Tender For Addn/Altn To Certain Smqs At Af Stn Nal; 1 Demolition of cement concrete(unreinforced) of in ground floors and pavings n exc 15 cm thickness otherwise specifically provided including floor finishes complete all as specified and directed. 2 Providing and injecting emulsion for post construction anti termite treatment using chemical chloropyriphos 20EC conforming to IS 8944 or lmidacloprid 30.50 SC conforming to IS 16131 concentrate along the external wall of buildingbelow concrete or masonry apron using chemical emulsion @ 2.25 litre per linear metre including drilling 12mm dia holes @ 300 mm apart and plugging holes with cement mortar 1:2 (1 Cement 2 Coarse sand) in apron complete all as specified 3 Providing and injecting chemical emulsion for post construction anti termite treatment using chemical chloropyriphos 20EC conforming to IS 8944 or lmidacloprid 30.50 SC conforming to IS 16131 of soil under existing floorsusing chemical emulsion @ 1 Ltre per hole 300mm apart including drilling 12mm dia holes @ 300 mm apart and plugging holes with cement mortar 1:2 (1 Cement & 2 Coarse sand) to match the existing floor and making good the disturbed sufaces to match with the existing surface complete all as specified 4 Demolition of brick or stone masonary built in cement mortar incl all quoins, arches, pillar etc. complete all as specified and directed. 5 M&L brick work with sub class B bricks old size straight or curved on plan exc 6 m mean radiusbuilt in cement mortar 1:6 complete all as specified and directed. 6 M&L brick work with sub class B bricks old size in half brick thick walls, built in cement moratr 1:4 straight or curved on plan to any radius complete all as specified and directed 7 Demolition of cement Concrete of any description and in any position including any type of roof treatment, sunken portion, PCC padding, lime concrete etc, complete all as spd and directed.Note: All demolished material / debries will be taken by the contractor out side the Airforce station Nal with out any extra cost to the govt. 8 M&L for Cement concrete in foundations, filling and mass concrete Type E2 1:5:10 (using 40mm graded crushed stone aggregate) in sunken treatment, complete all as specified and as directed. 9 M&L Cement concrete 1:2:4 type C 1,(using 20 mm graded crushed stone aggregate) as in roof paddding,mass concrete finishing as required gradient cement concrete surface even and smooth without using extra cement including water proofing compoundcomplete all as spd and directed. 10 M&L for rendering plaster 15 mm thick in CM (1:4) using integral water proofing compound even and smooth using extra cementas per manufacturer instruction as in sunken floor complete all as directed by Engr-in-Charge.Note : Water proofing compound will be measuredand paid separately. 11 M&L Applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces, complete all as specified and as directed. 12 S&F in repair 40mm bore 600mm long GI spout pipe to drain out the surplus water from the sunken portion including cutting hole and making good the disturbed surface in PCC 1:2:4 complete as specified and directed 13 M&L 10mm thick screed beddingincement mortar 1:4 mixed with water proofing compound as per manufacturers instructions on concrete surface of roof and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.Note:- WPC shall be measured and paid separately. 14 M&L for water proofing treatment with APP based modified 3 layered prefabricated water proofing polymeric membrane over roof consisting of cleaning of concrete or plastered surface of roof and applying evenly a bitumen primer conforming to IS 3488 @0.3 kg per sqm followed by APP modified polymetric water proofing membrane minimum weighing 3.00 kg/sqm reinforced with non woven polyester fabric (wt. not less than 150 gms/sqm)land on primed surface by forced application complete unrolled and bonded to substrate with longitudinal and end laps 100mm or as per manufacturers instruction, and including taking the APP membrane will be required where the parapet wall exceed 45cm for carrying over and taking into parapet walls, cut out neatly a horizontal groove 6.5 cm deep, 7.5 cm wide section with lower edge at not less than 15 cm above the graded roof surface and groove shall be finished smooth with cement mortar 1:4 with WPC @3% by weight of cement where the parapet wall height is 45cm or less, no grove will be required as the water proofing treatment will be carried over the top of parapet wall to its full thickness complete all as specified and directed. 15 M&L 20mm thick Pre-cast Cement concrete tiles 1:2:4 type B0,(using 10 mm to 12.5 mm graded crushed stone aggregate), machine pressed; set jointed and pointed in cement mortar(1:3), including providing screed bed 15mm thick in CM(1:6), complete all as specified and directed by Engineer-in-Charge. 16 Supply only integral water proofingcompound. 17 Dismantling of wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off premises complete all as specified . 18 M&L for PCC(1:3:6) type C1 (using 20mm graded crshed stone aggregate) as in plinth protection of avg 75mm thick and finishing cement concrete surface even and smooth without using extra cement, complete all as specified and as directed. 19 M&L for Forming Contraction (Dummy) joints in Plinth Protection at every 2.5m length 10mm wide, filled with sealing compound of Gd A all as specified and directed. 20 M&L for 25 mm thick Cement concrete 1:2:4 type B0 (using 12.50mm graded crushed stone aggregate) over sub base correcrion floors, surface fair finished and even and rough to receive floor finishes. 21 M&L for Non - skid joint free Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over and including15 mm thick screed bed in CM(1:6), complete all as directed by Engr-in-Charge. 22 M&L for ceramic tiles coloured tiles 7 to 8mm thick, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM(1:6), complete all as directed by Engr-in-Charge. 23 All as per above item no 22 but as in skirting over and including 10 mm thick backing coat with cement mortar 1:4 complete all as specified and as directed. 24 M&L for glazed ceramic coloured wall tiles 450x300x7mm thick on vertical surfaces such as dados set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coatin CM 1:4 complete all as directed by Engr-in-Charge. 25 Demolition of stone slabs of any description or any thickness laid bedded and pointed in any mortarin floors and walls approns etc. 26 M&L for Granite 18-20 mm (of any type) work (table rubbed and polished)in steps, jambs, pillars, window-cills, cooking plat forms and like in cementmortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to matchwith shade of granite complete over and including20 mm thick screed bed in CM 1:6 complete all as specified . 27 M&L for Granite 18-20 mm (of any type) work (table rubbed and polished) jointed with gray cement slurry and pointed with white cement as in vertical surfaces / dado / skirtingwith admixiture of pigment to match the shade of granite stone indluding grindingand polishing complete over and including10 mm thick backing coat in CM 1:4 complete all as specified . 28 M&L for Rounding to edges of stone slabs one edge such as in steps & platform etc all as specified and directed. 29 M & L machine cut Kota Stone slab as in flooring / landing/treads (single piece)of stairs , 18-20 mm thick overand including 15mm thick cement screed bed in CM 1:4 , laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab and including rubbing and polishing and making grooves in treads ( as required ) complete all as specified. 30 M & L machine cut Kota Stone slab as in skirting/ Risers of stairs , 18-20 mm thick overand including 10 mm thick rendering in CM 1:4 , laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab and including rubbing and polishing complete all as specified. 31 Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified. 32 M&L reinforced cement concrete 1:1 1/2:3 type B1 (using 20mm graded crushed stone aggregate) as inslabs, suported on walls, beams and columns in floors, roofs, landings balconies canopies, deck slabs and in shelves and the like, complete all as specified and as directed. 33 Formwork to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exc 200 mm thick horizontal or sloping , rough finished flat surfaces complete all as specified and directed 34 Form work for concrete flats teads exc 5 cm but n exc 10cm wide rough finished, complete all as specified and as directed. 35 S&F mild steel TMT bars 10mm dia and over, cut to length & bent to shape required including cranking, bending spirally for hoping for column, hooking ends & binding with and including mild steel wire not less than on 0.9mm dia or securing with clips, complete all as specified and as directed. 36 S&F MSFramed work such as grills, gratings,handrails, staircase, cooler standetc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk water tanks and similar work including all necessary drilling or cutting holes in brick/ concrete surfaces and making good, welding work, bolting or reveting etc and similar work conforming to Fe-290 Gde E-165 37 Taking down frames with shutters n exc 1.50 Sqm each with shutterwithout taking off shutters from the frame. 38 Taking down frames with shutters exc 1.50 Sqmand n.exe 4 sqm each with shutterwithout taking off shutters from the frame. 39 Taking down shutters exc 1 sq. M and n exc 2 sq. M each of any description complete all as specified 40 Taking down shutters exc 1 sq. M and n exc 2 sq. M each of any description including resecuring , easing ,adjusting and refixing in same opening complete all as specified 41 S & F pressed steel frames of size 125x60mmfor doors with one or more rebates including necessaryfixing,lungs,hinges,lock strike plate, etc with one shop coat of primer complete all as specified and directed. 42 S & F pressed steel frames of size 105x60mmfor doors with one or more rebates including necessaryfixing,lungs,hinges,lock strike plate, etc with one shop coat of primer complete all as specified and directed. 43 Solid PVC door frame of size 50 mmx47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, suppling and fixing in opening as per specification and drawing. 44 S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bbottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing all as specified and directed 45 S&F factory made, 35mm thick plain, framed, panelled shutters (any No. of panels), with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers of 2nd class hard wood fitted to chowkats complete all as specified and directed. 46 M&L factory made, 35mm thick 2nd class hard wood glazed & gauged skeleton shutters open rebated and prepared to received glass/gauge etc ( without sash bars) edges of framing plains chamfered or rounded fitted with cut and mitered bead for securing glass , size of shutter as specified in SSR Part-I section 8 clause 8.24(a), complete all as specified and as directed.Note : - Wire mesh and glazing shall be measured and paid separatly in respected items . 47 M & L for Cement concrete PCC Type C0 1:3:6 using (12.5 mm graded crushed stone aggregate) as in filling in hollow pressed steel frames complete all as specified & directed 48 S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples as directed. 49 S&F 100 mm long butt hingestype B-22 extruded aluminium alloy with galvanised mild steel hinge pine complete all as specified. 50 S&F inAlumminium handles 150 mm,cast type ,anodised complete all as specified 51 Supply and fixing 60x 40 mm door stopperhanging type, consisting two leg aluminium anodised natural shade matt finishaluminium rod with rubber shoe complete all as specified 52 S&F mild steel 300mm, ordinary rat tail rod pattern springs, including roller and roller plate including welding or screwing to MS frame complete all as specified and directed. 53 S&F 150 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified. 54 S&F 200 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified. 55 S&F 300 MM long aluminium anodised sliding door bolt with hasp and staple(bolt type) and fixing clips of sheets cast of excruded section and fixing bolt and slidingbolts of extruded ections or cast-aluminium alloy and fixed. 56 S & F in repir pressed steel factory made cupboard shutter with frame of 1.25 mm thick and shutter 1 mm thick PBI sheet with 6 nos 3. 15 mm thick and 100 mm long steel (hinges godrej patern) locking arrangement incl 12 mm dia vertical rod incl spray painting in factory as approved pattern including taking down all as directed. 57 S&F GI pipe medium grade 15 mm dia with all fitting laid in floor or fixed in walls including taking down old GI tubes, complete all as specified and as directed. 58 Taking down/out and refixing onlyGI pipe medium grade 15 mm dia with all new fitting after necessary cleaning and laid in floor or fixed in wallsall as specified and directed.. 59 Taking down/out and refixing onlyGI pipe medium grade 20 mm dia with all new fitting after necessary cleaning and laid in floor or fixed in wallsall as specified and directed.. 60 S&F GI pipe medium grade 20 mm dia with all fitting laid in floor or fixed in walls including taking down old GI tubes, complete all as specified and as directed. 61 Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified 62 S&F as in repairlooking mirror of size 600x 450mm bevelled edge mirror of selected quality glass , mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers . all as specified 63 S&F in repair Vitreous china orrisa pan squatting pattern 580 X 440mm with integeral foot rests including P or S trap PVC low level flushing cistern 10 ltrs capacity and Flush pipe of polyethylene of low or high density or PVC. 32 mm dia complete as directed by Engr-in-Charge.Note : The cost of traps , flushing cistern and PVC flush pipes are included in this item. 64 S&F in repair vitreous china wash hand basin star white size550mm x 400 mm including CI brackets, CP waste coupling,waste pipe 32 mm borecomplete as directed by Engr-in-Charge. 65 S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm all as specified and directedNote : (i) The cost of waste coupling , PVC waste pipes are inclusive with this item and nothing extra will be admissible in to this account . 66 S&F as in repair fancy typepillar taps of 15 mm dia, cast copper alloy, with capstan heads, with chromium plated, screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed. 67 S&F in repair 15 mmstop valves/Angle valse ,but fancy type,chromium plated , cast copper alloy,screwed down,high pressure, with flange cap , screwed both ends for iron pipe or for unions and fixed. 68 S&Fin repair15 mm dia Bib taps, long shank, cast copper alloy with quarter turn, screwed down, crewed with flange cap for iron pipe or for brass ferrule and fixed. 69 S&Fin repair15 mm dia Bib taps,short body, cast copper alloy with quarter turn , screwed down, crewed with flange cap for iron pipe or for brass ferrule and fixed, complete all as specified and as directed. 70 S & Fixing-in-repair Chromium plated shower rose 125 mm diawith shower arms with or without swivel joints including fixing to steel pipe or union. 71 S&F 15 mm dia 45 cm long PVC water connection with brass nuts ( Hot and cold )and washersall as directed by Engr-in-Charge. 72 S&Fas in repair CP ( brass body )Towel Rail 600mm longfixed with and including Chromium plates brass screws and wooden /plastic cleats (minimum weight 170gms ) complete all as specified . 73 M&L for Stainless steel plate rack of size 31 x 30 x 10 of load capacity not less than 30 kg including fixing with stainless stell screws including taking down of old plate rack of any description complete all as directed by Engr in Charge 74 S&F in repairStainless steel ( SS 202 grade ) Curtain rod25 mm dia 0.80 mm wall thickness, mild steel, chromium platedincluding supporitng brackets as per sample complete all specified and directed. 75 S&F in repairs Stainless steel (Grade 305) ornmental type brackets (Open ends) suitable for curtain rods of 25mm dia complete all specified and directed. 76 S&F in repairs Stainless steel (Grade 305) brackets (Dead ends) suitable for curtain rods of 25mm dia complete all specified and directed. 77 M&L for PVC (SWR) floor trap with CP grating , plainincluding jointing with solvent cement outlet dia 75 mm in repair. Note : Cost of grating are included in this item. 78 M&L for PVC (SWR) floor trap plain with CP grating including jointing with solvent cement outlet dia 100 mm in repair. Note : Cost of grating are included in this item. 79 S&F in repairPVC low level valveless,syphonic action type, flushing cistern 10 ltrs capacity with inlet,ball valve,floatand handle incl bracketscomplete all as specified. 80 S & F in repair long body stop valve15mm borefancy type chromium plated with long shank and cup(concealed type)screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions. 81 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, incl PVC straps/clamps fixed to walls bore of the pipe 110 mm. 82 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches of bore of the pipe 110 mm. 83 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, incl PVC straps/clamps fixed to walls bore of the pipe 75 mm. 84 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches of bore of the pipe 75 mm. 85 S&F PVC(SWR) bends 110 mm dia. 86 S&F PVC(SWR) bends 75 mm dia.with access door. 87 S&F PVC(SWR) bends 75 mm dia complete all as specified . 88 S&F PVC(SWR) bends 110 mm dia. With access door 89 S&F PVC(SWR) reducer 110mm to 75 mm dia complete all as specified . 90 S&F PVC (SWR) junction single, (Single T) equal or unequal with access door110 mm bore complete all as specified 91 M & L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement including taking down old gully traps of any descriptioncomplete all as specified . 92 S & F PVC (SWR) vent cowl of 75 mm bore complete 93 Taking down cement plaster on brick or stone surfacsincluding raking out joints hacking for key scrubbing down with water etc. 94 Material and labour for repairing of RCC roof ceilng, projection, chajjas, facia, bands, shelves, beams, RCC railing, balcony and similar works by dismantling of loose/ disintegrated portion of RCC and cleaning the nacked reinforced bar with wire brush and applying rust remover as per manufacturers instructions, than applying anti-corrisive coating to r/f bars, at upto 7.5 m height,with necessary support, formwork and welding of reinforcement if required with wire mesh of weight 3 kg/ sqm and dubbing/ filling 1stcoat of 20 to 25mm thick in CM(1:3) finished rough and finishing coat of 10mm thick in CM(1:3) finished even and smooth without using extra cement after applying cement slurry .3 Kg/Sqm and applying three coats of whitewash complete all as specified and directed. Note : (i) Unit rate of this items includes the cost of scaffolding, form work, necessary water proffing agent etc and nothing extra shall be paid on account of variation if heights (ii) The measurement of finished plaster of 2nd coat provided on surface in sqm shall bethe mode of measurement against this item. 95 S&F Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcent Weight per square metre N exc4 Kg complete all as specified and directed 96 M&L for 15 mm thick rendering in two layers i.e. 10 mm thick in cement morter 1:4 in first layer and 5 mm thick in cement morter 1:4 mixed with approved water proofing compound on top layer,on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement all as specified and directed. Note: Water proofing compound shall be measured & paid seprately.) 97 M&L for preparation of new plastered surface and apply two coats of Acrylic Smooth exterior paint of required shade applied over and including a coat of alkali resistant primer in camaflouge pattern, complete all as specified and directed. 98 M&L for rendering 15mm thick on fair faces of brick or concrete surfacesin CM(1:6) finished even and smooth without using extra cement, complete all as specified and as directed. 99 M&L forprepartion of new plastered/ concrete surfaces and applying two coats of oil bound distemperover and including a one coat of primer over and including two coats ofacrylic basedwall care putty complete all as specified and directed. 100 M&L for rendering 5 mm thick on ceiling in CM 1:3finished even and smooth without using extra cement, complete all as specified and as directed. 101 M&L for preparation of new plastered surfaces ofceiling and applying three coat of white wash complete all as specified and directed. 102 M & L for Complete removal of existing treatment on ceilingby scrapping washing rubbing down etc and applying two coats of white wash all as specified and directed. 103 M & L for Complete removal of existing treatment on walls by with mechanical / electrical driven grinders suitable for removal work and scrapping washing rubbing down etc and applying two coats of oil bound emulsion over and includingtwo coats of wall care puttyover and including a one coat of primer all as specified and directed by Engr-in-charge 104 Material and Labour for complete removal of exhisting treatment of walls and applying two coats of acrylic exterior emulsion paint of approved colour/shade as in camouflaging pattern over and including a coat of primer, complete all as specified and directed by Engr-in-Charge. 105 M & L for preparation of old painted steel surfaces of any description over 10cm width or girthand applying one coats of synthetic enamel paints, complete all as specified and as directed. 106 Prep of newsteel surfaces and applying two coats of synthetic enamel paint over a coat of primer (red oxide primer) of any description over 10cm width or girth all as specified. 107 M&L painting two coats of synthetic enamel paints over a coat of pink primer on new wooden surfaces of girth exc 10CM , includingpreparation of surfaces, complete all as specified and as directed. 108 M&L for prep of old wooden surface of girth exc 10CMand applying a coat of synthetic enamel paints, complete all as specified and as directed. 109 Dismantling water tanks capacity exc 250 ltrs but n exc 500ltr and removing to store, complete all as specified and as directed. 110 S&F Rotational moulded polyethylene water storage tanks of500 ltr capacity (cylindrical vertical with closed top)with three layers white colour including hoisted and fixed in position all as specified in SSR Part I 111 S&F 20mm PTMT nipple suitable for HDPE water tank (minimum weight 15 mm-38gms/20mm-45gms/25mm-65gms) complete all as specified . 112 S&Fball valve high pressure of PTMT with epoxy coatedaluminium rod & high density plastic ball screwed for iron pipe20 mm diaof,, complete all as specified and as directed. 113 Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc for 500 ltr capacity water tankscomplete all as spd and drctd. 114 S&F factory made box type steel window 1.25mm thickERW hollow P section of each frame size 60mmx25mm including grill using 10 sqmm bar double rebated both guage andglass shutter comprised gaused glazed &Skelton shutterERW section 50mmx20mm & 1mm thick with two openable leaf consisting of two number sash bars of T-Section 20mmx3mm complete welded to frame with one vertical mullion of ERW box type T-Section of size 60mmx25mm and 1.25mm thickwith following fittings welded to the frame shutter :-i)Hold fast 150mm long mild steel flat iron 12x3 mm made to shape- 04 Nos per window. ii)Handle of Z section 20mmx25mm, 100mm long – 01 No per leaf.iii) MS tower bolt 150mm long 2 No per leaf. iv) Z section 20mmx25mm, 100mm long stopper – 01 Nos per leaf. v) Cleat 55 mm long of solid square 15x20x.63mm square - 01 Nos per leaf 115 vi) MS pintal hinges 12 x 75 mm- 2 Nos each leaf vii) 10 mm squre guard bar @ 10 cm c/c viii) 25 x 3 mm flat iron for joint of both frame wiremesh & Glazed welded inner side and outer side of frame (ix) 0.36 mm nominal dia of stainless steel wire mesh and average width of aperture 1.40 mm fixed in glazed/gazed skelton shutterof window(x)3mm thick sheet glass ordinary quality and with oil putty in squre n exc 0.50 sqm in each pane fixed in glazed /guage skelton shutter of window (xi) Two coat of synthetic enamel paint over a coat of primer.xii) Fabrication and fixing arrangements as per specificationincluding taking down, cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 /cement plaster 1:4 as require and make finish good to the existing surface complete all as specified and directed.Note: (i) Windows shall be povided as per the TD i.e typical details of Box window (Steel)with fly proof shutter.(ii)The mode of measurement shall be only one for the set of two i.e wire mesh window and glass window at one location and nothing extra shall be measured on this account. 116 S & F mild steel box type ventilator fixed type with glazing bar with mesh & glass all as per item ser No 114above 117 Supply and laying designchequred cement concrete tiles (Glossy finish) 30mmx30mmx22mm thick made by table vibratory method set, jointed and pointed in neat cment slurry as in floors with grey cement & pigment over 20 mm thick screed bed in CM 1:6 including 75mm thick cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in subbase/ sub floor complete all as specified and directed. 118 Dismantling boarding, any description any size , fixed in any position with screws complete all as specified . 119 S&F 18 mm thick Celuka Ply of density 600kg/cum of plain colour Sheet for kitchen cabinets sides, top, bottoms and shelves inside the cabinet, complete all as specified and as directed. 120 S&F 18 mm thick Celuka Ply of density 600kg/cum one side prelam/Rigidlam (Colour/Shade as approved by GE) and other side plain white colour to make kitchen cabinet shutters / drawer, complete all as specified and as directed. 121 S&F Auto closes clip on cabinet hinges (regular) for kitchen cabinet shutters, complete all as specified and as directed. Note : Each pair means one piece fixed on openable shutter and other piece fixed on fixed portion. 122 Supply and fixing Stainless Steel (SS 304) handles 100 mm size for Kitchen Cabinet Shutters, complete all as specified and as directed. 123 Takingdown carefully copper /aluminium point wiring light/fan, socket or power point /AC point complete including fittings such as switches, sockets, ceiling rose, bell push, bell buzzer, lamp holder bracket, fan regulator, tube light fitting removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditioning seperately ) and making good disturbed surfaces of walls,floor ,etc complete all as specified and as directed. 124 M & L for point wiring using 1.1 kV grade single core FRLSH flexible cable, conforming to IS 694: 2010, having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral, and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade UPVCrecessed conduits, conforming to IS 9537 (Part- 3): 1983, of size not less than 20 mm NB, including cutting chases making good the surface to match the existing surfaces,conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, and making good of disturbed surfaces of wall / ceiling / floor, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Notes- [i] Wiring from the DB (distribution box) to terminal boxes for power plugs, fan regulators, switches, socket outlets, etc. shall be deemed inclusive in the quoted rates.(ii) In case of ceiling portion where concealed conduiting is not possible, the surface conduit shall be provided ad directed. 125 One fan/light/bell point controlled by one switch, with cables 1.5 mm² size 126 One 3 pin socket outlet, 5/6 amps, independent board, with cables 1.5 sq.mm size 127 One 3 pin socket outlet, 5/6 amps, same board, with cables 1.5 sq.mm size 128 One 3 pin socket outlet, 15/16 amps, independent board, with cables 2.5 sq.mm size 129 S & F Socket 6A/16A - 2/3 pin combined2 module combinedswitch socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 130 S & F modular type 2/3 pin shuttered type 5/6 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 131 S & F modular type 15/16 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 132 S & F modular type 5/6 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 133 S & F Modular Bell push 6A 1 module conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 134 M & L for ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all as specified and as directed. 135 S & F Modular cover plate with frame of following module complete all as specied and directed. Note- Moduler switches, sockets and cover plate with frame shall be of same make and model. 136 8 Module 137 6 Module 138 3 Module 139 2 Module 140 S & F rectangular modular metal flush mounted sunken block of following modules suitable for mounting modular switches & sockets complete all as specified and directed 141 8 Module 142 6 Module 143 3 Module 144 2 Module 145 Supply and fixing stepped type electronic fan regulator , SP 230 Volt100/120 watt complete all as specified and directed. 146 Supply and fixingLamp holder angular PVC polycrbonate type with back plate suitable for PVC casing capping/conduit fitting complete. 147 Supply and fixingBell,AC 230 volts, single pole complete all as specified and directed by Engr-In-Charge. 148 S&F energy saving decorating box type batten light fitting 230 volts surface mounted complete with high effeciency glare free light LED lamp 20 watt(4 Feet)blue coloured end caps with all accessories, pre- wired,aluminium housing,polycorbonate difuser integrated heavy duty electronic driver havinng THD < 10% including providing flexible copper wire twin core cable complete all as specified and directed by enginer in charge. 149 Suply and fixing integratedLED bulk head luminaire 1 x 10 watt comprising of pressure die cast housing, acrylic diffuser & frameIP65 protection & available in 5700k (CDL) & 3000K (WW) colour temperatures pre-wired incl connection with flexible twin core wire complete all as specified and directed. CAT REF- LBHN-10-CDL, MAKE-crompton greaves or equivalent with list of makes. 150 S&F energy saving decorating box type batten light fitting 230 volts surface mounted complete with high effeciency glare free light LED lamp 10 watt(2 feet) blue coloured end caps with all accessories, pre- wired,aluminium housing,polycorbonate difuser integrated heavy duty electronic driver havinng THD < 10% including providing flexible copper wire twin core cable complete all as specified and directed by enginer in charge. 151 Supply and fix LED bulb 9 watt with lumen 850 complete all as specified and directed.Make :- Havell Cat Part No LHLDEUEEMC8R009or equivalent with list of makes. 152 Suply and fixing decorative type Wall light LED1 x 10 watt comprising of pressure die cast housing, acrylic diffuser & frameIP65 protection & available in 5700k (CDL) & 3000K (WW) colour temperatures pre-wired incl connection with flexible twin core wire complete all as specified and directed. 153 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC), complete all as specified and directed. 154 Supply and fix electric water heater ,storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre ,BEE 5 Star rated complete with all accessories such as safety valve,thermostate ,NRV,connection pipes etc complete all as specified and directed. 155 Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm with complete all as specified and directed. 156 Supply and fix exhaust fan, steel body AC single Phase. 230V, 50Hz of size 300m sweep with, blades, and frame and louverswith complete all as specified and directed. 157 S&F sheet metal enclosure single pole and neutral enclosure with two pin and earth plug and socket complete with one MCB SP 20 Amps complete all as specified and directed. 158 M&L for taking down carefully existing sub main wiring on wall (different sizes) and making concealed by refixing/ drawnthrough including chasing cutting in any type of masonary including suitable size of non-metallic PVC conduit fittings accessories and making good the disturbed surface match with the existing all as specified and directed. 159 Supply and laying sub main wiring complete with 03 runs ( phase, Neutral & Earthing colour code) of single core 10 sqmm fire retardant low smoke (FRLS)PVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through andincluding concealed non metallic PVC conduit minimum dia 20mm dia ISI marked andaccessories surface fixedon wall /flooretc all as specified. Note:- 03 runs of cable and 01 run of PVC conduit shall be considered as one unit for measurement purposes. 160 Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke and halogen (FRLSH)PVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through and including concealed non metallic PVC conduit minimum dia 20mm dia ISI marked andaccessories surface fixedon wall /flooretc all as specified. Note:- 03 runs of cable and one run of PVC conduit shall be considered as one unit for measurement purposes. 161 Taking down carefully Distribution board SPN of any sizes & any capacity by unscrewing including MCB SP/SPN from existing location all as directed. 162 supply and fixing MCB DB single pole and neutral 240 volt SPN 12 way with 200 Amps rated bus bardouble door type complete all as specified and directed.Make-IndoAsian/ Legrand/ ABBNote : Rate quoted shall deemed to be including for cutting existing wall for fixing DB in concealed making connections of sub main wiring (incoming and outgoing) with suitable size of cable lugs etc. and making good the existing surface. 163 Supply and fixing MCB SPN 32 Amps 240Volts, Breaking capacity 10 KA C curve complete all as specified and directed. 164 Supply and fixingMCB SP 40 Amps 240Volts, Breaking capacity 10 KA C curve complete all as specified and directed. 165 Supply and fixingMCB SP 5-32 Amps 240Volts, Breaking capacity 10 KA C curve complete all as specified and directed. 166 Supply and fixing vertical TPN DB double door, IP 45 protection with powder coated enclosure 4 way insulated busbar assembly including MCCB 4 pole, 415 V, 100/125A, 16 kA - 01 No complete all as specified and directed. 167 M&L for earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.50Mtr below ground level.The earth plate to be connetced with earth lead of 4 mm dia galvanised iron or steel wire all as shown in para no 4 the earthing test pointall as specified and directd.The GI earthing stripto be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with40mm dia HDPE pipe up to test point. Earthing shall be include withproviding funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth platefurther filled with60 cm thick Tibba sandand 2nd layer with30 cm of Magnesium sulphate powder (compact thickness ) , 3rd layerwithtibba sand up to the ground level. Earthing shall also be include for providingconcrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work including taking out old unsv earthing from existing location with complete all as specified and directed. 168 M & L for repair work of MS Electric Meter box of aprox. size (1200mm X 750mm x 300mm) by welding work, repalacing nut bolts etc and complete remoavl of paint and applying one coat primer with two coat enamelled paint including taking out existing electric meter and re-insatallation of meters with complete electric connectionswith all as specified and directed. 169 M&L for disconnecting from the existing location cutting off worn out aluminium cable end and Supply, laying and testing in replacement cable XLPEInsulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core including taking out existing cable of any size. 170 Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in softloose soil for laying / taking up/ taking down of cablesand getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge. 171 Returning filling in Including spreading, levelling. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. 172 Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge. 173 Material and labour for tiba sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified. 174 S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge. 175 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding techniqueand necessary machine or manually without damage nearby electric cable, water pipe line etc including HDPE pipe of 40 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. 176 M&L for bus bar chamber cubical inclined top out door type made out of 3 mm thick MS sheet of sizeminimum size 600 x 450 x 450 mm, MS angle section 35 x 35mm x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly powder coated inside and outside of bus bar chamberwith one coat of red oxide primer and two coat of synthetic enamel grey paint including aluminum busbar fixed horizontally in chamber of capacity 400 Amps for phases and 400 amps neutral for incoming and out going. The panel shall be suitable for 415 volts, 50 Hz, 3 phase 4 wire system (suitable for 01 incomer and 06 outgoing ) and shall have MCCB 250 Amp 4 pole 36 KA as incommer,with complete all as specified and directed by Engineer-in-charge Note :- (i) Earth work, PCC work and MS works shall be included in the unit qouted rate . (ii) Cable gland of brass for different size of cable as per requirement for incoming and outgoing cable