| 1 | Demolition of brick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc. complete all as specified & directed. |
| 2 | M&L old size brick work with sub classfly ash bricks straight or curved on plan exc 6 m mean radis built in CM 1:6 Complete all as specified and directed. |
| 3 | M&L old size brickwork with subclass `B\" bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks Complete all as specified and directed. Note :- Old serviceable bricks retrived from demolition shall be re-used under this item. |
| 4 | Demolition of cement concrete of ground floor n exc 15 cm in depthin any position nototherwise specifically provided for complete all as specified & directed. |
| 5 | Dismantling of Stone slabs, kota stone and tiles of any description or thickness in floors, apronslaid and pointed in any mortar etc complete all as specified & directed. |
| 6 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg)25 mm thick for Sub base flooring complete all as specified & directed. |
| 7 | M&L machine cut prepolished kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing uptoGranite finish complete over 15mm thick screed bed in CM 1:6complete all as specified & directed. |
| 8 | All as per item No 7 above but factory made bull nosed as in riser of steps, skirting/dadolaid over10mm thick in cm 1:4 complete all as specified & directed. |
| 9 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each complete all as specified & directed. |
| 10 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.50 Sqm & n exc 4 Sqm each complete all as specified & directed. |
| 11 | S & F for Factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madecomplete all as specified & directed. |
| 12 | S & F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65X100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madecomplete all as specified & directed. |
| 13 | S&F forsecond class hard wood factory made 35mm thickplain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 14 | S&F for 30 mm thick second class hardwood factory madeGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (b); supplied and fitted to chowkats complete all as specified and directed. |
| 15 | M&L Framed work such as grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290 Gde E-165 complete all as specified & directed. |
| 16 | M&L preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamelover one coat of red oxide primer complete all as specified & directed. |
| 17 | M&Lstainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or stainless steel wire staplescomplete all as specified and directed. |
| 18 | M & L Steel window box type using ERW \"P\" section comprising double frame for gauged and glazed skeleton shutter jointed internally with flat iron 40x3mm complete including hinges, handle tower bolts stops, lugs etc all as shown on drawing complete all as specified & directed. Note (i) For the purpose of measurement & payment double shutter with frame shall be considered as one unit (ii) Unit rate quoted against this item shall also include the iron mangeryas shown on drgs (iii) Guard bars glazing & wire mesh shall be measured & paid for separately. |
| 19 | Supply & fix steel windows or ventilators fixed type complete all as specified & directed. |
| 20 | Supply & fix 3mm thick sheet glass, ordinary quality, and glazing with oil putty/beading in square not exceeding 0.50sqm each pane complete all as specified & directed. |
| 21 | S&F aluminium slidingbolt 300 long bolt type with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified & directed. |
| 22 | S&F heavy weight butt hinges 100mm in sizecomplete all as specified and directed. |
| 23 | S&Faluminium anodised barrel tower bolt with bright bolt 200 mm long complete all as specified & directed. |
| 24 | Taking down of cement/limeplaster of any description & thickness from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc. complete all as specified & directed. |
| 25 | M & L 15 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and fair complete all as specified & directed. |
| 26 | M & Lfor applying 10 mm thick rendering in CM 1:4 on brick / concrete surfaces of external walls finished even and fiar, using water proofing compound @ 200ml per cement bag or as per manufacturer instructions, complete all as specified and directed.Note:- Water proofing compound shall be measured and paid seprately. (upto a height of 15.0m). |
| 27 | M&L For preparation of old surface /existing treatment by mechanical means complete all as specified and directed. |
| 28 | M&L preparation of new/old surface of of wall by applying 1mm thick wall care putty and making the surface smooth Finishing walls and applyingtwo coat of cement based paint complete all as specified and directed. |
| 29 | Demolition of reinforced concreteof any description and any poisition not otherwise specifically provide (reinforcement cut to faciliatate demolition) complete all as specified & directed. |
| 30 | M&L Form work to sides and soffits of beams lintels etc finishedrough complete all as specified & directed. |
| 31 | M & L RCC 1:2:4 Type B0 (using 12.5mm graded stone aggregate) as in beams, lintels, bressummers over 1.5 m span etc complete all as specified & directed. |
| 32 | M & L precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggegrate) as in Chullah hood chajja and manhole cover, kitchen shelves etc set in cement mortar 1:4.including all neccesary formwork & finishing exposed concrete surface complete all as specified & directed. |
| 33 | S&F mild steel TMT bars No 500D 10mm dia and over, cut to length bent to shape requiredincluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including MSwire (annealed) not less than 0.9mm dia or securing clips complete all as specified and directed. |
| 34 | ditto as per item no 33 abovebut 6 to 8 mm dia complete all as specified and directed. |
| 35 | M & L for cutting of bushes small trees (Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet etc at any height by necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and incl material and labore in CM 1:4 mixed with WPC /PCC 1:3:6 type B0 /Bk work in CM 1:4 as required at site and as directed by Engr-in-Charge |
| 36 | Dismantling asbestos cement (corrugated, semi corrugated sheet etc) sheet in roof coverings complete all as specified & directed. |
| 37 | Supplied and fixed pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet (AZ-150) 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with hot dip galvanised self dirilling and self tapping screws neoprene and EPDM washers complete all as specified & directed. |
| 38 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/ridges etc, fixed with self tapping screws complete all as specified & directed. |
| 39 | Dismantling timber scantlings 40 sq.cm and over in section, in any position unframed work complete all as specified & directed. |
| 40 | Dismantling framed trusses in any position span n exc 10m complete all as specified & directed. |
| 41 | S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc including notching, drilling, fittings, riveting and / or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing fittings angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing conf to Fe-410-w (Gde-E -250) quality A complete all as specified and directed. |
| 42 | M&L for removal and refixing of rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, hollow pipes or flat sections) including distance pieces, cleats etc including notching, drilling, fittings, riveting and / or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing fittings angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing conf to Fe-410-w (Gde-E -250) quality A after grinding and preparation of old surface to make it functional complete all as specified and directed.(Note: Any member required to make functional the removed strcuture will not be paid separately. All rated are deemed to be included in the item for removal & refixing to make functional.) |
| 43 | S & F rolled mild steelplates ( plain on chequered) channels, square cutor notched (ordinary and counter sunk) forming holes without any attachment conforming to Fe 410 W (Gde E. 250) quality ‘A’ complete all as specified & directed |
| 44 | M&L for preparation of new/old plastered surfaces of wall by applying wall care putty averaging thickness 1mm and rubbing with sand paper for making smooth surface and applying two coat of oil emulsion distemper over one coat of primerthrough roller, complete all as specified and directed . |
| 45 | Material & labour for provisionof GI frame work (snap grid) suitable for size as in false ceiling of size 605mmx605mm including fixing 4mm thick gypsum board /E-board in ceiling size 60cmx60cm fixed to metallic snap grid consisting of following and all as directed including dismantling wall and ceiling boards or insulation boards/slabs any thickness including cover fillets.(i) Gi sections incorporated in frame work shall conform to designation given in IS: 737-1986. (ii) The snap grid shall conist of GI frame work main/cross tee of size 36.5mmx25mmx1.0mm thick and 25mmx25mmx1.00mm respectively. (iii) Snap grid frame shall be fixed to ceiling with supporting hangers consisting of Supply and fix 2mm to 4mm dia mild steel Gi wire. (iv) The main and cross tees shall be jointed at junction/crossings with GI frame work angle bracket, of size 15mmx15mmx1.0mm thick, fixed with suitable mild steel, bolts, nuts and washers all as per manufacturer\"s instructions. (v) The snap grid(main/cross tee section) shall be supported at ends all along the wall with Gi frame work angle of size 25mmx25mmx1.00mm anodized thick (vi) Size of the snap grid shall be 605mmx605mm. (vii) Minimum average thickness of anodizing shall be 15 micron. complete all as specified & directed. |
| 46 | M&L preparation of new or previously untreated wooden surfaces of any description, not other wise described over 10cm width or girth and apply two coat of synthetic enamel paint over and includinga coat of pink primer (by spraying) complete all as specified & directed. |
| 47 | Taking down carefully any type of battens or conduit point wiringwith conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from siteto match the existing complete all as directed by Engineer - in - Charge. |
| 48 | M&L for concealed point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FR-LSH, conforming to IS: 694-1990, PVC insulated, unsheathed copper conductorand including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, sunk zinc coated pressed steel terminal box 18G suitable for fixing moduler switches, sockets, regulator etc including modular inner frame and outer cover with continuous green earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulatedmulti stranded, FRLS copper conductor cable, unsheathed and connected to common earth and earth dolly including cutting holes in or through the walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed for One light point wiring controlled by one, one way switch/bell push button. Note :- The point wiring shall include the wiring of light/ outlets of any length from the distribution board via switch to the point. |
| 49 | -ditto- but one fan point control by one 1- way switch complete all as specified & directed. |
| 50 | -ditto- but security light point control by one 1- way switch complete all as specified & directed. |
| 51 | -ditto-but one out let socket point 3pin 5 ampson independent board complete all as specified & directed. |
| 52 | -ditto-but on the same board with other switches complete all as specified & directed. |
| 53 | All as per item No 51 abovebut using 2.5 sqmm copper conductorwith 2.5 sqmm earth wire for one 15 amps socket outlet on independent board complete all as specified & directed. |
| 54 | S&F Modular Switch, 1 module, 6A, AC, 240V, one way ISI Marked and complete all as specified & directed. |
| 55 | S&F Modular Socket, 2 module, 6A, 2/3 pin combined, AC, 240V, ISI Marked and complete all as specified & directed. |
| 56 | S&F Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, ISI Marked and complete all as specified & directed. |
| 57 | S&F Modular Switch, 1 module, 16A, AC, 240V, one way ISI Marked with indicator and complete all as specified & directed. |
| 58 | S&F 1 module modular blank plate complete all as specified and directed. |
| 59 | Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate complete all as specified & directed. |
| 60 | S&F 15 watt LED bulb 2 pin B22 base,100 Lumems per watt,PF≥0.9, voltage surge protection 4kV ,6500K/3000K cool white,operating voltage 100-240V complete all specified and directed. |
| 61 | Supply and fixingwall mounted LED tube light fitting 20 watt with polycarbonate housing with all accessories and fixing material complete all as specified and directed. |
| 62 | Supply and fixing 35W LED building security lightenergy saving & environmental friendly long life luminaire with high power LEDs as light source and electronic driver including all material required for fitting all as specified and directed by Engr-in-Charge. |
| 63 | Supply & fixing of ceiling rose, 2 phase/PVC/polycarbonate isolated body complete all as specified & directed by Engineer -in- Charge. |
| 64 | Material and labour for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated FR-LSH, unsheathed, copper conductor cable with and including continuous earth wire of size 06 Sqmm nominal cross sectional area, single core, PVC insulated FR-LSH, unsheathed,copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing incl taking down old u/s submain wiring complete all as specified & directed. |
| 65 | Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces incl taking down old u/s DB\"s complete all as directed by Engineer - in -charge. |
| 66 | Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt provison forfixing of 1 No MCCB of XT1160 frame suitableupto 125 Amp and 12 Nos MCB\"S inside of DB,with metal door and flush to wall including grouting and cutting in existingwall and making good disturbed surfacewith two coats of white / colour washing / distempering etc to match the existing one and taking down the old distribution boardalong with mcb,mccbcomplete all as directed by Engineer - in - Charge.Note:- MCB\"s,MCCB will be measured and paid separately as required. |
| 67 | Supply and fixing MCB, SP, AC, 240 volts \"C\" series capacity of 06 to 32Amps, 10kA and making connections complete all as specified & directed. |
| 68 | S&FMCB SPN 40 A, AC, 240V, 10KA, ISI Marked \"C\" curve incl thimble etc complete all as specified and directed. |
| 69 | Supply and fix MCCB 100A, 4P 415V fixed type 16KA breaking capacity complete all as specified & directed. |
| 70 | Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completioncomplete all as specified and directed. |
| 71 | S&F BLDC ceiling fan 1200mm sweep with remote, 220CMM air delivery,BEE 5 star energy ratedminimum service value≥6,copper winded motor ,anti rust powder coated aluminium blade,double ball bearing, dynamically balanced including canopy,down rod,shackel assembly,safety pin,nut bolt etc electrical connection withflexible Cu conductor cable of appropriate size from ceiling rose/junction box to the fixture complete incl writing MES No. complete all as specified and directed by the engineer-in-charge. |
| 72 | Taking down existing ceiling fan of any size, CeiIing cable end,dismentalling blades ,makeone set ofthree blades and keep them safe to deposited to E/M yard complete all as specified & directed. |
| 73 | supply ,laying commissioning ,testing of XLPE under ground LT cable 1100 volts grade of size 35 sqmm 3.5 core armoured PVC sheathed with aluminium conductor heavy duty laid in trench ,fixing on wall ,under road crossing through proctection pipe etc including taking down old LT UG cable complete all as specified and directed. |
| 74 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out including foming of bottom surface for laying of cable / pipe etc in soft/loose soil complete all as specified & directed. |
| 75 | Returning filling in including spreading levelling, watering and well ramming in layers not exceeding25 cm complete all as specified & directed. |
| 76 | Removing surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exc 1.5M above the starting point complete all as specified & directed. |
| 77 | M&L for sand cushioning, spreading & levelling, watering and well ramming in layers 8 cm before laying the cable and 15 cm after laying the cable. The sand cushioning shall be punned and after punning the thickness of sand cushioning shall be 18 cm complete all as specified & directed. Note :- The tenderer should note only punned thickness shall be measured for payment purpose only. |
| 78 | Supplying & laying burnt clay fly ash old size bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over under ground cable for protection complete all as specified and directed. |
| 79 | GI light grade tubing 40mm dia laid in trenches, road crossing , pasing through pipe or laid in wall/pole complete all as specified & directed. |