| 1 | NOTE:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | Lumpsum price workedout by the tenderer for BUILDING& STRUCTURES WORKS as listed in Schedule ‘A’ Part-I |
| 3 | Lumpsum price worked out by the bidder/ tenderer forSITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule \"A\" Part-II. |
| 4 | Lumpsum price worked out by the bidder/ tenderer for ROAD / HARD STANDINGas listed in Schedule \"A\" Part-III. |
| 5 | Lumpsum price worked out by the bidder/ tenderer forRETAINING WALL / PROTECTIVE WALL as listed in Schedule \"A\" Part-IV. |
| 6 | Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule \"A\" Part-V. |
| 7 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY AND SWT as listed in Schedule \"A\" Part-VI. |
| 8 | Lumpsum price worked out by the bidder/ tenderer for LIGHTNING PROTECTION as listed in Schedule \"A\" Part-VII. |
| 9 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIC SUPPLYas listed in Schedule \"A\" Part-VIII. |
| 10 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule \"A\" Part-IX. |
| 11 | Sch \"A\" Sec-X (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 siginifies this fact only. |
| 12 | M&L for earthing with galvanised steel earth plate electrode of size 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32x6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate pit, funnel, 20 mm dia GI light grade watering pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternatee layer complete all as specified and directed.Note : - The cost of earthlead and protection pipe upto 7.50 m length is includedin the quoted rate of above mentioned item and additional length required beyond 7.50 m shall be measured and paid separately. |
| 13 | S&F LED street light fitting of 35 Watt, including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece, high pressure die castaluminium alloy, monolithic construction totally enclosed, dust and water proof with minimum IP65 protection as per IS-10322-1982(Part-I) with latest amendments and input voltage range 140-300 VAC, frequency 50-60Hz, P.F should be more than 0.9 with THD(I) less than 10%, cool white color and. Fitting should be provided with min 4 KV surge protection, constant current constant voltage driver, high voltage withstanding capacity upto 300 VAC and also have double phase protection, no load, open circuit and short circuit protection, Light fitting suitable for ambient temperature from minus 10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure minimum IP65 degree protection. The lumen output shall not be less than be 110 lumens per watt, life should not less than 40Khr, color index 6000K and must be certified by the relevant test report Fitting should fixed on pole using and including 1.2m long 40mm dia GI pipe light grade bend to shape and fixed using two nos clamps fabricated using MS Flat iron 40x5mm including necessary nut bolts and washers and making electrical connection using 1.5sqmm, 3 core multi-stranded copper conductor PVC insulated and over all PVC sheathed cable form light fitting to junction box complete all as specified and directed |
| 14 | S&F HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 250 x 200 x 105 mm with 16 Amp 4 Way heavy duty terminal block with 6 Amp MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole complete all as specified and directed. |
| 15 | S&F PVC insulated and sheathed cable with stranded copper conductor of size 1.5 sqmm, 3 core, 1100 volt grade complete all as specified and directed. |
| 16 | S&F suspendedtype airtermination network, protective angle should not exceed 45 deg, & supporting steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-67 (13 metres long), pole should be positioned at least 2 mtr form site, height of pole 13 meter, air termination aluminium rod 16 mm dia & 1000 mm long & flexible copper connector 20x3 mm 0.75 Mtr long having suitable size copper lugs at both the end for binding along with misc connected items for fixing all items mentioned complete all as specified and directed. |
| 17 | S&F epoxy powder coated Flameproof/Weatherproof lighting MCB distribution panel board SPN 8 Wayhaving IP66 protection enclosure of Cast Aluminum alloy material including including 01 No. Incommer MCB, 2 pole, 32 Amps \"C\" type and outgoing SP, MCBs 6 to 32 Amps 06 Nos with complete internal common bus-bar & wiring up to terminals complete all as specified and directed. NOTE: Flame proof/ weather proof flexible SS conduit to be used for termination of wiring in DBs and wherever required. Make : Shyam Switchgear (CAT No. SSPL/MCDB/186) / Sudhir Electricals. |
| 18 | S&F epoxy powder coated Flameproof/Weatherproof lighting MCB distribution panel board SPN 8 Wayhaving IP66 protection enclosure of Cast Aluminum alloy material including including 01 No. Incommer MCB, 2 pole, 32 to 63 Amps, \"C\" type and outgoing SP, MCBs 10 Nos 6 to 32 Amps with complete internal common bus-bar &wiring up to terminals complete all as specified and directed.NOTE: Flame proof/ weather proof flexible SS conduit to be used for termination of wiring in DBs and wherever required. Make : Shyam Switchgear (CAT No. SSPL/MCDB/186) / Sudhir Electricals. |
| 19 | S&F Flameproof cum Waterproof LED light fitting of 45 W, suitable for ceiling surface mounting, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen \"A\" clear glass having Anti corrosive epoxy powder coated finishwith all accessories pre wired and including connecting up with three core flexible copper conductor cable of suitable size including flame proof / weather proof fleixible SS conduit pipe 300 mm long terminated in light fitting complete all as specified and directed. |
| 20 | S&F Flameproof cum Waterproof LED Bulk Head light fitting of 30 W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen \"A\" clear glass having Anti corrosive epoxy powder coated finish with all accessories pre wired and including connecting up with three core flexible copper conductor cable of suitable size including flame proof / weather proof fleixible SS conduit pipe 300 mm long terminated in light fitting complete all as specified and directed. |
| 21 | S&F Flame proof/ Weather proof LED light fitting 1x20 Watt, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size including flame proof / weather proof fleixible SS conduit pipe 300 mm long terminated in light fitting complete all as specified and directed. |
| 22 | M&L for earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6.00 mm thick , burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate , using Gl wire 4 mm dia as earth lead electrode bolted or rivetted to earth plate at one end and connected to equipments at another end , GI earth wire encased in and including 15 mm dia Gl \" light grade \" pipe from upper end of earth plate upto equipments , 20 dia bore Gl pipe light grade \" as water pipe from earth chamber to upper edge of earth plate , Test point , Gl funnel with wire mesh fixed on water pipe and PCC (1 : 2 : 4) type B - 1 ( using 20mm graded crushed stone aggregate ) as in pit chamber and RCC pit cover 50 mm thick precast RCC (1 : 2 : 4) type B - 1 , duly reinforced with MS round bars 6 mm dia @ 100 c / c both ways with 10 mm dia MS round bar as in lifting handles , excavation , earth work including laying the GI pipe concealed in floor / wall all as described in electric plate of SSR Part I and testing on completion complete all as specified and directed.Note : - The cost of earthlead and protection pipe upto 7.50 m length is includedin the quoted rate of above mentioned item and additional length required beyond 7.50 m shall be measured and paid separately. |