Construction of additional class room for MS Batapora.(Adv. Cost Rs 102.92lacs) (incl Cost of material + Gst)- 1 Civil part 2 Dsimatling existing single storey building by engaging concrete breakers, manual labour I/C brick work, RCC work, roofing, taking out doors, windows, I/C Disposal of unserciable material within lead of 50mm all complete job 3 Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. 2.6.1 All kinds of soil : 4 Extra rates for quantities of works executed :2.22.1 In or under water and/ or liquid mud, including pumping out water as required 5 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like 6 Supply and laying stone graded material (quarry) I/C Consolidation in layers, I/C cost and carriages of material from source to site 7 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m 8 Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete 9 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 10 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 11 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 12 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 13 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more 14 Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. for mass concrete. 15 Centering and shuttering including strutting, propping etc. and removal of form for:Lintel, beams, plinth beams, girders, bressumers and cantilevers 16 Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platforms 17 Centering and shuttering including strutting, propping etc. and removal of form for:Stairs (excluding landings) except spiral staircases. 18 Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 19 Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts 20 Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stoneaggregate) finished with a floating coat of neat cement including cementslurry and curing complete, but excluding the cost of nosing of steps etc.complete. 50 mm thick with 20mm nominal size stone aggregate 21 Brick work with common burnt clay (non-modular) Bricks of class designation 7.5 in 1:4 cement mortar up to level 5 I/C extra above plinth level incl. extra for bricks work 22 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):First class kail wood 23 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. First class kail wood 30MM thick 24 Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class Kail wood 30 MM thick 25 Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). First class kail wood 30MM 26 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Second Class kail wood 27 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 29 Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete. 1 mm thick 30 Finishing walls with acrylic smooth exterior paint of required shade onNew work (Two or more coats applied @ 1.67 liter/10sqm over andincluding priming coat of exterior primer applied @ 2.20kg/10sqm) 31 Painting with synthetic enamel paint of approved brand and manufactureto give an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 32 Renewing glass panes, with wooden fillets wherever necessary : Float glass panes of thickness 4.0 mm (weight not less than10kg/sqm) 33 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make. In all Clours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) includinggrouting the joints with white cement and matching pigments etc complete using 3 mm spacer and filled with Epoxy Grouting in full 34 Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 35 Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite Work 36 Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. Welded 37 Providing and fixing with high rib profile sheet roofing including vertical/ curved surface including polymer coated J. or L hooks , fixed with polymer coated J or L hooks,bolts and nuts 8mm duiameter with bitumen and G.I Limpet washers ot with G.I limpets washers filled with white lead, including a coat of approved steel primerand two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) exculding the cost of purlins, rafters incl all carriages upto site of work 38 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 39 Providing and fixing 3 layer PP-R (Poly Proylene Random copolymer) pipes conforming to Is: 15801, UV stabilized and anti microbial fusion wielded having thermal stability for hot and cold water supply including all PP-R plain and brass threadedpolypropylene random fittings. this includes testiong of joints complete as per direction of EIC. internal work conceled fixing the pipe with clamps at 1.00 meter spacing cutting chases making good the wall etc I/C all fittings PN-16 pipe, 20mm OD(SDR-7.4) 40 PN-16 pipe, 25mm OD(SDR-7.4) 41 PN-16 pipe, 32mm OD(SDR-7.4) 42 PN-16 pipe, 50mm OD(SDR-11) 43 P/L SWR pipes PVC B-Type 44 PPR Union 25mm 45 P/L SWR pipes PVC B- type i/c all fittings and accessories all complete job150mm I/C COLLARS 46 110mm I/C COLLARS 47 75 mm I/C COLLARS 48 40mm 49 p trap 50 DOOR BEND 110MM 51 DOOR BEND 75MM 52 PVC FLOOR TRAP 53 FLOOR JALLI CP 4 54 Constructing masonry Chamber of specified size, in brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 (1cement :4 coarse sand) and R.C.C. top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including necessary excavation, foundation concrete1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.Chamber 60x60x75 cm 55 Providing and fixing water closet squatting pan (Indian type W.C. pan)with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C.flushing cistern, including flush pipe (of approved make) with manuallycontrolled device (handle lever) conforming to IS: 7231, with all fittingsand fixtures complete, including cutting and making good the walls andfloors wherever required.White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 56 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brasssingle hole basin mixer of approved quality and make, including paintingof fittings and brackets, cutting and making good the walls whereverrequired:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 57 Providing and fixing white vitreous china pedestal for wash basincompletely recessed at the back for the reception of pipes and fittings 58 SUPPLY,INSTALLATION,TESTING AND COMMISIONING HOT WATER GEYSER 50 L CAPACITY 59 Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931 60 Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 61 P/F pvc connections 24/18 62 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:32 mm dia 63 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls andfloors wherever required: W.C. pan with ISI marked white solid plastic seat and lid 64 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backingRectangular 65 Supply and installation health faucet with spray and tube 15mm nominal dia 66 Providing and fixing ball valve (brass) of approved quality,High or low pressure, with plastic floats complete15 mm nominal bore 67 20mm 68 25mm 69 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-incharge. 70 Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brickhoney comb shaft with common burnt clay (non modular) bricks of classdesignation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m longcomplete as per standard design. 71 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube 72 Providing and fixing ISI: 12817 marked Stainless Steel Butt Hinges with Stainless Steel screws etc. complete.125x64x1.90 mm 73 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :100 x 10 mm 74 200 x 10 mm 75 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 100mm 76 125 mm 77 300 mm handles, Main door 78 Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 79 Providing and fixing bright finished brass door latch with necessary screws etc. complete. :300x16x5 mm 80 Providing and fixing plained eaves boarding. 81 P/F of 12mm thick T&G planks made of imported wood (New zealand pine or equivalent) for roof soffits &Ceilingon wood work in false ceiling, partitions sawn and putup in position in budloo wood (Ceiling Joists).including cost of necessary adhesive &cost of nails etc. with necessary cornice of required size complete job.incl cost of nails / screws all complete as approved by Engineer-in-charge(including cost of all material, leads, lifts and carriages etc upto site of work complete). Soffits 82 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 83 CARRIAGE OF MATERIAL BY MECHNICAL TRANSPORT FOR AN AVG LEAD OF 15KMSAND 84 AGGREGATE BELOW 40MM OR Above 85 BRICKS 86 Comsultancy services I/C Architectural. Structural services, soil investigation with spt 10mm depth. 2D drawings, Sections, elevations, plumbing,Electrical, drawings, all complete Job 87 Electric part 88 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Polycab green/ Fenolex/ Havell lifeguard/Salzer/equivalent as directed by engineer incharge.) single core cable in surface / recessed(cutting the wall and making good the samein case of recessed conduit ) medium class PVC conduit/ duct( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.), with modular switch ( Legrand Mylinc /Siemens Marq/schneider Zencelo /Crabtree athena make.), modular plate, suitable GI box as required. 89 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor ( Polycab green/ Fenolex/ Havell lifeguard/Salzer/equivalent as directed by engineer incharge.) single core cable in surface/ recessed PVC conduit,as required. 90 Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Polycab green/ Fenolex/ Havell lifeguard/Salzer/equivalent as directed by engineer incharge.) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) 91 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc /Siemens Marq/schneider Zencelo /Crabtree athena make.) 92 Wiring for 6- 10 amp power plug/ lighting ckt with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Polycab green/ Fenolex/ Havell lifeguard/Salzer/equivalent as directed by engineer incharge.)single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 93 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:-( Legrand Mylinc /Siemens Marq/schneider Zencelo /Crabtree athena make.) 94 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Polycab green/ Fenolex/ Havell lifeguard/Salzer/equivalent as directed by engineer incharge.), single core cable in surface/ recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit as required.(a) 2 X 1.5 sq. mm 95 (d)2 X 6 sq. mm + 1 X 6 sq. mm earth wire 96 ( b )2 X 10 sq. mm + 1 X 6 sq. mm earth wire 97 Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required,complete25mm 98 Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends. 99 Supply installation testing and commissioning of18 W +LEDSurface/recess, square or round Mountedlightluminaryfitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning)of lighting fixtures for a period of Two years ,which includes replacement offixtures ofPhilips/Havell/ Trilux /Wipro/ Crompton make / sample to be approved before installation.. 100 S/F testing and comm. Of36 W + 4 ft.wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with minimum system lumen efficacy of 100 lm/W with THD<10%.( commercial series) CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning)of lighting fixtures for a period of Two years ,which includes replacement offixtures of Philips/Havell/ Trilux /Wipro/ Crompton make / sample to be approved before installation.. 101 Supply installation testing and comm. of flood light 100 W (warm, white), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1,IP66, IK 07, ,with high power LEDs as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1.Preferred make:Philips/ Havell/Wipro/Crompton make. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job. 102 S/F testing and comm. Of MCBs of the below mentioned capacities in sub main controls legrandC curve/ Schinider/ L&T ./equivalent make as directed by engineer incharge.a) 6-32 Amp SP MCB 103 b) 40-63amp DP MCB 104 c) 20-32amp DP MCB 105 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan( USHA/Orient /Bajaj/Crompton/equivalent make as directed by engineer incharge,)with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 106 Supply and fixing of 6 amp/250 V A.C fan dimmerstep type 2 module with cover plateAnchor roma plus/Legrand Mylinc /ABB Tivsha/schneider Livia /Havell Coral make. 107 Supply installationtesting andcomm. Of250mm -300mmsweep exhaust fan Shutter type of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections. 108 Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates. 109 Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,(legrand/ Shinider/Hager/ABB make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door TPN 110 10 way, Double door ( 8+2) SPN 111 Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block. 112 Providingof Chemical earthing as per ISstandards by way of digging 10 deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by 10 SWG copper wire with 1/2 dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound. 113 Supply laying , testing and commissioning of PVC alluminium armoured cable650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard makeas directed by engineer incharge andmaking end termination with brass compression gland and aluminium lugs of required size. c) 35 sq.mm 3.5core 114 Earth work excavationfor cable trench, 2 ft deep with an average breadth of 1.5ft andrefilling of trench with excavated earth after laying of cable and ramming it properly excluding cost of cable 115 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal) 116 Supply installation testing and comm.of invertor battery 150 AH/12 V Exide invatubular/ eq. standard make as directed by engineer incharge. 117 Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel , duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoortype with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account,and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement) 118 Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.Normal INCOMING:(a) 160 amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100%( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make. 119 b) 4 No. of Aluminium Bus Bar of 300 Amp. 120 c)Digital meters and phase indicators -1 set. 121 d) onload Change over switch 100 Amp for generator.Front operated. 122 e) 4 No. of Aluminium Bus Bar of 200 Amp. 123 c)Digital meters and phase indicators -1 set. 124 Inverter Incommer(a) 100 amp DP MCCB 16 K including spreader links including spreader links, icu=ics=100%( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make 125 (b) 200 Amp 2 strip bus bar 126 c)Digital meters and phase indicators -1 set. 127 OUTGOING:c) 40-63amp DP MCB 128 c) space for 12 way MCBs