| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lif. |
| 4 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Makingplinthprotection 50mmthickofcementconcrete 1:3:6 (1cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of stone aggregate 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : |
| 9 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor fivelevel,excludingcost of centering,shuttering, finishingand reinforcement: |
| 11 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 14 | Foundations,footings,basesof columns,etc.formass concrete |
| 15 | Walls (anythickness)includingattachedpilasters, butteresses, plinth and string courses etc. |
| 16 | Lintels,beams,plinthbeams,girders,bressumersand cantilevers |
| 17 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 18 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 19 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 20 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete above plinth level. |
| 21 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 22 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 23 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 24 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanizedmild steel section madeof requiredshape & size asper CPWDSpecification,uPVC extrudedglazingbeads,interlocksandlnlinesashadaptor(where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:-StructuraldesignproofcheckedfromaGovernment Engineering Institute,tobeprovidedbythemanufacturerfor (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds |
| 25 | Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R2 series with frame (40 mm & above) x (40 mm & above) & sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). |
| 26 | Three track threepanels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R2 series with frame (70 mm & above) x (40 mm & above) & sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). |
| 27 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite)soliddoor/window/Clerestorywindows&otherFrames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywithpropertyofbeingtermite/borerproof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 28 | Frame size 65 x 100 mm |
| 29 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 30 | 35 mm thick |
| 31 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 32 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 33 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 34 | Electric resistance or induction butt welded tubes |
| 35 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 36 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 37 | Ingratings,frames,guardbar,ladder,railings,brackets, gates and similar works |
| 38 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 39 | G.I. pipes |
| 40 | Providing and laying vitrified floor tiles in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 41 | Size of Tile 600x600 mm |
| 42 | Providingand fixingplainmultipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 43 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 44 | Providing and fixing on wall face unplasticisedRigidPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 45 | 110 mm diameter |
| 46 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 47 | Single pushfit Coupler110 mm |
| 48 | Bend 87.5°110 mm bend |
| 49 | 12 mm cement plaster of mix: |
| 50 | 1:4(1 cement: 4 fine sand) |
| 51 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: |
| 52 | New work(twoormorecoats)over andincludingwater thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 53 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 54 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 55 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 56 | Two or more coats on new work |
| 57 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 58 | One or more coats on old work |
| 59 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand andmanufacturerincluding applying additional coats wherever required to achieve even shade and colour |
| 60 | Old work (one or more coats) |
| 61 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 62 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 63 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 64 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50mm (+ 0.05%) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping aluminium screws (Xylan) of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 65 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with aluminium Zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 66 | Barge board (Upto 300 mm) |
| 67 | Providing and laying hollow cement concrete block walling up to floor five level 150 mm thick consisting of hollow block of size 400 x 150 x 200 mm of 1:3:6 (1 cement : 3 coarse sand : 6 stone aggregate 12.5 mm nomial size) laid in cement mortor 1:6 (1 cement : 6 coarse sand). |
| 68 | Providing cement concrete surface drainincluding earthexcavation 10 cm thick base concrete with 1:3:6 ( 1 cement: 3 sand: 6 graded stone aggregate 40 mm nominal size) finished with 1:4 (1 cement: 4 fine sand) including a floating coat of neatcement inside the drain and its top and exposed surface including earth work in excavation and disposed of surplus earth. |
| 69 | 23 x 23 cm surface drain |
| 70 | Providing and fixing plastic foam sheet in shelves including cutting, fixing with necessary nails and screws etc all complete as per the direction of Engineer-in-charge. |
| 71 | 18mm thick plastic foam sheet |
| 72 | Writing building identification name using synthetic enamel paint of suitable colour and brand including required scaffolding etc all complete as per the direction of Engineer-in-charge. |