| 1 | Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., completeall as specified and as directed. |
| 2 | M&L Pre- paintedhot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screwscomplete all as specified and directed. |
| 3 | M &L pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour as approved by AGE(I) having tensile strength of 550 Mpa as in ridges,valleycomplete all as specified and as directed. |
| 4 | S&F 0.63 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip, wall cladding and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 5 | Refixing only plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip, wall cladding and straight flashings (measured as the minimum rectangle from which the piece can be cut)complete all as specified and as directed. |
| 6 | S&F for 4mm thick,plywood, grade BWR,type BB, fixed with nails to timber frame workon wallincluding taking out old plywood of any description complete all as specified and as directed. |
| 7 | M&L for 2nd class hard wood, in scantlings, clean sawn timber as in un framed workand including dismantling timber scantling 40Sqcm and over in section as in unframed workin any position complete all as specified and as directed. |
| 8 | Demolition of brick or stone masonry work built in cement mortarincluding all quoins, arches, pillars etc complete all as specified and as directed. |
| 9 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 10 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and as directed. |
| 11 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 12 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thickmixed with water proofing compound (@ 3% by weight of cement or as per manufacture\"s instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note :Water proofing compoundwill be measured and paid separately as \"Supply only\". |
| 13 | Supply only integral water proofing compound complete all as specified and as directed. |
| 14 | M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 15 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cmthick ( Below or above ground)complete all as specified and directed. |
| 16 | M&L for providing 75mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection, surface finished even & smooth without using extra cement including provision of 10 mm joints (at an interval of 3 metre and turnings) duly filled with fine sand and bitumen in the ratio of 3:1, complete all as specified and directed. |
| 17 | M&L for 25mm thick cement concrete (1:2:4) type B-0(using 12.5mm graded crushedstone aggregates) as in sub basefloor concrete surface finishes even and smooth with using extra cement, complete all as specified and as directed. |
| 18 | M & L for colourednon-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc.over and including 15 mm thick screed bed or bedding layers in 15mm thick screed bed in cement motar 1:4, setand jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles,complete all as specified and as directed. |
| 19 | Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as directed. |
| 20 | M&L for glazed light coloured/printed ceramic tiles 350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thickscreed bed incement mortar 1:4 complete all as specified and as directed. |
| 21 | Taking down shutters of any description exc 1 sq. m and n exc 2 sq. m eachcomplete all as specified and as directed. |
| 22 | Taking down shutters of any description n exc 1 sq. m each complete all as specified and as directed. |
| 23 | Taking down chowkats orframe with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm complete all as specified and directed. |
| 24 | S&FFactory made 30mm thick flush shutter solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as specified and as directed. |
| 25 | S&F 30mm thick second class hard wood Glazed and skeletondoor/window shutters, open rebated andrepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR PartI, Section 8, clause 8.24 (a) complete all as specified and directed. |
| 26 | S&F factory made solid PVC door frame of size50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified and directed. |
| 27 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails, MS frames shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stills and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ scaled to the stiles and rails with suitable PVC Sheet beading and jointed together with solvent cement as per drawings and specifications as catered in SSR Part – II 2020 complete all as specified and directed. |
| 28 | S & F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed. |
| 29 | S & F 100 mm size butt hinges, heavy weight, cold rolled mild steel, and fixed, complete all as specified and as directed. |
| 30 | S & F 75 mm size butt hinges, heavy weight, cold rolled mild steel, and fixed, complete all as specified and as directed. |
| 31 | S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 32 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 33 | S&F 100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 34 | S&F 150mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed. |
| 35 | S&F 100 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed. |
| 36 | M&L forPCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified and directed. |
| 37 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends, complete all as specified and directed. |
| 38 | M&L for Preparing new zinc (or galvanised) surfaces to recieve painting , by coating with two coat of synthetic enamel paint over a coat of red oxided zinc chorome primer complete all as specified and as directed. |
| 39 | M&L for preparation of old painted steel surfaces of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints complete all as specified and as directed. |
| 40 | M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat ofprimer complete all as specified and as directed. |
| 41 | M&L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. |
| 42 | M&L for preparation of old wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paintscomplete all as specified and as directed. |
| 43 | M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 44 | M&L for preparation of old plastered surface of walls and applying two coats of cement base paint complete all as specified and as directed. |
| 45 | M & L for writing letters or figures with approved paint (Block, Roman, Italic or Indian) not exc. 30 cm high complete all as specified and as directed. |
| 46 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. |
| 47 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFR-LSH cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed. |
| 48 | All as per item serial No 47 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board. |
| 49 | Allas peritem serial No 47 here-in-before but for One 3 pin 5 Ampsocketon same board. |
| 50 | Allas peritem serial No 47 here-in-before but for One 3 pin 5 Ampsocket combination on independent board with other switches. |
| 51 | S & Fswitch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed. |
| 52 | S & Fswitch piano, flush type single pole one way 15 Amps 230 volt complete all as specified and as directed. |
| 53 | S & F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed. |
| 54 | S & Fswitch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 16 Amp flush type complete all as specified and as directed. |
| 55 | S&F in repairs, LED light fitting 1 x 9W / 1 x 10W blukhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 56 | S & Fceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed. |
| 57 | S & F lamp holder, insulated, PVC / polycarbonate /bakelite body cord grip cap suitable for pendent fitting complete all as specified and as directed. |
| 58 | S & F Lumino LED lamps 10W E27W ball lamp lumen output 1020lm3000K colour temp current 0.55 ampscomplete all as specified and as directed. |
| 59 | S & F MAXOLED batten with Maxo LED type 20W LED 6000K T8 LED lighting fixture with extruded polycabonate, environment friendly, energy efficient, 230V, 50Hzcomplete all as specified and as directed. |
| 60 | Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook, dismantling of blades and transporting from any location inside army area to MES E/M store yard and hanging the same carefully in hook and connecting up including provision of cable from ceiling rose or connector to ceiling fan complete all as specified and as directed. |
| 61 | S & F stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed. |
| 62 | S&Fin repair PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete all as specified and as directed. |
| 63 | S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar complete all as specified and as directed. |
| 64 | S&F MCBs, SPN/DP 40 Amps, 10 KA,\"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 65 | S&F MCBs, SP 6 to 32 Amps, 10 KA, \"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 66 | S&F 1100 volts grade heavy duty flat cable ofsize 10 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed. |
| 67 | M&L for house service GI bracket(Hook type) made out of 40 mm bore medium grade GI Pipe of length 3m andone No 90 degree bendfixing withclamps, nuts and bolts, MS hooks,stay etc,including dismantling old onecomplete all as specified and as directed. |
| 68 | M&L for plate earthing completewith galvanizedmild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrodeat one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm boreGIpipe medium gradewith all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I and including taking down of old ones, complete all as specified and directed. |