}

Tender For Special Repair To Bldg No T 117 At Mil Stn Gaya, gaya-Bihar

Military Engineer Services has published Tender For Special Repair To Bldg No T 117 At Mil Stn Gaya. Submission Date for this Tender is 07-10-2025. Building Work Tenders in gaya Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

51269590
Tender For Special Repair To Bldg No T 117 At Mil Stn Gaya
Tender
Indian
Bihar
Gaya
07-10-2025

Tender Details

Tender For Special Repair To Bldg No T 117 At Mil Stn Gaya; 1 Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc.Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed 2 Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch/Busbar including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. 3 Taking down ceiling fan/exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to MES store yard of AGE E/M complete all as specified and as directed. 4 M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including concealed PVC conduit of size 20/25mm ISI marked inclusive oftees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick hylum sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5Sq mm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincluding cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed 5 (a) One light/fan point controlled by one, one way switch 5 Amps complete all as specified and directed 6 (b) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.complete all as specified and directed 7 (c)One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.complete all as specified and directed 8 Description all as per item No. 1 here in before but 3/5 pin socket outlet point 15 amps independant, with cables of size 2.5 sqmm, PVC insulated unsheathed FRLS copper conductor cable and 1.5 sqmm PVC insulated unsheathed FRLS copper conductor cable as earth continuity conductor connected to common earth dolly all in separate PVC concuit medium grade not lesss than 20mm dia ISI marked incl provn of GI sunken box thickness not less than 1.12 mm & 3 mm thick laminated hylem sheet top cover of required size all as specified and directed. 9 S & F modular switch piano flushtype, single pole, one way, and 5/6 Amp single module complete all as specified and directed. 10 S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. 11 S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed 12 S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed 13 S & F for Ceiling rose, surface Bakelite with 3 terminals, ISImarked for batten fitting complete all as specified and directed 14 S & F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. 15 S & Fmodular white cover plate with frame 3 module 16 S & Fmodular white cover plate with frame 6/8 module 17 S & Fmodular metal flush box for 3 module 18 S & Fmodular metal flush box for 6/8 module 19 S & F for sheet metal enclosure MCBDBTPN4 way Vertical type with 200 Amps suitable for MCCB 125 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 20 Supply and fix 4 Pole MCCB 100 to 125 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and as directed. 21 S&F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 22 S&F MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and directed. 23 S&F MCB Single pole rated capacity 6 to 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and directed. 24 Supply and fix Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings 25 S & F LED bulb10 Watt 230 V AC. 26 Re-fixing of ceiling fans complete with blades, down rods, electronic regulator and accessories complete all as specified and as directed. 27 Re-fixing of exhaustfans complete with blades, and all accessories complete all as specified and as directed. 28 S & F in replacement LED lights fitting 1x 20W 220V, AC tube light 4 feet polycarbonate body including of diffuser connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories internally pre wired and necessary mounting arrangements,complete all as specified and as directed. 29 M & L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit 30 M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. Note:- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 31 Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm x 3.5 Core passing through DWC HDPE / in trench including necessary connection with lugs and cable gland etc complete all as specified and directed. 32 Galvanised iron steel tubes, ISI marked light grade of size 40mm bore for cable protection along the poles under road under drains complete all as specified. 33 Excavation in trenches n.exc 1.5 mtr wide and 1.5 mtr in depth in hard/dense soil for taking up/ laying of cable and getting out complete all as specified and directed. 34 Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. 35 Removing surplus soil to a distance n.exc 50 mtr and making good the disturbed surfaces complete all as specified and directed. 36 Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. 37 Supply and laying for brick of common burnt clay, sub class B old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. 38 Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. 39 M & L brickwork with subclass B bricks, straight or curved on plan to any radius inhalf brick thick walls built in CM (1:4) complete all as specified and directed. 40 M & Lbrick work with sub class B bricks straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) complete all as spd and directed. 41 S & F of Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as spd and directed. 42 Dismantling timber scantlings 40 sq. cm and over in section, in anyposition complete all as spd and directed. 43 M&L second class hard wood in scantling fixed in truss/purlin and rafter all as spfd and directed. 44 M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240. complete all as spd and directed. 45 Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roofcoverings all as specified. 46 S & F of Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as spd and directed. 47 S & F pre-painted galvalume aluminum zinc coating (AZ 150)GI based plain steelsheet 0.5mm thick of any coloure in ridge having tensile strength of 550 Mpafixed with self tapping screws as spd and directed 48 M&L two coat of syntetic enamel paint overnewsteel surface of any description over 10cm in width or grithnot otherwise describedover one coat red oxide primerincluding preparation of surfaces complete complete all as spd and directed. 49 Taking down cement plaster any description on brick or stone walls etc including Removing of tree/plant girth not exc 15 cm from wall/roofing including removing all roots ,raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. 50 M&L for rendering 10mm thick internal surfaces on other than fair faces of brick work in cm (1:6) complete all as spd and directed. 51 M & L rendering 15mm thick on brick wall or concrete s.urface in cement mortar (1:4) finished even and smooth without using extra cement including WPC as per manufacturer instruction complete all as specified and directed. (WPC will be measured seperately) complete all as spd and directed. 52 M&L for 1 mmthick Birlawhite putty/JK white wall care putty on walls/Ceiling surfaces complete all as spd and directed. 53 M&L for applying two coat of acrylic distemper over a coat of primer incl preparation ofold/new plastered wall surfaces complete all as spd and directed. 54 M & L preparation of old/new plastered or unplastered surfaces and applying two coat of cement base paint on walls complete all as specified and directed. 55 Taking down chowkat or frame with shutter (without taking off shutters from the frames) area not exceeding 1.5 Sq mtr each complete all as spd and directed. 56 Taking down chowket or frame with shutter (without taking off shutters from the frames) areaexceeding 1.5 Sq mtr but not exceeding 4 Sq mtr each complete all as specified and directed. 57 S & F Powder coated aluminium frame/shutters for windows, ventilators sliding/openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws,etc complete all as specified.Note : (i) Glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item.(ii) Item shall be paid as per weight of aluminium section (iii)The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight (iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing.complete all as spd and directed. 58 M & L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded aggregate as in plinth protection and similar work finishing surfaces even and smooth without using extra cement. 59 Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as spd and directed. 60 M & L for anodised aluminium snap grid frame work for false ceiling all completed all as specified and as directed. 61 S & F of 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system duly suspended with 2 mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof complete all as specified directed. 62 S & F Solid PVC Door frame size 50mmx 47mm made out of 5mm single side prelam PVC sheet & edges will be painted to match with prelam sheet reinforced with M.S. Square tube and fixing in opening as per spc & drawing completed all as specified and as directed. 63 S&F factory made solid panel PVC door shutter 30mm (Style) consisting of frame made out of M.S tubes for top and bottom rails M.S frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specifiaction & drawing. 64 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises 65 M & L coloured digital Glazed ceramic coloured tiles in vertical surfaces 450 x 300 x 7-8 mmset and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM (1:4) completed. 66 M & L coloured Non Skid ceramic coloured tiles (square/rectangular) area of each tile exc 0.11 Sqm but not exc. 0.18 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer with CM (1:4) complete 67 M & L for vitrified ceramic tiles double charge light shed of 7.5 mm thick (square/ rectangular) polished, area of each tiles n.exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick in cement mortar (1:4) complete. 68 M&L for granite (any type) work (table rubbed and polished) 18 to 20 mm thick in working platform and like including cutting for sink etc. in cement mortar (1:4) including rounding of edges and pointing in white cement (1:2) using marble dust with admixture of pigment to match.complete all as specified and as directed 69 S&F in repair 15 mm dia stop valves/angle valves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as spd and directed. 70 S&F PVC connections 15mm size with PTMT nuts of length 450 mm all as specified and as directed. complete all as spd and directed. 71 S & F of 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as spd and directed. 72 S&F CP health faucet 15 mm with flexible tube of stainless steel provided rubber hose and wall hook etccomplete as in repair all as specified.complete all as spd and directed. 73 S& F PVC ( SWR ) nahani ntrap / floor trap 75 mm dia all as specified and as directed. Make - Reliance, finolex, supreme, kisan, prince complete all as spd and directed. 74 S&Fvitreous china wash basin white flat back size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopperincluding brackets or fixed to walls with anchor fastnersall as specified and directed 75 S & F of 10 litre PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets 76 S & F as in repair of whiteseat cover for pedestal pattern water closet including fixing bolts complete. 77 S & F Supplying and laying of CPVC pipes 20 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed 78 M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc complete all as specified and directed. 79 M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc complete all as specified and directed 80 S&F PVC (SWR) bends ISI marked any radius of 110 mm borewithaccess door complete all as specified and directed. 81 S&F PVC (SWR) bends ISI marked any radius of 75 mm borewithaccess door complete all as specified and directed. 82 S&F PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe complete all as specified and directed 83 S&F PVC (SWR) vent cowl for 110 mm bore pipe complete all as spd and directed. 84 Supplying and laying of CPVC pipes 25 mm outer dia SDR 11 including fittings on walls laying in floors incl chase cutting complete all as specified 85 S&F in repair rotational moulded three layer polyethylene water storage tanks (cylindrical vertical with closed top) capacity 1000 Ltrhoisted and fixed in position all as specified and directed 86 S&F in repair 15 mm dia two way bib taps, cast copper alloy,fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions 87 S&F sinks with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm including waste pipe and coupling complete all as specified and directed. 88 M & L for 18 mm thick Pre-laminated particle board, interior grade, pre-laminated one side with decorative choice lamination and other side balancing white lamination and fixed with screws to timber framework with teak wood beading as in linings, panelling wsimilar location complete all as specified and directed. 89 S & F of 30 mm wide flap when open, mild steel bright finish or electro galvanised continuous (Piano) hingecomplete all as specified and directed. 90 S&F magnets to be used in cabinets as specified and directed 91 S & F of stainless steel fancy type handle 150 mm long complete. 92 Supply & Fixing heavy duty telescopic sliding channel suitable for 18/19 mm thick prelaminated paarticle board/ply board fixed at site as per directed. 93 S & F Male Brass Threaded Adaptor (MTA/ MBTA/Female Brass Threaded adaptor (FTA/ FBTA)20 mm dia complete all as specified. 94 S&F CP Wall mixer (three in one) 15mm bore for bathroom all as specified and directed 95 Supply & fix in repair brass chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed 96 S & F in Repair of Vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, but excuding flushing cistern and flush pipe complete. 97 S&F in repair Mortice lock, vertical type, size 100 mm 2 levers aluminium type complete. 98 M&L 25 mm thick cement concrete type B-0 (1:2:4) using 12.5 mm graded stone aggregate as in levelling coarse of floor complete. 99 S&F aluminium handles, cast type, anodised of size 150mm. complete all as spd and directed. 100 S& F 100mm butt hinges, extruded aluminium with galvanised MS hinge pin anodised type C - 21 complete all as spd and directed. 101 S&F in repair 24-25mm bore cut to length as required stainless steel draphery rods as required of colour as selected & directed 102 S&F in repair 24-25mm bore stainless steel decorative brackets as required of colour as selected & directed 103 S & F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanised wire staples (to be fixed upto four storey of bldgs) complete. complete all as spd and directed. 104 S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in a square n exc 0.5 Sq m in each pane(to be fixed upto four storey of bldgs) complete all as spd and directed. 105 S&F 4mm thick figured glass, pin head type and glazing with oil putty in a square n exc 0.5 Sq m in each pane(to be fixed upto four storey of bldgs) complete all as spd and directed. 106 S&F as in repair 150mm long aluminium anodised barrel tower bolt complete. complete all as spd and directed. 107 Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 24.26 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail