoated capping, GI powerd coated tee and cross tee of size 24x32mm & 24x27mm having 0.27mm gauge at every 600mm c/c interval and wall angle of size 19x19mm having 0.35mm gauge fixed to the wall. The above grid is tobe suspended at every 1200mm c/c in both direction using 2mm thick pre-straightened GI wire laying designer tile ivory painted (high pressure steam cured) of 4 mm thickness (as per IS 14862) of size 595x595 mm and ant ine of the design (cascadev or electra) , back of the tile duly sanded and finished with a coat of protective paint over the formed grid etc complete all as specified and directed. 116 Material and labour for point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 sq mm nominal cross sectional area drawn in non rigid PVC concealed conduit not less than 25mm diawith all fitting and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including Modular metal flush boxes 1.6 mm thick, upto 60 mm deep of required size factory made for mounting modular switch, regulators etc with inner /outer cover and frame(white) ISI marked, fixed with brass screwsincluding taking down unsv point wiringof any sizefor the following type . Note: (i)The quoted rates shall be deemed to be inclusive formaking good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. (ii) Point wiring & earth wire shall be connected to each & every sunken box. 117 (a) One light point,controlled by one way switch. 118 (b) One fan point, controlled by one way switch through regulator. 119 (c) One three pin 5 Amp socket on same board with other switches 120 (d) One three pin 5 Amp socket on independent board 121 (e) Description all as per item No 116 here in before but point wiring with 4 sqmm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 4sqmm PVC insulated multi strand copper conductor cable as continous earth wire. 122 Supply and fix modular switch single pole one way, one module, 230 Volts 6 Amp complete all as directed. 123 Supply and fix modular socket 6 Amps, 2/3 pin combined, two module, 230 Volts complete all as directed. 124 Supply and fix modular switch single pole one way, one module, 230 Volts 16 Amp complete all as directed. 125 Supply and fix modular socket 16 Amps, 2/3 pin combined, two module, 230 Volts complete all as directed. 126 Supply and fix modular ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified and directed. 127 Supply and fix energy efficient LED tube light fittings 20 Watts, 230 volts with efficiency of not less than 100 lumens per watt, PC extruded body with PC diffuser including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed. 128 S&F mirror light decorative compact luminarious with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size . 129 S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. 130 S&F decorative wall mounting made out of polycarbonated suitable for and incl retrofit 9 watts LED bulb complete all as specified. 131 Supply, fixing, connecting and testing of35 watt LED building security light luminaries with min 10 KV surge protector die cast alluminium housing LDR sensor for automatic operation complete suitable for and incl bracket 32 mm GI pipe bend to shape incl clamp fastner, bolts, nuts & washers of min 1.2 Mtr incl grouting etc and 3 core 1 sqmm PVC insulated cable from ceiling rose to light fitting complete all as specified 132 S&F Exhaust fan exhaust fan made of steel body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 450mm, complete with louvers, shutters and connecting up ceiling rose to connectorblock of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. Note : Old fan should be deposited to MES store (Test certificate of fan to be submitted) 133 S&F Exhaust fan exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep250 m, complete with louvers, shutters and connecting up ceiling rose to connectorblock of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. Note : Old fan should be deposited to MES store (Test certificate of fan to be submitted) 134 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator (min 100w), Fan hook split type fabricated out of 12mm dia steel bar of length 30 cm duly painted with rod oxide old black paintand all accessories required to connection, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed 135 S & F sub main wiringwithPVC insulated unsheathed FRLSH cable 1100 Volt grade,with multi stranded copper conductor drawing in and including rigid PVC conduit in concealed / surface as required at site including one runPVC insulated unsheathedcable with multi stranded copper conductor colour code as a earth continuity and connected upto DBincluding taking down old unsv submain wiring of following sizes .Note:(i)Tworun of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface withusing PVC rawl plugs etc.(iii) Phasecolour code must be follow i.ePhase( Red) and Neutral ( Black) In colour and for three Phase RYB For phase and black for neutral. 136 2 x 6 Sqmm+ 1 x 6 sqmm 137 2 x 4Sqmm + 1 x 4 sqmm 138 S & F inreplacement Distribution boards epoxy powder coated TP & N (VTPN MCCB DB) fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall with suitable capacityfully insulated copper Bus Bar for each phaseand 02 neutralshroudedbar ,2 earth bar and cable tie for cable managementwith reversible door for IP-43 protection,415 voltand suitable for fixing FP MCCB 100/125 Amps as incomer andcombination of SP/TP MCBs asoutgoings offollowing capacity including taking down old unsv MCCB DB,s.Note: Suitable MCCB and outgoing MCBs will be measuredand paidseparately under relavant items of this schedule. 139 4 Way VTPN DB 140 S & F in replacement MCCB ,4 poleICS=100% ICU at 415 voltswith thermal-magnetic release and adjustable overload settingoffollowing capacity . 141 63 Ampswith rupturing capacity 16 KA 142 S & F inreplacementMCB SP 240 volts B Curve 10 KA . including connection with suitable size copper lugs of following capacity 143 MCB SP 6 to32 Amp.240 volts 144 MCB SPN 40to 63 Amps 240 volts 145 S & F in replacementDistribution box MCB Protected socket with Plastic enclosure (Surface mounitng ) 20 AMP MCB Combo box DP including plug top complete all as specified and directed 146 S & F in replacementMCB DB, sheet metal enclosures double door.The DBs should be supplied with tin platted insulated copper bus bar rated for 100A. 240 volts with IK09 type with blanking plates where required and IP 43 degree protection of following size:- 147 8 way SPNDB. 148 Material and labour for Earthing complete with galvanized ironearth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board andtesting on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc.GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed.Note: (i) Earth lead wire and its protection pipe upto and including 7.5 mtrfrom the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. 149 XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 25 Sqmm 4 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. 150 Sand cushioning to under ground cable, 8 cms thick before laying the cable and 15 cms thick after laying & stretching the cable in trenches, including hand punning and consolidating, complete, all as specified. Note:- For payment purpose punned thickness shall be measured. 151 Bricks, old size sub class `B laid in trenches with width wise along the alignment of the cable as protection complete. 152 S&F tube Light grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed. 153 Supply and fixing LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equiped with IP66 protection with impact and corrosion resistant complete with driver and lamp. 154 XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 16 Sqmm 4 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. (Earth work, brick protection and sand cushioning shall be measured and paid for separately). 155 Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unseviceable LT Cable for laying of cable and getting out. 156 Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection all as specified and directed. 157 Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed . 158 Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified. 159 M&L for brick for laying un-reinforced precast concrete cable coverClass LV, Type I, flat, size 250mm x 150mm x 40mmfor protection of U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exc 10mm over UG cable in trenches all as directed 160 M&L for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed ofsize 40mm dia(make: prakash surya/jindal/TATA) 161 S&F sheet metal enclosures TPN 415 Volt4 way with suitable rated bus bar for double door IP-43DBscomplete all as specified and directed . 162 S&F MCB TPN415 Volt 10 KA63 Amp conforming to IScomplete all as specified 163 S&F MCB SP(single pole) 240 volt 10 KA 5 to 40Amp, conforming to relevant IS complete all as specified & directed. 164 Supply and fixing LED bush light 09 watt , 3000K, efficiancy 80im/w, made with single piece pressure die cast aluminium housing and IP 65 degree of protection suitable for outdoor applicatios like garden , tree uplighting including suitable fixing arrangement complete all as directed 165 M&L for submain wiring with 3 runs(N+P+E) of 2.5 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductorFRLS cable 1100 volts grade drawn throughand including concealed/surfacePVC conduit pipe of medium duty not less than15 mm dia including necessary PVCconduit specials and connecting with suitable size thimble complete all as specified anddirected. Note:-3 runs of2.5 Sqmm size PVC copper cable, and one run of PVC conduit shallbe measured as one unit length. 166 Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equiped with IP66 protection with impact and corrosion resistant complete with driver and lamp. 167 XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 10 Sqmm 4 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. (Earth work, brick protection and sand cushioning shall be measured and paid for separately). 168 M&L for brick well burnt class B as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abuting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches all as specified and directed. 169 S&F SPN 240 Volt 10 KA 40 Amp conforming to IS complete all as specified and directed