Tender For Spl Repair To Jco Living Bldg At Zangli Under Ge 874 Ews; 1 Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed. 2 M&L for brick work with sub class B old size brick straight or curved on plan etc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. 3 Dismantling floor, hearth or wall tiles including cement mortar bedding complete all as specified and directed. 4 Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. 5 M&L for cement concrete type B-1,1:2:4 (20mm graded aggregate) 50 mm thick as in sub base for floor finishes complete all as specified and directed. 6 M&L for light colour glazed ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. 7 All as per item No 6 above but on vertical surface such as skirting, dados, risers to steps, etc., set and jointed in neat cement slurry and pointed in coloured cement to match tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. 8 M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes complete all as specified and directed. 9 M & L for Ist or premium quality and standard quality of glazes, ceramic “coloured” tiles ofsize 450x300x7 mm thick as in vertical surface suck as skirting/dado etc set and jointed in neat cement slurry and pointed in white or colour cement to matchover and including 10mm thick screed bead in CM (1:4) as in backing coats etc complete all as specified and directed. 10 M&L Cement concrete 1:3:6 type C1 20mm graded stone aggregate asbed block to hold fast block and other similar works etc 11 M&L for PCC, (1:4:8)type D-2 using 40mm graded stone aggregate as in foundation filling, and mass concrete complete all as specified and directed. 12 M&L for 75 mm thick PCC (1:3:6), type C-2, using 20mm graded stone aggregate as inplinth protection/path finished even and smooth without using extra cement complete all as specified and directed. 13 M & L for machine cut mirror polishing Kota stone slab flooring 20-25mm thick over cement screed base 20 mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. 14 M &L for mirror polishing Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over and including 15 mmcement screed in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. 15 Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. 16 M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 17 M&L for pre- painted galvalume aluminum zinc coating GI based plain sheet 0.63 mm thick of an colour having tensile strength of 550 Mpa as in ridge, roof covering/cladding to wall, formed in shape of water channel fixed with self tapping screwscomplete all as specified and directed. 18 Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness including cover fillets complete all as specified and directed. 19 Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed. 20 S & F for clean sawn 25mm thick 2nd class softwood with butt joints boarding, fixed with nails in facia any situation complete all as specified and directed. 21 Resecuring or easing and adjusting the shutters without taking down in the same opening n exc 1 Sqmeach complete all as specified and directed. 22 Taking down shutters exc 2 sqm eachand refixing in the same opening including resecuring or easing and adjusting and also refixing builders hardware, cutting to size and fitting complete all as specified and directed. 23 Taking down shuttersn exc 1 sqmeach and removing from site complete all as specified and directed. 24 Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but n exc 4 sqm each and removing from site complete all as specified and directed. 25 Taking down chowkats with shutters (without taking off shutters from the frame) n exc. 1.50 sqm each & removing from site complete all as specified and directed. 26 S & F solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube, edges will be painted to match with printed sheet as per specification & drawing complete all as specified and directed. 27 S & F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. 28 S&F40 mm thick factory made flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. 29 S&F factory made plain framed, panelled shutter 35mm thick made of 2nd class soft wood of 35 mm thick (two panels) with lock rail and panel of 12 mm veneered particle board with commercial veneering on both faces.The size of rail and styles as per IS: 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed. 30 S&F 30mm thick glazed and skeleton shutters for window & ventilator open rebated and prepared to receive gauze etc (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred breads for securing glass etc sizes of members of shutters as specified in SSR Pt-I Sec 8 Clause 8.24 (b) in 2nd class soft wood complete all as specified and directed. 31 S & F factory made solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes 19mm for top and bottom rails. MSframe shall be covered with heat moulded plain colourPVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as shown in SSR Part – II 2004 and as directed by GE. 32 S&F 75 mmsizebutt hinges cast brass, medium weight, with mild steel hinge pin , bright polished and fixed , type B-11 complete all as specified and directed. 33 S&F 100 mm size stainless steel butt hinges, medium weight, cold rolled etc complete all as specified and directed. 34 S&F 100mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed. 35 S&F 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed. 36 S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed. 37 S&F 300 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete all as specified and directed. 38 S&F 200 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete all as specified and directed. 39 S&F 125 mm size stainless steel butt hinges, medium weight, cold rolled etc complete all as specified and directed. 40 S & F in repair floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel spring fixed in floor with over all (length of cover plate 140 mm) complete all as specified and directed. 41 S&F Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. 42 S&F in repair galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. 43 S & F in repairs Door closer aluminium(extruded section only) hydraulically regulated, designation No. 2,universal type, suitable for door shutters of 750 to1200 mm in width and of weight between 36 to 60 kg and fixed 44 Hacking out old broken glass any thickness size, quality or description from wooden/steel frames fixed with wooden beads/metal pinning and S&F 3 mm thick sheet glass in squares not exc 0,5 sqm in each pane fixed with wooden beads or putty (in metal frames etc), complete all as specified and directed. 45 S & F 3 mm thick plain sheet glass ordinary quality and glazing with oil putty or wooden beads in square area not exc. 0.5 Sqm in each pane complete all as specified and directed. 46 Taking down cement plaster on brick wall, ceiling or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed. 47 M & L 10 mm thick rendering on brick work or concrete surface in cement mortar 1:6 mixed with water proofing compound, complete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately as supply only. 48 M & L 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4 mixed with water proofing compound, complete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately as supply only. 49 M&L for 5mm thick rendering in cement (1:3)on fair faces of concrete surface with finished surface even and smooth in ceiling/ RCC water tank & sunshade, chajjas etc complete all as specified and directed . 50 M&L for preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. 51 Supply only integral water proofing compound. 52 M&L for applying acrylic wall care putty on internal or external surfaces of walls/ceilings /RCC walls (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed. Notes : (i) The prepared surface after wall putty, the contractor will inform to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the Engineer-in-Charge through site order. 53 M&L for complete removal of old decorated plastered or unplastered surfaces of wall, ceiling including cornices, pilastered etc. by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salt andtrading oil and greasy spots including filling depressions of scrapped surfaces and applying two coats of oil bound distemper, over and includingwithpreparation ofplastered surfaces complete all as specified and directed. 54 Material & Labour for Preparing new plastered/ unplastered surfaces of walls and applying two or more coats of 100% Premium acrylic emulsion painthaving VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqmincluding necessary scaffolding complete all as specified and directed. 55 M & L applying two coats of synthetic enamel paint on oldwooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed. 56 S&F 110mm bore, PVC (SWR) pipes, single socket in any length, with rubber ring joints fixed on walls complete all as specified and directed. 57 S&F 110mm bore, PVC (SWR) pipes, single socket in any length, with rubber ring joints laid in trenches or in floors complete all as specified and directed. 58 S&F 75 mm bore, PVC (SWR) pipes, single socket in any length, with rubber ring joints fixed on walls. 59 S & F PVC (SWR) bends any radius, 110mm bore complete all as specified and directed. 60 S & F PVC (SWR) junction Double T (equal or unequal), 110 mm bore complete all as specified and directed. 61 S & F PVC (SWR) junction single T (equal or unequal) with access door any radius, 110mm bore complete all as specified and directed. 62 S & F PVC (SWR) junction single T (equal or unequal) with access door any radius, 75 mm bore complete all as specified and directed. 63 S & F PVC (SWR) junction double T (equal or unequal) with access door any radius, 75 mm bore complete all as specified and directed. 64 S&F in repair 40mm unplasticized PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed. 65 S & F PVC (SWR) bends with access door any radius, 110 mm bore complete all as specified and directed. 66 S & F PVC (SWR) bends any radius, 75 mm bore complete all as specified and directed. 67 S & F PVC (SWR) vent cowl with 110 mm bore complete all as specified and directed. 68 S & F PVC (SWR) reducers 75/110 mm bore complete all as specified and directed. 69 S & F PVC (SWR) Couplers 75/110 mm bore complete all as specified and directed. 70 S & F in repair vitreous China wash basin with pedestal, white, flat back, size 550 x 400 mm with capstan heads, chromium plated,one No PVC waste pipe 25 mm dia and 75 cm long with 32 mm dia connector, 32mm size waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange end, bedded in red lead cement and other fixer complete including cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed. 71 S&F in repair vitreous China squatting pan ORISSA pattern size 580mmx440mm, white with integral foot rest including PVC P or S trap and connection to trap including cement concrete, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor, complete all as specified and directed. 72 S &F in repair 15 mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. 73 S & F in repairs cabinet mirror of size 450x350mm made with 5mm thick PVC sheet coloured or white and fixed to wall complete all as specified and directed. 74 S&F in repairs PVC connection 600mm long with check nut etc complete all as specified and directed. 75 S&F in repair grating doom round 100 mm dia of CP (minimum weight 100 gms) complete all as specified and directed. 76 M&L for curtain rails, stainless steel, with fixing brackets, stops, rollers etc complete all as specified and directed. 77 Taking up or down 15mm steel tubing and connections complete all as specified and directed. 78 Taking up or down 20mm steel tubing and connections complete all as specified and directed. 79 M&L for galvanised steel tubes medium grade 15 mm dia fixed to wall or ceiling or laid under floor, complete with necessary fittings all as specified and directed. 80 M&L for galvanised steel tubes medium grade 20 mm dia fixed to wall or ceiling or laid under floor, complete with necessary fittings complete all as specified and directed. 81 S&F in repairs 15mm dia chromium plated fancy typebib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. 82 S&F in repairs 15mm dia chromium plated fancy type concealed Stop valves/angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 83 S&F in repair stainless steel Soap dish, fixed to plugs with chromium plated brass screws complete all as specified and directed. 84 S&F in repair 10 litres capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. 85 S&F in repairs Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union 125mm size complete all as specified and directed. 86 S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. 87 Supply & Fixing in repair in position, 6 mm thick E board (classic) of size 610x610 mm as in false ceiling fixed with aluminum snap grid frame work of same size as aluminum Tee of size 25x25x1.50mm as main runner, 25x25x1.25 mm thick aluminium Tee as cross runner and aluminum angle of size 25x25x1.25mm at the perimeter including GI 3 mm adjustable suspender of required length of any description complete all as specified and directed. 88 Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed. 89 S & F 410 -W (Gde-E-250) quality-A, rolled steel section as in main and cross beam hip and jack rafter, purlins where connected to common rafter and running rails including distance pieces, cleats etc. complete all as specified and directed. 90 M&L for mild steel framed work for such as grills, gratings, etc.with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming toFe.290.Gde-E-165 complete all as specified and directed. 91 S&F in repair rotational moulded HDPE water storage tanks (cylindrical vertical with closed top) of 250 litres capacity, ISI marked, double layered hoisted and fixed in position including connecting up pipes including ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 20 mm bore size (minimum weight 210gms) complete all as specified and directed. 92 M&L for cement concrete bed of cement concrete 1:4:8 Type D2 to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete complete all as specified and directed. 93 S&F PVC (SWR) pipes 150mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. 94 Treatment of sunken floor slab comprises of the following specifications and all as specified :- 95 (i) M&L for Demolition/cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely.40mm thick average PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout. 96 (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with liquid water proofing compound @ 200ml per 50 Kg beg of cement consumed.Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out (fixing of nozzle and grouting & WPC will be measured and paid separately). 97 (iii)All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. 98 (iv)After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. 99 (v) M&L for applying two coats of polymer modified Cementous water proof coating as per manufacturer instruction to bottom and vertical sides up to finished floor level+100mm height.The thickness of two layer shall be 1mm.When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion complete all as specified and directed. 100 (vi)GI pipe 50mm dia medium grade 50cm long laid on each sunken floor as spout complete all as specified and directed. 101 (vii)Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with liquid water proofing compound @ 200ml per 50 Kg beg of cement consumed as per manufacturers specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured and paid separately) 102 (viii)Allpipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 type C-1 all round after painting with anti-corrosive paint. 103 (ix) After above process, sunken portion shall be filled with PCC 1:5:10 completely and 40 mm thick PCC 1:3:6 shall be provided at the top surface. 104 Note :-(i) Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is included in the rates quoted above. (ii) All debris obtained from site will be thrown away out side MD land by contractor at his own expense. (iii) For payment purpose the plan area of sunken floor shall be taken into accounts. 105 S & F in repair gun-metal, globe or gate valves of 15/20mm dia, with iron wheel head, screwed both ends for iron pipe and fixed etc complete all as specified and directed. 106 S&F in repair 75 mmPVC (SWR) floor trap, plain with grating including jointing with solvent cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) complete all as specified and as directed. 107 Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed. 108 M&L for Pre cast Reinforced cement concrete type B-1 1:2:4 cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and directed. 109 M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. 110 M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.. 111 M&L for excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspit, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out.in soft/Loose soil complete all as specified and directed. 112 M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.in soft/Loose soil complete all as specified and directed. 113 M&L for removing excavated material/soiln exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 114 Dewatering/pumping/bailing out contaminated with waste material sludge from septic tank along with inlet outlet chamber of any capacity/depth by vehicle mounted sewage suction machine and disposing same out of cantonment area in a closed container including taking off manhole cover and putting back the same after cleaning./removing the liquid waste material of septic tanks and cutting hole through slab/ wall where required for inserting pipe and making good the same with cement mortar to match with existing surface to make hygienically fit, writing the date of cleaning of septic tank with black and white paint of size 150x 200 mm and finally spraying un slaked lime (bleaching powder) dry around and over the septic tank all as directed and to the entire satisfaction of GE. 115 M&L for construction of Soakage well, of size 2.4 m dia at bottom and 3 m effective depth complete all as specified and shown on drawing No. CESZ-TD-/2015 sheet No 1/3 & 3/3 dated 22 Feb 2015 (Revised dt 21 Mar 2015) and specified in particular specifications. 116 Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., complete all as specified and directed. 117 M&L for chequered cement concrete tiles of size 20 cm x 20cm and 25 mm thick (in any colour & shape), set, jointed and pointed in neat cement slurry in floors with grey cement & no pigment over 20 mm screed bed in CM 1:6 complete all as specified & directed. 118 M&L for mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; handmade sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. 119 S&F in repair rotational moulded HDPE underground water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, ISI marked, three layered hoisted and fixed in position including connecting up pipes) complete all as specified and directed. Underground water storage tank with following:- respective capacity 01 Piece, First flush system 01 Set, Gravity Filer 01 PC, Delivery pipes 25mm size 15 mtr, Down take pipes 100mm size 15 mtr 120 M&L for applying roof treatment on top of roof with APP based polymericmembrane (not less than 3mm thick , weight not less than 3.5Kg per Sqm, reinforced with polyester non-woven fabric ( weighting not less than 150 gm/ Sqm )laid by torch application method with side overlap 75mm and on end 100mmas per manufactures instructions over a coat of hot paving bitumen of grade 30/40 conforming to IS 73 @ 1.2 Kg/ Sqmover a coat of bituminous primer conforming to IS -1984 @ 0.40 Kg /Sqm and applying two coats of aluminium paint over APP membrane over and including 15mm thick plaster in cm 1:4 using liquid WPC as per manufacture instruction over RCC roof complete all as specified and directed 121 M&L for cutting chases, pinning in brick/Stone walls, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed 122 M&L for lagging on pipe of internal dia 15/20mm used in internal water supply or plumbing all round with, 40 mm min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9843 complete all as specified and directed. 123 Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings, removing material from site for taking credit etc and making good disturbed surfaces of wall, floors complete all as specified and directed. 124 M & L for point wiring One light /one fan/one bell point controlled by one switch, with PVC insulated unsheathed single core multistranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLSH, drawn through PVC casing caping/PVC conduit pipe 20mm dia (as per site requirement) including accessories and provision of PVC boxes for mounting switches, switch socket, fan regulator as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) earth wire and connected to earth dolly complete all as specified and directed. 125 As per Item No 114 above but point wiring for One socket outlet 5 pins 5 amps controlled by one switch on same board . 126 As per Item No 114 above but point wiring One socket outlet 5 pins 5 amps controlled by one switch on independentboard. 127 All As per Item No 114 herein before but wiring with 2.5 sqmm copper wire (FRLS)and 2.5sqmm earth wire for socket outlet 6 pin 15 amps on independent board. 128 S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed. 129 S&F socket outlet multi 5 pins 6 amp,complete all as specified and directed. 130 S & F switch socket combination 2 in 1, 6A flush type complete all as specified and directed. 131 S & F switch socket combination 3 pin 16A, flush type complete all as specified and directed. 132 S&F ceiling rose, PVC/poly carbonate, isolated body three terminal complete all as specified and directed. 133 Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 134 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 135 S&F lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wallfitting complete all as specified and directed. 136 Supply and fix LED Bulb 9 Watt complete all as specified and directed. 137 S & F in repair distribution boards VTPN, 4 way, double door 415 volts 50 Hz ,ACincluding fixing on suitable rectangular block complete all as specified and directed. 138 S & F in repair MCCB ,200 Amp, 4 Pole breaking capacity 16KA, 415 Volt, 50 Hz with sheet metal enclosure complete all as specified and directed. 139 S&F sheet metal enclosure for DBs (double door type) when MCBs to be used single pole and neutral 8 way including blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche including taking down old one complete all as specified and directed. 140 S&F sheet metal enclosure for DBs (double door type) when MCBs to be used single pole and neutral 4 way including blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche including taking down old one complete all as specified and directed. 141 S&F MCB single pole & neutral 40 to 63 Amps 230 Volt C series, 10 KA complete all as specified and directed. 142 S&F MCBs single pole 240 volts 6 to 32Amps 10 KA C series complete all as specified and directed. 143 Supply and fix in replacement, water heater storage type, electric capacity 25 ltr along with all accessories BEE 5 star rated complete all as specified and directed. 144 Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. 145 M & L for sub main wiring with two single core 6 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor FRLSH ISI marked drawn into & including medium grade PVC conduit/ casing caping25 mm dia with all fittings and accessoriesand one continuous run of 6 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed concealed/ surfaceincluding taking down old unserviceable submain wiring and making good disturbed surfacecomplete all as specified and directed. 146 M & L for sub main wiring with two single core 2.5 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor FRLSH ISI marked drawn into & including medium grade PVC conduit/ casing caping25 mm dia with all fittings and accessoriesand one continuous run of 2.5 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed concealed/ surfaceincluding taking down old unserviceable submain wiring and making good disturbed surface complete all as specified and directed. 147 S&F buildingsecurity light fitting in repair LED 35 Wattfor Energy saving and environmental friendly long life made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07 including driver unit and bracket made up of GI tube of suitable size (1.2 Mtr Length)etc complete all as specified and directed. 148 M & L forearthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mmthick buried directly in ground (earth pit not less than 2.25mdeep below normal ground level) with top edge of the plate not less than 1.5mbelow normal ground level, connected to galvanized iron wire 4.0 mm diaby means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore includingGI lightgrade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing oncompletion all as specified and directed. 149 Taking up the unserviceable XLPE LT UG cable 3.5/ 4 core 16 Sqmm to 95 Sqmm from trenches or walls complete all as specified and as directed. 150 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed. 151 M&L for sand cushioning for protection of PVC cable with approved sand of uniform thickness, laid dry, by filling in trenches and punning to proper required cover complete all as specified and directed. Note:- Punned thickness shall be measured and paid. 152 M & L Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed. 153 Supply and fix in replacement of off load changeover switch AC, 4 pole, 415 volt upto 250 AMP complete all as specified and directed.