Tender For Special Repair To Bldg No T-79 (Kote) Of 60 Para Fd Hosp.; 1 Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles complete all as specified and directed. 2 M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed 3 Brickwork with sub-class `B brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified & directed. 4 Taking down cement or cement lime plaster of any description on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. 5 M&L for 10-12mm thick smart care ready mix repair plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacturer instructions )over interior surface of wall complete all as specified and directed. 6 M&L for 10 to 12 mm smart care ready mix repair plaster is a specially designed ready to use cement-based plaster with high quality polymer additives and well graded sand and fillers wihich can be used for plastering (as per manufacturer instructions) over exterior wall surface complete all as specified and directed 7 M&L Preparing newly plastered or un plastered surfaces of wall and applying two coats of oil bound distemper with roller application over a coat of primer over a coat of average 1mm thick wall care putty on new plastered surfaces complete all as specified and directed. 8 M&L for two coats of cement based paint over a coat of primer including preparation of newly plastered surfaces of walls complete all as specified and directed. 9 Dismantling timber scantling 40 Sq cm and over in section, in any position complete all as specified and directed. 10 Dismantling of asbestos cement (corrugated and semi corrugated etc) sheet in roof covering complete all as specified and directed. 11 S&F Fe 410W (Gde E-250) quality A for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, clests etc. 12 S&F for Plate (plane or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conforming to Fe- 410-w complete all as specified and directed. 13 S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 14 S & F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 15 Dismantling wall and ceiling boards( fibre pulp, insulation etc.)or insulation board /slabs/blanket any thickness including cover fillets. 16 S & FGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre. 17 M&L for 4 mm thick non asbestos fibre cement building designer boards fixed in ceiling or laid/inserted to timber/GI/aluminium frame. 18 Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. 19 M&L for coloured glazed ceramic tilesin vertical surface 350 x 250 x 7 mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles including 10 mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed . 20 M&L non skid joint free coloured tiles(1st quality/premium quality) 7 to 8mmthick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exc. 0.18 Sqmas in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:6)complete all as specified and directed. 21 M&L non skid joint free coloured tiles(1st quality/premium quality) 7 to 8mmthick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exc. 0.18 Sqmas in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and directed. 22 M&L 25 mm thickPCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in sub base of flooringfinished even and fair without using extra cement complete all as specified & directed. 23 M&L Machine cutkota stone slab flooring 20-25 mm thick over cement screedbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete laid over and including20mm thickscreed bed CM (1:6) complete all as specified and directed. 24 M&L Machine cut kota stone 20-25 mm thick as in riser of step, skirting,dado and pillar etc. laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding andpolishing laid over and including15mm thick rendering CM (1:4) complete all as specified and directed. 25 M&L PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) 75 mm thick as in sub base of floor/path/paving finished even and fair without using extra cement complete all as specified & directed. 26 M&L Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed in neat cement slurry and pointed in gray pigment cement and pigmentsneat cementto match the colour of tile laid over and including 15 mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and directed. 27 M&L PCC 1:3:6 C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection(75 mm thick) laying in alternate ways finished even and smooth without using extra cement all as specified. 28 Taking up or down 15mm bore steel tubing and connection complete all as specified and directed. 29 S & F 15 mm bore galvanized steel tubes, medium grade for water supply pipes etc, fixed to walls and ceiling or laid in floors complete all as specified and directed. 30 S & F in repair Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed. 31 S & F in repair Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified & directed. 32 S&Fin repair 32/40 mm PVC waste pipe for wash basin and sink complete all as specified & directed. 33 S & F in repair PVC connections 15mm dia with PTMT nuts of length 450mm complete all as specified & directed. 34 S&F in repair 15mm bore Angle Valve fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified 35 S&F in repair Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of 500 ltrs capacity, complete all as specified and as directed 36 S&F in repair mild steel PVC coated drapery rods, 20mm internal diameter including decorative type brackets including fixing arrangement with drilling holes in walls, brackets etc quality and colour as approved by Engineer-in-Charge complete all as specified and directed. 37 Taking down chowkhats or frames with shutters n. exc 1.5 Sqm each complete all as specified and directed. 38 Taking down chowkhats or frames with shutters exc 1.5 Sqm but not exc 4 sqm each complete all as specified and directed. 39 Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm but not exc 4 sqm each complete all as specified and directed. 40 S&F framed work such as in doors or gates of angle or other sections with gussets plates, railsgrills, gratings etc with ends of bars shouldered and/ or riveted or forged into spikes framed girder bar,bared ironed door hung as gate including pintle hinges, stops and hand made sliding bolt and similar work confirming to FE 410 gde-E-250 quality A, complete all as specified and directed. 41 S&F for Mild steel 1.00mm thick plain black sheet in steel gates, wall cladding and similar works cut to size holes punched including round headed screws clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or gturning etc. complete all as specified and directed. 42 S & F steel windows with side hung shutters incl projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed. 43 S & F steel windows with side hung shutters incl projecting type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded all as specified and directed. 44 S & F Stainless steel wire cloth, 0.71 mm nominal dia of wirefixed with tinned tacks, of 20mm meshof stainless steel wire staples complete all as specified and directed 45 S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed. 46 S & F for Steel ventilator with top hung shutters including hinges, steel peg stay, complete all as specified and directed. 47 M&Lcement concretetype B-0, 1:2:4 mix ( 12.5 mm graded agg) filling in door frames, coping, window cill etc complete all as specified and directed. 48 M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed. 49 M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of old steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed. 50 Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceilingroses, pendants, regulators, socket, lamp holders brackets, bulk head fittings, tube light fittings etc complete and removing allretrieved materials toMES storesfor segregation of serviceable /Unserviceable fitting&fixture and also making good disturbed surfaces of wall, floors etc complete all asspecified and as directed by the Engineer-in-Charge. 51 M&L for point wiring concealed type with 1.50 sqmm PVCFRLS insulated, unsheathed, single core, multistranded copper conductorcable 1100 volts grade including 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductorcable as earth continuity conductor drawnin and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, to be terminated in and excluding modular metal GI flush box and its cover plates for fixing modular type switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/bell point controlled by 1 one wayswitch 5/6 Amps complete all as specified & directed. 52 All as per item No-51 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 waymodular switch on the same board with other switches complete all as specified & directed. 53 All as per item No-51 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modularswitch on independent board complete all as specified & directed. 54 All as per item No-51 here in before but point wiring for one six pin socket outlet 16 &6 amps (independent) controlled by one modular switch using PVC FRLS cable of size 2.5 sqmm complete all as specified & directed. 55 Supply and fixingmodular metal GI flush box 1/2 moduleas per site requirement suitable for 20mm dia conduit withand fixed on walls in CM 1:4 and making good the disturbed surfaces of walls as per existing complete all as specified and directed. 56 Supply and fixingmodular metal GI flush boxmodular metal flush boxof 3 module complete all as specified and directed. 57 Supply and fixingmodular metal GI flush boxmodular metal flush boxof 6/8 module complete all as specified and directed. 58 Supply and fix modular white cover plate with frame 1 module for mounting modular switches,sockets and regulators etc complete all as specified and directed. 59 Supply and fix modular white cover platewith frame 3 module complete all as specified and directed. 60 Supply and fix modular white cover platewith frame 6 module complete all as specified and directed. 61 Supply and fix modular white cover platewith frame 8 module complete all as specified and directed. 62 Supply and fix switch modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed. 63 Supply and fix socket outlet, 6 Amps, modular type, 2 module 230 volts complete all as specified and directed. 64 Supply and fix switch modular type, single pole, 16 Amps one module,one way 230 volts complete all as specified and directed. 65 Supply and fix socket outlet, 6/16 Amps, modular type, 2 module 230 volts complete all as specified and directed. 66 Supply & fixrotory stepped type electronic fan regulator modular type,Single module120 watt230 Volts complete all as specified & directed. 67 Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed. 68 Supply and fixing LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holdercomplete all as specified and directed. 69 Supply and fixingin repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 70 Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including fixing arrangment at wall/pole all as directed. 71 Supply and fixing ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all specified and as directed by the Engineer-in-Charge. 72 M&L forsub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:-Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. 73 Supply and fix ceiling fan, 1200mm sweep, minimum 210 CFM, 230 V, BEE 5 star rated, BLDC(brushless direct current motor ) type complete with standard accessories i.e (three blade, 02 Nos canopy, electronic type modular fan regulator 90 to 100 W, down rod of length 1.5 mtr to 2.0 mtr long, 01 No. fan hock, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts,bolts, washers, split locking pins etc), double ball bearing, copper wound with synchronous motor, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm stranded copper conductor 3 core flexible cable cord complete all as specified and directed and deposit old celing fan at E/M store yard. 74 Supply and fixing in repair Distribution board of 12 Waywith 200 amps rated bus bar sheet Metal enclosure double door all as directed by Engr-in-Charge. 75 Supply and fix MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable tiesfor cable management suitable for housing MCCB TPN 415 Volts as incomer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mounting type double door factory fabricated complete without MCB & MCCB but with enclosure blank plate complete all as specified and directed . 76 S&F MCCB of rating 100 Amp, 4 pole, 415 V, AC fixed type with breaking capacity 16 KA DPX³ 160 type, as per ICE- 60947-1 Ics 100% of Icu, Adjustable tripping: 0 - 0.3 - 1 - 3s with adjustable 70% to 100% and thermal magnetic release to be fixed in existing LT panel for taking In coming electric connection for VTPN DB complete all as specified and directed at site. 77 Supply and fixing in repair MCB SPN/RCCB 40 to 63 amp rating 240V, 10KA C. 78 Supply and fixing in repair MCB/RCCB SP 6 to 32 amp rating 240V, 10KA C. 79 M&L forsub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:-Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. 80 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core. 81 Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soilcomplete all as specified and as directed by Engineer-in-Charge. 82 Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge. 83 Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge. 84 Supplying and laying un-reinforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable. 85 M&L for sand cushioning dry fine for cable cushioningbelow and abovethe cable complete all as directed at site by Engr- in-Charge. 86 Supply and fixing GI Pipe 40mmLight grade , for cable protection laid in trench under road or pathor fixed on pole or wall with clamps with all fittings complete all as specified and as directed at site. 87 Earthing complete withgalvanized steel earth plate electrode 60 cmx 60 cm x 6 mm thick buried directlyin ground (earth pit notless than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level,connecting to the4 mm GI wire by means of bolts, nuts , check nuts and washers of galvanized iron andsteelearth wire protected by provision of GI lightgrade pipe15 mmbore including provision of concrete pitmade from PCC ( 1:2:4) type B-1 (using20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angleiron40 x 40 x 6 mm and handle of 6 mmdia MS barmade to shape, GI light grade 20 mmbore pipefor watering perforated atbottom, 1.50metre long placed on top edge of earth plate, common salt &charcoalfilling, withfixing arrangement , funnel, wire mesh and earthwork in hard/dense soil, returning filling in and removal of surplus soilto a distance notexceeding50 metres, all as perelectrical plate No 5 of SSR 2009Part-I and connecting toCBDB’s as specified or indicated including testing on completion.