Tender For Contract For Day To Day Maintenance Of Electric Equipment At Jammu Tawi Golf Course, Sidhra Electrical Part.- 1 Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mmFRLS PVC insulated copper conductor single core cable etc as required (Group-A) 2 Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mmFRLS PVC insulated copper conductor single core cable etc as required(Partially laid conduit) 3 Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC casing & capping, with modular switch, modular plate, suitable PVC box earthing the point with 1.5 sq. mmFRLS PVC insulated copper conductor single core cable etc as required 4 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (Group-A) 5 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc.as required. 6 Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc.as required. 7 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required. 8 Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required. 9 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 10 Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 11 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular SP MCB, C curve including connections, painting etc. as required. 12 Supplying & fixing suitable size PVCbox wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular SP MCB, C curve including connections, painting etc. as required. 13 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular DP MCB, C curve including connections, painting etc. as required. 14 Supplying & fixing suitable size PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular DP MCB, C curve including connections, painting etc. as required. 15 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular DP switch with indicator,including connections, painting etc. as required. 16 Supplying & fixing suitable size PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular DP switch with indicator,including connections, painting etc. as required. 17 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. 18 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 19 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 20 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 21 Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 22 2x1.5Sq.mm+ 1 x 1.5Sq.mm earth wire 23 2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire 24 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 25 2 x 6 sq. mm + 1 x 6 sqmm earth wire 26 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 27 2 x 16 sq. mm + 1 x 6 sq. mm earth wire 28 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 29 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 30 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 31 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 32 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 33 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 34 1 x 1.5 sq. mm 35 2 x 1.5 sq. mm 36 3 x 1.5 sq. mm 37 1x 2.5 sq. mm 38 2 x 2.5 sq. mm 39 3 x 2.5 sq. mm 40 1 x 4 sq. mm 41 2 x 4 sq. mm 42 3 x 4 sq. mm 43 4 x 4 sq. mm 44 5 x 4 sq. mm 45 6 x 4 sq. mm 46 1 x 6 sq. mm 47 2 x 6 sq. mm 48 3 x 6 sq. mm 49 4 x 6 sq. mm 50 5 x 6 sq. mm 51 6 x 6 sq. mm 52 1 x 10 Sq mm 53 2 x 10 Sq mm 54 3 x 10 Sq mm 55 4 x 10 Sq mm 56 1 x 16 Sq mm 57 2 x 16 Sq mm 58 3 x 16 Sq mm 59 4 x 16 Sq mm 60 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as 61 1 Pair 62 2 Pair 63 4 Pair 64 Supplying and fixing of ceiling fan offollowingsweep with 2.25 mfd condenser and 1-6 down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. (As approved site in-charge) 65 900 mm sweep 66 900 mm sweep (3Star) 67 1200 mm sweep 68 1200 mm sweep (1 Star) 69 1200 mm sweep (3 Star) 70 1200 mm sweep Decorative Fan as approved site engineer 71 1200 mm sweep Aero Dynamic type (Silent) 72 Supplying & fixing of Pedestal Fan 400 mm 73 Pedestal Fan 74 Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type)on wall with necessary connection as required. 75 Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. 76 200 mm / 8 sweep exhaust fan 77 225 mm / 9 sweep exhaust fan 78 300mm/12 sweep exhust fan 79 300mm/12 sweep exhust fan (Heavy Duty) 80 380mm/15 Heavy duty 81 450 mm/18 Heavy duty 82 Supplying and fixing of following sizes exhaust fan with PVC blade & Louvers complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. 83 150 mm / 6 sweep exhaust fan 84 200mm / 8 sweep exhaust fan 85 225 mm / 9 sweep exhaust fan 86 250 mm /10 sweep exhaust fan 87 300mm/12 sweep exhust fan 88 Supplying and fixing of fan hook (U hook) on celiling with 4 nos. of anchor fastener on both ends with necessary bolts andnuts and mansonry work as required. 89 Supplying and fixing of following sizes extra down rod with twin core flexible copper wire for ceiling fan. 90 1-0 91 1-6 92 2-0 93 3-0 94 4-0 95 6-0 96 Making round shaped hole on the wall including supply and fixing of necessary cement concrete collar to suit 300 mm heavy duty exhaust fan and finishing the wall to make good. 97 Supplying and fixing of 25 mm thick ply wood with round shaping at the center to fix exhaust fan on ventilator with required accessories. 98 Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 99 4 way (Double door) 100 6 way (Double door) 101 8 way(Double door ) 102 12 way (Double door) 103 16 way (Double door) 104 Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required. 105 4 Way (4+12), (Double door ) (TPN type) 106 6 way ( 4+18), (Double door)(TPN type) 107 8 way (4+24), (Double door) (TPN type) 108 12 way (4 +36), (Double door) (TPN type) 109 Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall bepre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded withBEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendlyGI Electrode Earthing should be maintinance free and does not requireregular manual addition of water . The earthing pit should be covered with PVC cover. 110 Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall bepre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded withBEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendlyGI Electrode Earthing should be maintinance free and does not requireregular manual addition of water . The earthing pit should be covered with PVC cover. 111 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 112 Providing and fixing 20 mm X 3 mm G.I. strip on surface or in recess for connections etc. as required. 113 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 114 Supply, installation, testing & commissioning of maintenance free copper earthing system with 2 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover. 115 Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. 116 Providing and fixing of 20 mm x3mm copper strip on surface or in recess for connections etc. as required. 117 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 118 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make). 119 20 mm 120 25 mm 121 32 mm 122 40 mm 123 20/25 mm flexible pipe 124 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 125 18- 22 watt 126 24 -26 watt 127 36 watt 128 Supplying, installation, Testing & Commissioning of 20/22 watt LED 4 feet tube light fitting/fixture PVC housing with 2000 Lumens and min lumens efficiency100 lumens/watt P.F >.90. having 50000 hours. 129 Supplying, installation, Testing & Commissioning of Decorative LED Hanging Light for officer table as apporved by site Engineer 130 Supplying, installation, Testing & Commissioning of LED Batten Tube fitting 600mm size 10/11 watt Aluminium housing with 1000 Lumens and min lumens efficiency100 lumens/watt P.F >.90 . 131 Supplying, installation, Testing & Commissioning of 36 WATT Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 132 Supplying & fixing of Industrial surface/suspension general purpose 36 watt LED Batten 4 ft Light powder coated aluminium housing with integrated electronic diode with luminius efficancy > 120 (LM 79, 80 certified IP40 THD:<10% P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. 133 Supplying & fixing of Surface/suspension general purpose 20 watt LED Batten 4 ft Light powder coated aluminium housing with integrated electronic diode with luminius efficancy > 120 (LM 79, 80 certified IP40 THD:<10% P. F.≥0.95, CRI >80 , life time of minimum 30000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. 134 Supplying, installation, Testing & Commissioning of36 watt 4 x 1 ft Environmental friendly, new generation, aesthetically desigened, ultra modern recess mounting luminaire with hig brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling HET PMMAdiffuser with minimum system lumen efficacy of 110 lm/W and minimum 3900 lumens withCRCA housingwith APFC constant Current driver for proper driving of LEDs and P.F.>0.95 with THD<10% ,CRI 80.The LED withlife of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700K- 6500K with CRI of minimum 80. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 3kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab. 135 Supplying, installation, Testing & Commissioning of 36 watt 4 x 1 ft Environmental friendly, new generation, aesthetically desigened, ultra modern surface mounting luminaire with hig brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling HET PMMAdiffuser with minimum system lumen efficacy of 110 lm/W and minimum 3900 lumens withCRCA housingwith APFC constant Current driver for proper driving of LEDs and P.F.>0.95 with THD<10% ,CRI 80.The LED withlife of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700K- 6500K with CRI of minimum 80. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 3kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab. 136 Supplying, installation, Testing & Commissioning of20 watt 2 x 1 ft Environmental friendly, new generation, aesthetically desigened, ultra modern recess mounting luminaire with hig brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling HET PMMAdiffuser with minimum system lumen efficacy of 110 lm/W and minimum 3900 lumens withCRCA housingwith APFC constant Current driver for proper driving of LEDs and P.F.>0.95 with THD<10% ,CRI 80.The LED withlife of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700K- 6500K with CRI of minimum 80. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 3kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab. 137 Mirror light LED fitting with 9/11W LED lamp 138 Water tight bulk head LED fitting with 10 watt LED lamp. 139 Providing and fixing of LED Lamp. 140 0.5 w 141 5W 142 9W 143 12W 144 15W 145 18W 146 20W 147 30W 148 Providing and fixing of E-27 LED Light 149 9 watt (warm) 150 9 watt (White) 151 12 watt (warm) 152 12 watt (White) 153 20 watt (warm) 154 20 watt (White) 155 Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 156 45 watt 157 50 watt 158 70/72 watt 159 90 watt 160 100 watt 161 120 watt 162 Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120 deg as per the application and the project requirement deg, suitable table fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 163 50 watt 164 70 watt 165 100 watt 166 150 watt 167 200 wat 168 250 watt 169 Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 170 5/6 watt. 171 8 - 10 watt 172 12 -15 watt 173 18 watt 174 22 watt 175 30 watt 176 Providing & fixing of following accessories. 177 5/6 Amp. 3 pinTop 178 5/6 Amp 2 pin Top 179 15/16 Amp 3 pin top 180 Insulation Tape (ISI brand) 181 Celing Rose 182 2.2/3/3.5 mfd fan condenser 183 Brass batten/ angle holder including (Modular) connection etc. as required. 184 Dimmer Type Regulator (with numbering) 185 5/6 Amp combined 186 15/16 Amp combined 187 Toolkit comprises of plier, screw driver and Phase tester 188 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 189 1 or 2 Module (75mm x 75mm) 190 3 Module (100mm x 75mm) 191 4 Module (125mm x 75mm) 192 6 Module (200mm x 75mm) 193 8 Module (125mm x125mm) 194 12 Module ( 200mm x 150mm) 195 18 Module 196 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 197 1 or 2 Module 198 3 Module 199 4 Module 200 6 Module 201 8 Module 202 12 Module 203 18 Module 204 Supplying and fixing following size/ modules, GI box in recess etc as required. 205 1 or 2 Module (75mm X 75mm) 206 3 Module (100mm X 75mm) 207 4 Module (125mm X 75mm) 208 6 Module (200mm X 75mm) 209 8 Module (125mm X 125mm) 210 12 Module (200mm X 150mm) 211 18 Module 212 Supplying and fixing following size/ modules, PVC box in recess etc as required. 213 1 or 2 Module (75mm X 75mm) 214 3 Module (100mm X 75mm) 215 4 Module (125mm X 75mm) 216 6 Module (200mm X 75mm) 217 8 Module (125mm X 125mm) 218 12 Module (200mm X 150mm) 219 18 Module 220 Supplying and fixing following piano type switch/ socket on the existing box/ cover inculding connection etc. as required. 221 5/6 amp switch 222 15/16 amp switch 223 3 pin 5/6 amp socket outlet 224 6 pin 15/16 amp socket outlet 225 Telephone socket outlet 226 TV Antenna socket outlet 227 Bell push 228 2 pin socket outlet 5 Amp. 229 Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required. 230 5/6 amps switch 231 2 way 5/6 amps switch 232 15/16 amp switch 233 3 pin 5/6 amp socket outlet 234 6 pin 15/16 socket outlet 235 Telephone socket outlet 236 TV Antenna socket outlet 237 DP Switch 32 Amp with Indicator 238 Bell push 239 2 pin socket outlet 5 Amp. 240 Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. The workmanship shall up to the satisfaction of the Engineer in charge. 241 900mm /1200mm / 1400mm sweep AC ceiling fan 242 upto 300mm sweep exchaust fan 243 Servicing of the Geyser etc. as required. 244 Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. (Make as per the gyser installed) 245 Heating Element 246 Thermostat with control 247 Replacement of Assembly complete job 248 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 249 Single pole upto 32 amp. 250 Single pole40 amp. 251 Single pole and neutral upto 32 amp. 252 Single pole and neutral32 amp. (Modular) 253 Double pole upto 32 amp. 254 Double pole40 amp. 255 Triple Pole upto 32 amp. 256 Triple Pole 40 amp. 257 Triple Pole and netural upto 32 amp. 258 Four Poleupto 32 amp. 259 Single pole and neutral 40 Amp 260 Single pole and neutral 63 Amp 261 Single pole and neutral 100 Amp 262 TPN 40 Amp 263 TPN 63 Amp 264 TPN 100 Amp 265 FPN 40 Amp 266 FPN 63 Amp 267 FPN 100 Amp 268 SPDs T1 + T2 - 12.5 KA Cat Nos. 4122 70/71/72/73/76/77 269 SPD 1P+N Right 25 KA 270 SPD 1P Right 12.5 KA 271 2P 25 KA 272 3P 37.5 KA 273 4P 50 KA 274 Supplying and fixing single pole blanking plate in the existing MCB DB Complete etc. as required 275 SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. 276 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type) 277 40 Amp, 25 KA, FP MCCB ICU = 100% ICS 278 63 Amp, 25 KA, FP MCCB ICU = 100% ICS 279 100 Amp, 30 KA, FP MCCB ICU = 100% ICS 280 125 Amp, 36KA, FP MCCB ICU = 100% ICS 281 160 Amp, 36 KA, FP MCCB ICU = 100% ICS 282 200 Amp, 36 KA, FP MCCB ICU = 100% ICS 283 250 Amp, 36KA, FP MCCB ICU = 100% ICS 284 400 Amp, 50 KA, FP MCCB ICU = 100% ICS 285 Electrical Rubber Mathaving thickness 6mm and width 1 Mtr 286 ON Load Change Over Switch FP 100 amp. (Front operated) 287 ON Load Change Over Switch FP 200 amp. (Front operated) 288 ON Load Change Over Switch FP 250 amp. (Front operated) 289 ON Load Change Over Switch FP 400 amp. (Front operated) 290 Aluminium Bus Bar 100 Amp set of 4 strips 18 291 Aluminium Bus Bar 200 Amp set of 4 strips 18 292 Aluminium Bus Bar 300 Amp set of 4 strips 18 293 Aluminium Bus Bar 400 Amp set of 4 strips 18 294 Aluminium Bus Bar 500 Ampset of 4 strips 18 295 Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. 296 Providing and fixing of blades of following fans 297 Wall Fan 298 Ceiling Fan 299 Exhaust Fan 300 Pedestal Fan 301 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 302 10 sq. mm 2 core 303 16sq. mm 2 core 304 25 sq. mm 2 core 305 35 sq. mm 2 core 306 10 sq. mm 4 core 307 16 sq. mm 4 core 308 25 sq. mm 4 core 309 25 sq. mm 3.5 core 310 35 sq. mm 3.5 core 311 50 sq. mm 3.5 core 312 70 sq. mm 3.5 core 313 95 sq. mm 3.5 core 314 120 sq. mm 3.5 core 315 150 sq. mm 3.5 core 316 185 sq. mm 3.5 core 317 240 sq. mm 3.5 core 318 300 sq. mm 3.5 core 319 400 sq. mm 3.5 core 320 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured. 321 6 sq. mm 322 10 sq. mm 323 16 sq.mm 324 25 sq.mm 325 35 sq.mm 326 Flexible Twin core cable whiter wire 327 Labour charge for electrician 328 Labour charge for Helperelectrician 329 Supplying & Drawing of Co- axial TV cable RG-6 grade, 0.7 mm solid copper conductor. 330 Supplying & Drawing of UTP 4 point Cat-6 cable (1 run cable) (D-Link, Schneider, Systimax) 331 Supplying & fixing of following Remote Bells 332 Bell controlled by Single Remote with minimum 15 mtrs range 333 Call bell / Buzzer, Single phase with minimum15 mtrs range 334 Bell controlled by double remote with minimum 15 mtrs range 335 Ding Dong Bell 336 Supplying & fixing of following PVC Gang Box. 337 One way 338 Two way 339 1 + 1 way 340 3 + 1 way 341 4 + 1 way 342 6 + 1 way 343 1 + 1 way (Power) 344 Supplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten). 345 Casing Caping 1 346 Casing Caping 3/4 347 4 Deep Box 348 5 Fan Box 349 Conceeled Box 350 Junction Box (Metal) 351 Supplying and fixing ofPhenolic Laminated Sheet 9 x 11including cutting the space for switches/socket etc. 352 Supplying and fixing of Phenolic Laminated Sheet 9 x 6 including cutting the space for switches/socket etc. 353 Supplying and fixing of Phenolic Laminated Sheet 4 x 4 including cutting the space for switches/socket etc. 354 Supplying and fixing of Phenolic Laminated Sheet 11 x 13 including cutting the space for switches/socket etc. 355 Supplying and fixing of Phenolic Laminated Sheet 6 x 3 including cutting the space for switches/socket etc. 356 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding) 357 0.50 HP 358 1 HP 359 Rewinding of Single Phase, 3 Phase Motors for water lifting (Copper winding) 360 Rewinding of 1 phase (0.5 HP) motor for water lifting (Copper winding) 361 Rewinding of 1 phase (1 HP) motor for water lifting (Copper winding) 362 Dismentalling of Ceiling fan/Wall fan/Exhaust fan and re-fixing the same after repair. 363 Repair of fan by way of replacing damaged bearing, bushes etc as required. 364 Supply of following items 365 Invertor Sinewave 1050-1100 VA 366 Invertor Sinewave 2000-2200 VA 367 Supplying & fixing of Battery 12 Volt. Tubular 150 AH with36 months Guarantee Note.:- (Rs.2500 /Battery has to be deduct for the scrap of old batteries (150 AH)from allotted rate in case of replacement of battery is out of warranty period. 368 Supplying & fixing of Battery 12 Volt. Tubular 200 AH with36 months Guarantee Note.:- (Rs.2500 /Battery has to be deduct for the scrap of old batteries (150 AH)from allotted rate in case of replacement of battery is out of warranty period. 369 Supplying & fixing of PVC Trolley for housing single battery inverter 370 Supplying & fixing of PVC Trolley for housing double battery inverter 371 Repair to PCB of inverter 372 850 VAto 1050 VA 373 1550 VA to 2000 VA 374 Replacement of PCB of inverter 375 850 VAto 1050 VA 376 1550 VA to 2000 VA 377 Repair of Automatic Voltage Stabilizer by way of copper winding etc as required. 378 upto 3 KVA 379 Above 3KVA to 5 KVA 380 Supply, Installation, Testing & Commissioning of IP Dome Camera -Video Standard PAL/NTSC,Image Sensor 1/2.8” CMOS,Number Of Pixels (H × V) 1920(H) × 1080(V),Minimum Illumination 0.0035 lux@F1.2, AGC ON 0 lux with IR ON,S/N Ratio > 50 dB,Electronic Shutter Speed 1s ~ 1/ 100,000s,IR Distance Up to 50m, Day/Night Auto (ICR)/Day /Night/Timing,Backlight Compensation BLC, HLC White Balance Auto/Indoor /Outdoor/ Manual,Wide Dynamic Range Digital WDR,Noise Reduction 3D DNR,Privacy Masking Off / On (4 Areas),Motion Detection Support,Region Of Interest Support (3),Lens 2.8 mm, Fixed Angle Of View H: 105.4°, V: 72.9°,Audio One way, Inbuilt Microphone,Video Compression Resolution H.265 / H.264,Frame Rate Bit Rate Control CBR / VBR Bit Rate 64 Kbps ~ 6 Mbps 1080P(1920×1080), 720P(1280×720), D1(704×576), CIF(352×288), 480×240 Main stream: 1080P/720P (1~25/30fps) Sub stream: D1/CIF (1~25/30fps) Third stream: D1/CIF/480x240 (1~25/30fps),Interoperability ONVIF Profile S, G Maximum Users Access 3 Users Protocols* IPv4, IPv6, TCP/IP, HTTP, HTTPS, UPnP, RTSP, IGMP, SMTP, DHCP, NTP, DNS, DDNS, QoS, 802.1X, UDP, ICMP, ARP, TLS Security User account and password protection, HTTPS, IP Filter, TLS1.2, AES-128 ,Micro SD Micro SD/SDHC/SDXC card slot (128GB),Operating Temperature,Certification CE, FCC, RoHS -30°C ~ 60°C (-22°F ~ 140°F),Ingress Protection IP67IR= 50 Mtrs Make:- Bosch, Pelco, Sumsung, Sony, Honey well WS- 35 series, AXIS 381 Supply Installation Testing and Commissioning of 5MP or better Indoor Bullet camera with 5MP resolution (2592 x 1944) @30fps, H.265/H.264/MJPEG Video Bit Rate 64 Kbps-5 Mbps, Audio Compression G.711/G.711U/ADPCM, Audio Bit Rate 64 Kbps-5 Mbps, Image Sensor 1/2.9 CMOS, Signal System PAL/NTSC, Min. Illumination Color: 0.02Lux@ (F2.0, ACG ON), B/W: 0Lux with IR, Shutter Time 1s to 1/100,000s, Day & Night Dual IR Cut Filter with Auto Switch, Wide Dynamic Range 120dB, Angle Adjustment Bracket, pan: 0° to 360°, tilt: 0° to 75°, rotate: 0° to 360°, Lens type - Fixed, Focus 4mm, Lens Mount M12, Aperture F2.0, Fixed FOV Horizontal field of view: 82.1° (4mm), IR LEDs 2, IR Range Up to 50m, Wavelength 850nm, Alarm Trigger-Motion Detection, Mask Alarm, IP Address Conflict, Protocols TCP/IP, HTTP, FTP, DHCP, DNS, DDNS, MULTICAST, IPV4, NTP, UDP, Telnet. Operating temperature -30°C~600C, 0-95% RH.System Compatibility ONVIF (PROFILE S/G), Protection IP67, Lightning protection, surge protection IR=50 mtrs, SNR > 70 dB, Quad Stream, SD Card Support: Up to 512GB. Make:- Bosch, Pelco, Sumsung, Sony, Honey well WS- 35 series, AXIS 382 SITC of 2MP IP PTZ Camera, with PoE, motorisedvari focal lens for 30x zoom, Minimum Illumination Color: 0.005 lux@F1.6 B/W: 0.0005 lux@F1.6 0 lux@F1.6 (IR light on), S/N Ratio ≥55Db, Effective Pixels 1920(H) x 1080(V), Image Sensor 1/2.8” 2MP PS CMOS (0.9071 centimeters), RAM/ROM 512MB/ 256MB, Electronic Shutter Speed 1/1s~1/30,000s, Focal Length 4.8mm~120mm Focus Control Auto; Semi-auto; Manual White Balance Auto; indoor; outdoor; tracking; manual; sodium lamp; natural light; street lamp Close Focus Distance 1.5 m, Resolution 1080P (1920 × 1080); 1.3MP (1280 × 960); 720P (1280 × 720); D1 (704 × 576/704 × 480); CIF (352 × 288/352 × 240) IVS and face detection support, Weather Proof Standard IP66; TVS 6000 V lightning proof; surge protection; voltage transient protection, Certificates are required ISO 9001, ISO 14001, ISO 27001, CMMI 5, BIS, GDPR and Cyber Security Built-in IR illuminator with 150m viewing distance etc complete as reqd. 383 Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. Make: Finolex/Polycab/Havells 384 Supply, Installation, Testing and comissioning of 16 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 16 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link 385 Supply, Installation, Testing and comissioning of 24 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 24 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link 386 Installation of SSD 250 GB in PC 387 Installation of Anti-virus in PC with 1 year Validity 388 6 TB surveillance Hard disk storage device.7200 RPM 389 Micro SD/SDHC Card 128 GB 390 1 mtr. Cat 6 Networking patch cord cable. 391 3 mtr. Cat 6 Networking patch cord cable. 392 Supply offollowing electrical /networking components. 393 ADSL Modem Router Double Antenna 394 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 μm) made of glass fiber optic, should be fitted at one end with any one type of single ST/E- 2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569 Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge. 395 Supply, Drawing and Testing, of stranded Multi mode (50/125 μm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge. 396 6 fiber 397 12 Fiber 398 24 Fiber 399 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Singlemode Pigtail (9/125 μm (OS1/OS2) made of glass fiber optic, with semi-tight buffer PA/PBT, Ø 0.9 mm, yellow, singlemode G652.D (9/125 μm (OS1, OS2), should have length of min 1.5m, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc. with IEC 61754-20, Should be delta IL < 0.2 dB after 500 mating cycles, It should be Zirconia (ceramic) ferrule with a PC polished endface geometry connector qualified in acc. with IEC 61753-1 for category U (uncontrolled environment). and qualified in acc. with IEC 61753-1, Performance acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, Standard Specification as per requirments.All as per pre approved by Engineer in charge. 400 Supply, installation, Testing and Commissioning of 1000 base-LX/LH single mode/Multi mode fibre to 1000 base-T copper giga bit , Media Convertor complete as required complete in all respect. All as per pre approved by Engineer in charge. 401 Supply , Installation, Testing and Comissioning of Unmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet -10/100 MBPS auto-negotiation RJ45 ports, IEEE 802.3x flow control ,supports auto- MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge 402 4 Port 403 8 Port 404 Supply , Installation, Testing and Comissioning of24 Port Patch Panel 405 Supply , Installation, Testing and Comissioning ofAdaptor for charger 406 Supply , Installation, Testing and Comissioning ofRJ 45 Jack 407 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11/RJ12/RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge. 408 Supply , Installation, Testing and Comissioning ofHDMI Cable 3 Mtrs. 409 Supply , Installation, Testing and Comissioning of HDMI Cable 10 Mtrs. 410 Supply , Installation, Testing and Comissioning ofHDMI Cable 20 Mtrs. 411 Supply , Installation, Testing and Comissioning ofHDMISwitch/Splitterwith 1 input and 2 output 412 Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge 413 2 U Rack 414 4 U Rack 415 6 U Rack 416 9 U Rack 417 Supplying, installation, testing and commissioning of 1 KVA offlineUPS with minimum backup of 20 minutes and having over load, short circuit protection. 418 Supplying, fixing & commissioning of vertical Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required. (5 Star with 8 Bar Pressure) 419 5/6 Ltr 420 35 Ltr 421 50 Ltr 422 Supplying, fixing & commissioning of Horizontal Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required. (5 Star with 8 Bar Pressure) 423 35 Ltr 424 50 Ltr 425 Supply offollowing electrical Heater 426 Single Rod 427 Double Rod 428 Heating Blower 429 Pillar Heater Gopi1500 watt 430 Rod for Pillar Heater Gopi 431 Supply of following electrical appliances. 432 Electric Fly Catcher 433 12 V 43 AH sealed rechargeable battery 434 Tray for setup Box PVC 435 Bread Toaster 436 Juicer Mixer & Grinder (Heavy Duty) 437 Electric Kettle upto 1 Ltr. Capacity. 438 Table Lamp LED as approved bysite engineer. 439 Supply of Highly sensitive Digital Multimeter/clamp meter as per instruction of Engineer incharge 440 Supplying of LED TV (Smart TV) UHD 4K make & model as approved bysite engineer. 441 32 (Only HD) 442 43 443 Refilling of fire extinguisher ABC Type (MAP 90) 06 Kg Capacity. 444 Refilling of fire extinguisher watermist Type Capacity. 445 Refilling of fire extinguisher Co2 Type Capacity. 446 Repair of 5 KVA UPS online by way of Replacing its main circuit board make Microtek 447 Rent Charges for installation of LED Video Wall P3 of size 8 x 12 at JTGC office 448 Rent Charges for installation ofSound System at JTGC 449 Providing and fixing Speaker/Sound Systems for LED Walls maintaining the same by engaging skilled labour and dismantling the same afer completion including two way carriage etc, as required. Complete job on rental basisand any other location as per instuction. 450 Providing & fixing Laptop as per site displaying preloaded Audio-Visual Clippings receivedvia USB Drives, maintaining the same by engaging skilled labour and dismantling the same after completion including two way carriage etc, as required . Complete job on rental basisand any other location as per instuction . 451 Providing & fixing Additional Aluminium twin core cable 10 mm sq.For providing the power supply to make functional the LED walls & LED TVsinstalled in the Jammu. and any other location as per instuction. 452 Hire charges for 50/55 HD LED/Plazma TV complete with mounting arrangement , connections, testing etc. with skilled operator to operate system as and when etc as required. 453 Supplying, installation, testing and commissioning of 120/120 Liters of water Cooler having full stainless steel body, cooling capacity 120ltr/hour and storage capacity 120 ltralongwith PVC connecting pipes as required. (ISO Certified). 454 Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required. 455 (RO + UV + UF mineral control with TDS control ) 456 UV purifier for water cooler 457 Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary.Warrantee.:-2 Years from the date of installation. 458 4 KVA 459 5 KVA 460 Supplying & fixing of M.S Wall/Floor Stand duly powder coated for outdoor unit of Split AC 461 Supplying & fixing of drain pipe for indoor unit 1 462 Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC 463 Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 2.0 Ton AC 464 Supply, erection, testing and commissioning of compressor suitable for 2 Ton split /window type A.C with Gas charging and other required accessories to get A.C workable. 465 Supply, errection, testing and commissioning of compressor suitable for 1.5/1.0 Ton split/window type A.C with Gas charging and other required accessories to get A.C workable. 466 Provision of Gas charging of 2.0 Ton split/ window type A.C including valve etc if required. 467 Installation of 1.5/2 Ton split A.c 468 Servicing of Split AC of All Capacities 469 Visiting Charges of Technician for testing of SplitAC 470 Replacement of defective motor of 471 1.5 Ton Split /Window A.C Outdoor 472 2.0 Ton Split /Window A.C 473 1.5 Ton Split /Window A.C Outdoor (Inverter type) 474 2.0 Ton Split /Window A.C (Inverter type) 475 Replacement of defective capacitor for 476 1.5 Ton Split/Window A.C 477 2.0 Ton Split/ Window A.C 478 Providing & fixing of Blades 479 1.5 Ton Split / Window A.C 480 2.0 Ton Split /Window A.C 481 Providing & fixing of Blower drum (Split AC) 482 1.5 Ton Split A.C 483 1.5 Ton Window A.C 484 2.0 Ton Split A.C 485 2.0 Ton Window A.C 486 Providing & fixing Grill cover to the 487 1.5/2.0 Ton Window A.C 488 Supply, erection, testing and commissioning compressor suitable for 150/150 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable. 489 Supply, erection, testing and commissioning compressor suitable 40/80 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable. 490 Provision of Gas charging of water cooler 150/150 ltr. 491 Provision of Gas charging of water cooler 40/80 ltr. 492 Dismantling of existing Split AC & reinstallation of Split AC with gas top up 493 Dismantling of existing Window AC & reinstallation of Window AC. 494 Dismantling of existing Split AC of All Capacities 495 Dismantling of existing Window AC of All Capacities 496 Repair ofPCB of Split/Window AC 1.5 Ton (Non inverter type AC) 497 Repair ofPCB of Split/Window AC 2.0 Ton (Non inverter type AC) 498 Repair ofPCB of Split/Window AC 1.5 Ton ( inverter type AC) 499 Repair ofPCB of Split/Window AC 2.0 Ton ( inverter type AC) 500 Replacement of PCB 1.5 Ton Split /Window AC (Non inverter type AC) 501 Replacement of PCB 2.0 Ton Split /Window AC (Non inverter type AC) 502 Replacement of PCB ofSplit /Window AC ( Inverter type AC) 503 Supplying and fixing of wall stand for outdoor unit for the split A.C. 504 Replacement of Water purifierchocked candles. ( RO+UV+UF) 505 Replacement of Water Purifier Candles of water cooler 506 Servicing of Water purifier candles. ( RO+UV+UF) 507 Replacement of Pre filter Water Purifier Candles of water cooler (10 inch) 508 Installation of Pre filte rWater Purifier Candles of water cooler with housing (10 inch) 509 Servicing of Water Purifier Candles of water cooler 510 Supplying, installation, testing and commissioning of all in one Hot and Cold RO+UV Water Purifier and Ambient all in one machine 4 Stage i.e. Sediment filter, Pre Carbon , RO & Post carbon ambient capacity at site as per the instructions of Engineer-in-Charge (make Ureka Forbes/AQuaguard/Bluestar.. 511 120 litre capacity (Purechill) 512 Repair of installed Servo Steplizer from OEM by way of :- 513 Supply, Installation , Testing and commissioning of digital Contral Card with sencing circut and protection (High cut, low cut, time delay, phase failer, overload) as approved by Engineer-Incharge 514 Supply, Installation , Testing and commissioning of 10 kg operating voltage 220 515 Supply, Installation , Testing and commissioning of 20 kg operating voltage 220 516 Supply, Installation , Testing and commissioning of 3 kg operating voltage 220 517 Supply, Installation , Testing and commissioning of contactor (3 pole ac with coil voltage 230 V) 518 400 A 519 320 A 520 250 A 521 200 A 522 160 A 523 Repair/Maintance of installed Sensor doors :- 524 Replacement of motors 525 Replacement of sensor 526 Replacement of Belt 527 Balancing of doors 528 Servicing / Greasing of belt 529 Repair/ maintance of installed boom barrier :- (make Secureye) 530 Replacement of motors 531 Supply and Fixing boom 532 Supply of remote 533 Servicing boom barrier 534 Rewinding of motors 535 Supply, Installation , Testing and commissioning ofHeating Rods of existing Sona system. 536 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 537 150 mm width X 50 mm depth X 1.6 mm thickness 538 200 mm width X 50 mm depth X 1.6 mm thickness 539 300 mm width X 50 mm depth X 1.6 mm thickness 540 Repair/Servicing of Water Mist Fans of make Huawei by the OEM Service Provider 541 Servicing of Fan by way of removing calcium from the nossles, tank and connecting pipes by way of chemicals. 542 Replacement of Connecting pipes from tank to fan nossles. 543 Replacement of Motor pumps 544 Replacement of Wheels 545 Replacement of Water Tank 546 Replacement of speed/ water regulator 547 Supply, laying & Fixing of Speaker Lines: 2-Core, 2.5 sq mm High definition Speaker Cable, PVC insulated in PVC jacket laid in existing conduits as reqd. 548 Ceiling Speakers with Power Supply DC :36V, Rated Power (at THD 10%, 240VAC, 1kHz, 4Ω) -- 500 W, DC Power Supply Output Power --- ≥50% rated power, Tone Controls -- Bass: ±10dB at 100Hz ,Treble: ±10dB at 10kHz, DC Power Supply Wire -- 2 x [ ≥16 AWG] Cables, Input Wire -- 6 x Mic 0.7mV/600 Ω, Balanced TRS 2 x Aux 100mV/10 k Ω, RCA Pair, 1 x Line 1v/10k Ω, Balanced TRS, Output Wire -- 1 x P reamp [adjustable 0-200mV]/600 Ω, Balanced TRS/1 x Line Out 1V/1k Ω, Balanced TRS, Speaker Output -- 4Ω/8Ω & 70/100 V, Barrier strip (with touch proof cover), Frequency Response -- 50-15, 000 Hz ±3 dB, Output Regulation --≤3 dB, no load to full load at 1kHz& Signal to Noise Ratio≥70 dB. Make JBL/Bosch 549 Installation of Windows in PC