| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-10-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-10-2025 |
| 2 | 01-10-2025 | CORRIGENDUM | Other | 17-10-2025 |
| Sl. No. | Item Description |
| 1 | Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixture and fittings suchasswitches,ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 2 | M&L point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metalic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly complete all as specified and as directed by Engr-in-charge.(a) One light/Fan point controlled by one way switch 6 Amps 240 volts |
| 3 | (b)Ditto all as per item no.02 above butOne 3 pin 6 Amps socket out let point on independent board. |
| 4 | (c)Ditto all as per item no. 02 above butOne 3 pin 6 Amps socket out let point on same board. |
| 5 | (d)Ditto all as per item no. 02 above butOne bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size. |
| 6 | M&LPoint wiring with 2.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable and including surface, Non metalic rigid PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 2.5 sq mm copper conductor as earth wire to common earth dolly for outlet power point independent circuit complete all as specified and as directed |
| 7 | S&F in repairfor white cover plate with frame 1 or 2 module complete all as specified and directed.. |
| 8 | S&F in repairfor white cover plate with frame 3 module complete all as specified and directed.. |
| 9 | S&F in repairfor white cover plate with frame 4 module complete all as specified and directed.. |
| 10 | S&F in repairfor white cover plate with frame 6 module complete all as specified and directed.. |
| 11 | S&F in repairfor white cover plate with frame 8 module complete all as specified and directed.. |
| 12 | S&F in repairfor white cover plate with frame 12 module complete all as specified and directed.. |
| 13 | S& F in repair PVC unbreakable surface boxes suitable for modular switches 1 or 2 module complete all as specified and directed.. |
| 14 | S& F in repair PVC unbreakable surface boxes suitable for modular switches 3 module complete all as specified and directed. |
| 15 | S& F in repair PVC unbreakable surface boxes suitable for modular switches 4 module complete all as specified and directed. |
| 16 | S& F in repair PVC unbreakable surface boxes suitable for modular switches 6 module complete all as specified and directed.. |
| 17 | S& F in repair PVC unbreakable surface boxes suitable for modular switches 8 module complete all as specified and directed.. |
| 18 | S& F in repair PVC unbreakable surface boxes suitable for modular switches 12 module complete all as specified and directed.. |
| 19 | S & Fin repair modular switch 10 Amps , 1 module all as specified complete all as specified and directed.. |
| 20 | S&Fin repair Modular switch 1 way 16A, 1 Module with neon indicators complete all as specified and directed. |
| 21 | S&F in repairModular Socket 6/16A, 2/3 Pin combined, 2 Module complete all as specified and directed. |
| 22 | S&F in repair modular socket6A-2/3 pin combined, 2 module complete all as specified and directed. |
| 23 | S&F in repair of 1 module Blanking plates complete all as specifed and directed |
| 24 | S&F in repair modular Bell push, 6 Amp with neon indicator one module complete all as specified and directed. |
| 25 | S&F in repairmodular fan regulator 120W,240V, 2module, suitable for ceiling fan of 1200/1400mm sweep complete all as specified and directed. |
| 26 | M&L in repair of door bell AC 230 volts single phase ding dong type all as specified and directed. |
| 27 | S&Fin repair ceilingrose surface shall comply with IS :371-1979 Bakelite 60x 25 mm two to three terminals plates and of outside diameter not less than 63.5mm complete all as specified and directed. |
| 28 | S& F in replacement of Inverter RTC operational LED Security light fitting 45Watt Pipe mounted , Hsg made of Pressure die-cast aluminium alloy for effective thermal management(heat sink),excellent corrosion resistant. Tempered protective toughened glass or PC Cover IP66LED Security Light . System wattage consist of max 45 W with Composite / Individual Optical Lens cover to ensure better uniformity. High efficiency long life SMD LED module with lumen efficacy of 140lm / W to enhance the lumen output. MCPCB and SMPS based constant current supply Integral driver with Output Short-Circuit Protection. Min Luminaries System Lumen4900 - 5000 lm with efficacy > 110lm/W with In built Emergency Inverter operational principle i.e.on Emergency Inverter Light Output-Initial Lumen at Battery mode operate at 15- 20 % of rated lm with in built RTC ON/OFF TimingAuto ON (Astro Sun Set -30 minutes)and Auto OFF (Astro Sun Rise) • Emergency Inverter Back up:1.5 - 2 hrs at battery fully charge STC operation ( 3.7 V / ooooWH Li-ion Battery ) . CRI > 70, IP 66 , Color temperature 5700 K, THD <10 % and PF >0.95, Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ;Internal Surge Protection: 5 KV . complete all as specified and directed. Make Halonix-HLSLD-ML04-45w-CWL-INV-RTC-R-Bor equivalent make as mentioned at list of makes in PS |
| 29 | S&F inrepair ofPVC insulated copper cable 4 Sqmm 3 core, served with inner sheathing of PVC tape and overall PVC sheathed including PVC Conduit ISI Marked 20mm including all necessary bends, couplings, tees, and other accessories.Surface Saddling of PVC Conduit on Wall using approved saddles and fixing screws. Spacing as per specifications ( 1-meter intervals).complete all as specified and directed. |
| 30 | S&F inrepair of 20 watt,230V surface and wall mounted Inverter LED batten, automaticaily switched ON during a power cut and runs effiectively up to 3 Hrs,extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose complete all as specified and directed. |
| 31 | Supply and fix in replacement of exhaust fan, steel body AC single Phase. 230V of size 300msweep with, blades, and frame andlouvers complete all as specified and as directed. |
| 32 | S&F in repalcement surface/recess mounted 4\" x 1\" LED Panel lights 45 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving,high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver. |
| 33 | M & L inreplacement of Sub Main wiring with PVC insulated FRLSH grade cable LT 1100 Volts grade, 2 x 4 Sqmm with one continuous earth wire of 4 Sqmm, PVC insulated unsheathed, multistranded with stranded copper conductor drawn through PVC casing capping ISI marked of suitable size on wall, roof, etc, with all connected fittings with all standard accessories and make good to match with the existing surfaces after completion alongwith one continuous earthwire and connected to the common earth complete all as specified and as directed.Note :-2 runs of 4 Sqmm and One run of 4 Sqmm earth wire and including suitable size of PVC pipe, elbow, bends etc shall be measured as One Running Meter |
| 34 | M&L in replacement recess mounted 2\" x 2\" LED Panel lights 40 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving,high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver. |
| 35 | S&F in replacement of plastic body ventilation fan of 200 mm sweep including connected accessories all as specified and as directed. |
| 36 | S&F in replacement ofsheet metal enclosures single pole MCB 20 Amps with a two pin and earth plug and socket complete with all accessaries etc all as specified and directed. |
| 37 | S&F in repairs MCB DB 08 way SPN Single door sheet metal enclosure factory made suitable for MCB DB\"s 240 voltswith 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and existing circuits complete as reqd at site complete all as specifed and directed |
| 38 | Supply and fix in replacement of C Curve MCB SPN 6-40 Amps working on 240 volts, 50 HZ,10 KAall as specified and directed. |
| 39 | S&F in repairMCB SP 6 to 40 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and directed. |
| 40 | M & L in repair for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanizedearth lead wire 4.0 mm diaby means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to Change over switch panel including necessary excavation and earth work, concrete pit & chamber,pit cover made of PCC 1:2:4 type B1 with lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh, etc. complete all as specified and directed . |
| 41 | Supply and fixing in repair post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect lightIP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.. |
| 42 | Supply and fix in repair 5 W LED Solar garden light of lithium ferrous 3.7 V 5200 mAH battery,automatic on/off using LED sensor IP 65 Protection aluminium bodyall as specified and directed .Make : Luker Catpart No. LBRSOL600 or equivalent make as mentioned at list of makes in PS |
| 43 | S&F inrepair of 200 watt integral SMD LED Highbay luminaire with aluminium reflector light fitting includind with inbuilt electronic drivers, necessary hanging arrangements as per site requirement including taking down the existing one all as specified and directed Note: 1. Ladders /Cranes shall be used and will be provided by contractor for dismantling /fixing of light fittings at roof and cost for the same is deemed to be included.Make Luker Cat part no. LOHY200or equivalent make as mentioned at list of makes in PS |
| 44 | S & F in replacement of LED indicator lamp Red/Yellow/Blue size and capacity as per existing including drilling and cutting the panel sheet if required complete all as specified and directed. |
| 45 | S & F in replacement of Cylindrical panel locks size as per existing including cutting and drilling the panel sheet if required complete all as specified and directed. |
| 46 | S & F in replacement of Cold rolled mild steel hinges suitable to existing APFC panel door or as per sample including cutting/welding to panel sheet and painting to match with the existing colour complete all as specified and directed. |
| 47 | M & L for demolition of un-reinforced PCC, floors etc in any position and any description including removal of demolished material atleast 100 mtr away from site complete all as specified and directed. |
| 48 | M & L for Plain Cement Concrete (1:3:6) type C2 (40 mm graded aggregate) for foundation, filling and mass concrete including necessary form work etc complete all as specified and directed. |
| 49 | Supply only chain link as in fencing MS galvanised of 3 mm dia MS wire, including line wires, of mesh size 50 mm x 50 mm, rails, straining bolts, etc. including provision of binding wire any size or type complete all as specified and directed. |
| 50 | Fixing only chain link fencing MS galvanised of 3 mm dia MS wire, including line wires, of mesh size 50 mm x 50 mm, rails, straining bolts, etc. including provision of binding wire any size or typeincluding taking down existing one complete all as specified and directed.Note: Supply of Chain link fencing shall be measured and paid separately under respective item. |
| 51 | Fixing in repair and Tightening/re-stretching chain link fencing of MS galvanised of 3 mm dia MS wire, including line wires, of mesh size 50 mm x 50 mm, rails, straining bolts etc with suitable size of GI binding wire complete all as specified and directed. |
| 52 | M&L in replacement for Fabrication of MS work as in Hand rails, Angle Iron, Channel,half round or other steel section and drilling and welding for countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing or Partking Shed etc including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 53 | M & L in replacement for MS round/square bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for chain link fencing, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to MS round bars complete all as specified and directed. |
| 54 | S & F in replacement of 0.63 mm thick Galvanised, Corrugated mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or Cranked hook bolts, nut and washers, in roofs, walls etc at standard spacing /gaps with grade of Zinc caoating 275 complete all as specified and directed. |
| 55 | S & F in repair junction box inner dimension approx 300mm X 200mm X 105mm (HxWxD), 3 phase, 4-wire system, including 6 Amp MCB DP with mounting channel, cable connecting base, Cable lugs of suitable to 16/10 Sqmm 4 core cable, cable connection for incoming and outgoing cable etc including fixing arrangements at tubular poles/walls with suitable size of strip, nut-bolts etc complete all as specified and directed . Make : National/Sintex or its equivalent as approved by GE. |
| 56 | Supply & Laying in replacement Synthetic Rubber Insulated Mats 2.5 mm thick for Voltage upto 11KV working pressure conforms to IS 15652-2006 and applying adhesive to fix before laying the new one complete all as specified and directed. |
| 57 | M & L in replacement for Synthetic insulation mat of size 2m x 1m x 19mm complete all as specified and directed. |
| 58 | M & L for removing deteriorated existing stone aggregate of any size and type from Sub Stn Yard by excavating upto the natural ground surface and depositing where directed and cleaning the complete sub stn yard, removing tree roots, sepplings, grass etc and spreading 1\"\" layer of lime and relay / re-spreading the same existing stone aggregates of any size and type from Deposited place, in to the same Sub Stn Yard completeall as specified and directed |
| 59 | M&L for 40 mm graded stone aggregate for evenly spreading at sub station yard upto the required thickness from natural ground level complete all as specified and directed. |
| 60 | M & L for 20 mm graded stone aggregate for evenly spreading at sub station yard upto the required thickness from natural ground level complete all as specified and directed. |
| 61 | M & L for servicing and repairing of Gang Operating Device by taking proper shutdown and applying petrolium jelly on male female contacts, tightning Nut, Bolts and washers and also Jumpers, lightning arrestors, etc including one coat of Aluminium paint on complete 2 pole structure i.e. Tubular pole, MS Channel etc complete all as specified and directed |
| 62 | M & L in replacement switch air break triple pole mechanically operated mounted on insulator and GI Channel steel frame complete with operating mechanism worked from ground level for current rating upto 200 Amps for 11000 volts including taking down existing one all as specified and directed. Make - Jaipuria Bros / Rashtriya/Elpro |
| 63 | M&L in replacement Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp suitable for 11000 volts including taking down existing one all as specified and directed.Make - jaipuria Bros / Rashtriya/ Elpro |
| 64 | M & L in repair for Straight Through jointing kit suitable for 3 core 95 Sqmm XLPE 11 KV HT armoured aluminium conductor cable (Earthed) grade for straight through termination heat shrink type joint complete with jointing material and accessories including taking shut down and opening the cable from both side of Bus Bar Panel/VCB/RMU/GOD etc and re-terminated the same cable in the same Bus Bar Panel/VCB/RMU/GOD etc after completion of jointing work complete all as specified and directed. |
| 65 | M&L for replacement of earthing complete with galvanised steel earth plate electrode 60x60cmx6.3mm GI thick burried directly in ground ( earth plate pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to eqpts/panel etc complete all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil strata and pit re-filled with Charcoal, Salt and black cotton soil.PCC chamber (1:3:6) type C1, PCC pit cover, funnel with wiremesh including 20mm dia medium grade GI Pipe for watering complete all as directed. |
| 66 | M&L in replacement of GI strip 25 x 4 mmas earth continuityconductor or main earthing lead fixed to wall batten or recess or chases or buried in ground or drawn in conduit/pipe or fixedto poles or any other indicated situation with suitable size of SMC/FRP Insulators at suitable gaps, nut, bolts and washers etc complete all as specified and directed. |
| 67 | Pruning / trimming of branches of trees interfering or overhanging electrical overhead lines in such a way to have a clearance of not be less than 2 mtrs from the outermost conductors on both side including thrown away the same atleast 100 mtr from the site complete all as specified and directed . Note : Span of conductor shall be measured from insulator to insulator without allowance for overlapping. |
| 68 | S & F in replacement of HT jumpering with the help of Aluminium Counductor Steel Reinforcement covered with insulating material/sleeve and suitable size of aluminium Lugs, nut, bolt and washers etc. The length of jumper shall not be less than 3 meter including connection with the help of connector on the HT pole complete all as specified and directed |
| 69 | S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of3.15 mm thick CRCAsheet with epoxy powder coating of RAL-7032 ( Siemens Gray) shade with matt finishwith seven tank pre treatment process.The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof.All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable.The panel shall be provided with aluminium bus bars of 300 Amps current rating.The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally.The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment and provision of incoming and outgoing cable.All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 25mmx25mmx4mm thick angle iron supports of not less than each 1 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at uitable depth as per site requirement.The overall size of the Busbar panel shall not be less than 400mmx200mmx550mm (LxDxH).including earthwork all as specified and directedNote : (i) 4 Nos of Entry holes for cables from bottom side shall be provided upto 50 Sqmm and each busbar shall be provided neccessary arrangement to connect 4 Nos of cables including Nut bolts etc |
| 70 | S&F in replacement of GI bracket suitable for LED street light fitting including suitable size of clamps, nuts, bolts etc and fitted on the street light pole including taking down existing one complete all as specified and directed |
| 71 | S & F in repalcement LED Street Light 100 W, 230 Volts, AC Outdoor type made up of pressure die cast housing with individual LEDs with modular secondary optics and IP 55 protection, including taking down existing one complete all as specified and directed. |
| 72 | S & F in repalcement of LED Post tops 40 W, 230 Volts AC, Outdoor type, made uppressure die cast aluminium housing with decorative clear opal acrylic diffuserand IP65 protection including taking down existing one complete all as specified and directed.Make : Bajaj Cat Part No BGCT W4 LED or equivalent make as mentioned at list of makes in PS |
| 73 | S & F in replacement PVC insulated copper cable 3 core 1.5 sqmm multi-stranded for security light/street light and to be drawn through properly hole of street light poleincluding making of 10mm dia 2 hole in street light pole i.e. 01 x top and 01 x bottom of the pole andtaking down existing one complete all as specified and directed. |
| 74 | Supply & laying in replacement including, fixing on walls, floors with suitable size of GI Clamps, nuts, bolts and washers etc of LT cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi-stranded aluminium conductor of sizes 4 core 10 Sqmm complete all as specifed and as directed.Note - Excavation / earthwork, Bricks Cable Cover & sand cushioning will be measured and paid separately under respective item of sch A. |
| 75 | Ditto all as per item No 74 above but 4 Core 16 Sqmm |
| 76 | Ditto all as per item No 74 above but 3.5 Core 25 Sqmm |
| 77 | M&Lin replacementsteel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts & screws as specified type 410 SP-31 (9 mtrs long) as Pole/Strut including dismantling old/US steel struts, complete all as specified and directed. |
| 78 | Excavation in trenches, n.exc 1.5m wide and n. exc 1.5 m depth and getting out in for foundation of pole, stay, laying of cable and pipe etc as in Hard/Dense soil complete all as specified and directed |
| 79 | Returning and filling in, including spreading and well ramming in layers n exc 25 cm all as specified and directed. |
| 80 | Removing excated material a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting pointall as specified and directed. |
| 81 | M&L for dry sand cushioing to under ground cable intrenches incl spreading, leveling and hand punningall as specified and directed.Note : For measurement purpose punned thickness shall be considered. |
| 82 | Supply and laying common burnt clay building sub class B old size bricks, laid in right angle along the cable,all as specified and directed. |
| 83 | Supply and lay in replacement of GI pipe light grade with all fittings required for protection of under ground cable of 100 mm diaall as specified and directed. |
| 84 | Ditto all as per item No 83 above but 80 mm dia |
| 85 | Ditto all as per item No 83 above but 50 mm dia |
| 86 | M&L for road cutting size according to site requirementfor laying pipe and crossing cable etc including make good with existing material or with PCC 1:2:4 type B1 complete all as specified and as directed. |
| 87 | M&L in repairs for straight through Jointing Kit, heat shirnkable type complete with all jointing materials and suitable for 1100 Volts XLPE LT UG Power Cable aluminium stranded conductor of following sizes cable including taking shut down and opening the cable from both side of Bus Bar/Feeder Panel/LT Panel/ACB etc and re-terminated the same cable in the same Bus Bar/Feeder Panel/LT Panel/ACB etc after completion of jointing work according to existing system complete for 3.5 Core 25 Sqmm size all as specified and directed. |
| 88 | Ditto all as per item No 87 above but4 Core 16 Sqmm |
| 89 | Ditto all as per item No 87 above but4 Core 10 Sqmm |
| 90 | S & F in replacement MCCB 4P 250 Amps, 36 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu including suitable size of spreader links with galvanised or codmium plated high tensile nuts, bolts and washers etc including cutting of panel Sheet and drilling also without disturbing to the existing accessories complete all as specified and directed. |
| 91 | Ditto all as per item No. 90 But 4P 40 Amps, 16 KA. |
| 92 | Ditto all as per item No. 90 But 4P 63 Amps, 16 KA. |
| 93 | Ditto all as per item No. 90 But 4P 100 Amps, 16 KA. |
| 94 | Ditto all as per item No. 90 But 4P 125 Amps, 16 KA. |
| 95 | Ditto all as per item No. 90 But 4P 200 Amps, 36 KA. |
| 96 | M & L for core cutting, boring/ drilling in any type of walls (i.e Stone walls etc) of suitable dia for passing the LT Cables of size from 10 Sqmm to 400 Sqmm, Earth conductors etc including filling/making good to the disturbed surface of walls with existing one complete all as specified and directed. |
| 97 | M & L for repair of Battery Charger, Input : 220/250 Volts, AC, 1-ph, Output : 6 to 72 Volts, DC, 10 Amps complete with taking down burned core and coil winding and made it serviceable by change and re-winding the coil with new copper wire as per existing gauge including core assembly etc complete all as specified and directed.Note :- The rates quoted against the item is deemed to be included for cost of Labour, cost of T & P required for servicing and cost of handling / transportation of defective item to and from Civil workshop for repair / servicing.Make of charger : Nana |
| 98 | Supply and Installation in replacement of lead acid DC battery 12 Volts, 180 AH complete with electrolyte and initial charge with required size of lugs and terminal cap etc including taking down existing one complete all as specified and directed.Make : Exide/Amron |
| 99 | Supply and Installation in replacement of Inverter potable type of 950VA/760W capacity, Busbar rating 12V DC 58+/- 2A, Input : 220V/5.32A AC, 50 Hz, 1-ph. Output : 220 V/4.32A AC, 50 Hz, including complete electrical connection according to existing system and taking down existing one complete all as specified and directed .Make : Microtek/M-Guard/Liminous /Su-kam |
| 100 | Supply and toping up of distilled water in batteries as per site reqirement at various sub/stns inside NDA campus complete all as specified and directed by Engr-in-Charge.Note : Distilled water supply in sealed container or bottlescomplete all as specified and directed. |
| 101 | M & L for preparation of surfaces by peeled off or scrapped down rust/old paints from Sub Stn fencing, mesh size (50 x 50) mm including both side of Angle iron supports, MS bar, MS Strip etc complete and apply one coat of synthetic enamel Sky Blue /smoke grey paint on the complete sub station fencing by brush complete all as specified and directed. |
| 102 | M & L for preparation of surfaces by peeled off or scrapped down rust/old paints from MS Gate, Rolling Shutter etc of any description over 10 cm width or girth free from dust, dirty, loose scale grease etc scrapping with sand /abrasive paper or pumic stone touching up and apply of one coat of synthetic enamel Sky Blue /smoke grey paints on the same MS Gate, Rolling Shutter etc by brush or spray complete all as specified and directed. |
| 103 | S & F in repairsAir Termination, single pointed, Aluminium rod 8 mm dia and 300 mm long with base plate including suitable for fixing on AL strip on ideal position on top of the roof etc complete allas specified and directed.Note : Suitable arrangement i.e ladder, scafolding or any other working plateform required for climbing on high rise buildings and structure for carryout said work is the responsibility of vendor/contractor and the rates are deemed to be included in this quoted rate. |
| 104 | M & L in repairs for Aluminium strip of size (25 x 3.15) mm including fixing with suitable size of SMC/FRP insulators/ GI Saddles, nut, bolts, washers and screws etc for roof conductors and down conductors above ground complete all as directed.Note : Suitable arrangement i.e ladder, scafolding or any other working plateform required for climbing on high rise buildings and structure for carryout said work is the responsibility of vendor/contractor and the rates are deemed to be included in this quoted rate. |
| 105 | Fixing in repair with suitable size of Fastners, nut, bolts and washers in any type of wall and servicing of MS Rolling shutter, size approx (3.0 x 4.0) Mtr approx by applying the grease /petrolium jelly/ Lubricants etc and make it stress free / smooth operation/movement complete all as specified and directed . |
| 106 | M & L for fixing in repair of Angle Iron Gate by providing and welding the holdfast/hinges of suitable size/ capacity with existing Pillars or column on both side and make this MS gate openable without any hindrance complete all as specified and directed. |
| 107 | Labour for cleaning the complete Sub Stn Yard of size (20 x 15) Mtr approx including fencing and 1 mtr all around the Sub Stn fencing by removing/cutting/digging out from roots oftrees, bushes & sepplings etc and thrown away the waste atleast 100 mtr away from the sub stn yard complete all as directed |
| 108 | Labour for cleaning the drain, size (0.5 x 1.0) Mtr (W x D) including dug out and removing the Rubbish/mud/ foreign materials and thrown away the same atleast 100 mtr from the MRS Compound complete all as directed |
| 109 | Labour for tree branch cutting of high rise trees, overhanging/interferencesto the Two/Four Pole Structure GODs(size of tree branch approx 80 mm to 300 mm dia) without damages to the Two/Four Pole Structure/GODs etc including thrown away the same alteast 100 Mtr away from the Sub Stn Yard complete all as directed. Note : Suitable arrangement i.e ladder, scafolding or any other working plateform required for climbing on high rise trees for carryout said work is the responsibility of vendor/contractor and the rates are deemed to be included in this quoted rate. |
| 110 | Supply only hand gloves HT for operating / handling sub station 22 KV ISI marked complete all as specified and as directed. |
| 111 | S & Fin replacement of illuminated display board of size (1.28 x 0.2 x 0.9) Mtr (L x B xH)with Flexof Light Blue (MES Colour),Colour of letters shall be white, outerside fabrication bordered with Aluminium angle Frame of size (20 x 20) mm x 3mm thick, innerside fabricated with 12mm MS square bar and aluminium sheet for top, bottom, back side, left side and right side of the display board, 50mm dia GI Pipe medium grade shall be fixed both side of board with 2 Nos 30 mm x 4mm thick MS flat of 0.2 Mtr length welded to GI pipe and nut bolt and washer with display boardnot less than 2.5 Mtr and PCC 1:4:8 for foundation including all internal wirings and illuminated with LED 40 W Tubelightfitting 01 No, SMC/FRP Junction Box 140mm x 140mm x 95mm inner dimension make Sintex/National, the board must be openable from back side for maintenance of tube light, control wiring etc. Make : Bajaj Cat Part No BCLAB 20W /Wipro/Havells including its fixing arrangement and written Letters in capital not less than 10 letters and more than 40 letters, size of letters proportion with overall size of board complete all as specifiedand as directed. Note : (i) Before manufacturing Boards drawing and design of Board including colour of board shall be approved by Engr-in-charge.(ii) Each board display name shall be given seperately. |
| 112 | Supply only bamboo Ladder suitable for climbing upto 7.0 Mtr height complete all as directed.Make : as per sample. |
| 113 | Supply and application of Self Adhesive PVC Electrical Insulation Tape, capable of withstanding temperatures up to [100] °C, Dimensions 7.5 m x 18mmx 0.125mm, for insulating high-temperature electrical connections of superior quality complete all as directed. |
| 114 | Labour for cleaning the 3 mtr sarrounding area of LT Panel/Feeder Panel/Bus Bar Panelby removing/cutting out from roots oftrees, bushes & sepplings etc and thrown away the same atleast 100 mtr away from the site complete all as directed |
| 115 | M&L in replacement of mild steel plates , plain or chequered, 5mm thick or over cut,welded as reqd for closing cable ducting complete all as specified and as directed |
| 116 | M&L for PCC 1:2:4 type B1 with 20 mm graded well burnt brick aggregate forcoping, topping of plinth of panels, repairing / making connected path to panels/ transformer etc as directed |
| 117 | Supply & Fix in replacement of including installation and commissioning ofdigital automatic timer switch distribution panel board, factory assembled in powder coatedsteel sheet enclosure, comprising of 4P MCB, 40 Amps &3 Pole power contactor40/50 Amps and 230V digital time switch for controlling LED street lights,including earth work for fixing Timer switch distribution panel board and shall be provided 4 Nos 20x20x3mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth complete all as specified and directed |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy