| 1 | Excavation in trenches n.exc 1.5m wide and nexc 1.5m in depth as in foundation etc as in any type of soil complete all as specified and directed. |
| 2 | M&L PCC Type D2 (1:4:8) using 40mm graded stone agg as in foundation filling mass concrete complete all as specified and directed. |
| 3 | Returning filling in including spreading levelling watering and well ramming in layers nexc 25cm as in soil complete all as specified and directed. |
| 4 | Removing excavated material nexc 50m and depositing where directed at a level nexc 1.5m above the starting point with soil complete all as specified and directed. |
| 5 | M&L RCC M-25 design mix (20 mm graded stone aggregate) as in foundation , raft, footing, plinth beam, base for column etccomplete all as specified and directed. |
| 6 | M&L RCC M-25design mix(20 mm graded stone aggregate) as in column complete all as specified and directed. |
| 7 | M&L RCC M-25 design mix (20 mm graded stone aggregate) as in roof beams, chajja lintle etc. complete all as specified and directed. |
| 8 | M&L RCC M-25design mix (20 mm graded stone aggregate) as in slabs suppoorted on walls,beams and column in floors, roof, landings, balconies, canopies, deck slab and in shevels for almirahthe like similar work etc complete all as specified and directed. |
| 9 | M&L Formwork to side of concrete foundation footing base of column raft beam and plinth beam with required gap filler etc complete all as specified and directed. |
| 10 | M & L form work to side/bottom of pillars , post , column, beam, slab square , rectangular or polygonalrequired gap filler etc complete all as specified and directed. |
| 11 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders,bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, in fair finishedetc. complete all as specified and directed. |
| 12 | M& L form work to sofits of suspended slabs such as roof slabs,floors slabs,landings/chajjaand similar work not exceeding 200mm thick (horizontal or sloping) for fair finished surfaces of concreterequired gap filler complete all as specified and directed.. |
| 13 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, oncrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar workfor fair and smooth surface exc 10cm but n exc 20cm wide completeall as specified and directed. |
| 14 | S&F mild steel bars 10 mm dia and over (TMT) cut to length bent to shape required including cracking,bending spirally for hooping ends and binding with and including mild steel wire not less than 0.90 mm dia quality of steel conforming to Fe-410-0 or Fe-410-S complete all as specified and directed. |
| 15 | S&F mild steel bars 5 mm dia and over up to 10 mm dia in stirrups space and binders.(TMT) cut to length bent to shape required including cracking,bending spirally for hooping ends and binding with and including mild steel wire not less than 0.90 mm dia quality of steel complete all as specified and directed.. |
| 16 | M&L hardcore of gauge exc.63 mm but not exc 100 mm deposited , spread and levelled in layers n exc. 15 CM thick, watered and rolled/rammed to a true surfacecomplete all as specified and directed. |
| 17 | M&L Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 18 | M &Lfor 10 to 12mm smart care ready mixrepair plaster is a specially designed ready to use cement based plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacture instructions) over interior wall surfaces complete all as specified and directed.(coverage area 24-28 kg/sqm . |
| 19 | M &Lfor 10 to 12mm smart care ready mixrepair plaster is a specially designed ready to use cement based plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacture instructions) over exterior wall surfaces complete all as specified and directed. ( coverage area 24-28 kg/sqm). |
| 20 | M &Lfor 5mm smart care ready mixrepair plaster is a specially designed ready to use cement based plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacture instructions) overceiling surfaces complete all as specified and directed. |
| 21 | M&L two coat of synthetic enamel paint over new prepared steel surface but overred oxide primer complete all as specified and directed. |
| 22 | M&L for Machine cut kota stone slab flooring 20-25mm thick incl and over cement screed bed 20 mm thick in 1:6 cement and sand mortrar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing andmirror polishing complete all as specified and directed. |
| 23 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over and incl 10 mm thickcement screed bed 1:4 cement and sand mortrar complete all as specified and directed. |
| 24 | M&L for 75mm thick cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base of floor etc complete all as specified and directed. |
| 25 | PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection( 75 mm thick ) laying in alternate ways finished even and smooth without using extra cement plinth protection shall be laidto alternate bay system each bay shall exceed 3m in lentgth12mm wide and 75mm deep joint sall be filed with hot blownbitumen 85/25and sandcomplete all as specified and directed. |
| 26 | M & L two coats of cement base paint over coat of primer including preparation new plastered surface of wall complete all as specified and directed. |
| 27 | M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed. |
| 28 | M&L Three coat of white wash over newly plasterdsurface on ceiling surfacess including preparation complete all as specified and directed. |
| 29 | Material and labour for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in roof kerbs, paddings, mud stops slightly chamfered or rounded in edges including required grove cutting and including water proofing compound@ 0.2 ltr per 50 kg bag of cement complete all as specified and directed.Note : WPC shall be measured and paid seperately. |
| 30 | M&L for preparation of surface apply one coat ofCipoxy 16D primer in the ratio 1:1 spreading at the rate of 0.200 kg-0.250 kg /sqm in complete dry condition where moisture contain below 7% (should be checked with moisture meter)Allow the primer coat to dry for 6 to 8 hours. Apply 1st coat ofRoofseal Classic without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. Lay a 45 GSM Fibre glass mesh as a reinforcing material which is incorporated in the coating when the first coat is still in wet condition. Allow the first coat to dry for approximately 4 to 6 hours. Apply the second of chemical with the same application coverage, but in a direction perpendicular to that of the first and second coats. Allow each coat to air cure for a minimum of 4-6 hours after application. Check to see no void surface is left untreated / uncoated.Allow the system to air cure for 7 days minimum etc complete all as specified & directed. |
| 31 | S&F ofwindowsmade of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy-duty stain less steel pivot hinges shall be provided per shutter. The windows should be panelled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self-expanding, screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished item of work including of all taxes etc complete specified and directed. |
| 32 | Supply and fixing ofventilator made of pre-painted steel (Base steel as per IS 513 of 0.58 mm thick “D” Quality galvanized as per IS 277 with Zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 48x50mm, centre mullion should be of 48x50mm, section for shutter should be of 52x 25mm and rebate for Glazed shutter with a 20mm provision for Guard bars/Grills. The sections are to be cut to length metre joined with corner bracket. Centre mullion is to be fixed with mullion cap. Handle, stay, 2 nos. of Stainless Steel heavy duty Pivot hinges shall be provided per shutter the windows fitted with 4mm thick plain float glass with rubber gaskets including fixing the frames in concrete/masonry wall by means of self expanding screws, Including fixed panel beading section should be of 12x12mm. Outer frame and mullions to have 10mm Square guard bars with 6” (152.4mm) pitch etc complete all as specified and directed. |
| 33 | M & L Mild steel farmed work as in doors (as in ckowkats/shutter frame) or gates of angle or other section with guest plates rail, brasses rail etc exculsive of steel sheeting or other covering hanging also fastening and fixing complete confirming to GdeFe-410-W(Gde-E-250)quality-B including shop coat of red oxide including prepration of surface before fixing complete all as specified and directed. |
| 34 | Material and labour for PCC(1:3:6) type C1 (using 20mm graded stone aggregate) for fixing hold fast/in chowkhat complete all as specified and as directed. |
| 35 | S & F 35 mm thick flush shutters, boardsolid core construction, with block board core and plywood face panels, commercial side on both side ete complete all as specified and directed. |
| 36 | S&F 100 mm longStainless steel Butt hinges complete all as specified and directed. |
| 37 | S&F 200 mm longStainless steel, barrel tower bolts of extruded section complete all as specified and directed. |
| 38 | S&F 150 mm longStainless steel handles, fabricated type, anodised complete all as specified and directed. |
| 39 | S&F 250 mm longStainless steel, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 40 | M&L for applying two coats of synthetic enamel paint over a coat of pink primer wooden surface over 10 cm width or girth including preparation of new or previously untreated wood surfaces complete all as specified and directed |
| 41 | Supply only integral water proofing compound liquid admixture for mortar complete all as specified and directed. |
| 42 | Surface excavation in soft/loose soil not exc 30 cm deep and average 15cm deep and getting out complete all as specified and directed. |
| 43 | M & L hard core of broken stone or boulder having gauge n exc 63mm, deposited, spread and levelled in layers n exc 15 cm thickwatered and rammed to a true surface, complete all as specified and as directed. |
| 44 | M&L for 75 mm thick Cement concrete type D-2 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing finishing surface even and rough using broomfinish complete all as specified and directed. |
| 45 | M&L for Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand,compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified & directed. |
| 46 | M&L for PCC 1:2:4 Type B1 ( using 20 mm graded stone aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in eight, copings, kneelers, apex stones bed plates, kerbs chajjas , water troughs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating, fixing of chain link fencing etcall as directed including necessary formwork etc complete all as specified and directed. |
| 47 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over andincluding priming coat of exterior primer applied @ 0.90 litre/ 10 sqm overweather proof 2 mm thick putty on new concrete surface including preparation etc complete all as specified and directed |
| 48 | M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts.grade FRLS PVC insulated unsheathed cable with proper colour codingdrawn in stove enamelled steel conduit with all accessoriesandFRLS PVC insulated 1.5 Sqmm multi standard unsheathed copper wire for continues earth, sunk in cast iron/Pressed steel terminal boxes 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint out side, including 3 mm thick plastic laminatedsheet for mounting switches, sockets, fan regulators etcconnecting earthand making good to the disturbed surfaceof wall/floor and matching with existing specifications.Connections of cable with MCB\"s or bus bar shall be done through proper size copper/brassthimbles complete all as specified and directed.. Note : Conduit shall be fixed on surface of roof /terrace with necessary saddles where concealing of conduitis not feasible at no extra cost for the following :-(a) One light /fan point controlled by one switch. |
| 49 | (b)One 5 pin socket outlet5 Amps on same board . |
| 50 | (c) One 5 pin socket outlet 5 Amps on independent board . |
| 51 | All as per item No 48 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent boardcomplete all as specified and directed. |
| 52 | S&F switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed. |
| 53 | S&F switch piano flush button single pole one way 15 amps 230 Voltswith polycarbonate body complete all as specified and directed. |
| 54 | S&F socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body complete all as specified and directed. |
| 55 | S&F socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed. |
| 56 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed. |
| 57 | S&F ceiling rose, PVC/polycarbonate, insulated body surface bakelite 65mm dia three terminals complete all as specified and directed. |
| 58 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 59 | S&F exhaust fan steel bodyAC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 60 | Supply and fixing LED light fittingwith high out put diffuser 4 feet, 20 watt 220 V AC, LUMEN < 2000 with lumen efficacy 120 lumen/watt, basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 61 | Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 62 | Supply and fixing LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection,fixed to pole or wall of building with and including suitableBracket made out of25 mm dia GIlightgrade pipe, 1.00 m long bent to shape by cutting & weldingas required & directed and fixed withtwo Nos of FI clamps 35x6 mm to be tightened with suitable size of bolts, nut and washers and including painted withtwo coat of aluminium paint over a coat of red oxide primer, and including connecting the fittingto electric sourcewith & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduitincluding all accessories and fixing arrangements for fixing the light fitting and writing the date of fixing on security light with permt marker complete all as specified and directed. |
| 63 | S&F sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-54 protection double door complete with appropriate size bus bar and neutral link incl cutting/chasing of wall and make in good to the disturbed surface complete all as specified and as directed. |
| 64 | S&F sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-54 protection double door complete with appropriate size bus bar and neutral link incl cutting/chasing of wall and make in good to the disturbed surface complete all as specified and as directed. |
| 65 | Supply and fixing MCB SP 5 to 32 Amp rating 240V, 10KA \"C\" curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 66 | Supply and fixing MCB SPN 40 to 63 Amp rating 240V, 10KA \"C\" curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 67 | M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and rivetedto earth plate by means of nuts, bolts, check nuts & washers, of galvanizediron or steelwith connected to test point and testing on completion including 15mm GI light grade pipe for earth leadprotection from earth point to earth plate, including provnadequate quantity of charcoal dust mixed with35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth platewith 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire meshwith and includingall necessary excavation& earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. . |
| 68 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 25sq mm 4 core complete all as specified and directed. |
| 69 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 10sq mm 2 core complete all as specified and directed. |
| 70 | Excavation in trenches in soft/loose soil N. exc 1.5 Mtr wide and not exc. 1.5 Meter deep and getting out including forming bottom surface for laying of cable complete all as specified and directed. |
| 71 | Returning filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 72 | Removing surplus soil to a distance n.exc 50 Mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. |
| 73 | M&L for drilling suitable dia horizontal bore holes below/under existing road surfaces / floors at a level not less than 0.60 mtr etc with using mechanical/ or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed. |
| 74 | S & F of double wall corrugated pipe 75/63 mm dia with all fitting laid in bore holes/trenches/drain or fixed along with pole/wall includingFI clamps, nut, bolts etc. complete all as specified and directed. |
| 75 | Supply and fixing of 200 amps outdoor type conical shape, 4 way, 415 volts busbar chamber, 4 pole, 50 Hz, 415 volts, on wall /pole/panel with proper lugs having 4 Nos of copper bus bars fixed on wall /floor on angle iron leg of size 45 mm x 45mm x 5 mm of length 500 mm including grouting and cable connection complete all as specified and directed. |
| 76 | Supply and fixing MCCB 4 pole, 160 Amps, 50 Hz, Icu=35 KA at 415 volts with thermal magneticalongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity standard complete all as specified anddirected. |