Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-10-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-10-2025 |
| Sl. No. | Item Description |
| 1 | Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 2 | Dismantling of floorhearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 3 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick cement mortar 1:4 screed bed for laying of floor finishes complete all as specified and directed. |
| 4 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in skirting, dado and risers to steps, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering (backing coat) in cement mortar 1:4 complete all as specified and directed. |
| 5 | Material and labour for coloured glazed ceramic tiles in vertical surfaces 350 x 250 x 7mm/450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering (backing coat) in cement mortar 1:4complete all as specified and directed. |
| 6 | Taking down chowkhats or frames with shutters (without taking off shuttersfrom the frames) exceeding 1.5 Sqm but not exceeding. 4.00 sqm each complete all as specified and directed. |
| 7 | Taking down chowkats or frames not exceeding 1.50 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 8 | Taking down shutter of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each complete all as specified and directed. |
| 9 | Refixing shutter in same opening after repairing, area exceeding 1.00 Sqm but not exceeding 2.00 Sqm complete all as specified and directed. |
| 10 | S & F well-seasoned 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.Note :The rate quoted are deemed to be inclusive ofmaking good to the disturb surfaces to match the existing surfaces. |
| 11 | S&F Pressed steel frames for doors of frame size 125x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and directed.Note : Filling of hollow portion of frames with PCC shall be measured and paid separately. |
| 12 | S&F Pressed steel frames for doors of frame size 105x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and directed.Note : Filling of hollow portion of frames with PCC shall be measured and paid separately. |
| 13 | S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube and fixed as per manufacturer instructions complete all as specified and directed. |
| 14 | S & F 35mm thick 2nd class hard wood factory made plain framed, panelled shutters (any number of panels) with lock rail and panel of 9mm BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces, the size of rails and style as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed |
| 15 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, etc complete all as specified and as directed. |
| 16 | S&F 35 mm thick flush shutter, solid core construction, with block board core and plywood face panels,commercial type on both sides complete all as specified. |
| 17 | M & L for 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass , gauge, etc (without sash bars) , edges of framing plain, chamfered of rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) and fitted to chowkhats complete all as specified and directed. |
| 18 | S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks, or stainless steel wire staples including all cuttings, wastage etc, complete all as specified and directed. |
| 19 | S&F aluminium anodised (powder coated) Three track sliding window frame with shutters with ( 2 Nos glazed and one wire gauzed shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 4 mm thick plain glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc including aluminium grill of thickness 5mm and opening not exceeding 75mmx75mm etc with the following section of frame and shutter complete all as specified and directed:-(a) Sections for shutter:- (i) \"H\" section: 39 x 20 x 1.20 mm thick (ii) \"Interlock\" section: 39 x 20 x 1.20 mm thick(iii) \"Edge & Bottom\" section: 41 x 20 x 1.20 mm thick (b) Section for frame:-(i) Top & Sides: 92 X 29.50X 1.20mm thick(ii) Bottom: 92 X 29.70 X 1.20mm thick |
| 20 | S&F aluminium anodised (powder coated) ventilator frame (section for frame63.5 X 38.1X 1.20mm thick) with shutter(section for shutter 41 x 20 x1.2mm thick)(bottom half portion fixed and top half portion with louverincluding all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 4 mm thick frosted glass to aluminium frame work and louver using rubber gasket and fixed with stainless steel wire cloth of 0.36 mm dia and average width of aperture 1.40 mm outside vent with staple and suitable wall angle of size 25.4 x 25.40 x 1.1mm thick and fillets with screws and washers etc including Deco Grill of Model / Design No. DG 104 and 6.3mm thick etc. complete all as specified and as directed. |
| 21 | M&L for preparation of new wooden surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 22 | S&F 150 mm long extruded aluminium alloy handles, fabricated type, anodizedcomplete all as specified and directed. |
| 23 | S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 24 | S&F 100 mm long extruded aluminium alloy handles, fabricated type, anodizedcomplete all as specified and directed. |
| 25 | S&F 100 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 26 | S&F 300 mm long aluminium alloy, anodised sliding door bolt with hasp and staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast alunimium alloy and fixed complete all as specified and directed. |
| 27 | S&F 100 mm long butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 28 | S & F mild steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 29 | Material & labour for PCCtype C1 1:3:6 (20 mm graded stone aggregate) for filling of hollow frame complete all as specified and directed. |
| 30 | Material & labour for PCCtype B0 1:2:4 (using 12.5mm graded stone aggregate) for fixing hold fasts, angle, etc including necessary form work complete all as specified and directed. |
| 31 | S&F helical door spring of size 300 mm long including roller plate complete all as specified and as directed |
| 32 | S & F in repairs20mm dia tubular decorative curtain rod, brass chromium plated complete all as specified and directed. |
| 33 | S&F in repair brass chromium plated decorative brackets for curtain rod of any size complete all as specified and directed. |
| 34 | S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. including taking out old steel tubing of 15mm bore and connections complete all as specified and directed. |
| 35 | S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. including taking out old steel tubing of 20mm bore and connections complete all as specified and directed. |
| 36 | S&F in repairs 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers compete all as specified and directed. |
| 37 | S&F in repair 10 litres capacityPVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets & flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern & fixing/connecting to pipes complete all as specified and directed. |
| 38 | S&F in repairs vitreous china squatting pan, Orissa pattern of size 580 mm x 440mm white withP or S trap, front or back inlet and integral foot rest (Excluding flushing cistern and flush pipe) complete all as specified and directed. |
| 39 | S&F in repair wash hand basin, white, flat back of size 550 x 400mm excluding pillar taps but including waste coupling, waste pipe and bracket, etc.including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 40 | Demolition of stone slabs of any description or thickness in floors,aprons and wallscomplete all as specified and directed |
| 41 | M&L for Green Marble 18 to 20mm thick(table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble over and including 15mm thick screed bed/bedding layer in cement mortar 1:4 complete all as specified and directed. |
| 42 | Material and labour for 15 mm thick rendering in cement mortar (1:6) onfair faces of brick work or concrete surfaces,finished even and smooth without using extra cement all as specified. |
| 43 | Material and labour for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces in two layers (10mm thick 1st layer + 5mm thick finishing layer) of walls, chajja, fins, facia etc. any height mixed with water proofing compound (for 5mm thick finishing layer only) @ 200 ml per 50 kg of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified and directed.Note: (i) Liquid water proofing compound will be measured and paid separately(ii) Cost of scafolding, any height are deemed to be inclusive in the quoted rate. |
| 44 | Supply only Liquid water proofing compound. |
| 45 | Material and labour for 5 mm thick rendering in cement mortar (1:3) on concrete surface as in ceiling/chajja finished even and smooth without using extra cement complete all as specified and directed. |
| 46 | Material and labour for applying three coats of white wash on ceiling including preparation of new or previously untreated surfaces complete all as specified and directed. |
| 47 | Taking down eaves gutters, sewage lines andrainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swannecks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 48 | M & L for 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in floors complete all as specified and directed. |
| 49 | S & F 110 mm bore PVC (SWR) bends any radius with access door complete all as specified and directed. |
| 50 | S&F for 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal with access door including necessary scafoldingupto any height complete all as specified and directed. |
| 51 | S & F 110mm bore, PVC (SWR) junction single (Single T) equal or unequal with access door including necessary scafoldingupto any height complete all as specified and directed. |
| 52 | M&L for 100mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, including making good disturbed area/surfaces with cement concrete/cement mortar 1:2:4 etc including taking down old unserviceable Nahani/Floor trap complete all as specified and directed. |
| 53 | S&F in repairs 15mm dia Bib tap, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 54 | S&Fin repair 15 mm size stop valve, fancy type, chromium plated with long shank and cup(concealed type), cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union & fixed complete all as specified and directed. |
| 55 | S&Fin repair 15 mm size stop valve, fancy type, chromium plated, cast copper alloy, long shank, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union & fixed complete all as specified and directed. |
| 56 | S&F in repairs 15 mm dia pillar tap, fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and directed. |
| 57 | S&Fin repairs brass chromium plated shower rose 100mm size, including fixing to steel pipe or union complete all as specified and directed. |
| 58 | S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 59 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls etc complete all as specified and directed. |
| 60 | M&L for preparation of new plastered surfaces of walls surfaces and applying two coats of oil emulsion distemper (any colour/tint)over a coat of primer and 1 mm thick wall care putty including rubbing with emery paper to make the wall surfaces smooth and even complete all as specified and directed. |
| 61 | M & L for complete removal of existing wall finishes and treating with two coats of oil emulsion distemper (any colour/tint) over a coat of primer and 1 mm thick wall care puttyincluding rubbing with emery paper to make the wall surfaces smooth and even completeall as directed and specified. |
| 62 | Material & Labour for preparation of new plastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 63 | Material & Labour for preparation of old plastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and as directed. |
| 64 | M&L for preparation of old plastered ceiling surfaces and applying two coats of white wash on ceiling surfaces complete all as specified and directed. |
| 65 | Material and labour for preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 66 | Demolition of cement concrete(un-reinforced) of any description and in anypositionnot otherwise specifically provided for etc complete all as specified and directed. |
| 67 | M&L for treatment to sunken floor of Toilet/Bathroom as in following steps:-i)Top of RCC slab in sunken portion includingperipheral beams shall be plastered with 15mmthick in cement mortar 1 : 3 using approved waterproofing compound @ 3% by weight of cement finished even and smooth using extra cement,curved at the junctions. ii)Apply two coats of epoxy resin/polymer modified cementatious coating like brush bond of FOSROK/SIKA/Pedilite both on floor & beams.iii)Sunken slabs to be given 1:20 slope outward 25mm GI pipe spout with 300 mm projection beyondouter surface of wall shall be provided.iv)Water tightness of sunken portion to be tested by ponding with water for 72 hours. In case of even a slight mark of seepage, the portion to be treated and ponding shall be carried out again to confirm the water tightness of sunken slab. Note : No cutting in roof slab/beam shall be allowed for passing of CI pipes & fittings.The stage of water proofing to sunken slab shall be passed by Eng-in-charge/GE. |
| 68 | M&L for PCC 1:5:10 Type E2 (using 40mm graded crushedstone aggregate) as in filling to sunken floor (upto 04 storey building) complete all as specified and directed. |
| 69 | M&L 25mm thick PCC 1:2:4 Type B-1 ( using 20 mm graded crushed stoneaggregate) as in floor (upto 04 storey building) complete all as specified and as directed. |
| 70 | M&L for 75 mm thick cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection finished fair and even with using extra cement complete all as specified and as directed. |
| 71 | S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed. |
| 72 | M & L for prelaminated particle board 18/19mm thick and fixed as in repair to cup board shutter and shelf, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame works complete all as specified and directed. |
| 73 | Material and labour for taking down of existing roof treatment from roof and terrace, roughening surfaces of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc. and applying roof treatment with the following steps and specifications:- a) Applying crack seal compound of same manufacturer with waterproofing compound to fill all cracks on the roof.b) Applying cement slurry over concrete surfaces @3kg/sqm. c) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound as per manufacturers’ instruction(not less than 3% by weight of cement) on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof (leveling course).d) Applying evenly one coat of primer coating (diluted with water in the ratio specified by manufacturers) (minimum @100-110Sqft per litre (diluted quantity)) on the cleaned plastered surfaces. The surfaces shall be left for air dry for minimum period of 2-3 hours.e)Applying evenly one coat of elastomeric water proof coat in one direction (as specified by manufacturers)(minimum 1 litre per 0.9-1.0 sqm and allow to air dry for 4-6 hours before applying second coat in other direction perpendicular to the first one (as specified by manufacturers) (minimum 1 litre per 0.9-1.0 sqm. The total thickness of two coats shall be 0.5 to 0.6 mm.f) The whole system shall be left for air cure for minimum seven days (without any movement).Make : - Dr Fixit Newcoat Ezee or Berger Home Shield PU RoofKoat or Asian Paints Smartcare Damp Proof.Note : - (i) The waterproofing treatment shall be carried out in the last stage of execution to avoid any damages during the execution.(ii) Payment against this item shall not be allowed till completion of all the stages of work for any slab. (iii) The work shall be executed through Authorized well-trained applicators as per manufacturer’s instructions after obtaining written approval from the GE |
| 74 | Material and labour for complete/partial removal of loose/ cracked concrete including cutting of reinforcement at Single/Double/Triple storey if required from RCC roof projection, chajja, fins, facia etc and applying bonding agent as per manufacturer instruction and making good with RCC (1:1.5:3) type A0 using 12.5 mm graded aggregate in any slab and in any position finished the surface even and smooth with out using extra cement including necessary formwork and welding/binding of reinforcement if required complete all as specified and directed.Notes:-(i) Reinforcement shall be measured and paid seperately under respective item.(ii) The rate shall be inclusive of bonding agent (Fosroc nitobond EP ,Sika hibond, Pidilite 301 pidicrete URP). (iii) The rate shall be inclusive of scaffolding whereever required. |
| 75 | M&L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 76 | S&F in repair PVC connection pipe of size 15 mm dia, 450 mm long with PTMT nuts complete all as specified and directed. |
| 77 | M&L for providing and fixing false ceiling of designer tile ivory/white painted (high pressure steam cured ) of 4mm thick (as per IS: 14862) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms/sqm both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 15x32mm made of 0.3mm sheet 1200mm long spaced between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width including taking down old false ceiling board of any description alongwith rails and connecting items at any heights complete all as specified and directed. |
| 78 | Dismantling AC/CGI/PPGI corrugated or semi corrugated sheets in wall cladding or roof coverings and hanger doors including ridges and make good for aluminium earthing strips after fixing of sheets complete all as specified and directed. |
| 79 | S&F pre-painted galvalume aluminium zinc coating PPGL based corrugated/Trapezoidalsteel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 80 | S&F Pre- painted galvalume aluminium zinc coating PPGL based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, eave board, fixed with self tapping screws, complete all as specified and directed. |
| 81 | Dismantling wrought iron or mild steel work of any description nottherwise provided for complete all as specified and directed. |
| 82 | S&F steel work in tubular vertical post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 gradeSt.-240 complete all as specified and directed. |
| 83 | Supply and fixing of rotational moulded, multilayer HDPE water storage tank of 500 litres capacity( tripple layer wall construction , Cylindrical vertical with closed top)ISI marked hoisted and fixed in position all as specified in SSR Part I including 02 Nos 20 mm bore full threaded GI nipple of required size including ball valves 20 mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm - 210gms including refixing of inlet, outlet & over flow pipe etc and 20 mm bore gun metal, glove or gate valves ISI marked with iron wheel head, screwed both ends for iron pipe and fixed etc including dismantling of existing tank and removing from the site complete all as specified and directed. |
| 84 | Dismantling boarding of any description, fixed in any position with nails complete all as specified and directed. |
| 85 | Material and labour for 2nd class hard wood boarding 20mm thick clean sawn planed one side with butt joints, supplied & fixed with nails in any situation or as in eaves board(except flooring and skirting) complete all as specified and directed. |
| 86 | M&L for preparation of old steel surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed |
| 87 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed. |
| 88 | Material and labour for hard core with broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, wateredand rolled/ rammed to a true surface complete all as specified and directed. |
| 89 | Material and labour for acid resistance ceramic tiles (Industrial type) as confirm to IS 4457 with chemical reistant mortar of size 300mm x 300mm x 8-10mm thick, suitable for hi-turf external tiles, anti skid, scratch resistance and neutral to UV rays and acid/alkali resistance as in floor over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 90 | M&L for 75 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and as directed. |
| 91 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.00 kg of cement per sqm complete all as specified and directed. |
| 92 | M&L for machine cut kota stone slab flooring 18-20 mm thick over and including 20mm thick cement screed bed in CM 1:6,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed |
| 93 | M & L for machine kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick backing coat in cement mortar (1:3) including demolition of existingkota stone slab and cement mortar bedding (but not backing),and removing from site and rubbish of the premisses complete all as specified and directed. |
| 94 | Demolition and breaking up drain pipes 150mm bore (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 95 | Supply & laying Double wall corrugated (DWC) HDPE pipe of 150mm bore (SN-8), thickness greater than 1.30 mm, single socketed in any length with rubber ring joints, laid in trenches orfixed in floor complete all as specified anddirected. |
| 96 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150 mm dia of pipe complete all as specified and directed. |
| 97 | M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:3:6 type C2 for 150 mm bore of pipe complete all as specified and directed. |
| 98 | Cleaning of all debris/vegetation over roof surfaces of non-accessible roof portion(any height) and from the mouth of rain water pipeand around the tanks area and removal of materials out side the MOD land including necessary scaffolding and safety measures complete all as specified anddirected. |
| 99 | S&F in repairs kitchen plate rackmade of stainless steel sheet not less than0.63mm thick of size 760 mm X 610 mm X 250 mm including high quality steel hooks for hanging the utensils complete all as specified and directed |
| 100 | Taking down carefully old unserviceable copper/aluminium point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. to be measured separately) and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as specified and directed by the Engr-in-Charge. |
| 101 | Material and labour for concealed point wiring for One light/fan point controlled by one,one way switch, with 1.5 Sqmm single core, PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through and includingPVC conduitsincluding necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth continuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3 mm thick complete all as specified and directed.Note:-Rate forCutting, chiseling and making good the existingsurface for complete concealed wiring is deemed to be included in quoted rate. |
| 102 | All as per Sr. Item No. 101 herein-above but for One 3 Pin 5 Amps socket out let point onindependentboard. |
| 103 | All as per Sr. Item No. 101 herein-above but for One 3 Pin 5 Amps socket out let point on same board alongwith othersuitable switchs. |
| 104 | All as per Sr. Item No. 101herein-above but for light point controlled by two, 2 way switch |
| 105 | All as per Sr. Item No. 101 herein-above but for bell point controlled by one push button switch. |
| 106 | All as per item No 101 here-in-before but using 2.5 sqmm PVC FRLS insulated copper conductor wire for connecting 15A socket on independent board complete all as specified and directed. |
| 107 | S&F switch piano flush type 240 Volts 5 Amps, SP, one way complete all as specifed and directed. |
| 108 | S&F switch piano flush type 240 Volts 15 Amps, SP, two way complete all as specifed and directed. |
| 109 | S&F bell push piano flush type 240 Volts 5 Amps, one way complete all as specified & directed |
| 110 | S&F switch socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) in independent board complete all as specified and directed. |
| 111 | S&F socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) on same board complete all as specified and directed. |
| 112 | S&F switch socket out let combination multipurpose 3 pin, 5/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) in independent board complete all as specified/directed. |
| 113 | S&F ceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals complete all as specified and directed. |
| 114 | S&F ceiling fan regulator electronic,Deluxe,rotary, step type, 120/280 V complete all as specified and directed. |
| 115 | Supply and install new metering board powder coated Single door fabricated with 1.6 mm thick CRCA sheet suitable for mounting5 Nos MCB 6 to 32 Amp & 01No of TPN MCB with IP 43 protection, Glazed door with fixing four energy meter and provn of bus bar of capacity 150 Amp with locking arrangement of size not less than 75cmX75cmx15cm including taking down of old unserviceable TPN or meter box and making good the disturbed surfaces to match the existing complete all as specified and directed. |
| 116 | S&F in repairs MCB SPN DB 8 waydouble door,IP 43 protection, Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09 complete all as specified and directed. |
| 117 | S&F MCB TPN 63 Amps \"C\" series 10 Ka, 240 volts including taking down old unserviceable MCB completeall as specified and directed. |
| 118 | S&F MCB SPN 40 Amps,10 Ka, 240 voltscompleteall as specified and directed. |
| 119 | S&F MCB SP 6 to 20 Amps, 10 Ka, 240 volts completeall as specified and directed. |
| 120 | S&F Bulb holder angular PVC/Polycarbonate suitable for batten fittingscomplete all as directed. |
| 121 | S&F LEDBatten fitting 1x18watts including tube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and includingprovision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23.0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting complete all as specified and directed. |
| 122 | S&F LED light fitting 1x9W/1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 123 | Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to earth lead wire 4 mm dia by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execuation and earth works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I complete all as specified and directed. |
| 124 | Material & labour for sub main wiring with two runs of single core, FRLSH 6 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn through and including PVC casing caping of adequate size fixed on surfafce of wall/ceiling with all necessary fittings and accessaries and one run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 4 sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking out the old sub main wiring along with damaged casing caping from wall or roof or floor and making good disturbed surfaces complete all as specified and directed.Note : Two run of 6 Sqmm cable, one run of casing caping and one run of 4 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run. |
| 125 | S&F round shape 12 watt (Warm White)220 volts AC wall mounted type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 126 | S&F LED building security light fittings in aluminium PDC housing, toughened glass cover, individual LEDs with secondary optics, covered with IP66 protection with inbuilt surge protection of minimum 5KV and of capacity 35/36 W with and including 32 mm dia GI tubing light grade bracket over all 1.2 m length with cutting as required and bend to shape with flat iron clamp of size 32 mmx4mm-02 Nos, suitable size of nut bolts and washers complete |
| 127 | S&F Geyser 25 ltrs capacity5 Star rated single phase 230 volts 50 Hz ,2 KW including required number of bolts, nut, grouting/plastering arrangement to fix the geyser properly & safely on wall, Note: The cost of necessary grouting/nuts, bolts, PCC, Making good etc. shall be included in quoted rate. |
| 128 | M&L for cutting of circular hole in any type of wall suitable size for fixing of exhaust fan of size 300mm sweep, grouting 04 Nos 100mm long 12mm dia stud bolt including making good to disturbed surfaces of wall to match as per the existing colour complete as directed and specified |
| 129 | S&F exhaust fan, metallic body AC single phase, 230V of size 300mm sweep with, blades, frame and louvers complete all as specified and directed. |
| 130 | S&F in repair ofceiling fan 1200 mm (minimum) sweep, BEE 5 star rated with BLDC technology, AC single phase 230 volt, without remote Suspended from fan hook and including electrically connecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 sqmm copper conductor from ceiling rose to ceiling rose/fan complete all as specified and directed. Note:- Old unserviceable ceiling fans shall be deposited to MES store. |
| 131 | Material & labour for Sub main wiring with two runs of single core, FRLSH 1.5 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn through and including PVC casing capping of adequate size fixed on surfafce of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 1.5 sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking out the old sub main wiring two run of 1.5 Sqmm cable one run of conduit and one run of 1.5 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed. |
| 132 | S&F Calling bell, Ding Dong, AC 230 volts, single pole complete all as specified and directed. |
| 133 | S&F RCBO with earth leakage, over load and short circuit protection, DP, 240 Volts, 32 Amps, 30 mA senstivityincluding taking down old one complete all as specified and as directed. |
| 134 | S&F LED bulb of 6 Watt (Warm white) complete all as specified and as directed |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail