Tender For Renovation Works Of The Kerala State Co-Operative Bank, Regional Office Building, Kottayam - Phase Ii (Civil , Furnishing , Electrical & Ac), kottayam-Kerala

Kerala State Co-Operative Bank Ltd has published Tender For Renovation Works Of The Kerala State Co-Operative Bank, Regional Office Building, Kottayam - Phase Ii (Civil , Furnishing , Electrical & Ac). Submission Date for this Tender is 17-10-2025. Building Work Tenders in kottayam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

51325666
Tender For Renovation Works Of The Kerala State Co-Operative Bank, Regional Office Building, Kottayam - Phase Ii (Civil , Furnishing , Electrical & Ac)
Tender
Indian
Kerala
Kottayam
17-10-2025

Tender Details

Tender For Renovation works of the Kerala State Co-operative Bank, Regional Office Building, Kottayam - Phase II (Civil , Furnishing , Electrical & AC)-- 1 FURNISHING WORKS - A. BANKING AREA - Glazed door : Providing and fixing entrance door using 12 mm toughned glass including floor springswith all necessary patches and Glass to glass lock round type (w/o cut out) patches for hanging the toughned glass ,etc complete. The door should have SS H-type (25x425mm)door handles on both sides. All Edges of the glass to be polished and Provide Rubber beading,The emblem and sticker works are as per the detailed drawing. 2 Frameless glazing:- Providing and fixing frame less glazing using 12 mmtoughned glass with all necessary patches for hanging the toughned glass as per detailed drawing. The emblem and etching works are as per the detailed drawing. 3 Full height Partition both side lamination :-Providingfull height partitions with hard woodframes of size 5 x 5 cm vertically and horizontally at 60 cms spacing, or at closer intervals as per site conditions, 6 mmBWR 303 grade ply and 1 mm laminate (in two colours as per design) of approved makeon both sides of partition and provision for access doors wherever required in matching pattern . 4 Half glazed and half paneled full height partition:- Providing full height partitions with hard woodframes of size 5 x 5 cm vertically and horizontally at 60 cms spacing, or at closer intervals as per site conditions, 6 mm BWR 303 grade ply and 1 mm laminate (incolours as per design) on both sides upto100 cms high, glazing from +100 to 210 cms level with 12 mmbevelled glass with emblem and sticker works and door.Glazing to be in big panels as per design wherever required.Glass to be fixed with polished decorative teak wood beadings.Necessary holes must be made in the frame sections to run the wires ,computer cables wherever necessary. Similarly necessary cutting to be made in the plywood surface to fix switch boxes of electrical, telephone sockets,computer information outlets etc. Door to be done in same manner. Size: 75cmx210 cm with Cylindrical locks, SS Tower bolt , SS Hinges, door closure & stopper.(Measurment for payment only up to bottom of false ceiling. Main section of partition will go up to the bottom of RCC slab) 5 Full height partition one side mica:- Providing full heightpartitions with hard woodframes of size 5 x 5 cm vertically and horizontally at 60 cms spacing, or at closer intervals as per site conditions, 6 mm BWR 303 grade ply and 1 mm laminate (in colours as per design) on one side and 2 coat enamel painting over one coat primer on other side.wooden preservative to be applied on the wooden frame before fixing the plywood.Providing provision for access doors wherever required in matching pattern. Necessary holes must be made in the frame sections to run the wires ,computer cables wherever necessary. Similarly necessary cutting to be made in the plywood surface to fix switch boxes of electrical, telephone sockets,computer information outlets etc. Door to be done in same manner with vision panel of size 45 X 45. Door Size: 90cm x 210 cm with Cylindrical locks,SS Tower bolt, SS Hinges, door closure & stopper. 6 Hollow Core Drywall partition:- Providing & fixingEverest hollow core drywall system using 51mm wall framing systems as core with 10mm thick Fibre cement boards fixed according to company specifications including additional frames for fixing doors. The partition should withstand its weight. The joints shall befinished with putty to appear jointless. The partition shall be finished with good quality a coat of primer 2 coatpainting etc.complete. The partition shall be extended upto true ceiling or bottom of beam. 7 Low height partition:- Providing and fixing 120 cms high partition with wooden frame of size 5 x 5 cm vertically and horizontally at 60 cms spacing, or at closer intervals as per site conditions.6 mmBWR 303 grade ply wood and 1 mm laminate (in 3 colours) on both sides upto + 90 cms level, 12 mm plain glass with slits,etching and edge polishing from + 90 to + 120 cms level, .Glass to be fixed with polished wood beadings. Access doors with 7.5 x 4 cm hard wood frames matching with fixed partition,locks all best quality fittings, brass hingesetc. to be provided where requied.Exposed sides of hardwood frames to be covered with 6 mm marine ply and 1 mm laminate.necessary provisionfor electrical switches may be provided. 8 Front Glass:-Providing and fixing12 mm plain glass withedge polishing. Glass to be fixed with polished wood beadings.The emblem and sticker works are as per the detailed drawing. 9 Semi glazed Aluminium door : Providing and fixingdoor using 10 mm glass and Particle board. 100x40x2.4mm (1.867kg/m) aluminium section on 4 side and middile up to 120cm height including all best quality hardware, brass hinges,mortice lock with cylindrical lock etc;. complete 10 Panelling:- Providing panelling to walls and pillars with 5x3 cm wooden frames at 60 cm c/c horizontally and vertically, 12 mm marine ply and 1 mm laminate, as required etc. complete.Lamination to be in 3 colours as per design. 11 Clerical Counter:- Providing table type clerical counters 75 cms wide, 75 cms height, with table top, ,vertical dividers on both sides of drawer units and between counter seats all in 19 mm BWR 303 Grade plywood.5x3 cm wooden frame to be given horizontally below inner edge of counter top for the entire length of the counter. 2 dia SS pipe to be provided as footrest. and necessary plywood frame work for drawer units to be given.Each seat (about 150 cm to 165 cm wide) to have key board tray and wire manager, One drawer and one storage spacewith Godrej make multi latch locks,Recessed Handle(Shutter Handle -Aluminium 3012 Square) (Ebco/eqlt). Key board tray with 19 mm BWR 303 Grade ply and 1 mm laminate etc. Drawers to have Ebco brand telescopic drawer slides.Counter top to be finished with 1mm thick laminate of approved colour and 8mm thickglass . All external surfaces 1 mm laminate finish and internal surfaces finished with two coats of enamel paint over two coat of primer & one coats of putty.Front vertical side of counter to be provided with two coloured lamination as per design etc. complete. 10mm thickwooden lipping for allexposed plywood edges. 12 False ceiling:-A) Providing seamless false ceiling with GI frame work and 12.5 mm thick gypsum board sheets, as per standard specifications of M/s.Gypsum India Limited for horizontal and vertical surfaces including providing cutouts for light fittings, painting with 2 coats of plastic emulsion paint over primer and putty etc. complete 13 Grid type false ceiling :- Providing & Fixing of grid type false ceiling with armstrong tile,Model: Classic Lite RH99 Armstrong. (Classic Lite tiles with Rivel edge black groove grid frames) and armstrong suspension system as per standard specifications of Armstrong world industries includingproviding cutouts for light fittings,etc. complete 14 Tables:-Providing table with 60 cms wide, 75 cms height, with table top,5x3 cm wooden frame to be given horizontally below inner edge of counter top for the entire length of the counter. Providing 10mm thickwooden lipping for all plywood edges. Wooden foot rest of 7.5 x 3 cm size and necessary plywood frame work for drawer units to be given.Each seat (about 150 cm to 165 cm wide) to have key board tray and wire manager, One drawer and one storage spacewith Godrej make multi latch locks,Recessed handle (Shutter Handle -Aluminium 3012 Square) (Ebco/eqlt).Key board tray with 19 mm BWR 303 Grade ply and 1 mm laminate etc.Top of the table should be with 1mm laminate and 8mm glass. Drawers to have Ebco brand telescopic drawer slides.Counter top andall external surfaces finished with 1 mm laminate and internal surfaces finished with two coat of primer & one coats of putty & two coats of enamel paint.Front vertical side of counter to be provided with two coloured lamination as per design etc. complete. 14 (a)Managers table of size 220x 80 cms with 3 drawers as detailed above (without side unit) 15 14 (b) Managers table of size 180x 80 cms with 3 drawers as detailed above (without side unit) 16 14 (c) Officers table of size 150 x 60 cms with 1drawer and 1 storage space as detailed above (without side unit) 17 Side unit for table:- Providing table side unitwith 19mm BWR 303 grade ply for top,intermediate shelf,three vertical sides, sliding doorsand 9 mm ply wood for rear side.All external surfaces andtop including rear side with 1 mm laminate finish , all fixtures, Godrej locks nylon bushes,Recessed handle (Shutter Handle -Aluminium 3012 )(Ebco/eqlt) , wooden lippingsetc. complete.All internal surfaces finished withtwo coat of primer & one coats of putty over two coats of enamel paint.17(a) 100x45x75 cm size 18 17( b)100x45x75 cm size 19 Door closer: Supplying and fixing everite make hydraulic door closer including cost and conveyance of all materials, labour charges for fixing, etc. complete as per directions of site incharge. 20 Pantry Counter :- Providing table type pantry counters 60 cms wide, 75 cms height, with table top, front apron, vertical dividers19 mm BWR 303 grade plywood.5x3 cm wooden frame to be given horizontally below inner edge of counter top for the entire length of the counter.Wooden foot rest of 7.5 x 3 cm size .Counter top to be provided with 20 mm edge bevelled and edge polished granite (jet black). All external surfaces 1 mm laminate finish and internal surfaces with enamel finish. 10mm thick beach wood lipping for all plywood edges. 21 Substafftable :- Providing table type counters 60 cms wide, 75 cms height, with table top, front apron, vertical dividers19 mm BWR 303 grade plywood.5x3 cm wooden frame to be given horizontally below inner edge of counter top for the entire length of the counter.Wooden foot rest of 7.5 x 3 cm size . Counter top to be finished with 1mm thick laminate of approved colour and 8mm thickglass.All external surfaces 1 mm laminate finish and internal surfaces with enamel finish. 10mm thick beach wood lipping for all plywood edges. 22 Dressing table -Supply/ installing wall mounted dressing table with glass mirror as per detailed drawing. Outer sides should be laminated and inner sidespainted withtwo coats of enamel paint over a coat of primer & two coats of putty. (Size of table with mirror-50x45x140) 23 Roller blinds :- Supplying and providing roller blinds with smooth operations using manual and clutch roller controlled by a continuous cord loop . The blind is to be fixed within the window opening .The fabric shall be of sunscreening quality and of approved shade .Top Roller and bottom roller of powder coated Aluminium ( Make Marvel/ Vista)(Basic material rate -170/SFT) 24 NOTICE BOARD - Providing and fixing pinup boards. It consist ½” soft boards of good density to be mounted over19 mm thick BWR grade plywood. The soft board will be covered with a plain fabric (appox Rs.150 /Rmts.) from front and edges. Suitable moulding (as directed by architect) will be fixed on all four sides and will be finished in polish. (Note : Only soft bords provided on other than the partitions will be measured and soft board made in the partitions will be the part of the partition measurement (rate) and not consider separately.) 25 Full Ht./Low Ht. Laminated Storage - Fabricating and fixing 45cm deep storage unitconstructed out of 19mm. Thk BWR.ply sides and 19mm thick shutters-side hung with 1mm laminate, 12mm.thk hHW lipped BWR.ply bottom with SS Hinges. Exposed edges should be provided with wooden lipping. All external surfaces andtop including rear side with 1 mm laminate finish , all fixtures, Godrej locks, Recessed handle(Shutter Handle -Aluminium 3512 ) (Ebco/eqlt),nylon bushes, wooden lippingsetc. complete.All internal surfaces finished withtwo coat of primer & one coats of putty over two coats of enamel paint. 26 Floating glass shelf for trophy in Managers room :- Providing 12mm thk edge polished glass shelves of size 100cms length and 20cms width fixed to the Back wall in Managers cabin using adjustable glass shelf supports of SS finish (EBCO/eqlt) The spacing between the glass supports shall be 40cms or as per manufacturers specification. 27 External ACP Cladding:- Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 basedPVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. 28 Dining Table :- Providing table 75cms wide,120 CM Length 75 cms height, with table top, vertical dividers19 mm BWR 303 grade plywood.5x3 cm wooden frame to be given horizontally below inner edge of table top for the entire length of the Table.Wooden foot rest of 7.5 x 3 cm size .Table top to be provided 25mm BWR GRW Grade ply with 6 mm corian finish. All external surfaces 1 mm laminate finish and internal surfaces with enamel finish. 10mm thick beach wood lipping for all plywood edges. 29 CIVIL WORKS -Dismantling existing False Ceiling , partitions, counters / tables after stage wise progress of work and stocking of serviceable material and disposal of unserviceable material from the site as directed by the bank official. 30 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material from the site. 31 Demolishing R.C.C. work with Tiles manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material from the site. 32 Demolishing wall Tiles, skirtingscreed manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material from the site anddamaged portion of plastering remove and replastering-as per Banks/ Architects direction. 33 Dismantling and removing existingPlastering Manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material from the site. 34 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. completemanually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material from the site. 35 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). - Second class teak wood 36 Repair work for Existing windows, door, change damaged glass and Damaged fittingincluding all best quality hardware, hinges and locketc. complete. 37 Providing and fixing 25 mm thick Fully panled Superior class teak wood door shutter including all best quality hardware, hinges and lock with necessaryscrews.etc. complete. 38 Providing and fixingglazed UPVC windows, ventilators and partition etc. with 5 mm thick clear float glass. White colour SH Handle, SS Friction Hinge and SS Espag Material , as per specifications, drawings and direction of Engineer-in-charge complete. ( Windows w4 3x1.8x1.5,W2 1x1.2x1.5,Kw2 1x1.2x1.00,V3x.6x.45) 39 Providing and fixing M.S. grills of using 12mm Dia steel rods spaced at 10cmC/C bothways to form mesh and welded together required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc. 40 Proposed Light weight Brick work , including scaffolding, curing, etc. 41 Brickwork withsolid blockof 30x20x15cm size, including scaffolding, curing, etc. for walls - Above plinth level upto floor V level. 42 CEMENT PLASTER (IN FINE SAND) -12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) 43 Vitrified Tliles Flooring: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on min. 20mm (or thickness to make floor level as per site conditions & requirement) thick cement mortar 1:4 (1 cement : 4 coarse sand) set in cement slurry or Gum and pointing the joints to correct lines and levels with 3mm spacer with Epoxy Grout , mixed with matching pigment, etc. The rate shall include for making boarder/ inlays of desired width/ dimensions using different shade of tiles if necessary as directed, cost and conveyance of all materials to site, labour charges for laying, loading and unloading, charges for cutting and finishing to the required level/line etc. including cleaning the surface with cleaning solution etc. all complete as directed by Bank Engineer , including grouting the joints with white cement and matching pigments etc., complete. basic price :- Rs 90/sqft - Size of Tile 600x1200 mm 44 Vitrified floor tiles Skirting: Preparing the surface of the walls to receive the new skirting by watering and cleaning, providing and fixing 100 mm height skirting cut out of vitrified tiles of approved make, size and shadefullyover a back plaster of CM 1:4 (using approved quality M. sand and OPC) for the required thickness, true to plumb and line, set with grey cement paste and joint pointed with tile grouts of approved make and quality to match with the shade of the tile. The rate shall include machine grinding and buffing of the exposed edges / sharp corners, machine cutting, curing, cleaning of the finished work, all leads & lifts, etc required for the finished work all as directed by the Banks Engineer 45 Providing and layinganti-skid vitrified floor tiles 600x600 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make and colour (Exact shade to be got approved by the Bank), laid on min. 20 mm thick Cement Mortar 1:4 (1 Cement : 4Coarse sand) Anti-skid Vitrified tiles of required size, approved quality and make (Exact shade to be got approved by the Bank) set in cement slurry and pointing the joints to correct lines and levels with 3mm spacer with Epoxy Grout , mixed with matching pigment, etc. The rate shall include for making boarder/ inlays of desired width/ dimensions using different shade of tiles if necessary as directed, cost and conveyance of all materials to site, labour charges for laying, loading and unloading, charges for cutting and finishing to the required level/line etc. including cleaning the surface with cleaning solution etc. all complete as directed by Bank Engineer including pointing the joints with white cement and matching pigment etc., complete. basic price :- Rs 70/sqft 46 Providing and fixing Ist quality vitrified glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shadesof any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in 3mm spacer with Epoxy Groutwith pigment of matching shade complete. basic price :- Rs 70/sqft 47 Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. 48 WATER PROOFING -Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand)mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) 49 PAINTING WORK - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface 50 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 51 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade- Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats. 52 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture 53 Polishing on wood work with ready made wax polish of approved brand and manufacture : old work 54 ELECTRICAL WORKS : DISTRIBUTION BOX AND CABLE- MAIN VDB - Supply and installation of sheet steel, phosphatisedandpainted,dustandvermin proof enclosure of 8 way (8+18 -double cover TPN vertical DB with provision for fixing FP MCCB as incomer and SP/ TP MCB as outgoings (IP 42/43) including copper /brass bus bar, neutral link, earth bus and DIN rail suitable forfixingMCB/ isolatoretc.fixedonwall using suitable anchor bolts or fixed in recess includingcuttinghole onthe wall , making goodthedamages,colourwashingetc.as required Conforms to IS 8623 - 1&3, IEC 61439 - 1&3. 55 MAIN Incomer - Supplying and fitting 100A 4P 35kA 415V 50Hz MCCB with Thermal Magnetic Protection Unit conforming to IS60947-2 & IEC 60947-2. 56 Outgoings - Supplying and fitting 63A 3P 415V 50Hz MCB 10kA C curve conforming to IEC 60947-2. ForPDB /AC DB & SPARE 57 Supplyingandfitting40A3P415V50Hz MCB 10kA C curve conforming to IEC 60947-2 For 3phaseLDB/ATM 58 Supplyingandfitting32/16ASP240V50Hz MCB 10kA C curve conforming to IEC 60947-.For board Ligth, Inverter & UPS -1 & UPS -2 59 A/CVDB - Supplyandinstallationchargesof3phase 6way(8+12)DBenclosurewithbusbars, neutral link earth bus and din rail suitable for fixing 4P MCB AND RCCB as incomer and SP MCBasoutgoingsIP43includingcopper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB etc. fixed on wall using suitable anchor bolts or fixed in recess includingcuttinghole onthe wall , making goodthedamages,colourwashingetc.as required Conforms to IS 8623 - 1&3, IEC 61439 - 1&3. 60 Incomer - 63A 4P RCBO (100mA)conforming to IEC/EN 61009 2010 61 Outgoings - Supplyingandfitting10/16ATPN230V50Hz MCB 10kA C curve conforming to IS/IEC 60898 -1 2002. For power plugs 62 Supplyingandfitting20/25ASP230V50Hz MCB 10kA C curve conforming to IS/IEC 60898 -1 2002. For single phase A/C Units 63 Supplyingandfitting20/25/32ATPN230V50Hz MCB 10kA C curve conforming to IS/IEC 60898 -1 2002. For Three phase A/C Units 64 LDB - Supply and installation charges of 3 phase 4 way(8+12)DBenclosurewithbusbars, neutral link earth bus and din rail suitable for fixing 4P MCB AND RCCB as incomer and SP MCBasoutgoingsIP43includingcopper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB etc. fixed on wall using suitable anchor bolts or fixed in recess includingcuttinghole onthe wall , making goodthedamages,colourwashingetc.as required Conforms to IS 8623 - 1&3, IEC 61439 - 1&3. 65 Incomer - 40A (30mA) 4P RCBO conforming to IEC/EN 61009 2010 66 Outgoings - Supplying and fitting 10/6A SP 240V 50Hz MCB 10kA C curve conforming to IS/IEC 60898 -1 2002. 67 UPS - UPS INPUT & OUTPUT:- SITC 32 A DP MCB in metallic enclosure 68 UPSOUTPUT SUBDB -1:SupplyandinstallationchargesofSingle phase12way(I/C+O/G)DBenclosurewith bus bars, neutral link earth bus and din rail suitable for fixing 2P ISOLATOR as incomer andSPMCBasoutgoingsIP43including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts orfixedinrecessincludingcuttingholeon the wall , making good the damages, colour washing etc. as required Conforms to IS 8623 - 1&3, IEC 61439 - 1&3. NOTE: The complete alarm systems , CCTV& Fireconnections must be taken from UPS DB -1 such a way that it ensures continuous and uninterrupted power supply 69 40A 2P HI RCBO (30mA) - 1no as incomerand followingas out goings 70 10A SP MCB( for CKT & Spare) 71 UPSOUTPUT SUBDB -2:SupplyandinstallationchargesofSingle phase12way(I/C+O/G)DBenclosurewith bus bars, neutral link earth bus and din rail suitable for fixing 2P ISOLATOR as incomer andSPMCBasoutgoingsIP43including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts orfixedinrecessincludingcuttingholeon the wall , making good the damages, colour washing etc. as required Conforms to IS 8623 - 1&3, IEC 61439 - 1&3. 72 40A 2P HI RCBO (30mA) - 1no as incomerand followingas out goings 73 10A SP MCB ( for CKT & Spare) 74 INVERTER- INVERTER CIRCUITSupply, Installation, testing and commissioning of Inverter input & output using 3 x2.5sqmm 1100V, PVC insulated FRLSH Copper conductor through PVC Conduit .Rate shall be for the average length from VDB to inverter charging, then to inverter input, from inverter output to inverter discharging & connection to change over and to inverter DB.No claim for additional wire and conduit. Following isolators to be provided for inverter charging (input)and discharging (output) - (a) 25A DP ISOLATOR inmetal enclosure for inverter charging 75 (b) 25A DP ISOLATOR inmetal enclosure for inverter discharging 76 SITC of 25A 2P MCBType manual Change over switch In metal enclosure with necessory fittings 77 CONTROL SWITCH (CCTV):-SITC of 16A Modular switch box with socket and MCB 78 LIGHTING DB CUTOFF -Supply, Installation, testing and commissioning 40A 4P MCB IN 4 WAY SPN DB AT ENTRANCE OF BRANCH 79 AC DB CUTOFF -Supply, Installation, testing and commissioning 63A 4P MCB IN 4 WAY SPN DB AT ENTRANCE OF BRANCH 80 INVERTER DB : SupplyandinstallationchargesofSingle phase12way(I/C+O/G)DBenclosurewith bus bars, neutral link earth bus and din rail suitable for fixing 2P ISOLATOR as incomer andSPMCBasoutgoingsIP43including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts orfixedinrecessincludingcuttingholeon the wall , making good the damages, colour washing etc. as required Conforms to IS 8623 - 1&3, IEC 61439 - 1&3. 81 40A 2P RCBO (30mA) as incomer 82 10A SP MCB 83 Supply &Installation of SURGE PROTECTION DEVICE (TVSS ) -Surge protection device(AC) 3P+N, In-20Ka,Imax -40kA,Up-less than or equal to 4.5kV ,with indicator conforming to IEC/EN 61643-11 84 POWER CABLE: Supply & laying of XLPE insulated PVC innersheathed aluminium conductor, 1.1 kV grade armoured power cables conforming to IS:7098, as per approved make in ground/ trench/surface/wall/pipe - (a) 4x35 Sq.mm XLPE as incoming cable MSBto VDB 85 ( b ) 4x10 Sq.mm XLPE VDB to Light Cutoff and return to LDB 86 ( C ) 4x16 Sq.mm XLPE VDB to AC DB Cutoff and return to AC DB 87 ( d ) 2x4Sq.mm XLPE 88 CABLE TERMINATION : Supply and installation (SITC) of End termination of the following size of cables using flange type cable glands and heavy duty tinned aluminium crimping type cable sockets including gland earthing. ( a ) 4x35Sq.mm XLPE 89 ( b ) 4x16Sq.mm XLPE 90 ( c ) 4x10 Sq.mm XLPE 91 ( d ) 2x4Sq.mm XLPE 92 Supply & laying of 4 x 6sq. mm stranded PVCinsulated copper wire through 20mm Rigid PVC condute. 93 WIRING FOR LIGHT, FAN, PLUG SOCKETS, UPS & EARTHINGOF BRANCH -COLOUR CODING AS PER IS 732 STANDARD. R Phase - RED COLOUR,Y Phase - YELLOW COLOUR, B Phase - BLUE COLOUR. WIRING SYSTEM - Circuit Mains-SITC of all materials and wiring for circuit mains from LDB to Switch Boards, using 2.5 sq mm 1100V, PVC insulated FRLSH Copper conductor for phase , neutral includingearthingwith1 run of 2.5 sq.mm green copper wirecontinuous run thorough 25 mm PVC conduit as per IS, giving inter connection etc complete as required and as directed by engineer in charge.Rate shall be for the average length from LDB to the switch board.No claim for additional wire and conduit. Item Rate 94 Lightand Exhaust fan Points -[SITC of all materials and wiring forlight and exhaust fan points using color coded 1.5 sq.mm 1100V grade, FRLSH, PVC insulated stranded copper conductor single core stranded wires of IS 694 specification and should have IS marking, through ISImedium grade20mm rigid PVC conduits concealed in wall / slab/ceiling etc,complete with necessary accessories, including supplying and fixing 6A modular type switch housed in a suitable factory made M. S box with moulded front plate including earthing the box, ceiing rose, connectors (of approved make) etc., complete as required.(The rate include removing debris, packing and rough plastering the grews after conduiting) ] Single control light Point / Exhaust fan point (one light/fan controled by one switch) - Item Rate 95 Group Control Wiring (Lights) - (a) Two lights controlled by one switch - Item Rate 96 (b) Three lights controlled by one switch - Item Rate 97 (c)Four lights controlled by one switch - Item rate 98 Supplying all materials and wiring for ceiling fanpoints with 250 Wstepped type electronic regulator using 1.5sq.mm, FRLSH PVC insulated stranded copper conductor single corestrandedcolor coded wires of 1100V grade and 1 run of 1.5 sq.mm green copper wirefor Phase , nuetral &earthing continuously run as per IS through ISImedium graderigid PVC conduits concealed in wall/slab/ceilingetc., complete with necessary accessories, including supplying and fixing 6A modulartype switch and 250W electronic fan regulator housed in a suitable factory made M. S. box with moulded front plate including earthing the box,complete as required.(The rate include removing debris, packing and rough plastering the grews after conduiting) - (a) Ceiling fan point - Item Rate . 99 (b) Wall fan point (same as above ) with 6A socket but without electronic regulator - Item Rate 100 PLUG SOCKETS - (a) Supplying all materials and wiring for 6A plug points in independent positions using 1.5 sq.mm 1100V, FRLS PVC insulated copper conductor single core stranded wire for phase & neutraland earthing with1 run of 1.5 sq.mm green copper wireinside the conduit / flat conduit,and fixing 6A modulartype plug socket (2 in 1) controlled by 6A switch with moulded front plate, housed in a suitable factory built MS box.Giving connections, earthing etc complete as required. Item Rate 101 (b) Supplying all materials and wiring for 6A plug points in combined positions using 2 runs of 1.5 sq.mm 110V FRLS PVC insulated copper conductor single core stranded wire, earthing with earthing with1 run of 1.5 sq.mm green copper wireinside the conduit/flat conduit ,and fixing 6A modulartype plug socket (2 in 1) controlled by 6A switch with moulded front plate, housed in a suitable factory built MS box.Giving connections, earthing etc complete as required. (in SB) - Item Rate 102 (c) Supplying all materials and fixing modular type 16A power plug pointwith 16A 3 pin modular type plug socket controlled with16A switch withmoulded front plate, housed in a suitable factory builtMS/PVC box using 2 runsof 2.5 sq mm 1100V , FRLSH PVC insulated stranded Copper conductor includingearthingwith1 run of 2.5 sq.mm green copper wirecontinuous run thorough 25 mm PVC conduit as per IS, giving inter connection etc complete as required and as directed by engineer in charge. as per IS, giving inter connection etc complete as required. Rate shall be for the average length from DB to the switch board.No claim for additional wire and conduit.- Item Rate (NOTE: The Electrical Wiring inside the Strong Room should be in a CONDUIT and POWER CUT OFF SYSTEM either AUTO/ MANUAL PLUG SYSTEM drawing power only from the Limit Switch in case of Auto Power Cut Off System is provided in the Door OR from the FEEDER BOX fitted outside the Strong Room (near the door) in case of Manual Plug System. The MANUAL PLUG SYSTEM OF POWER CUT OFF should be such that the connecting cable passes through the Strong Room Defender Door from inside to outside, which should be accessible only after opening the S.R.door (thus ensuring that the door can not be closed withoutremovingthe plug + wire and hence total power inside the Strong Roomis cut off leaving no chances of fire resulting from anElectrical source / High Voltage / Surgingeven with the Switches in Off position). Inverter & KSEB Power inside strong room should be provided through two separate plug and socket arrangements.) 103 Computer power point - UPS power stations - (a) Supplying all materials and fixing modular type 3numbers 6A, 3 Pinsockets controlled by one number 16A SP control indicatorswitch with moulded front plate, housed in a suitable factory built MS/PVCbox 104 (b) SITC of all materials and wiring for circuit mains from UPS Sub DB to work station using 2 runs of 2.5 sq mm 1100V, FRLSH PVC insulated stranded Copper conductor includingearthingwith1 run of 2.5 sq.mm green copper wirecontinuous run thorough 25 mm PVC conduit as per IS, giving inter connection etc complete as required and as directed by engineer in charge. etc complete as required .Rate shall be for the average length from DB to the primary switch board and looping to adjacent switch boards. No claim for additional wire and conduit. (Maximum 2 points from 1 Circuit) 105 1 TonA/C Point - Supplying all materials and fixing modular type 20 A power plug pointwith 20A 3 pin socket controlled with 20 A DP modular switchwith moulded front plate, housed in a suitable factory built MS box using 4 sqmm 1100 V, FRLS PVC insulated strandedCopper conductor and earthing with 4 sqmm green Cu wire continously run through25 mm PVC conduit as per IS giving inter connection etc complete as required.(AC point) the switch shall be fixed at a height of 120 cm from finished floor level .Rate shall be for the average length from DB to the switch board. No claim for additional wire and conduit. - Item Rate 106 CASSETTE AC POINT -Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 107 Weather proof IP 65 enclosure for AC outdoor control(to be provided after obtaining approval from Bank) 108 STABILIZER - Supply and fixing 20A plug socketWith plug top for AC Stabilizer 109 Board Light Point - Supplying all materials ,Wiringfor board light pointcontrolled by 20AELCBin metal enclosure using 2 runs4 sqmm 1100V FRLS PVC insulatedCoper conductor and earthing with 4 sqmm pvc insulated green Copper wire continously run through25 mm PVC conduitas per IS giving inter connection etc complete as required. Rate shall be for the average length from DB to theboard light .No claim for additional wire and conduit. (Board Light point for Branch) 110 Supply and fixing of Indicator Board at entrance of the building such that the indicator Board is visible on the CCTV footage ( RED for PDB , YELLOW or LDB , BLUE for UPS DB , GREEN for Inverter DB, & WHITE for Generator ON ) 111 SITC OF LIGHT FITTINGS AND FANS - (a) 36W LED FITTING- Supply and Installation of2x2 square LED ceiling flush mountedfitting of Wipro, Elate LED,CRCO10 112 (b) ROUND LED DOWN LIGHT FITTING Supply and Installation of LED ceiling fittingWipro Iris LED Slim Ro, LD80-171-XXX-60-XX 1x18W 113 (c) ROUND LED FITTING Supply and Installation of LED ceiling fittingWipro Iris LED Slim Ro, LD80-530-XXX-60-XX 1x9wor equivalent 114 (d) CALLING BELL Supply and Installation of Calling bellcontrolled by modular type bell push 115 (e)LED TUBE FITTING Supply and Installation of 1x18 W patty LED tube fitting on wall or ceiling Garnet led tube 4feet white 116 (f) LED BULB - Supply and Installation of 9W LED bulb on angle holder. 117 (g) WALL FAN Supply and Installation of400 mm sweepswivelling type wall fan Crompton Greaves High flo or equivalent 118 (h) EXHAUSTFAN Supply and Installation 150mm light dutyexhaust fan with all fittings 119 (i) EXHAUSTFAN Supply and Installation 300mm light dutyexhaust fan with all fittings 120 (j) CEILINGFAN Supply and Installation of 1200 mm sweepceiling fan with all fittings for the installation of Ceiling fan - Crmpton Greaves - white color 121 (k) LED STRIPSupply and fixing strip LED (Blue colour) for false ceiling with good quality driver unit (4A,12V adaptor for 5M ) Formes Led Wipro 122 EARTHINGSTATIONS -(a)Supply and installation of plate earthing satation conforming to IS 3043 using 600x600x3mm Copper plate eath electrode burried in ground, 20mm dia 3m long perforated GI pipe with funnel and constructing inspection chamber by masonry work with heavy dutyCI inspection cover including civil work complete for UPS. 123 (b) PIPE EARTH Supplying of all materials and providing earth point with pipe earthling waste pipe earthling strips, funnel etc. excavation trenches, filling with alternate layers of charcoal, salt ands sand, back filling as per BIS specifications and IS 3043/1987 124 EARTHINGCONDUCTORS - Supply and laying the following sizes of bare copper earthing conductors including termination,bracing the joints etc. as per standards. - (a) 2x10 SWG Copper through cables 125 (b) 1x8 SWG Copper for pipe earth 126 (c) 1x10 SWG Copper 127 EARTH BENCH Supply and fixingtinnedcopper earth bench (minimum 40cm length) 25x3 mm with all termination using cu sockets etc 128 Prepairing Drawing and completion report for KSEB incl. liasioning with office, submission & followup of application etc. 129 Supply & providing electrical grade rubber floor mats 130 Supply & providing cautin boards,Aluminium 105x105mm 131 Supply & providing electrical shock treatment chart (Three Languages -Hindi-English-Malayalam ) 132 Supply & providing First Aid Kit 133 TELEPHONE - Supply and wiring using 2 pair telephone cable in 20/25mm medium duty ISI PVC pipe with all necessary pvc accessories- (a) 2 pair telephone cabling 134 (b) Supply and fixing of RJ 11 type telephone socket on suitable PVC / metal boxes. (1) Telephone socket – single modular type 135 (2) Telephone socket – double modular type 136 (c) Supply, laying commissioning of 0.5 sq.mm 10 pair armoured telephone cable with all accessories 137 (d) Supply and installation of KRONE connector telephone junction box of 20 pair. 138 Dismantling Existing fittings, wiring after stage wise progress of work and stocking of serviceable material and disposal of unserviceable material from the site as directed by the bank official.And Making Temporary arrangement for UPS point, lighting and fan, data points for smooth banks functioning including cost of materials. (if any) 139 ELECTRICAL WORKS : TOILET BLOCK AND GUEST ROOM- POINT WIRING -(A) Supply and wiring light point according to IS 732-1989 in Existing PVCconduit with FRLS 1.5 sqmm PVC insulated standard single corecopper conductor 650 V grade including providing switch board main and continues earthing with FRLS1.5 sqmm PVC insulated standard single corecopper conductor 650 V graderequired qty. of copper earth socket brass bolt, nut, crimping/soldering etc. complete in Existing modular type metal switch boxesinnew modular type front plated (similar make of Metal Box) etc up to and incluidng 6 A modular type SP switches.All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed alongthe periphery of the box using suitable ties, tie mouts etc. as required. Also provide blanking plates where ever required .Single contorl light point with 6A, 3 plate ceiling rose( Cost of the Modular front plates & 6A switches & blanking platesare Included) (Make- 140 As per item (A)above butceiling fanpointcontroled 6A Modular type SP switches & step type Fan regulator with 6A, 3 plate ceiling rose( Cost of the Modular front plates ,6A switches & Regulatorsare Included) 141 As per item (A) above butExhaustfanpointcontroled 6A Modular type SP switches with 6A, 3 plate ceiling rose ( Cost of the Modular front plates & 6A switches are Included) 142 S & I of Geyser PointEach point consisting of 1 nos 16A of 3 pin sockets controlled by1 no of 16A Indicator Switch. Switch near the light switch box& socket near the Geyser ( 1 points from 1 Circuit)( Cost of the Modular Boxes,Modular front plates ,16A switch & 16A socket are Included) 143 CIRCUIT WIRING - Supply and drawing 650/1100 V grade PVC insulated stranded single core FRLS copper conductor cables conforming to IS 694 part I 1990 in the surface / recess conduit as required including giving necessary connections of the following sizes.2.50 sq mm 3 run including the cost of the conduit ( From DB to Geyser point ,DB to Light Switch Board & Switch board to switch Board) (Make- RR Kabel/ Finolex/Polycab 144 FITTINGS & FIXTURES - (a)Supply and Installation of 20 / 21W, 4 Feet LED Batten Light fitting with suitable mounting clips. Make: Philips/ Panasonic 145 (b) Supply and installation of Angle batten holder with9W Cool Day Light LED bulb on suitable PVC box 146 (c) Supply and installation of 10W Mirror Lamp 147 (d) Supply and installation of 9 size medium duty exhaust fan. (Toilets) Crompton / Almonard make 148 (e) Supply and installation of 1200mm Sweep ceiling fan (Crompton ,Bajaj) 149 (f) Supply and installation of electric geyserstorage capacity of 5 Liter ,withinner tank materialSS316 proper insulation thickness (PUF), heatingcapacity (2 kW), and performance ratings like BEE Star Rating. It also specifies the inclusion of accessories like a pressure relief valve, thermostat, NRV, and other safety features, along with requirements for testing, warranty, and compliance with relevant Indian Standards (IS) 150 AIR CONDITIONING WORKS - MACHINES - Supply, Installation, testing commissioning (including transportation) of inverter type air conditioners comprising of outdoor unit with SCROLL/ROTARY Compressor, isolating valve, copper condenser & evaporator coils, air cooled condenserfans, thermostatic control, safety cut-outs, vibration pads with single outdoor andIndoor unit with 3row cooling coil, 20Micron filter includingremote controller and ODU fins. Note: The Hi-Wall Split Air Conditioners unit should be of 5 Star Rated and Cassette ACs should be of minimum 3 star rated in energy efficiency as per Bureau of Energy Efficiency (BEE) Cost should include standard length of 3m copper pipe. Approved Makes: CARRIER, DAIKIN, BLUESTAR, MITSUBISHI, OGENERAL, VOLTAS, LLOYD. Make and Model Number to be specified in column given. Installation including all required accessories & with One or more times pressure testing with nitrogen at company specified psig for each unit, leak testing, rectification, vaccumisation, gas charging, testing & commissioning and balancing of each unit to satisfy that there are no leakages & satisfactory operations. Rate including ceiling/wall mounted suspension Kit etc complete - (a)1. 0 TR Hi-wall Splittype AC unit (Make- ) 151 (b) 3.0 TR Cassettetype AC unit (Make- ) 152 Supply and instllation of stablizer (make- V Guard )4KVA-MODEL VND 400 153 REFRIGERANT PIPING FOR UNITS – Supply, installation, testing & commissioning of suitable swg copper refrigerant pipingfor suction & return of suitable dia with complete fittings, elbow, bends, supporting arrangement (Make- Nissan, Merchant) MET tube, Totaline tube, pre pressure tested tube. The sizes given shall be verified by Supplier for adequacy and size based on manufacturer standards. (Standard length of 3 m not to be considered). Insulation – providing Nitrile rubber insulation 19mm thick class “O” closed cell fire retardant super Lan, Armaflex make (Standard length of 3 mnot to be considered). The sizes given shall be verified by Supplier for adequacy and size based on manufacturer standards.Rate to include insulation cost. (a) 1. 0 TR Hi-wall Splittype AC unit 154 (b) 3.0 TR Cassettetype AC unit 155 DRAIN PIPING - SITC of CPVC drain piping insulated out of 6mm thick closed cell nitrile rubber class material of approved make as per specification complete with supports, consumables, fittings, pipe sleeves, U trap & leak arresting of following sizes.finished with clad or poly shield covering. Complete as directed by Architect/Bank. Make- Finolex, Precision(a) 1. 0 TR Hi-wall Splittype AC unit 156 (b) 3.0 TR Cassettetype AC unit 157 ELECTRICAL CABLE - SITC of suitable electrical control cable of ISI Mark from Indoor to outdoor units for all the units. (Standard length of 5 m suppliednot to be considered). Make - Finolex, Polycab. (a) 1. 0 TR Hi-wall Splittype AC unit 158 (b) 3.0 TR Cassettetype AC unit 159 SUPPLY AND INSTALLATION OF MS POWER COATED STAND FOR OUTDOOR UNITS . (a) 1. 0 TR Hi-wall Splittype AC unit 160 (b) 3.0 TR Cassettetype AC unit 161 Rate for trenching of wall/ floor with covering the same with cement mortar 1:4 mix. In line level. Rate should be inclusive of making necessary holes including core cutting as required for taking out copper piping, electric cables upto the Outdoor AC Unit. Complete in all respects with finishing. 162 Removal of existing cassette /split AC units including copper pipe, drain pipe and other related items at stage wise progress of work and stocking of serviceble material and disposal of unserviceble material from the site as directed by the bank official. 163 CAMC - 1.0 TR Hi-wall Split Type AC Unit (a) CAMC For First Year AFTER ONE YEAR WARRANTY PERIOD 164 (b) CAMC For Second Year 165 (c) CAMC For Third Year 166 (d) CAMC For Fourth Year 167 CAMC - 3.0 TR Hi - Casatte type AC unit.(a) CAMC For First Year AFTER ONE YEAR WARRANTY PERIOD 168 (b) CAMC For Second Year 169 (c) CAMC For Third Year 170 (d) CAMC For Fourth Year 171 that the door can not be closed without removing the plug + wire and

Key Value

Document Fees
INR 2360 /-
EMD
INR 120000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail