Tender For Construction Of New Laboratory Building Near R And D.; 1 Submission of design basis report with detailed calculation using relevant software and submission of reinforcement drawings as per latest, relevant IS codes and certified by chartered structural Engineer. Details as per Sl No 1 in BOQ 2 Engaging portable grass cutting machine for cutting of wild growth of grass, bushes around the QC Lab, R&D, and other locations inside factory premises as directed by engineer in charge.Details as per Sl No 2 in BOQ 3 Earthwork excavation by mechanical means & as directed, in all classes of soil up to a depth of about 2m from the existing earth level & as required to suit site conditions including removing all waste materials, cutting of trees, clearing scraps etc. Details as per Sl No 3 in BOQ 4 Dismantling, chipping, removal of concrete / Rubble masonry / brick masonry etc. Details as per Sl No 4 in BOQ 5 Providing & laying PCC (1:2:4) using 20mm nominal size granite broken stone, machine mixed and properly consolidated with rammers including cost, conveyance of all materials, labour, shuttering work at ends, curing etc. Details as per Sl No 5 in BOQ 6 Providing & laying of Reinforced Cement Concrete RCC (M30 Grade as per IS 456) with a minimum cement content of 380 kg/m3 of concrete by using 20-10 mm downgraded stones, machine mixed, mechanically vibrated, consolidated, curing, including usage of quality material as approved, cost, conveyance, lead, lift of all materials, labour, necessary scaffolding etc. Details as per Sl No 6 in BOQ 7 Supply & Laying reinforcement High yield strength deformed bars Fe 500 grade, cutting to required size, bending, straightening & placing in position, binding with 18/20 gauge black annealed /GI tying wire,including lead, lift of reinforcement to work site, laying as per drawing etc. Details as per Sl No 7 in BOQ 8 Providing centering and shuttering including strutting, propping etc for footings, plinth beams, Tie beam & columns, lintels, sunshade, slab, using plywood with sufficient wooden runners or MS sheets with enough strength to withstand the load of mechanical vibrator during compaction of concrete & it should properly sealed with suitable material to prevent grout leakage from concrete . The removal of formwork is done after reaching the strength of concrete. Details as per Sl No 8 in BOQ 9 Providing masonry work in CM 1:5, using Autoclaved aerated concrete block of required size, laying using cementitious polymer-modified adhesive joint mortar including raking out joints, finishing to proper lines & levels, chipping or hacking the existing floor concrete / columns / beam surface for necessary bonding, curing, etc. Details as per Sl No 9 in BOQ 10 Providing Plastering in CM 1:4, 12 mm thick average in masonry structure by application rough coat first, then finished to required thickness mixing & application one coat neat finish of cement grout with mortar, finishing smooth to proper line & level, fixing button marks, before plastering all construction joints (beam / columns & masonry wall) shall be laid with 110GSM glass fibre mesh cloth of width 1.0m to prevent any cracks, all required for completion of work. Details as per Sl No 10 in BOQ 11 Providing cement mortar beading of width 50mm in edge of sunshades & slab for rain water dropping using CM 1:3, proper line & level to act as a waterproof barrier , includingcost & conveyance of all materials, necessary scaffolding,staging, labour charges etc. Details as per Sl No 11 in BOQ 12 Interior surface ( Premium quality finish paint- Apex Ultima Proteck of Asian paints or equivalent make of BERGER/INDIGO/NEROLAC). Details as per Sl No 12 in BOQ 13 Exterior surface ( Aquagreen WB PU FINWhite –Berger, Nerolac, Asian Indigo). Details as per Sl No 13 in BOQ 14 Providing and fixing 18 mm to 20mm thick mirror Polished, machine cut, good quality granite top, jet black and plain texture laid over the concrete slab / bed, approved shade & finish of required size as suit to site condition, fixing using suitable adhesive, the joints shall be done using epoxy joint filers, mixed with matching pigment, including rounding all the edges & corners, rubbing, curing, proper line & level etc. Details as per Sl No 14 in BOQ 15 Fabrication ,Supply & Fixing of aluminium partition using premium quality profiles to a height of 4.30m from finished floor with 63mm x 38mm x 2mm sections equally divide the length & height according room dimension @ 1 to 1.20m c/c and providing ACP sheetof 6mm thick at bottom & top, etc.Details as per Sl No 15 in BOQ 16 Fabrication, Supply & fixing powder coated aluminium door partially glazed with section size of 80x45mm,1.20 mm thickness, frame of thickness of 60mmx40mm, top portion using 6mm thick clear toughened glass of height about 90cm approx. , bottom portion using ACP sheet of 6mm thick or nearest, joining the section properly, fixing using heavy duty SS hinges of 4 size -4 nos or premium quality pivot type hinge ,handle, lock withkey, premium quality heavy duty door closer shall be fixed with screws/ bolt etc Details as per Sl No 16 in BOQ 17 Supply and fixing of tinted glass double door using 10mm thick toughened glass, (make-Saint gobain or Modi guard) with premium quality floor springs of make Ozone/Geze/Dorma/Hettich, dual swing, suitable to door weight etc. Details as per Sl No 17 in BOQ 18 Fabrication, supply & fixing of powder coated aluminium casementwindow of outer frame size 60mm x 50mm (approx.), thickness 1.6mm, width of shutter 60cm or equally divide the existing opening length, shutter size 80mm x 60mm (approx.), thickness 1.6mm, heavy duty ball bearing hinges, 6mm thick toughened glass (clear/tinted), fixing the windows using screws/anchor bolts, handle, beading to air tight closure using EPDM gasket etc. Details as per Sl No 18 in BOQ 19 Providing and fixing M.S. grills of required pattern in openings of windows with MS Flats (25x6mm), round bars (8mm dia) etc. Details as per Sl No 19 in BOQ 20 Providing & fixing good quality vitrified floor tiles of size 60cm x 120cm or 60cm x 60cm suit to site condition, full body, anti-skid & scratch resistant etc. Details as per Sl No 20 in BOQ 21 Providing & fixing good quality vitrified wall tiles of size 60cm x 60cmor 120cm x 60cm of make: Khajaria/Nitco/SoMany/Jhonson, 8mm thickness of approved design, pattern, shade & finish, to be fixed al-round the wall up to a height of 2.1m, using suitable tile adhesive of 4mm thickness, providing 4mm spacers between the tile joints and filling the gaps using suitable epoxy joint fillers etc.Details as per Sl No 21 in BOQ 22 Supplying, filling, laying & levelling gravelly red earth of good quality as approved, compacting with vibratory rollers, watering and well consolidated properly for heavy equipment movement. Measurement will be taken for compacted layer by actual thickness at site. Details as per Sl No 22 in BOQ 23 Providing suspended false ceiling at a height of about 3.60 m from the finished floor level with powder coated GI section for supports T, C type channels, runners, fittings at regular intervals to prevent sagging, laying aluminium ceiling tile of size 600mm x 600mm, 0.7mm thick /grid panelling, plain shade, off white colour, supported sections fitted to the existing RCC slab, columns, beams Details as per Sl No 23 in BOQ 24 Supply and fixing of PVC pipe 25mm-50mm dia 15 kg/cm2 pressure rating including bends, tees, brass threaded elbows for fixing angle cocks, bib cocks, any other specials required for the work etc. Details as per Sl No 24 in BOQ 25 Supply and fixing of PVC pipe 60-110mm dia of 4kg/cm2 pressure rating including bends, tees, elbows for any other specials required for the work, fixing & sealed with water closet outlet drains etc., sealed with concrete, rain water downtake pipe 110 mm dia from roof slab to ground. Before plastering, leakage testing with suitable working pressure shall be carried out.Details as per Sl No 25 in BOQ 26 Supply and erection of RCCseptic tank of inner size 1.15m width and length 2.50m, capacity 3000 litres with baffle walls / chambers and soak pit, wall thickness of 50mm minimum with necessary manholes cover, soak pit of 1.10m height and 0.90m diameter along with all necessary fittings and accessories.Details as per Sl No 26 in BOQ 27 European water closet (Model No 755 SS) of make – Jaquar or equivalent KOHLER / TOTO). Details as per Sl No 27 in BOQ 28 Half pedestal washbasin (Model No: X801) of make – Jaquar or equivalent of KOHLER / TOTO.Details as per Sl No 28 in BOQ 29 Shower. Details as per Sl No 29 in BOQ 30 Shower cock.Details as per Sl No 30 in BOQ 31 Angle cock.Details as per Sl No 31 in BOQ 32 Bib cock. Details as per Sl No 32 in BOQ 33 Floor trap 8” x 8”. Details as per Sl No 33 in BOQ 34 Health faucet .Details as per Sl No 34 in BOQ 35 Soap tray. Details as per Sl No 35 in BOQ 36 Towel rod 60cm. Details as per Sl No 36 in BOQ 37 Mirror (size- 600mm x 300mm approx.). Details as per Sl No 37 in BOQ 38 Supply and fixing WPC doors suit to existing opening , with door frame of size 100mm x 50mm, fully moulded of single leaf of thickness 28mm, wooden shade, with heavy duty SS hinges of 100mm (4Nos), handles, tower bolts, latch & fixing properly using anchor bolts/ suitable fasteners making it workable condition etc. Details as per Sl No 38 in BOQ 39 Providing & laying factory made cement concrete interlocking paver blocks of M30 grade 80mm thickness made by block making machine with strong vibratory compaction, of approved size, design, shape and colour, laid in required pattern & slope on a bed of 50mm thick 6mm metal granite & M-sand including filling the joints with fine sand, compacting and proper finishing, complete as per direction of Engineer -in- charge. Details as per Sl No 39 in BOQ 40 Supply, fabrication & erection of GI structural hollow tubular sections (Make: Tata structura) for roofing structural works as directed by engineer in charge. Details as per Sl No 40 in BOQ 41 Supply, laying & fixing of colour coated zincalume (aluminium-zinc alloy) roof sheet of thickness 0.5mm (TCT), AZ-150 GSM coating, 550 Mpa tensile strength, for roofing, all accessories such as curves, ridge, industrial trafford profile, including fixing with suitable size SS/ Alloy coated self-tapping screws of size 5.5mm x 55mmfor metal roofing to existing GI purlin, applying weather resistant silicon sealant over the screws etc. Details as per Sl No 41 in BOQ