| 1 | NOTE:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | Lumpsum price workedout by the tenderer for BUILDING& STRUCTURE WORKS as listed in Schedule ‘A’ Part-I |
| 3 | Lumpsum price workedout by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II |
| 4 | Lumpsum price worked out by the bidder/ tenderer forMISC ITEMS - I as listed in Schedule \"A\" Part-III. |
| 5 | Lumpsum price worked out by the bidder/ tenderer forFIRE FIGHTING SYSTEMas listed in Schedule \"A\" Part-IV |
| 6 | Lumpsum price worked out by the bidder/ tenderer forFIRE ALARM SYSTEM as listed in Schedule \"A\" Part-V. |
| 7 | Lumpsum price worked out by the bidder/ tenderer for LIGHTNING PROTECTION as listed in Schedule \"A\" Part-VI. |
| 8 | Lumpsum price worked out by the bidder/ tenderer for AUTOMATIC SPRINKLE SYSTEM as listed in Schedule \"A\" Part-VII. |
| 9 | Lumpsum price worked out by the bidder/ tenderer for ROAD / PATH / CULVERT / HARDSTANDINGas listed in Schedule \"A\" Part-VIII. |
| 10 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule \"A\" Part-IX |
| 11 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule \"A\" Part-X |
| 12 | Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule \"A\" Part-XI |
| 13 | Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule \"A\" Part-XII |
| 14 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule \"A\" Part-XIII. |
| 15 | Lumpsum price worked out by the bidder/ tenderer for DEMOLITION OF BUILDINGS as listed in Schedule \"A\" Part-XIV. |
| 16 | Sch \"A\" Sec-XV (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 siginifies this fact only. |
| 17 | Rough excavation and bringing approved earth (as approved by Garrison Engineer)from sources outside defence land including cost of earth, royality if any, transportation, taxesfor area filling/forming embankments including raising (any height from EGL)/lowering by approved earth and including raising earth spreading in layers not exc 30 cm thick each layer,watering, compaction with 8 tonne to 12 tonne power roller and finished to required size and shape etc,any high from EGL complete all as specified and directed. Note: . (i)Earth required for the item, shall be supplied by contractor, from out side MOD land at his own arrangment. (ii)All cost of procurement of earth including cost of transportation, roualties, taxes etc. shall be deemed to be included in the unit rate quoted by the contractor.(iii)With referance to clause 3.6 of MES schdule Part-II on serial page No 18 it is clarified that measurement of the above item shall be of finalised embankment/traverse of filled earth after consolidation and 10% deduction shall be made from measured and calculated volume to allow for increase in bulk. |
| 18 | S&F LED Bulb 9 Watt ,230 Volt, 50 Hz suitable for batten holder complete all as specified and directed. |
| 19 | S&F LED building security light fitting of 25 Watt, including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece, high pressure die castaluminium alloy, monolithic construction totally enclosed, dust and water proof with minimum IP65 protection as per IS-10322-1982(Part-I) with latest amendments and input voltage range 140-300 VAC, frequency 50-60Hz, P.F should be more than 0.9 with THD(I) less than 10%, cool white color and. Fitting should be provided with min 4 KV surge protection, constant current constant voltage driver, high voltage withstanding capacity upto 300 VAC and also have double phase protection, no load, open circuit and short circuit protection, Light fitting suitable for ambient temperature from minus 10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure minimum IP65 degree protection. The lumen output shall not be less than be 110 lumens per watt, life should not less than 40Khr, color index 6000K and must be certified by the relevant test report Fitting should fixed on pole using and including 1.2m long32 mm or 25mm dia GI pipe light grade bend to shape and fixed using two nos clamps fabricated using MS Flat iron 40x5mm including necessary nut bolts and washers and making all electrical connection complete all as specified and directed |
| 20 | S&F blanking plate suitable for fixing in MCB DB complete all as specifified and directed. |
| 21 | S&F Flameproof rotary switch weatherproof 16 Amps, single pole with separate terminal chamber made in die cast Aluminium alloy LM6 with IP66 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and as directed. Make: Sudhir/ Bharat/ Crompton or equivelent makes. NOTE:5 Nos flame proof lights shall be controlled by one flame proof rotary switch complete all as specified and directed.. |
| 22 | S&F Flameproof switch socket & plug combined, weatherproof 16/20 Amps DP with 3 pin plug top with separate terminal chamber made in die cast Aluminium alloy LM6 with IP66 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and directed. |
| 23 | S&F Flameproof / weather proof MCB Distribution board SPN 10 way made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete with and including internal bus bar & wiring up to terminal complete all as specified and directed. |
| 24 | S&F Surge protection device (SPD) single phase and neutral, 16 KA, T1+T2- limp 8 kA per polefixed in distribution board and making connections complete all as specified and directed. (for flameproof SPN DBs). |
| 25 | S&F Flameproof, weatherproof LED Bulk Head light 30 Watt having flying saucer design with 120 degree beam angle lens , 6500K with 120LM/watt & LED driver made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and directed. |
| 26 | S&F Flameproof, weatherproof LED wellglass light 45 Watt having flying saucer design with 120 degree beam angle lens , 65000 K with 120LM/watt & LED driver made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and directed. |
| 27 | S&F Flameproof, weatherproof LED tube light 1x18 watt 4 feet including tube rode 18/20 watt and cable entries and stopping plugs, made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint shade as per IS:5-631 having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and directed. |
| 28 | M&L for white laminated boards 8 feet x 4 feet including necessary aluminium frame work complete all as specified and directed. |
| 29 | S&F Ready made grass turf (with minimum 5cm of soil covering the grass roots and obtained from any source outside defence land and laid in slope of traverse) complete all as specified and directed. |
| 30 | Supply, laying, connection and testing 400 mm bore, ductile iron pressure pipe centrifugally cast (spun)with spigot and socket ends, class K-9 and confirming to IS 8329 - 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of black bitumen/blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and directed. (For Fire fighting pipe line.) |
| 31 | Supply, laying, connection and testing 200 mm bore, ductile iron pressure pipe centrifugally cast (spun)with spigot and socket ends, class K-9 and confirming to IS 8329 - 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of black bitumen/blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and directed. (For connection to 3 Nos SWTs). |
| 32 | Supply, laying, connection and testing 150 mm bore, ductile iron pressure pipe centrifugally cast (spun)with spigot and socket ends, class K-9 and confirming to IS 8329 - 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of black bitumen/blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and directed. For Igloo & sheds (11 sheds) |
| 33 | S&F CI sluice valve of 400 mm dia, double flanged conforming to IS 14846 PN 1.6 complete all as specified anddirected. (For main pumping line). |
| 34 | M&L for DI fittings for spigot and socketed pipe, such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or socket andpigot) collars, caps and plugs etc upto 150 mm borecomplete all as specified and directed. |
| 35 | M&L for construction of brick masonry valve chamber of size 150cm x 150cm x 120cm (internal dimensions) including necessary earth work in any type of soil, PCC foundation M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work (one and half brick thick) in CM 1:6 with 20 mm thick cement plaster internally and externally in two coats of (12 mm and 8 mm) in cement mortar 1:4, 3 mm thick mild steel cover of structural steel of grade E165 as per IS 15911: 2010 riveted with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel of grade E165 as per IS 15911: 2010, frame welded to base plate of size 150 mm X 12 mm and made of structural steel of grade E165 as per IS 15911: 2010, base plate fixed with 200 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate 50 mm X 50 mm X 6 mm mild steel washer, PCC benching 200 mm thick in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash as per drawing No. TD/EM/6 sheet Nos 1/2 & 2/2 of HQ CE Shillong Zone complete all as specified and directed. |
| 36 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electriccables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade.[Igloo: 50 RM x 10 sheds; ESH- 90 RM x 1 sheds; Interconnections among Igloos 10Nos -380 RM] complete all as specified and directed. |
| 37 | S&F Junction box dia 100 x 65 H dust proof dust tight /totally enclosed type [Igloo: 1 No x 10 sheds; URP: 1 No x 1 sheds;] complete all as specified and directed. |
| 38 | Boring hole under road pavement manually in any type of soil upto 100 m bore complete all as specified and directed. |
| 39 | S&F paddle type flow switchon pipes with welded socket including stainless steel paddle suitable to pipe dia 100 mm to 65 mm including testing and commissioning complete all as specified and directed. |
| 40 | M&L for Loop in loop out cable junction box of FRP weather proof for outdoor installation of size 155 mm x 210 mm x 92 mm suitable for 10-16 Sqmm cable, and having IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit with terminals , combi climate cable glands of IP 66 / 67 for cable entry and grommets IP 65 for conduit for cable exit with and including 01 No. MCB SP 6 Amps, 10 kA,C curve overload and short circuit protection, terminals as PVC connector heavy duty 32 Amps, 4 way for cable necessary fixing arrangements and with cable glands complete all as specified and directed. |
| 41 | S&F street light bracket arm of length not less than 1.5 m made out of GI tubing, 32 mm bore, light grade fied to pole, etc with suitable size flat iron clamp, nuts , bolts including paintng with two coats of aluminium paint over a coat of red oxide, zonc chrome primer on steel surfaces complete all as specified and directed. |
| 42 | M&L for copper strip size 25x3 mm as earth contunity conductor for main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthingas requiredcomplete all as specifed and directed. |
| 43 | M&L for Pre-cast RCC LT cable rout indicator with and including necessary PCC and excavation work for grouting/ fixing of route indicator complete all as specifed and directed. |
| 44 | Boring holes under road pavement by bocky manually in any type of soil upto 150 mm bore complete all as specified and as directed. |
| 45 | Supply, Installation, Testing and Commissioning of Outdoor type RTU based Monitoring / Annunciating cum feeder pillar Control Panel of suitable size made out of 1.6mm thick CRCA sheet. The street light control panel shall be able to monitor and control minimum 90 single phase street lights of upto in the circuit of 30 lights of maximum 63W each and shall consist of the following equipments.(i) RTU shall have (commercial grade) minimum800Mhz processor with 512MB RAM, with suitable Analog Inputs / Outputs and Digital Inputs / Outputs + 20% spare capacity, 02 nos. RS485 communication ports, 1 no. Ethernet port. ModBus and DNP3 compatibility, Aux. supply 24V DC, Program memory backup facility for 180 days, Real time clock, Operating temperature range O to 70·c. with inbuilt GPRS modern (4G enabled with at least 150MBPS speed) with suitable external antenna, capable of sending data remotely and SMS as well; including the cost of communication for 24 months. The RTU shall be NABL certified as per IEC 61010-1 (clause 6.8}-Dielectric and IEC 60255-27 (clause 10.5.3) -Impulse testing. (Make: Schneider, Siemens, GoPower, RightWatts, Regin)The RTU shall have a remote webpage for operation; the remote webpage shall have capability to integrate 50 suchRTUs. The webpage standard design shall be capable of controlling street Lights using a web link over Internet connection. |
| 46 | (ii) SMPS of 230V AC Input, 24VDC output, current rating 10A(iii) Set of Control Relays, if required(iv) I/C: 32 A TPN MCCB - 01 nos, O/G: S 16A SPMCB-3nos.(v) Selector Switchesvi) Push Buttons and LED signalvii) Power contractor of suitable ratings for the street lampsvii) 0.5 sqmm multistranded internal wiring with ferruling suitable lugs.The modem shall be inbuild type and have following features:(i) GPRS Multi-slot GPRS class 10/8; GPRS station class B(ii) Power Class 4 (2 W@ 850/900 MHz) and Power Class 1 (1 W@ 1800/1900 MHz)(iii) QMI and MBIM enabled(iv) Auto restore -time resetNote : The cost of provision for Sim connection & hoistling/ vending software required for communication deems to be included with thequoted rate against thease items |
| 47 | Supply, Installation, Testing & Commissioning of multifunction meters with RS485 for mounting on main distribution panelusing existing current transformers. The meter shall be of acc cl 1.0 and shall be able to record V, A, KW, KWh, PF, F. In addition, All meters shall also be able to record THD (current and voltage) with all wiring cabling, cutting of cabinets, complete all as specified and directed. |
| 48 | Supply, Installation, Testing & Commissioning of LT current transformer of Rishabh/ AE for rating upto 20A suitable for above meter and the street lighting panel, along with all cabling arrangement complete all as specified and directed. |
| 49 | Supply, Installation, Testing & Commissioning of Android App to control and monitor street lighting loops (including OFF/ ON, Status, energy consumption, 20 parameters from multifunction meter) on hourly basis alongwith real time alerts (within 10 seconds) complete all as specified and directed. |
| 50 | Supply, installation, testing and commissioning electrical LT Feeder Pillar Box, outdoor cubical type floor mountedCPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2 mm thick for internal compartment duly powder coated fixed on angle iron pedestal mad eout of 50x50x6mm with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventilation including suitable size of cable entry, copper bus bar suitable for 250 Amps current carrying capacity with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB,s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeves and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 mtr height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal complete all as specified and directed by the Engg-in-charge( Feeder piller box shall be consisting of the following):- (a) MCCB 200 Amps 4 pole 50 Hz 415 volts, Ics = 100 % Icu, with thermal magnetic release having rupturing capacity 25 KA- 1 No. ( As incommer).(b)MCCB 20 Amps 3 pole 50 Hz 415 volts,Ics = 100 % Icu, with adjustable overload setting having rupturing capacity 18 KA- 10 Nos. ( Outgoings).(c)3 Phase digital multifunction meter model \"A\" class 0.5, 5 Amps with relay - 1 No.(d)Indicating lamp 240 Volts LED type - Set of three (RYB). |
| 51 | Supply, installation, testing and commissioning electrical LT Feeder Pillar Box, outdoor cubical type floor mountedCPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2 mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6mm with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventilation including suitable size of cable entry, copper bus bar suitable for 200 Amps current carrying capacity with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB,s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeves and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 mtr height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal complete all as specified and directed by the Engg-in-charge( Feeder piller box shall be consisting of the following):-(a) MCCB 63 Amps 4 pole 50 Hz 415 volts, Ics = 100 % Icu, with thermal magnetic release having rupturing capacity 25 KA- 1 No. ( As incommer).(b)MCCB 20 Amps 4 pole 50 Hz 415 volts,Ics = 100 % Icu, with adjustable overload setting having rupturing capacity 18 KA- 02 Nos. ( Outgoings).(c)3 Phase digital multifunction meter model \"A\" class 0.5, 5 Amps with relay - 1 No.(d)Indicating lamp 240 Volts LED type - Set of three (RYB). |
| 52 | M&L for LLDPE 10 user septic tank designed to carry sewage and sullage water including execavation in any type of soil , PCC (1:4:8) type D2 below foundation,vent shaft,connectioncomplete all as specified and directed |
| 53 | M&Lfor soakage wells excavation, in any type ofsoil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring ofM-25 Concrete, including intercepting chamber, screen chamber made of Brick masonry in cement morter, RCC cover slab in M-25 / SFRC coverinterconnecting pipes of RCC/DWC complete filledwith brick batsof size 1.2 m dia X 3.0 m effective depth complete all as specified and directed. |