| 1 | CIVIL WORK |
| 2 | Excavation for foundation in earth, soil of all types, sand, grave land soft murum, including removing the excavated material uptoadistance of 50m. beyondthe building area & stacking and spreading as directed, de watering, preparing the bed for the foundation and necessary backfilling ,ramming, watering including shoring and strutting etc. complete.(Liftupto 0 to 1.50m.) By Mechanical Means |
| 3 | Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means |
| 4 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. |
| 5 | Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/quartzite/gneiss metal in foundation including necessary form work, compacting and curing etc, complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (Natural sand/VSI sand finely washed etc) |
| 6 | Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc, complete. |
| 7 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap /granite/quartzite/gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork, cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc, complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 8 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap /granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawings or directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grad |
| 10 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually strikingjoints, racking out joints watering and scaffolding etc. complete. |
| 11 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, wateringand scaffolding etc. Complete |
| 12 | Filling in plinth and floors with contractors aterial/brought from outsideand approved by Engineer incharge in layers of 15cm. to 20cm. including watering and compaction etc. complete. |
| 13 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc.complete. |
| 14 | Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws & bolts, lead & bitumen washers as per drawing etc. complete.(Weight of 5.5 kg/sq.m.). |
| 15 | Providing and fixing in position TMT FE 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. a) For TMT Fe 415 steel bars ( If Mild Steel/HYSD steel is to be used prior permission from S.E. shouldbe taken ) |
| 16 | Providing and fixing steel ventilator fully glazed partly fixed as perdetailed drawing with hot dip zinc coating including fabricating glazing with plain / obscured glass pans and approved type quality and iron oxidized fixtures and fastening with guard square bars 12 mm 10 cm c/c and oil painting 2 coats etc. complete. |
| 17 | Providing and fixing rolling shutter fabricated from steel laths ofminimum thickness 0.9 mm with lock plate of 3.15 mm thicknessreinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth andthickness not less than 65 mm and 3.15 mm espectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete |
| 18 | Providing internal cement plaster 20mm thick in two coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete |
| 19 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete |
| 20 | Providing and applying two coats of water proof cement paint ofapproved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. |
| 21 | Providing and Fixing 110 mm diameter PVC Rain Water pipe withnecessary fittings such as bends, tees, single junctions, slotted vent,clamps etc complete. |
| 22 | Shooting of still photograps outdoor and indoor of construction and other works of building , bridges, roads etc. in District and outside dist. At any distances ii) a set of same three copies of 4 \" x 6 \" Size |
| 23 | ELECTRIFICATION WORK |
| 24 | Supplying, erecting & terminating FR XLPE insulated ,galvanised steel wire armoured cable 1100 V, 4 core 10 sq.mm. copper conductor FROM TRANSFORMER TO MAINScontinuous 5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/pipe as per specification no. CB-LT/CU |
| 25 | Supplying, erecting & terminating FR XLPE insulated ,galvanised steel wire armoured cable 1100 V, armoured cable 4core 6 sq. mm. copper conductor FROM MAINS TO DBcontinuous 5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/pipe as per specification no. CB-LT/CU |
| 26 | tar road for laying provided LT cable up to and including 16 sq.mm complete as per specification no. CW- EXNCTR andattached drawing including RCC pipe of 6\" dia with collar at roadcrossing. |
| 27 | Making trench of suitable width and depth 1 mtr in soft soil layingprovided LT cable up to and including 16 sq.mm complete asper specification no. CW-EXN-CTR and attached drawing. |
| 28 | Supplying and erecting PVC unarmoured cable 1100Volt gradeISI mark 3 core / 2.5 sqmm stranded solid copper completeerected on wall/ trusses with duly painted G. I. Saddle FORINDOOR FLOOD LIGHTS and OUTDOOR STREET LIGHTSfrom MCB DB to lighting fittings and making proper connectionwith glands and lugs as required. |
| 29 | Point wiring for 6A / 16A plug point with PVC Insulated PVCRound Sheathed stranded 3X4 sq.mm. (56 no./0.3mdia) copperconductor FRLS wire of Voltage grade upto 1.1 kv in PVCconduit of FRLS grade of appropriate size and clipped withsaddle , clamps with GI screws on wall with colour coding WIRER-B-G as required as per specification no. WG-MA/CON andWG-MA/BW |
| 30 | Supplying and errecting shockproof 6pin 6A and 16 A withswitches 16 A combine Unit errected on metal box / modular boxsurface mounted industrial type as required. |
| 31 | Supplying And errecting integrated LED flood Light fitting max.30W IP65 & IK07 class having pressure die cast alluminiumhousing, having system lumens output of Min. 3000 Lumens ,min. efficacy of 100 lumen/W , CRI >70, CCT upto 6500K ,THD<10%, PF >0.90 , operating range of 140-270V , inbuilt surgeprotection of 4KV, LIFE CLASS OF 50000 Hrs. atL70B50,including driverwith U shaped bracket with 3 years warrantyasper specification no. FG-ODF/FLS2 complete errected ontrusses with fixed with suitable GI clamps complete as required. |
| 32 | Supplying And errecting integrated LED street Light fitting max.26 to 30W IP65 & IK08 class having single piece pressure diecast alluminium housing, having system lumens output of Min.2600 Lumens , min. efficacy of 100 lumen/W , CRI >70, CCTupto 6500K ,THD <10%, PF >0.95 , operating range of 140-270V , inbuilt surge protection of 10 KV, LIFE CLASS OF 50000Hrs. atL70B50, including driverwith U shaped bracket with 3years warrantyas per specification no. FG-ODF/FLS2 completeerrected on wall with GI pipe of appropriate dia. fixed with GIclamps complete as required. |
| 33 | Supplying and errecting tripple pole and neutral distributionboard (TPNDB) , SPMCB of 8 ways/phase (24 poles), with door,1.2 mm thickness surface/ flush mounted, IP43 protection oniron/ GI frame (horizontal bus bar type) as per specification no.SW-SWR/MCBDB as required |
| 34 | Supplying, errecting and commissioning of 4 POLE RCCB 40 Aelectromagnetic type with 30/100/300 mA sensitivity with earthleakage trip indication complete as per specification no. SWRCCB/ RCCB in provided distributioon board as per specification no. |
| 35 | Supplying, errecting and commissioning of following SP MCCB6A to 32 A , C-series with rated short circuit breaking capacity(Icn) 10 KA in provided distribution board with accessories likebus connectors, screws etc as per specification no. SWSWR/MCB; 1) SPMCB 6/10A :18 NOS, 2) SPMCB 16 A:6 NOS |
| 36 | Supplying, errecting and commissioning of following 4 pole RCCB 63A 1 NO) AND 4 POLE RCCB 40 A (02 NOS) electromagnetictype with 30/100/300 mA sensitivity with earth leakage tripindication complete as per specification no. SW-RCCB/RCCBwith distributioon board 1.2mm thickness surface / flushmounted, IP43 protection on iron/ GI frame as per requirement. |
| 37 | Providing , earthing with galvanisediron earth plate size 60 x 60x 0.6 cm complete with all materials, testing & recording theresults as per specification no. EA/EP and as per attacheddrawing |
| 38 | Providing pipe type earthing with 40 mm dia. GI pipe or 20 mmdia. GI rod complete with all materials, testing & recording theresults as per specification no. EA/EP and as per attacheddrawing. |
| 39 | ROYALTY CHARGES |
| 40 | Sand |
| 41 | Other Minarels |
| 42 | LAB TESTING |
| 43 | Sand- Fineness Modulus,silt and clay content |
| 44 | Aggregate/Crush material a) Carrying out water absorption b)specific gravity c) Impact Valued) Crushing Value |
| 45 | Cement- Cement- Standerd Consistency,fineness, , Setting Time (Initial And Final), compressive strenght, soundness |
| 46 | Concrete M10 Grade- Concrete cube Compressive Strength (set of 3 cubes) |
| 47 | Concrete M20 Grade- Mix design M20 with all tests on besic materials |
| 48 | Concrete M20 Grade- Concrete cube Compressive Strength (set of 3 cubes) |
| 49 | TMT steel bars- Steel - Tensile strength,Yield stress, ultimate tensile stress,%elongation, weight per running meter,Bend/Rebend test.(Set of 3 Bars) upto 16 mm (set of 3 bar) |
| 50 | Murum plasticity Index, fild density of copacted layer, proctor test |
| 51 | Bricks: Crushing Value, Absorption Value, Specific gravity |
| 52 | ESHS PLAN |
| 53 | ESHS (Environment Safty and Health ManagementLabour Facilities (Lump- Sum Amount ) |