| 1 | Excavation in post holes each 0.50 cum getting out, returning filling in layers not exceeding 25cm including watering and ramming and removing surplus earth to a distance not exceeding 50 metre as in soft/loose soil complete all as specified and directed. |
| 2 | M&L for cement concrete (1:3:6), type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed. |
| 3 | S&F for structural steel work Fe-410-W(Gde-E-250) quality-B as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 4 | M&L for Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc Fe 410-W (Gde E-250) quality B complete all as specified and directed. |
| 5 | M&L for Preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed. |
| 6 | S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Roof/valley gutter/ cladding to wall, fixed with self tapping screws as specified.all joints to be sealed by silicone sealant to the satisfaction complete all as specified and directed. |
| 7 | M&L for Cement concretetype B-2, 1:2:4 (40mm graded stone aggregate) 75mm thick for surafce finish complete all as specified and directed. |
| 8 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with gray cement and pigments including 20mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed. |
| 9 | S&F for Mild steel sheet 1.5MM thick 150mm dia eaves gutters, galvanised class 3, half round with rounded edges complete all as specified and directed. |
| 10 | M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 11 | Demolition of brick work built in cement mortar etc complete all as specified including removing of materials obtained from demolition from worksite to outside MD land at any distance complete all as specified and directed. |
| 12 | Demolition of cement concrets (unreinforced) in ground floors and paving of any description not exc 15cm thickness (below or above GL) including removing materials obtaind from demolition from worksite cutside MD land any distance complete all as specified and directed. |
| 13 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete including removing dismantled material from work site complete all as specified and directed. |
| 14 | Taking down chowkhats or frames exc 1.5 sqm eachand n.exc. 4 sqm eachwith shutters (without taking offf shutters from the frames) and making good distubed surfaces including removing disposable materials from workste outside MDland at any distance complete all as specified and directed. |
| 15 | Dismantling timber scantling 40sq cm and over in section unframed work in any position including removing of unserviceable material from work site all as as directed. |
| 16 | Demolitionof reed, latching with bamboo framing single or double, incl battens and plaster or chiken wire complete all as specified and directed. |
| 17 | Dismantling of CGI (corrugated plain etc) sheets in roof covering including removng of unserviceable material from work site complete all as specified and directed. |
| 18 | Taking down chowkhats or frames exc and not exc 1.5 sqm each with shutters (without taking offf shutters from the frames) and making good distubed surfaces including removing disposable materials from workste outside MDland at any distance complete all as specified and directed. |
| 19 | Demolition of cement concrete (reinforced) asin roofs, floors (otherthan GF) beams and smilar suspended work complete all as specified and directed. |
| 20 | Rough excavation in hard /densa soil and removing excavated materials to a distance n.exc 500mts complete all as specified and directed. |
| 21 | M&L for point wiring with 1.5 Sqmm cable PVC unsheathed and insulated copper multistranded conductor(FRLS) 1100 Volts grade cable ( red colour cable to be used for Phase connection and black colour cable to be used for neutral connection)including PVCconduit with all accessories including 1.5 sqmm copper multistrand conductor FRLS 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box made out of MS sheet 1.2 mm thick for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and directed. |
| 22 | Light/Fan/Exhaust fan/Bell point |
| 23 | S&F for ceiling rose 3 phase/PVC/polycarbonate,isolated body,surface type with ISI marked complete all as specified and directed. |
| 24 | S&F for switch piano flush type 5/6 amps, 240 volt single pole one way complete all as specified and directed. |
| 25 | S&F for wall decorative ultra slim LED 18/20 Watt, 230 volts, 50 Hz, 4 feet, lighting fixture with extruded polycarbonate lighting fixture, environmental friendly, energy efficient ready to use pack including lamp complete all as specified and directed.Make : Crompton Cat Part No CCS-102-20-65-SL-DP-MWH. |
| 26 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |