Construction Of Store Room At Power House Chep Ii- Earth work in excavation by manual means in trenches for foundations, drains,pipes,cables etc. (not exceeding 1.5m in width) and for shafts, wells,cesspits and the like not exceeding 10sqm on plan, including dressing of sides and ramming of bottoms lift up to 1.5m, including getting out excavated earth and disposal of surplus excavated earth as directed:In all kinds of soil for 25m beyond 1m cutting from the edge 2 Providing & laying in position cement concrete of specified grade including curing but excluding the cost of centering & shuttering, all work up to plinth level: 1:5:10 (1cement:5coarse sand:10graded stone aggregate 40mm nominal size) 3 Providing & laying in position cement concrete of specified grade including curing but excluding the cost of centering & shuttering, all work up to plinth level: 1:3:6 with 10% boulders (1cement:3coarse sand:6graded stone aggregate 20mm nominal size) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lifdtup to 1.5m 5 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4(1cement:2coarse sand: 4graded stone aggregate 12.5mm nominal size) and curing complete. 6 Brick work with common burnt clay (non modular) bricks of class designation 7.5 in foundation and plinth including curing in:Cement mortar 1:6 (1 cement:6 coarse sand) 7 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level 8 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60mm pressed, mild steel welded or rigidly fixed together by mechanical means, including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 9 Profile E: Fixing with adjustable lugs with split end tail to each jamb 10 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete:Fixed to steel windows by welding 11 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree,landings,balconies, shelves,chajjas,lintels,bands, plain window sills, staircases and spiralstair cases up to floor five level including curing but excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement:1.5coarse sand:3graded stone aggregate 20mm nominal size) 12 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. 13 Centring and shuttering including strutting, propping etc and removal of the form for.Suspended floors, roofs, landings, balconies and access platforms. 14 Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns 15 12mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand) 16 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick 17 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. 18 Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work 19 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters(35mm): With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws 20 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.First class deodar wood :35mm 21 Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : First class deodar wood : 22 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 23 125mm :For Doors 24 100mm For Windows & Ventilator 25 Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. 26 200mm x 10mm :For Doors 27 100mm x 10mm : For Windows & Ventilator 28 Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete : 29 250x16 mm:For Doors 30 Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :Twin rubber stopper 31 Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm),with double speed adjustment with necessary accessories and screws etc. complete : 32 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 33 Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed withpigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : 34 Supply and placing of soling stones 35 Supplying and stacking at site: Graded crushed stone aggregate of size: 90 mm to 45 mm 36 Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. 110mm dia 37 Carriage of different materials from source to site by MT 38 Sand with average distance of 40 kms 39 Stone aggregate below 40mm with average distance of 3 kms 40 Stone aggregateabove 40mm with average distance of 3 kms 41 cement with average distance of 5 kms 42 Bricks with average distance 90 km 43 Stone with average distance of 8 kms 44 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size G.I box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 45 Group A 46 Group B 47 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 48 Supplying and fixing following size/modules, G.I box along with modlar base and cover plate for modular switches in recess etc. as required4 module(125mm x 75mm) 49 Supplying and fixing following modularswitch/ socket on the existingmodular plate & switch box including connections but excluding modular plate etc. as required. 50 5/6 A switch 51 3 pin 5/6A socket outlet 52 15/16 A switch 53 6 pin 15/16 A socket outlet 54 Supplying and fixing following way, single pole and neutral , sheet steel , MCB Distribution board , 240 volts , on surface /recess ,complete with tinned copper bus bar , neutral bus bar, earth bar , din bar , interconnections , powder painted including etc. as required (But without MCB/RCCB/Isolator)6 way , Double door . 55 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 56 Supplying and fixing fllowing rating double pole,240 v isolator in the existing MCB DB complete with connection testing and commissioning etc. as required 63 A 57 Supplying and fixing PVC batten/ angle holder including connection etc. as required 58 Earthing with G.I earth plate 600 x 600x 6m thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7m long etc.with charcoal/ coke and salt as required. 59 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required(Havels, Bajaj, Philips Anchor, or equivalent brand) 60 10sq.mm ISI marked FRLS PVC insulated single core copper conductor