Carriage Of Pcc Pole 8.5 Mtr Long(04 No),A.C.S.R Weasel Conductor(1400.00 Mtr),Stay Set 16X1800 (02 No),Earthing Rod (02 No),11 Kv Composite Poly Pin Insulator (12 Nos),11 Kv Composite Poly Disc Insulator 45 Kn(06 No),Stay Wire 7/10 Swg(17 Kg) Corss Arm V-Type 11 Kv (04 No) And All Other Required Material As Per Estimate , Providing And Fixing Of Hloding Clamp For Pcc Pole (08 No ),F Clamp (04 No ), Nut Bolts (08 Kg) And All Allied Material Arranged By The Contractor , Errection Of 8.5 Mtr Pcc Pole Between Long Span (04 No), Fixing Of 11 Kv V Cross Arm (04 Nos),11 Kv Poly Pin Insulator(12 Nos),11 Kv Polydisc Insulator(06 Nos) , Grouting Of 8.5 Mtr Pcc Pole(04 No) And Recondcuting Of Weasel Conductor As Per Estimate(1400 Mtr) (As Per Respo Norm) , 33/11 , Carriage Of Pcc Pole 8.5 Mtr Long(20 No),A.C.S.R Weasel Conductor(4300.00 Mtr),Composite Poly Disc Insulator 70 Kn B&S(30 No),11 Kv V -Type Steel Cross Arm 65X65x6 Mm(20 Nos),Composite Poly Pin Insulator (60 Nos),Top Chanel (04 No),Stay Wire 7/10 Swg(100 Kg),Stay Set 16*1800( 10 Nos),Earth Rod(10 No),And All Other Required Material As Per Estimate , Providing And Fixing Of 11 Kv F Clamp(20 Nos) Andholding Clamp (20 Nos) ,Nut Bolts (100 Kg) For8.5 Mtr Pcc Pole And All Allied Material Arranged By The Contractor. , Errection Of 8.5 Mtr Pcc Pole Between Long Span (20 No), Fixing Of 11 Kv V Cross Arm (20 Nos),11 Kv Poly Pin Insulator(60 Nos),11 Kv Polydisc Insulator(30 Nos) , Grouting Of 8.5 Mtr Pcc Pole (20 Nos) And Recondcuting Of Weasel Conductor As Per Estimate (As Per Respo Norm) , Grouting Of Stay , Carriage Of Pcc Pole 8.5 Mtr Long(18 No),A.C.S.R Weasel Conductor(4000.00 Mtr),Composite Poly Disc Insulator 45 Kn B&S(18 No),11 Kv V -Type Steel Cross Arm 65X65x6 Mm(18 Nos),Composite Poly Pin Insulator (54 Nos),Stay Wire 7/10 Swg (90 Kg),Stay Set 16X1800 (09 No), T-Off Channel (02 No),Top Channel(02 No) ,Earth Rod 2500X20 Mm (09 No) And All Other Required Material As Per Estimate , Providing And Fixing Of 11 Kv F Clamp(18 Nos) Andholding Clamp (18 Nos), Nut Bolts (80 Kg) For8.5 Mtr Pcc Pole And All Allied Material Arranged By The Contractor , Errection Of 8.5 Mtr Pcc Pole Between Long Span (18 No), Fixing Of 11 Kv V Cross Arm (18 Nos),11 Kv Poly Pin Insulator(54 Nos),11 Kv Polydisc Insulator(18 Nos) , Grouting Of 8.5 Mtr Pcc Pole(18 No)And Recondcuting Of Weasel Conductor As Per Estimate (As Per Respo Norm) , Grouting Of Stay , 3X185 Sq Mm Xlpe 180, Carriage Of Pcc Pole 8.5 Mtr Long(02 No),Tee- Off Channel(02 No),Composite Poly Disc Insulator 45 Kn T&C(06 No), Cable Box O/D 11 Kv 3X120 Xlpe (02 No), Cable H.T. Xlpe 11Kv 3X120 Sq.Mm(58 Mtr),Top Channel (02 No) And All Other Required Material As Per Estimate , Laying Ofxlpe 11Kv 3X120 Sq.Mm Cable (40 M) , Grouting Of 8.5 Mtr Pcc Pole(02 No)As Per Estimate (As Per Respo Norm) , , Carriage Of Pcc Pole 8.5 Mtr Long(04 No),Abc ( 3X50+1X35+1X16) Sq.Mm (0.500Km)And All Other Required Material As Per Estimate , Providing And Fixing Of Eye Hook (04 No), Lt Insulator (04 No) And All Allied Material Arranged By The Contractor , Stringing Ofabc ( 3X50+1X35+1X16) Sq.Mm (0.500Km) , Grouting Of 8.5 Mtr Pcc Pole(04 No)And Replacement Of Abc (3X50+1X35+1X16) Sq Mm As Per Estimate (As Per Respo Norm) , 3X185 Sq Mm Xlpe 200 , Carriage Of Pcc Pole 8.5 Mtr Long(02 No),Tee- Off Channel(02 No),Composite Poly Disc Insulator 45 Kn T&C(06 No), Cable Box O/D 11 Kv 3X185 Xlpe (02 No), Cable H.T. Xlpe 11Kv 3X185 Sq.Mmn (75 Mtr),Top Channel (02 No) And All Other Required Material As Per Estimate , Laying Of Xlpe 11Kv 3X185 Sq.Mm Cable (45 M) , Grouting Of 8.5 Mtr Pcc Pole(02 No)As Per Estimate (As Per Respo Norm) , 3X185 Sq Mm Xlpe 150 , Carriage Of Pcc Pole 8.5 Mtr Long(02 No),Tee- Off Channel(02 No),Composite Poly Disc Insulator 45 Kn T&C(06 No), Cable Box O/D 11 Kv 3X120 Xlpe (02 No), Cable H.T. Xlpe 11Kv 3X120 Sq.Mmn (58 Mtr),Top Channel (02 No) And All Other Required Material As Per Estimate , Laying Ofxlpe 11Kv 3X120 Sq.Mm Cable (40 Mtr) , Grouting Of 8.5 Mtr Pcc Pole(02 No) As Per Estimate (As Per Respo Norm) , 33/11 11 , Carriage Of A.C.S.R Weasel Conductor(1000.00 Mtr),Composite Poly Disc Insulator 45 Kn B&S(09 No),Composite Poly Pin Insulator (18 Nos),And All Other Required Material As Per Estimate , Stringing Of A.C.S.R. Weasel Conductorat Site (1000.00 Mtr Asper Estimate) ,11 3X185 Sq Mm Xlpe 200 Carriage Of Pcc Pole 8.5 Mtr Long(02 No),Tee- Off Channel(02 No),Composite Poly Disc Insulator 45 Kn T&C (06 No), Cable Box O/D 11 Kv 3X185 Xlpe (02 No), Cable H.T. Xlpe 11Kv 3X185 Sq.Mmn (130 M),Top Channel (02 No) And All Other Required Material As Per Estimate , Laying Of Xlpe 11Kv 3X185 Sq.Mm Cable (100 M) , Grouting Of 8.5 Mtr Pcc Pole(02 No) (As Per Respo Norm) , 3X185 Sq Mm 150, Carriage Of Pcc Pole 8.5 Mtr Long(02 No),Tee- Off Channel(02 No),Composite Poly Disc Insulator 45 Kn T&C(06 No), Cable Box O/D 11 Kv 3X120 Xlpe (02 No), Cable H.T. Xlpe 11Kv 3X120 Sq.Mm(58 Mtr),Top Channel (02 No) And All Other Required Material As Per , Laying Ofxlpe 11Kv 3X120 Sq.Mm Cable (40 M) , Grouting Of 8.5 Mtr Pcc Pole(02 No) (As Per Respo Norm) ,3X185 Sq Mm Xlpe 150 Carriage Of Pcc Pole 8.5 Mtr Long(02 No),Tee- Off Channel(02 No),Composite Poly Disc Insulator 45 Kn T&C(06 No), Cable Box O/D 11 Kv 3X185 Xlpe (02 No), Cable H.T. Xlpe 11Kv 3X185 Sq.Mm (58 M),Top Channel (02 No) And All Other Required Material As Per , Laying Of Xlpe 11Kv 3X185 Sq.Mm Cable (40 M) , Grouting Of 8.5 Mtr Pcc Pole(02 No) (As Per Respo Norm) , Gst Extra