| 1 | Demolition of Asbestos cement (corrugated, semi corrugated etc.) sheet in roof coverings complete all as specified and directed. |
| 2 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall clading fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and directed. |
| 3 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and directed. |
| 4 | Dismantling of wall/ ceiling boards (fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified. |
| 5 | M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mmin a grid of GI system duly suspended with 4mmdia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clipusing 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) for providing positions for light fixtures,air conditioning diffuser and ducts, sprinkler, smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall, Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid including two coats of OBD over a coat of suitable primer complete all as specified and as directed.\" |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 7 | M&L for Non Skidjoint free coloured Ceramic tiles 7 to 8 mm thick (square or rectangular), area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, laid over and including screed bed or bedding layer of mortar, 15 mm thick, in CM 1:4 complete all as specified and as directed. |
| 8 | M&L for Glazed ceramic tiles on vertical surface of size 450X 350X 7-8mm or 300x200x7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of the tiles laid over and including 10mm thick rendering as backing coatin CM 1:4 with wire markings to receive tile over it, complete all as specified and as directed. |
| 9 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. |
| 10 | M & L for brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 11 | Supply & providing water proofing treatment with polymeric standard water proofing membrane having 10 years guarantee for water tightness comprising with the following courses of treatment/specification from bottom to top:- (a) Taking out old roof treatment and roughening the concrete roof surffaces by picking, sweeping cleam and washing down with water to remove dust etc and disposal of rubbish not exceeding 100 mtr distance from starting point.(b) Brushing neat cement slurry with 3.0 kg of cement per square meter.(c) Rendering 15 mm thick in cement mortar 1:4 over RCC slab mixed with water proofing compound @ 3% by weight of cement or as per manufacturer\"s instruction. (d) Preparation of plastered surfaces and applying one coat of polymeric modified bitumen 85/25 @ 1.2 Kg/Sqm over a coat of polymeric primer @ 0.30 Kg/Sqm including cleaning surface, all asper manufacturer\"s specification.(e) Water proofing treatment with APP based polymeric membrane of thickness not less than 3mm and weight 3.6 to 4 Kg/Sqm re-inforced with non-woven polyster fabric (weighting not less than 160 gm/Sqm) by torch application method. The overlaps shall be minimum 100mm on the transverse direction and 75 mm on the longitudinal direction and cutting grooves in wall for inserting wherever required complete all as per manufacturer\"s instruction and as specified and directed.(f) M&L for preparation of new APP roof surfaces of any description and applying two coats of aluminium paint @ 0.1Litre /Sqm/Coat on APP surfaces exc.10cm width or girth all as specified and directed.Note;- (i) water proofing compound shall be measured and paid separately as supply only.(ii) Works shall be executed through the authorised applicator of the manufacturer and documents in support of the same shall be submitted to the Engr-in-Charge prior to the commencement of the work. |
| 12 | Supply only integral water proofing compound complete all as specified and directed. |
| 13 | Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and complete all as specified and as directed. |
| 14 | M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 25 mm thick finished even and fair complete all as specified and directed. |
| 15 | S & F in repair 20 mm nominal size brass ball valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed. |
| 16 | Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 17 | Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 18 | Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 19 | Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 20 | S&FIN REPAIRS,bib taps with wall flange, fancy type, quarter / half turn, chromium plated, long body with capstan head and cup, screwed down, screwed for iron pipe or for brass ferrule including accessories, suitable for bore of pipe 15 mm, complete all as specified and as directed. |
| 21 | S & F in repairs 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed. |
| 22 | S&F IN REPAIRS, vitreous china wash down water closet of\"Orissa\" pattern size 580 x 440 mm white with integral foot restsincluding removing filled lean concrete from sunken portion and putting of lean concrete after treatment of sunken slab, connection to trap, flushing cisternand to flushing pipeetc. complete and making good to floor, complete all as specified and as directed. |
| 23 | S&F IN REPAIRS Vitreous China Wash Hand Basin, size 550 X 400 mm (Flat Back or Angle Back type) including cutting for and pinning in ends of brackets; with and including 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed; including PVC connections of length 600mm and 15mm dia size with PTMT nuts;and a pair of angle iron brackets duly painted / erecting stand including cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3, complete all as specified and as directed. |
| 24 | S & F in repairs 15 mm nominal size, pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed. |
| 25 | S & Fin repairs 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant complete all as specified and as directed. |
| 26 | S&F IN REPAIRS, PVC connections of length 450mm, 15 mm size with PTMT nuts complete all as specified and as directed. |
| 27 | S & F in repairs 15 mm nominal size, nonrising spindle type fancy angle stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. |
| 28 | S & F in repairs 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 29 | S & F in repairs chromium plated soap dish fancy type oval shaped fixed with brass screws complete all as specified and as directed. |
| 30 | S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. |
| 31 | S & F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. |
| 32 | S&F in repair PVC bathroom mirror cabinet with 4 mm thicklooking glass mirror of overall size 400x500 mm of approved colour and pattern all as specified and directed. |
| 33 | S & FIN REPAIRS,wall mixer with and including over head shower with 115 mm long bend pipe on upper side, connecting legs and wall flangescomplete all as specified and as directed by Engineer-in-charge at site. |
| 34 | S&F in repair rotational moulded polyethylene water storage tank 500 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed |
| 35 | S&F in repair rotational moulded polyethylene water storage tank 1000 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed. |
| 36 | Disconnecting existing tanks of any capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. (Cleaning repairing, etc. measured separately) |
| 37 | Taking down cement plaster, any description, on brick or stone walls, etc.including racking out joints, hacking for key, scrubbing down with water, etc. including removal of rubbish material away from site, complete all as specified and as directed. |
| 38 | M & L for 15 mm thick cement plaster on fair faces of bricks/ concrete surfaces in cement mortar 1:6 including plastered surfaces shall be finished even & smooth without using extra cement all as specified and as directed. |
| 39 | Material and labour for plastering 15 mm thick (in two layers of 10mm and 5mm thk) on fair faces of brick wall or concrete surfacesin cement mortar 1:4 with water proofing compound as per manufacturer\"s printed instruction finished even and fair complete all as specified and directed.Note: Water proofing compound shall be measured and paid for separately. |
| 40 | Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed. |
| 41 | M&L for preparing newly plastered surfaces of ceiling andapplying three coats of whitewash complete all as specified and as directed. |
| 42 | M & L for preparation of new plaster surfaces of wall and applying two coats of acrylic distemper over a coat of primer complete all as specified and as directed. |
| 43 | M&L for preparing of newly plastered wallsurface andapplying two coats of cement base paint with auto roller for making the surface uniform over a coat of Suitable primer complete all as specified and as directed. |
| 44 | S&F in repair PVC (SWR) Pipes single socketed in any length with rubber ring joints, 110 mm bore fixed to walls/floor, complete all as specified and as directed.. |
| 45 | S&F PVC(SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to walls/floor complete including clamps for securing pipe, complete all as specified and as directed. |
| 46 | S & F in repair PVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 47 | S & F in repair SWR branch piece, Wye (45⁰) single, 110 mm dia with inspection door conforming to IS 14735: 1999 complete all as specified and directed. |
| 48 | S & F in repair PVC SWR branch piece, Wye (45⁰) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed. |
| 49 | S & F in repair SWR branch piece, Wye (45⁰) single, 75 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed. |
| 50 | S & F in repair SWR Tee(87.5⁰) single, 110 mm dia with inspection door conforming to IS 14735: 1999 complete all as specified and directed. |
| 51 | S & F in repair SWR vent cowl, 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 52 | S & F in repair SWR vent cowl, 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 53 | S&F stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110mm dia bore of pipe complete all as specified and directed. |
| 54 | S&F stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75mm dia bore of pipe complete all as specified and directed. |
| 55 | S & F in repairs grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and as directed. |
| 56 | S & F in repairs grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40 gms) complete all as specified and as directed. |
| 57 | S&F in repair for PVC (SWR ) gully trap 125/110 mm with grating or without grating and jointing with solvent cement and fixed in position complete all as specified and directed including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 58 | S&F in repairPVC (SWR) floor trap 100 mm with grating including jointing with solvent cementcomplete all as specified and directed by Engr in charge |
| 59 | Supply and fix in repairs PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed. |
| 60 | S & F in repairs sheet glass shelf assembly consisting of 5.50 mm thick glass sheet shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed. |
| 61 | S&F in repairs Corner Glass Shelf of size 300 mm with chromium plated bracket guard and railing, complete all as specified and as directed. |
| 62 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete all as specified and as directed. |
| 63 | M&L for 50 mm dia and 450 mm long medium grade GI pipe spouts with wire gauge on inside mouth to be fixed before water proofing treatment of sunken slabs by cleaning RCC slab surface floors and walls by wire brush and rendering 6 mm thick in CM 1:4 mixed with integral WPC on uneven surface to make it even.Fill it water and check for dampness and seepage, all junctions points of side walls where CI/GI pipe are passing shall be sealed with epoxy mortar.Apply two coats of polymer modified cementious water proofing coating of minimum thickness of 1 mm each layer as per manufacturers instructions on floor & walls (upto 100 mm above FFL)and spray coarse sand on surface when the second layer is still sticky.Apply 20 mm thick plaster in CM 1:4 mixed with integral WPC of approved make on floors and walls including rounding of corners and junctions stoping towareds spouts.All pipes laid in sunken portions shall be covered with 50 mm thick PCC 1:3:6 all around after painting with anti corrosive black japan paint on GI/CI pipes.Test the water proofed area by filling water at least 72 hours and tested for leakage/seepagefor the entire satisfaction of GE.After above said treatment apply two coats of hot blown bitumen @ 1.5 Kg /Sqm for each coat and laying 50 micron black polythene film in floors complete all as specified and directed. (Note : If leakage/Seepage occured after filling water at least 72 hours, the above said treatment will be re-done completely) |
| 64 | M & L for cement concrete in foundation, filling and mass concrete in M5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 65 | Supply and fixing in repair solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed. |
| 66 | S&F in repair of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rails on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. |
| 67 | S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 100 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. |
| 68 | S & F extruded aluminium alloy handle, fabricated type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 69 | S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 70 | Supply and fixing cold rolled stainless steel butt hinges 100 mm long medium weight complete all as specified and as directed. |