| 1 | Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, 3 nos. blades, 30 cm long down rod, copper winding, Power Factor not less than 0.9, 350 RPM,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 2 | Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor complete as required. |
| 3 | Supply of 20 W LED light batten fitting having Polycarbonate body, IP20, inbuilt convertor, accessories etc and suitable for use on 230 volts, 50 Hz, single phase,A.C. supply as required |
| 4 | Installation, Testing & Commissioning of 20 W LED light fitting complete as required. |
| 5 | Supplyof single phase, 300mm dia. 900 RPM sweep Heavy Exhaust fan with Louver and shutter/safety Guard from foreign objects, etc. complete as required suitable for use on 230 volts, 50 Hz, single phase,A.C. supply. |
| 6 | Installation, Testing & Commissioning of single phase, 300mm dia. 900 RPM sweep Heavy Exhaust fan complete as required. |
| 7 | Supply of 9 W LED bulb, suitable for 230 V, 50 Hz Single phase supply complete as required. |
| 8 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm) |
| 9 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm) |
| 10 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm) |
| 11 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm) |
| 12 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 13 | Supplying and fixing suitable size GI Modular box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 14 | Supply of 9 W LED Inverter/ rechargeable bulb With Auto-Charge Technology having Emergency time backupof not less than 4 Hours at min. of 50%illumination, suitable for 230 V, 50 Hz Single phase supply complete as required. |
| 15 | Installation, Testing & Commissioning of 9 W LED Bulb and 9 W LED Inverter/ rechargeable bulbcomplete as required. |
| 16 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 17 | Supply of minimum 35W LED type Street Light Luminaire with control gear, made of pressure die cast aluminium housing with heat resistant toughened flat glass/polycarbonate cover and minimum IP 65 protection, suitable for operation in 140-270 V, 50 HZ ACetc. complete as required. |
| 18 | Installation, Testing & Commissioning of minimum 35W LED type Street Light Luminaire complete as required. |
| 19 | Wiring for light/ power plug with 2X4sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class MS conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 20 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 21 | Supplying and fixing of nominal 2.00mm +/- 10% thick, 1000mm wide anti-skid Antistatic Electric Insulation mats confirming to IS 15652:2006 with up to date amendments and CPRI/ERDA tested suitable for 3.3 kV installation along adhesive sealing material and similar type of taping on sealing at joints and corners as per recommendations etc. as required. |
| 22 | Supply of following sizes of XLPE insulated and PVC sheathed XLPE aluminnum conductor armoured cable of 1.1KV grade conforming to IS 7098 (Part-I) with up to date amendments as required. 3.5 x 35 Sq.mm |
| 23 | Laying of one number additional PVC insulated and PVC sheathed/XLPE power Cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Laying ofcable upto 35 Sqmm. |
| 24 | Supplying and fixing following ways surfac/recess mounting, vertical type, 415 volts, TPN MCB distrubution board of sheet steel, dust protected, duly power painted, inclusive of 200 As tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (but without MCB\"s and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 Phase outlets are required.). 12 Way DB box |
| 25 | Supplying and fixing following way, horizontal type three phase and neutal, sheet steel, MCB distributing board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator). 6 Way DB box |
| 26 | Supplying and fixing 5A to 32 Amps rating,240/415 volts, 10kA,SP \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. As required |
| 27 | Supplying and fixing 63 Amp Four Pole (FP) rating,240/415 volts, 10kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. As required |
| 28 | Supply and fixing of 63 Amp, FP RCCB, 30mA RCCB (In accordance with IS 12640-1 & IEC 61008-1) 240/415, 50Hz with 6kA short circuit withstand capacity. |
| 29 | Supply of stepped type Fan Regulator Suitable to operate on 120/280 V, 50 Hz single phase AC supply |
| 30 | Supply of Wall mounted Fan of 400 mm sweep, swing type suitable for working on 240 V AC etc as required. |
| 31 | Installation, testing and commissioning of Wall mounted Fan etc. complete as required. |
| 32 | Supply of Pedastral Fan of 400 mm sweep, swing type suitable for working on 240 V AC etc as required. |
| 33 | Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 34 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt ) as required. |
| 35 | Supplying and laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 36 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. |
| 37 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 38 | Supplying, installation, testing & commissioningof Microprocessor based 8 Zone conventional fire alarm panel. |
| 39 | Supplying, installation, testing & commissioning of photo electric type smoke detector complete with all connections etc. as required. |
| 40 | Supplying, installation, testing & commissioning of flasher type sounder/Hooter unit complete with all connections etc. as required. |
| 41 | Supplying, installation, testing & commissioning of manual call point as required. |
| 42 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation,Steel wire armouring & FRLS outer sheath complete as required. |
| 43 | Supplying, installation, testing & commissioning of Auto dialer unit complete with all connections etc. as required. |
| 44 | SITC of4.5 kg carbon dioxide (CO2) type fire extinguishers confirming to IS 2878 : 1976 (with up to date amendments ) and cylinders fully chargedincluding providing suitable M.S. Stand complete as required. |
| 45 | Supply of monoblock 5HP pump 3 phase 415 Volt , single stage head range 6 to 15 mtr, 32.8 to 12.5 liter per second impellers, body delivery made of cast iron complete as required. |
| 46 | Installation, testing & commissioning of monoblock 5HP pump including Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump,boltsas per OEM reccomendation complete as required. |
| 47 | Supply of 3 phase 5 HP DOL motor starter having current range 9-14 Amp,415 V,50 Hz suitable for 5 HP monoblock pump complete with all accessories as required. |
| 48 | Supplyof 3 phase 5 HP Submersible pump complete with all accessories as required. |
| 49 | Installation, testing & commissioning of3 phase up to 5 HP Submersible pump in existing borewell including lowering, installation of wire rope of suitable size,installation and lowering of 50 mmContinuous Coil HDPE Pipe suitable for Submersible Pump outlet and installation and lowering of 3CX4 Sqmm PVC flat Copper cable for Submersible pump complete with suitable clampes, nut bolts with all accessories complete as required. |
| 50 | Supply of 3 phase 5 HP DOLstarter having current range 9-14 Amp, 415 V,50 Hz suitable for 5 HPSubmersible pump complete with all accessories as required. |
| 51 | Supply of 3 phase 3 HP openwell submersible ( Dewatering) pump complete with all accessories as required. |
| 52 | Supply of starter for 3 HP DOLstarter having current range 4-6.5 Amps,415 V,50 Hz suitable for 3 HP Dwatering pump complete with all accessories as required. |
| 53 | Installation, testing & commissioning of 3 phase 3HP-5 HP DOLstarter having current range suitable for 5 HPSubmersible pump complete with all accessories as required. |
| 54 | Supply of 6 mm Dia Wire rope duly covered/insulated with PVC for lowering of submersible pump etc. complete as required. |
| 55 | Supply of 50mm Continuous Coil HDPE Pipe for water delivery side of Submersible pump installed in borewell etc. complete as required. |
| 56 | Supply of 3CX4 Sqmm PVC flat Copper cable for Submersible pump installed in borewell etc. complete as required. |
| 57 | Supply of LED search Dragon Light of minimum 15 W of chargeable type from 240 V AC etc as required. |
| 58 | Supplying, Installation, testing and commissioning of 100 Ltr. solar water heating system with heat exchanger type including electrical heater backup, make up water tank but without piping. |