| 1 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out jointsandpreparingandplasteringthesurfaceofthewallscomplete includingdisposalofrubbishtothedumpinggroundwithin50mlead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) B-13.1 |
| 2 | Distempering with oil bound washable distemper of approved brand and manufacturetogiveanevenshadeincludingallscaffolding.(A)Old work(oneormorecoats)includingscrappingsurfaceandnecessaryrepairs.Same Colour. (P-128/12.37.2(b) |
| 3 | Paintingexteriorsurfaceof Wall with100%acrylicexteriorpaintof approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etccomplete in all respect. Old Work.(P-130/12.43.2) |
| 4 | Painting with synthetic enamel paint of approved brand and manufacturetogive an even shade Old work (One or more coats). (P-130/12.46.2) |
| 5 | Labourchargesforrepairtodoor/window withoutusing any material such as applying randha (finishing) tightening of bolts & screw etc.(P-136/13.24)) |
| 6 | Renewing glasspanes,withputty andnailswherevernecessary:Floatglass panes of thickness 4 mm.(P-134/13.4.1) |
| 7 | Providing and fixing external grade board solid core single leaf flush door shuttersISI2202-67markedusingPhenolformaldehyderesin inglue both sides with approved steel fittings complete as per annexure \"A\"30mm thick Commercial Veneer both side. (P-86/8.13.2.1) |
| 8 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete.40 mmthickwith20 mmthicknominalsizeaggregate.(P-114/11.3.1) |
| 9 | Providingandfixing1stqualitystandardwhite,grey,ivory,fumered brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade ofthetilecomplete(excluding thecostofcementplasteronwallsandpillar).(P-80/7.12) |
| 10 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mmconfirming toIS:13755andIS:15622coloursuchas white, grey, ivory, fume red brown, light green, light blue and other light shadesinfloors,steps,pillarsetc.laidonabedofneatcementslurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortarbed 1:4). (P-80/7.13) |
| 11 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design(B-101/10.22) |
| 12 | P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (IS : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make, 25 mm G.I. waste pipe complete including cutting & making good the wall. Size 550mm x 400 mm. (P-179/1.36.3) |
| 13 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm. (P-175/1.2.2) |
| 14 | P & F European type white glazed vitreous china 1st quality W.C pan (IS: 2556 Mark) with P or S trap including cutting and making good the wall and floor(P-175/1.3) |
| 15 | P&Flowlevelflushingcisternof10Ltrcap.IS2556markofappd,. Make weith complete fitting CI brackets duly painted brass ball cock with ball IS 1703 mark complete incl. Cutting and making good the wall PVCwithPVCbend as per IS:7231.(P-177/1.20.2) |
| 16 | P & F water closet Seat Covers with brass hinges complete Solid PVC (IS2548 marked) grade-I White for EWC. (P-176//1.7.2) |
| 17 | P&FJetsprayforwaterclosetwithC.P.CopperTubeflangeofapproved make. (P-183/1.59) |
| 18 | Labour charges for removing W.C. pan (any type) of all sizes with careincluding all necessary fittings P or S trap. (P-176/1.9) |
| 19 | Providingandfixing ChlorinatedPolyvinylChloride(CPVC)pipes(IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making goodthesameincludingtestingofjointscompleteasperdirectionof EngineerinCharge.(Concealedworkincludingcuttingchasesandmaking good the walls etc.,) 20 mm nominal size |
| 20 | Providingandfixing ChlorinatedPolyvinylChloride(CPVC)pipes(IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making goodthesameincludingtestingofjointscompleteasperdirectionof EngineerinCharge.(Concealedworkincludingcuttingchasesandmaking good the walls etc.,) 25 mm nominal size |
| 21 | P & F 15 mm. Dia Connection Pipe of approved quality/make : PVC pipewithC.P. Brass nuts upto length, 300 mm. (P-191/2.13.1) |
| 22 | P&FGratingofapprovedquality/make:StainlessSteelSheetsize125mm dia. (P-182/1.48.1) |
| 23 | P&FPilllarCocks(IS:8934Mark)ofsuperiorquality andapprovedmake: C.P. Pillar cock, 15 mm dia nominal bore. (P-189/2.6.1) |
| 24 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make :C. C.P. Brass Long body, 15mm nominal bore weight not less than 690 gm. (P-190/2.7.4) |
| 25 | P& FBib Cock (IS : 8931 Mark), Superior quality of approved makeC.P. Brass bib cock,15mm nominal bore. (P-190/2.7.3) |
| 26 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. (P-192/2.15.1) |
| 27 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal25mm nominal bore. (P-192/2.15.3) |
| 28 | P&FrigidPVCPipe(IS:4985mark)classII/(4Kg./Cm2.)approved quality /makeincluding joining the pipe with solvent cement rubber ringand lubricant. 110 mm dia. (P-206/3.16.3) |
| 29 | P&FPVCStorageTank ISIMarked(IS: 12701)indicating the BIS license No),of approved make with cover, 25mm dia 1M long G.I. over- flow pipe &25 Cm.long washout pipewith plug & socket,including making connection etc., complete of approved design 500 litres capacity.(P-194/2.26.3) |
| 30 | P&FInletConnection(AngleValves)Superiorquality,ofapproved make, for Wash basin, Gyser etc C.P. Inlet connection 15mm.Brass (IS :8931 marked).(P-191/2.12.1) |
| 31 | P&FBallCock(IS:1703Mark)withRod&P.V.C.BallcompleteBrass wt.not less than 300 gm,15mm.(P-191/2.11.1) |
| 32 | B-8.4.2.3Providingandfixing fully panelled/partly panelled/ doubleleafshutter framesfordoorsasperapproveddesignanddrawingswithapproved ordinary C.P./ oxidised steel fittings as per Annexure - \"A\" and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete :30 mm thick Shesham wood grade I |
| 33 | B-8.6.8Providing and fixing wood panelling or panelling and glazing in panelled orpanelledandglazedshuttersfordoors,windowsandclerestory windows(Areaofopeningforpanelinsertsexcludingportioninside groovesorrebatestobemeasured).Panellingforpanelledandglazed shutter 25 mm to 40 mm thick Wire gauge 24 gauge 14 mesh of IS 1568-1970 marked 85 gauge of dia 0.56 mm |
| 34 | B-9.19Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screwswithfixingclipsorwithboltsandnutsasrequiredincluding providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excludingthecostofmetalbeadingandotherfittingexceptnecessary hingesofpivotssteelhandlespegstayetc.asrequired:Windowsside hung /Ventilators top or centre hung (openable) |
| 35 | B-9.26Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 36 | B-9.27ProvidingandfixingSquarebarsorotherflatweldedtowindow, ventilatiors etc. |
| 37 | Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :-Choping losse and cracked concretetorequireddepth,cleaningtheexposedsurfaceofsteeland concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.Applying Epoxy primer on the exposedsteelbars.ApplyingEpoxyhardenerandresinmix(asper manufectured\"sspecification)onconcreteandsteelbarswith brush.Speadingdrycementmortar1:2mixoverepoxytreatedwet surface and allow it to dry for one day.Plastering the surface with cementsand mortar 1 : 3 upto depth of 30mm complete. |
| 38 | B-9.5Providing and fixing T-iron frames for doors, windows and ventilators of mildsteelTee-sections,jointsmitredandweldedwith15x3mmlugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugsand screwsor rawl plugsand screwsor with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 39 | B-9.17+9.17.1Providing andfixing M.S.sheet1mm thickdoubleleafdoorshutterin angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flatironaboveandbelowlockrailofsize50x5mmbeadingextra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 40 | B-7.3.2Providing and fixing stone slabs table rubbed, 15-18 mm thick in Walls, Steps,Pillars,Counters,Jambs,Shelves,Sillsetc.laidon12mm(Av.) thickbaseofCM1:3(1cement:3coarsesand)jointingwithwhite cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match theshadeofthemarbleslabincludinggrinding,rubbingandpolishing complete.Keseriaji/ Abu Ambaji (Green Marble) 1501 Cm2 to 3600 Cm2 Tiles |
| 41 | B-13.23Repairofexistingsteelglazeddoors,windowsandventilator,MSsheetdoor, gargedoors,compoundwallgatesetc.byweldingdrillingcomplete include. Cost of welding rods and hire charge of welding meachine and TP etc complete |
| 42 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : (i) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (ii) laying second layer of Fiber glass cloth when the first layer is still green .Overlaps of joints of fiber cloth should not be less than 10 cm.(iii) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proffing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. (iv) fourth and final layer of brick tiling ‘with cement mortar or any other approved protective coarse. (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured. (B-15.4) |
| 43 | E-1.5 Rewiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mmnominal size FR PVCinsulated unsheathed flexible copper conductor1.1kVgrade and1.5sq.mmnominalsizeFRPVCinsulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISImarkedMMS(IS:9537P-III)virginmaterialPVCconduit&it\"sISI marked(IS:3419-1988)accessories,roundtiles,1.2mmthickMSboxwith earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium platediron/ brass screws,cupwashers,makingconnections,testingetc.as required. For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/WiringaccessoriesreferChapterE-04,E-05&E-07For additionaltechnicalparametersofproduct/workreferAnnexure\"A\"attached with this BSR E-1.5.1 Short point (up to 3 mtr.) |
| 44 | E-1.5.2 Medium point (up to 6 mtr.) |
| 45 | E-1.5.3 Long point(up to 10 mtr..) |
| 46 | E-1.7.1 Rewiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand1.5sq.mmnominalsizeFRPVCinsulatedunsheathedflexiblecopperearth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III)virginmaterial PVCconduit&it\"s ISImarked(IS:3419-1988)accessories,1.2 mm thickMS box with earth terminal of required size,6 Aswitch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brassscrews, cup washers, making connections,testingetc.asrequired. Forspecificationofcopper Conductor, PhenolicLaminatedsheet\"s&Electrical/ WiringaccessoriesreferChapterE- 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.On board |
| 47 | E-7.36 Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification of Wiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 48 | E-7.20 Providing & Fixing of IS 11037:1984marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineerincharge. Foradditionaltechnicalparametersofproducts/work , refer Annexure \"A\" attached with this BSR . |
| 49 | E-6.1 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement)4KVimpulsewithstandvoltage,ISImarkedIS8828(1996)/ conformingtoIEC60898-12002,IEC60947-2,lowwattlosses,tripfree mechanisum , energylimiting ofclass 3 as per IEC,minimum phase terminationcapacityof35sq.mm.,conductorlineloadreversibility,IP20 contactprotectionandfittedin existingdistributionboard/sheets,minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& AllasperpreapprovedbyEngineerincharge.Foradditionaltechnical parameters of product / work refer Annexure \"A\" attached with this BSR.Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating. |
| 50 | E-6.2.1.1.Providing&Fixingof240/415Visolator ISImarkedIS:13947- III/conforming toIEC 60947-3,suitable forAC22Autilizationcategory,4KV impulsewithstandvoltage, truecontactindication, Redcolourdolly /lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protectionandfittedinexistingdistributionboard/sheet includingmaking connections,testing etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Double pole Isolator. 63 A rating. |
| 51 | Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ Glass housing SMDMidPowerLEDtuberod (withintegral driver& alumn.heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surgeprotectionof2.5KV,THD<20%,p.f.≥0.95,CRI>80,lifetimeof minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) ,maximumpowerconsumptionshouldnotmorethanthespecifiedratingand Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). ManufacturesWordMark/NameEngraved/Embossing/Screenprintingon housing.OEMmusthaveitsowninhouseNABLlabsetupforalltesting facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall besubmitted. Allasperpreapprovedby Engineerincharge. Foradditional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing. (E-17.2.2) |
| 52 | Providing&Fixingof BEE Starratedcopperwoundeddoubleballbearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rodupto80cm withsecondary support safety cable (steel rope), cotterpin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testingetc.asrequired.AllasperpreapprovedbyEngineerincharge. For additionaltechnicalparametersofproducts/work ,referAnnexure\"A\" attached with this BSR. 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ). (E-15.7.3). |
| 53 | P & F ISI marked (IS:3854) 6 amp. flush type non modular switchwith CM/L no. printedandmade outfrom industrialgrade Polycarbonateorfireresistant ABS material including cutting hole in tile and making connection testing etc. as required.AllasperpreapprovedbyEngineerincharge. Foradditional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. (E-7.1). |
| 54 | Providing & Fixing ofISI marked (IS :3854)non modular 6A bell push surface type CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material includingmaking connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . (E-7.5) |
| 55 | Providing & Fixing ofof 3/5 pin 6 amp. flush typenon modular socketmade outfromindustrialgradePolycarbonateorfireresistantABSmaterial,brass terminalwithPorcelainbasedbackcover&captivescrewsincludingcutting holeintileandmakingconnectiontestingetc.asrequired.Allasperpre |
| 56 | Providing&Fixingof ISImarked(IS:2268-1994)gongbellwithCM/Lno. printedincludingmakingconnectiontestingetc.asrequired.Allasperpre approved byEngineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . (E-7.23) |
| 57 | Providing&FixingofIK08,IP66protectedLEDStreetLightLuminaireon existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125lm/ wtandpotteddriver & has a uniqueBIS R numberwith InputVoltageAC120to270VACwithHighvoltageCutoff @>=300VACandAutoresettingSafety,Power Factor>0.95 driver Efficiency >85% ,THD(I)<10% Humidity 10%to90%RHWorkingTemp- 5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual ormore than50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. ManufacturesWordMark/NameEngraved/Embossingondiecasthousingto allowtraceability/authenticity.FixtureshallbeASPERIS10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilitiesfor LEDfixtures. (LM79/LM80)Certificate/reportwithliable warranty ofproduct/accessoriesfrom OEMshallbesubmitted.Allasperpre approved byEngineer in charge.For additional technical parameters of products/work ,referAnnexure\"A\"attachedwiththisBSR.LEDStreet Light fixture with Minimum lumen output 8700 lm (E-18.12.5) |
| 58 | Providing&FixingofRecessed/surfacemountingheavy duty horizontaltype Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thickconforming to IS-8623-1 & 3 /IEC 61439- 1 & 3, powder paintedcomplete withreversible door (for double door DB only )100 amp.insulated copper bus bar/shorting link, copper neutral link, copper earth link , color coded interconnecting wire setof suitableratinganddinbar,maskingsheet, makinginternalDB terminations with copper lugs, Ferrules,detachable gland plate, including making connections,testing etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 16 Way (16+2) (E-6.10.5) |
| 59 | Providing&FixingofRecessed/surfacemountingheavy duty horizontaltype Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thickconforming to IS-8623-1 & 3 /IEC 61439- 1 & 3, powder paintedcomplete withreversible door (for double door DB only )100 amp.insulated copper bus bar/shorting link, copper neutral link, copper earth link , color coded interconnecting wire setof suitableratinganddinbar,maskingsheet, makinginternalDB terminations with copper lugs, Ferrules,detachable gland plate, including making connections,testing etc. as required.OEM shall have submitNABL / CPRI /ERDA accrediated lab type test reports& All as per pre approved by Engineer |