Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-10-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-10-2025 |
| Sl. No. | Item Description |
| 1 | Comprehensive maintenance ofsingle channel four pipe Laser Aspiration detection unit, The unit should be UL and VDS approved complete with display of all alarm dual filter on board 20000 event log memory worth RS 232 port, The device should support minimum 100 m pipe for each channel and sensivity of 01%, complete all as specified and directed by Engineer in Charge. Note:- The Contractor shall be responsibleto replace all spare parts minor/majorrequired to serviceable of panel, Nothing extra shall be paid to during contract period, If he fail to rectify with 24 Hrs Recovery @ 1000 per day wiil be made in RAR/final Bill. |
| 2 | Comprehensive maintenance of repeater panelhaving display system of existing make and model suitable to incorporate in existing systemhaving LOOP,Fire Red Lamp ON, Open Amber Lamp ON, Short Amber Lamp ON, Isolate Amber Lamp ON Monitor Mains ON 230VDC, Earth Line fault, BAT, low, BAT Discharge, CPU RUN-Processor working Controls, Lamp Test-Healthiness of lamp, Silence -tomute sounders Evacuate-evacuate the building, Reset - To restore system. Contractor shall visit each repeater panel prior quoting the rate to know the current status of respective Panel No claim on whatsoever account shall be entertained during current of work, complete all as specified and directed by Engineer in Charge. Note: The Contractor shall be responsibleto replace all spare parts minor/majorrequired to serviceable of panel, Nothing extra shall be paid to during contract period, If he fail to rectify with 24 Hrs Recovery @ 1000 per day wiil be made in RAR/final Bill. |
| 3 | M&L for Comprehensive maintenance of Microprocessor based panel 1 loop analogue addressable type fire alarmcontrol panel with 80 character CD display with battery backup of 11/2 hours access 500events historical logging having loop Free red lamp on, Open Amber lamp ON, Short - Amber lamp On, Isolate - Amber Lamp On,Control Lamp test-LED Healthy, Silence - TO stop alarm, Evacuate - fire alarm ON, Reset-to Restore system, Monitor : mains ON-230 VAC, BAT ON-system at BAt, System ON -24 VDC, Charger ON 27.3 VDC, Fire sounser ON, Silence - MUTE/ACK, Earth - Line Fault , BAT LOW-Bat Below 22 V. (P4), complete all as specified and directed by Engineer in Charge. Note:- The Contractor shall be responsibleto replace all spare parts minor/majorrequired to serviceable of panel, Nothing extra shall be paid to during contract period, If he fail to rectify with 24 Hrs Recovery @ 1000 per day wiil be made in RAR/final Bill. |
| 4 | S&F in replacement power supply units comprising of battery backup for 11/2 hours charging units, MCB DB and necessary MCB -power supply unit should have capacity to operate on 230 volt AC maininput & provide 24 to 30 volts DC output for powering upTheunit shall also supports battery backup in ase of AC main failure and should have built in charging circuit to batttery suitable toexisting make and model suitable to incorporate in existing system, Contractor shall visit each supply unit prior quoting the rate to know the current status of respective supply unit mechanism No claim on whatsoever account shall be entertained during current of work, complete all as specified and directed by Engineer in Charge. |
| 5 | S&F in replacement of analogue addressable photo electric smoke detector with mounting based LED, address switch to programme the detector from 01-99 with BASEcomplete as required programme the detector rom 01-99with BASE complete as required the contractor shall visit each photo electric smoke detector unit prior quoting the rate to know the current status of respective photo electric smoke detectormechanism No claim on whatsoever account shall be entertained during current of work, complete all as specified and directed by Engineer in Charge. |
| 6 | S&F in replacementof addressable hooter with strobe for alarm annunciation along with all required accessories weather proof, complete all as specified and directed by Engineer in Charge. Note:-(a) The contractor shall check make and model before quoting oftender and inspect hooter unit prior quoting the rate to know the current status of respective hootermechanism.(b) No claim on whatsoever account shall be entertained during current of work complete all as specified and directed by Engineer in Charge. |
| 7 | Taking down U/S & S&F of aspiration system address switch to programme the monitor modules from 01-09 complete as per OEM specification suitebleexisting make and model suitable to incorporate in existing system, complete all as specified and directed by Engineer in Charge. Note(a) The contractor shall check make and model before quoting oftender and inspect monitor modules unit prior quoting the rate to know the current status of respective hootermechanism.(b) No claim on whatsoever account shall be entertained during current of work complete all as specified and directed by Engineer in Charge. |
| 8 | Supply and Laying in replacement ofLT UG XLPE insulated 1100 volt grade heavy duty electric cables with aluminium conductor, cross sectional area 50 sqmm 3.5 core, complete all as specified and directed by Engineer in Charge. Note:-The cost shall be included suitable size of steel gland, thimbles, lugs required to jointing of cable all as specified and directed by Engr-in-charge. |
| 9 | M&L for replacement ofLanding valve 63 mm including jointing with rubber insertion 3 mm thick bolts, nuts and washers etc, complete all as specified and directed by Engineer in Charge. |
| 10 | M&L for replacement of RRL hose ISI markedwith both coupling dia 63mm in 15mtr length for the Loc- Alpha & Bravo, complete all as specified and directed by Engineer in Charge. |
| 11 | S&F in replacement 19mm dia rubber braided hose of 36 mtr length with gate valve and shut of nozzle with working pressure of 12 bar and minimum flow rate 285 OM fixed in existing Hose reel drum of dia 565mm dia cast manual swinging type of Loc- Alpha & Bravo, complete all as specified and directed by Engineer in Charge. |
| 12 | Taking down U/S &S&F in replacement Weather proof cabinet of size 900 x 600x 450mm made out of MS sheet 16 gauge having central opening and 4mm thick glass doors (2 Nos) suitably marked on the outside With Letters \"FIRE HOSE\" cabinet with necessary locking arrangement including all fastens etc and shutter shall be powder coated with signal red colour, shutter with frame fabricated, complete all as specified and directed by Engineer in Charge. Note:- The hose cabinet will be fixed PCC Platform near the Fire Hydrant and cost of PCC flat form and fixing is deemed to be included in quoted cost. |
| 13 | S&F in replacement Female/Male Coupling with Blank Caps/Plugs of 63 mm of working pressure 10.5 Kg/Sqcm ofGun metal/Brass of Loc-WSA, complete all as specified and directed by Engineer in Charge. |
| 14 | S&F in replacement flanged & shore connection of 63 mm outlet of material Gun metal/Stainless Steel with nuts, bolts washer etc of Loc- WSA, complete all as specified and directed by Engineer in Charge. |
| 15 | S&F ofin repair glass of fire hydrant boxes of size 60x60 mminclrubber gasket/seal, complete all as specified and directed by Engineer in Charge. |
| 16 | Supply and install 120 AH, 24 V Maintenance free battery, complete all as specified and directed by Engineer in Charge. |
| 17 | M&L for cleaning of strainer all type and any sizeincluding dismantling and cleaning using Fernox DS-3 cleaner chemical or OEM recommendation and refixing of the same, complete all as specified and directed by Engineer in Charge. |
| 18 | M&L for painting of fire hydrant stand post end flanged 1.5 mtr height with one end bend to 90 degree suitable for double fire hydrant valves including 1 No CI duck foot bend 80 mm double end flanged and 1 no 80 mm 63mm reducer and 1 no 80 mm dia CI buerfly valve completeafter removing all dust, dirt etc and clean the surface thoroughly with two coats of synthetic enamel paint including writing, complete all as specified and directed by Engineer in Charge. |
| 19 | M&L for descaling and servicing the radiator of Diesel engine 62-73 BHP Cap internally and externally by using chemicals, including soldering the copper tubes and tank etc for arresting leakage, complete all as specified and directed by Engineer in Charge. |
| 20 | M&L for descaling and servicing the radiator of Diesel engine 43/52 BHP Cap internally and externally by using chemicals, including soldering the copper tubes and tank etc for arresting leakage, complete all as specified and directed by Engineer in Charge. |
| 21 | M&L for Drain out lived engine oil, clean the oil tank and filling the new engine oil grade 20W 40 as required, complete all as specified and directed by Engineer in Charge. |
| 22 | Supply and filling coolant, complete all as specified and directed by Engineer in Charge. |
| 23 | M&L for Repairing the self Dynamo 12 Volts afterremoving from diesel engine set of any capacity and transporting to an authorised service centre, complete all as specified and directed by Engineer in Charge. |
| 24 | Taking out old U/S and S&FCI body Sluice valve PN 1.6 conforming to ISof size 150 dia complete with nuts, bolts,rubber gaskets etc including, ISI marked, including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 150 mm, complete all as specified and directed by Engineer in Charge. |
| 25 | All as described in item No. 24 but Sluice valve of size 100mm bore. |
| 26 | All as described in item No. 24 but Sluice valve of size 80mm bore. |
| 27 | All as described in item No. 24 but Sluice valve of size 50mm bore. |
| 28 | Taking out old U/S and S&FCI body NRV valve PN 1.6 conforming to ISof size 150 dia complete with nuts, bolts, rubber gaskets etc including, including jointing material such as rubber gasket, bolts, nuts etc suitable for size, complete all as specified and directed by Engineer in Charge. |
| 29 | All as described in item No. 25 but NRV valve of size 100mm bore. |
| 30 | All as described in item No. 25 but NRV valve of size 80mm bore. |
| 31 | All as described in item No. 25 but NRV valve of size 50mm bore. |
| 32 | Taking out U/S battery cell 7 S&F New battery cell12 V 7 AH, Charging voltage Stand by 13.5 V Cyclic 14.7 V, complete all as specified and directed by Engineer in Charge. |
| 33 | S&F in replacement of GI pipe MS pipe nominal dia 100 mm as per IS 3589 (1981) thickness 5.0 mm, including specialjoints complete for deliveryandside including necessarynutsbolts and rubber etc, complete with one coat of red oxide and two coat of black paint on ms pipe, complete all as specified and directed by Engineer in Charge. Note:-The cost shall be inclusive for making suction/delivery pipe from existing pipe from pump to SWT pipe line for delivery includingwelding, bending work, socket, union, bend etc |
| 34 | S&F in replacement of GI pipe and fix MS pipe nominal dia 80 mm as per IS 3589 (1981) thickness 5.0 mm, including specialjoints complete for deliveryandside including necessarynutsbolts and rubber etc, complete with one coat of red oxide and two coat of black paint on ms pipe, complete all as specified and directed by Engineer in Charge. Note:-The cost shall be inclusive for making suction pipe from existing pump to SWT for connection of varies sizes of DI/GI pipe line for delivery includingwelding, bending work. |
| 35 | Taking down U/S &S&F CI body foot valve ISI marked of size 150 dia complete with nuts, bolts, rubber gasketsjointing material suitable for size 150 mm, complete all as specified and directed by Engineer in Charge. |
| 36 | Taking down U/S &S&FCI body foot valve ISI marked of size 80 dia complete with nuts,bolts,rubber gasketsjointing material suitable for size 80 mm, complete all as specified and directed by Engineer in Charge. |
| 37 | Taking down U/S & S&F CI body foot valve ISI marked of size 100 dia complete with nuts, bolts, rubber gasketsjointing material suitable for size 100 mm, complete all as specified and directed by Engineer in Charge. |
| 38 | S&F Mechanical joint suitablefor 150 mm bore CI pipe ,including cutting pipe excavation & earth work etc, nuts, bolts and washers, complete all as specified and directed by Engineer in Charge. |
| 39 | S&F Mechanical joint suitablefor 50/40 mm bore CI pipe ,including cutting pipe excavation & earth work etc, nuts, bolts and washers, complete all as specified and directed by Engineer in Charge. |
| 40 | M&L for run lead joints for 150mm dia spigot and socketed CI pipe fittings including spun yarn etc, complete all as specified and directed by Engineer in Charge. |
| 41 | M&L for run lead joints for 100mm dia spigot and socketed CI pipe fittings including spun yarn etc, complete all as specified and directed by Engineer in Charge. |
| 42 | M&L for run lead joints for 80mm dia spigot and socketed CI pipe fittings including spun yarn etc, complete all as specified and directed by Engineer in Charge. |
| 43 | Dismantling the Electric Induction Motor / submersible motor AC, 3 Phase, 415 Voltsfrom the foundation/ Blast pan SWT of depth of 5-10 mtr Capacity 5 HP by disconnection of Cable and coupling connection of Pump and Re- assembling the complete motor and shifting to the same to its existing location and re-connection all cable and coupling and testing the same on load shifting to the Civil Workshop for the following repair / replacement work, complete all as specified and directed by Engineer in Charge. |
| 44 | Replacement of ball bearing NBC or as per existing make/ model with providing of high grade grease including above quoted rate. |
| 45 | Replacement of re-winding of above motor with same gauge, high grade copper including above quoted rate. |
| 46 | Impellar |
| 47 | Discharge pipe |
| 48 | Control panel |
| 49 | Check valve |
| 50 | Easy Tie Adapter |
| 51 | Clamps |
| 52 | Heat shrink splice kits |
| 53 | Torque arrestor |
| 54 | Safety rope |
| 55 | Dismantling the Electric Induction Motor/ submersible motor AC, 3 Phase, 415 Voltsfrom the foundation/ Blast pan SWT of depth of 5-10 mtr Capacity 7.5/10 HP by disconnection of Cable and coupling connection of Pump and Re- assembling the complete motor and shifting to the same to its existing location and re-connection all cable and coupling and testing the same on load shifting to the Civil Workshop for the following repair / replacement work, complete all as specified and directed by Engineer in Charge. |
| 56 | Replacement of ball bearing NBC or as per existing make/ model with providing of high grade grease including above quoted rate. |
| 57 | Replacement of re-winding of above motor with same gauge, high grade copper including above quoted rate. |
| 58 | Impeller |
| 59 | Discharge pipe |
| 60 | Control panel |
| 61 | Check valve |
| 62 | Easy Tie Adapter |
| 63 | Clamps |
| 64 | Heat shrink splice kits |
| 65 | Torque arrestor |
| 66 | Safety rope |
| 67 | Dismantling the Electric Induction Motor / submersible motor AC, 3 Phase, 415 Voltsfrom the foundation/ Blast pan SWT of depth of 5-10 mtr Capacity 20 HP by disconnection of Cable and coupling connection of Pump and Re- assembling the complete motor and shifting to the same to its existing location and re-connection all cable and coupling and testing the same on load shifting to the Civil Workshop for the following repair / replacement work, complete all as specified and directed by Engineer in Charge. |
| 68 | Replacement of ball bearing NBC or as per existing make/ model with providing of high grade grease including above quoted rate. |
| 69 | Replacement of re-winding of above motor with same gauge, high grade copper including above quoted rate. |
| 70 | Impeller |
| 71 | Discharge pipe |
| 72 | Control panel |
| 73 | Check valve |
| 74 | Easy Tie Adapter |
| 75 | Clamps |
| 76 | Heat shrink splice kits |
| 77 | Torque arrestor |
| 78 | Safty rope |
| 79 | Dismantling the Electric Induction Motor / submersible motor AC, 3 Phase, 415 Voltsfrom the foundation/ Blast pan SWT of depth of 5-10 mtr Capacity 40 HP by disconnection of Cable and coupling connection of Pump and Re- assembling the complete motor and shifting to the same to its existing location and re-connection all cable and coupling and testing the same on load shifting to the Civil Workshop for the following repair / replacement work, complete all as specified and directed by Engineer in Charge. |
| 80 | Replacement of ball bearing NBC or as per existing make/ model with providing of high grade grease including above quoted rate. |
| 81 | Replacement of re-winding of above motor with same gauge, high grade copper including above quoted rate. |
| 82 | Impeller |
| 83 | Discharge pipe |
| 84 | Control panel |
| 85 | Check valve |
| 86 | Easy Tie Adapter |
| 87 | Clamps |
| 88 | Heat shrink splice kits |
| 89 | Torque arrestor |
| 90 | Safety rope |
| 91 | S&F in replacement of Gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 50 mm bore iron pipe and fixed including testing, complete all as specified and directed by Engineer in Charge. |
| 92 | All as per item No. 41 above but having size 40 mm dia bore, complete all as specified and directed by Engineer in Charge. |
| 93 | All as per item No. 41 above but having size 25 mm dia bore, complete all as specified and directed by Engineer in Charge. |
| 94 | S&F in replacement ofRubber coupling TC-16/TC-14 suitable for 40 HP Centrifugal pump, complete all as specified and directed by Engineer in Charge. |
| 95 | S&F in replacement of new star delta starter with auxiliary contracts for remote autoauto, starting, 4 Pole ContactorType TC1-Dx , overload relay Type LR3D/LR1D, auto start switch, 3 position selector switch for SPP auto /SPP / Manual on / off rocket switch, Voltmeterwith selector switch , suppressed scale ammeter, motor ON/Off Trip indicator starting suitable for operating fire pump up to 20 HP jockeyfire pump Note The starter suitable to incorporate in existing enclosure , and contractor shall visit the site before quoting of tender. The contractor shall bound to bring star delta starter as existing model , if he fail to arrange to provide the same model he will arrange a separate enclosure near Existing panel and making all electrical and control wiring arrange free of costModel No BE3SPSSDX254322RS or existing make and model, complete all as specified and directed by Engineer in Charge. |
| 96 | S&F in replacement of new star delta starter with auxiliary contracts for remote autoauto, starting, 4 Pole ContactorType TC1-Dx, overload relay Type LR3D/LR1D, auto start switch, 3 position selector switch for SPP auto /SPP / Manual on / off rocket switch , Voltmeterwith selector switch , suppressed scale ammeter, motor ON/Off Trip indicator starting suitable for operating fire pump up to 40 HP AMP RANGE40-57 forfire pumpNote The starter suitable to incorporate in existing enclosure , and contractor shall visit the site before quoting of tender. The contractor shall bound to bring star delta starter as existing model, if he fail to arrange to provide the same model he will arrange a separate enclosure near existing panel and making all electrical and control wiring arrange free of costModel No C&S BE3SPSSD6335NW359 or existing make and model, complete all as specified and directed by Engineer in Charge. |
| 97 | S&F in replacement Contactor 160A , 415 VAC, 50 Hz complete as per existing Make HPL, complete all as specified and directed by Engineer in Charge. |
| 98 | S&F in replacement Thermal over load relay 9- 32 A, 415 V, 50 Hz as per existing Make & Type, complete all as specified and directed by Engineer in Charge. |
| 99 | S&F in replacement of Electronic timer Star-Delta of 3S-120 Second, complete all as specified and directed by Engineer in Charge. |
| 100 | S&F in repairs MCCBs 400 Amps, 4 Pole having rupturing capacity 36KA, 415 volts including termination point for connection for Loc-P4, complete all as specified and directed by Engineer in Charge. |
| 101 | S&F in repairs MCCBs 250 Amps, 4 Pole having rupturing capacity 25KA, 415 Volts including termination point for connection of Loc-Charlie, complete all as specified and directed by Engineer in Charge. |
| 102 | S&F in repairs MCCBs 100 Amps, 4 Pole having rupturing capacity 16KA, 415 volts including termination point for connection of Loc-Bravo, complete all as specified and directed by Engineer in Charge. |
| 103 | S&F in repairs MCCBs 63 Amps, 4 Pole having rupturing capacity 16KA, 415 volts including termination point, complete all as specified and directed by Engineer in Charge. |
| 104 | Dismantling/taking down the centrifugal pump set of capacity 40 HPfrom foundation after disconnecting of discharge, suction and induction motor connection and shifting to the same to Civil Workshop at Bathindafor the following repair:-Note:- The spares parts given below wherever required for replacement shall be measured and paid separately under relevant items of this Schedule. |
| 105 | Dismantling the complete pump and taken out main shaft and impeller from the pump by disconnection of all nuts, bolts and washers and minor repair and balancing of main shaft and impeller by necessary lathe and machine work including greasing/oiling complete for smooth functioning of pump set and Re-assembling the complete and fixing at site and connection of suction, discharge and the induction motor and testing the same on full load complete replacement with complete new gasket and mild steel nut, bolt, check nut, greasing and washer, complete all as specified and directed by Engineer in Charge. |
| 106 | Replacement of ball bearing NBC 6312 including providing of required grease complete 02 Nos |
| 107 | Cast iron impeller |
| 108 | Bush |
| 109 | Water seal |
| 110 | Re-winding of above motor with same gauge, high grade copper |
| 111 | Dismantling/taking down the centrifugal pump set of capacity 20 HPfrom foundation after disconnecting of discharge, suction and induction motor connection and shifting to the same to Civil Workshop at Bathindafor the following repair:-Note:- The spares parts given below wherever required for replacement shall be measured and paid separately under relevant items of this Schedule.. |
| 112 | Dismantling the complete pump and taken out main shaft and impeller from the pump by disconnection of all nuts, bolts and washers and minor repair and balancing of main shaft and impeller by necessary lathe and machine work including greasing/oiling complete for smooth functioning of pump set and Re-assembling the complete and fixing at site and connection of suction, discharge and the induction motor and testing the same on full load complete replacement with complete new gasket and mild steel nut, bolt, check nut, greasing and washer, complete all as specified and directed by Engineer in Charge. |
| 113 | Replacement of ball bearing NBC 6312 including providing of required grease complete 02 Nos |
| 114 | Cast iron impeller |
| 115 | Bush |
| 116 | Water seal |
| 117 | Re-winding of above motor with same gauge, high grade copper |
| 118 | Dismantling/taking down the centrifugal pump set of capacity 7.5/10 HPfrom foundation after disconnecting of discharge, suction and induction motor connection and shifting to the same to Civil Workshop at Bathindafor the following repair:-Note :- The spares parts given below wherever required for replacement shall be measured and paid separately under relevant items of this Schedule. |
| 119 | Dismantling the complete pump and taken out main shaft and impeller from the pump by disconnection of all nuts, bolts and washers and minor repair and balancing of main shaft and impeller by necessary lathe and machine work including greasing/oiling complete for smooth functioning of pump set and Re-assembling the complete and fixing at site and connection of suction, discharge and the induction motor and testing the same on full load complete replacement with complete new gasket and mild steel nut, bolt, check nut, greasing and washer, complete all as specified and directed by Engineer in Charge. |
| 120 | Replacement of ball bearing NBC 6312 including providing of required grease complete 02 Nos |
| 121 | Cast iron impeller |
| 122 | Bush |
| 123 | Water seal |
| 124 | Re-winding of above motor with same gauge, high grade copper |
| 125 | M&L for replacement of Pump motor coupling fully suitable for 40 HP pump with rubber bushes, complete all as specified and directed by Engineer in Charge. |
| 126 | M&L for replacement of Pump motor coupling fully suitable for 20/10 HP pump with rubber bushes, complete all as specified and directed by Engineer in Charge. |
| 127 | M&L for replacement of UNSV rubber insertion packing suitable for 200mm CI foot valve/suction pipe flanged incl replacement of UNSV nut and bolts, complete all as specified and directed by Engineer in Charge. |
| 128 | M&L for preparation of old painted surface of Fire Hose Cabinet of any sizeby scratching /rubbing down the old paint by wire brush or emery paper and applying two coat of Red oxide Paint (weather proof and rust resistant) etc, complete all as specified and directed by Engineer in Charge. |
| 129 | M&L for preparation of old painted surface of 40 HP Centrifugal Pump and motorby scratching /rubbing down the old paint by wire brush or emery paper and applying two coat of synthetic enamelled paint including 5m suction & 5m delivery pipes etc, complete all as specified and directed by Engineer in Charge. |
| 130 | M&L for preparation of old painted surface of 10 to 20 HP Centrifugal Pump and motorby scratching /rubbing down the old paint by wire brush or emery paper and applying two coat of synthetic enamelled paint including 5m suction & 5m delivery pipes etc, complete all as specified and directed by Engineer in Charge. |
| 131 | M&L for servicing of Diesel Engine of 52/60 BHP with replacement of fuel filter any size as per existing - 1 Set, Air filter - Each, Oil/Lubricant Filter - Each, Engine Oil- 10 Ltr, Coolant up to max level, hose pipe as per existing - Set of two, Battery Terminal - Set of Two, Fuel Pipe fuel Tank to Fuel Filter with Clamp-Each and Radiator cleaning at ATC/ Igloo, complete all as specified and directed by Engineer in Charge. |
| 132 | M&L for Repairing the self starter afterremoving from the Diesel Engine set of capacity 52/60 BHP and transporting to an authorised service centre, complete all as specified and directed by Engineer in Charge. |
| 133 | M&L for repairs to gate and replacement of spindle suitable for 150mm sluice valve, complete all as specified and directed by Engineer in Charge. |
| 134 | S&F in replacement ofGland Dori suitable for pump set any capacity, complete all as specified and directed by Engineer in Charge. |
| 135 | S&F in replacement of High Grade Grease for Pump Set and Motor, complete all as specified and directed by Engineer in Charge. |
| 136 | S&F in replacement of NRV Tikki suitable for 150/100 mm bore NRV, complete all as specified and directed by Engineer in Charge. |
| 137 | M&L for attending complaint day to day like, tightening of nut bolts,finding of leakage in pump any type, checking ofstarting of diesel driven pump, checking of battery thimbles,priming work using separate submersible pump or tanker mounted vehicle for filling of suction/ delivery pipe with water and checking of serviceability of pumpand opening ofvalve /NRV with nut bolt finding of leakage in sluice/ gate valve/ NRVremoving of air release from pump and operating of pump and checking pump is lifting of water with force or not if not then priming of pump with water and find the fault and rectify the fault of pump , ifnot lifting of water then replace gland rope and water seal given in schedule, if battery is found discharge the contractor remove battery from mechanical hydrant pump and transport to workshop for charging purpose and after fullcharge of battery the contractor again transport from work shop to pump and install in pump house and start the engine up to satisfaction of Engr-in-charge .The motor of mechanical hydrant pump/ Electrical operated pump any capacity installed at Bravo / Alpha, Charlie P-IV fire hydrant pump house stopping leakage of GI Pipe upto 150 mm dia by replacing any type of (bend, tee, elbow, reducer, end plug, taper, union, nipple, socket etc), complete all as specified and directed by Engineer in Charge. |
| 138 | M&L for cleaning of/SWT at blast pan of size 10 mtr circumference and depth of 10 mtr by pumping out the water below foot valve and cleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and pumping out soiled watercomplete including writing the capacity and date of cleaning with white paint over black painted surface. The cutting of Grass with root upto depth of 30 cm below ground level around 10mtr of tank of SWT from the periphery of SWT walls, complete all as specified and directed by Engineer in Charge. |
| 139 | M&L for cleaning of/SWT at blast pan of size 15 mtr circumference and depth of 10 mtr by pumping out the water below foot valve and cleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and pumping out soiled watercomplete including writing the capacity and date of cleaning with white paint over black painted surface. The cutting of Grass with root upto depth of 30 cm below ground level around 10mtr of tank of SWTfrom the periphery of SWT walls, complete all as specified and directed by Engineer in Charge. |
| 140 | Dismantling submersible pump set type upto 10 HP 3 phase 415 V from existing location after isolating the electric and earth lead connections, suction and delivery pipes etc opening the pump set, motor rotary and stator etc for repair/overhauling and varnishing and baking the stator winding to enhance the insulation level and reassembling the pump set and reinstalling on foundation frame connecting, testing and commissioning, complete all as specified and directed by Engineer in Charge. Note:- The spares parts given below wherever required for replacement shall be measured and paid separately under relevant items of this Schedule |
| 141 | Cast iron impeller |
| 142 | Bearing suitable for existing submersible pump |
| 143 | Bush |
| 144 | Water seal |
| 145 | Key for main shaft/impeller |
| 146 | Greasing |
| 147 | Dismantling submersible pump set type upto 5 HP 3 phase 415 V from existing location after isolating the electric and earth lead connections, suction and delivery pipes etc opening the pump set, motor rotary and stator etc for repair/overhauling and varnishing and baking the stator winding to enhance the insulation level and reassembling the pump set and reinstalling on foundation frame connecting, testing and commissioning, complete all as specified and directed by Engineer in Charge. Note :-The spares parts given below wherever required for replacement shall be measured and paid separately under relevant items of this Schedule |
| 148 | Cast iron impeller |
| 149 | Bearing suitable for existing submersible pump |
| 150 | Bush |
| 151 | Water seal |
| 152 | Greasing |
| 153 | Key for main shaft/impeller |
| 154 | S&F in repair for wiring with flexible cable6 sqmm 3 core PVC insulated and sheathed sumersible type with stranded copper conductor (for Light), complete all as specified and directed by Engineer in Charge. |
| 155 | S&F in repair for wiring with flexible cable10 sqmm 3 core PVC insulated and sheathed submersible type with stranded copper conductor (for Light), complete all as specified and directed by Engineer in Charge. |
| 156 | S&F ofin repair FBC 2 way inlet breeching body gun mental or aluminium alloy or cast iron working pressure 150PSI/10.5 kg/cm2 DRE-2W-02 way, complete all as specified and directed by Engineer in Charge. |
| 157 | S&F ofin repair double outlet type landing valve of product code No.LV-DOT-02 made in gunmetal 63/80/100mm NB flanged inlet as per PN16, complete all as specified and directed by Engineer in Charge. |
| 158 | S&F ofin repair multi proposecombination flow nozzle ofN-MP-25 size 19 mm BSP (F) threads, complete all as specified and directed by Engineer in Charge. |
| 159 | S&F ofin repair inlet blank caps/plugs of size 63 mm as per 336/IS 903 working pressure 150 PSI/10.5KG/CM2, complete all as specified and directed by Engineer in Charge. |
| 160 | M&L for Scraping out silt, algae, vegetation fromside wall under ground treated water sump by using broom, steel wire brush and washing the side walls with bleaching powder solution etc. Dewatering & Cleaning ofunder ground treated water sump of Capacity 200,000 Gallons involving the following cleaning process, complete all as specified and directed by Engineer in Charge. |
| 161 | Note for Item No 78(a) De-watering shall be carried out by using high pressure Water Jet Machine complete all as directed.(b) Total Removal ofall masses, algae, dirt including removal of dirty water/ Mud/ Mudy Water at locations as directed by Eingineer in Charge.(c) Scrubbing of Internal Surfaces and Cleaning of Walls, Ceiling & Floors with wire Brush by applying Bleaching powder and again clean with Fresh Water repeatedly by using high pressure Jet Pump.(d) Pumping Out/ Removal of all dirt particles including muddy water, Fungus struck on its surfaces and sludge as directed.(e) Applying One coat of Anti-bacterial Sterilization Spray to walls, Floors & Ceilingincluding external surface of reservoirs which is effective against all pathogens all as directed.(f) Cutting & Removing of Vegetation growth from the periphery of the tank and its vicinity at a radius not less than 10 Metre from edges, complete all as specified(g) “Date of Cleaning” should be written over the outer surface of tank with Synthetic Enamel Paint with lettering not less than 100mm height as directed by Engineer-in-Charge.Note:-(i)Rate shall be inclusive for all T&P/Materials required for dewatering and nothing will be paid extra on this account. The water from sump will be discharged at a location decided by engr-in -charge.(ii)The contractor shall be deployedman power to clean the sump as per requirement given by Engineer in Charge in works site order book. If they failed to clean in within a week, the payment shall not be made to contractor and the recovery shall be made @ Rs 700 per day till execution. (iii) Unit rate quoted by contractor includes all lightning arrangements, safety arrangements for cleaning shall be arranged by the contractor. (iv) Applying three coats of whitewash on old decorated surfaces of existing sump/tank above ground level after preparation of surfaces by removing all loose dirts scrubbing with wire brushes/brooms, rates for same deemed to be included in quoted rates. |
| 162 | All as per item No.78 above but 100,000 gallons capacity Over Head reservoir on 18.50 Metre staging. (OMQ) Mandir/Silver |
| 163 | All as per item No. 78 above but 50,000 gallons capacity Over Head reservoir on 18.50 Metre staging. (KV / Pichora) |
| 164 | All as per item No. 78 above but 60,000 gallons capacity Over Head reservoir on 18.50 Metre staging.(NCE 17 SQN) |
| 165 | All as per item No. 78 above but 40,000 gallons capacity Underground Sump reservoir.(Mini Pump/Ahuja/MAP SMQ) |
| 166 | M&L forremoving of mud and sludge from the tank by manually and Scraping out silt algae, vegetation from side walls of level tank by using broom, steel wire brush and washing the side walls with bleaching powder solution etc. The Dewatering of water up to the bottom level andCleaning ofReservoir/ Underground Sump of 100,000 Gallons capacity (Level Tank) involving the following cleaning process, complete all as specified and directed by Engineer in Charge. |
| 167 | Note of Item No:- 79(a) De-watering up to bottom level shall be carried out by using high pressure water jet complete all as directed.(b) Total Removal ofall masses, algae, dirt including removal of dirty water/ Mud/ Mudy Water by Suction Jet Pumps up to a safe distance not exc 100 Mtr from Sumpasdirected by Engineer in Charge.(c) Scrubbing of Internal Surfaces and Cleaning of Walls, Ceiling & Floors with wire Brush by applying Bleaching powder and again clean with Fresh Water repeatedly by using high pressure Jet Pumpcomplete all as directed.(d) Pumping Out/ Removal of all dirt particles including muddy water, Fungus struck on its surfaces and sludge by Vacuum Pump specially designed all complete.(e) Applying One coat of Anti-bacterial Sterilization Spray to walls, Floors & Ceiling which is effective against all pathogens all as directed.(f) “Date of Cleaning” should be written over the outer surface of Tank with Synthetic Enamel Paint with lettering not less than 100mm height as directed by Engineer in Charge.(g) Cutting & Removing of Vegetation growth from the periphery of the tank and its vicinity at a radius not less than 10 Metre from edge, complete all as. Note :-(i)Rate shall be inclusive for all T&P/materials required for dewatering and nothing will be paid extra on this account. (ii) The contractor shall be deployed man power to clean the sump as per requirement given by Engineer in Charge in works site order book. If they failed to clean in within time 07 days, the payment shall not be made to contractor and the recovery shall be made @ Rs 700/- per day till execution of work. (iii) Unit rate quoted by contractor includes all lightning arrangements, safety arrangements for cleaning shall be arranged by the contractor.(iv) Applying three coats of whitewash on old decorated surfaces of existing sump/tank above ground level after preparation of surfaces by removing all loose dirts, scrubbing with wire brushes/brooms, rates for same deemed to be included in quoted rates. |
| 168 | M&L for Pumping out the water from raw water tank of size 80mx80mx5.17m of water capacity 50 Lakh gallon to another tank upto top of mud sludge/contaminated muddy water with the help of Electric Motor & Pump Set upto entire satisfaction of Engineer-in-Charge. NOTE:-Rate shall be inclusive for all T&P/material required for dewatering and nothing will be paid extra on this account.. (muddy water will be discharged at another location decided by Engr-in-charge ) |
| 169 | M&L forremoving out of allmud and sludge from the tank by manually and Scraping out silt algae, vegetation fromside walls of Reservoir by using broom, steel wire brush and washing the side walls with bleaching powder solution etc complete all as specified and directed by Engr-in-Charge. M&L for Dewatering & Cleaning ofReservoir having capacity of50,00,000 Gallons involving the following cleaning process, complete all as specified and directed by Engineer in Charge. |
| 170 | Note for Item No 81(a) De-watering up to bottom level shall be carried out by using high pressure Water Jet Pump complete all as directed.(b) Total Removal ofall masses, algae, dirt including removal of dirty water/ Mud/ Mudy Water by using high pressure Water Jet Pump up to a safe distance minimum 1000 Mtr from Reservoir Boundaryasdirected by Engineer in Charge.(c) Scrubbing and Cleaning of Walls & Bottoms of reservoir with wire Brush by applying Bleaching powder and again cleaning with Fresh Water repeatedly by using high pressure Jet Pump complete all as directed as per satisfaction of Engineer in Charge.(d) Applying One coat of Weather Proof cement base paint on surfaces of walls of reservoir complete all as directed.(e) Cutting and removing of vegetation growth from periphery of tank upto 5 metre from fencing of raw water tank including the vegetation on fencing.(f) “Date of Cleaning” and capacity of tank should be written over the outer surface of tank with synthetic Enamel paint with lettering not less than 100mm height as directed by Engr-in-Charges (g) Scrubbing of internal surfaces and cleaning of walls, floors which dislodge the layer of dirt, fungus struck on its surface and applying Anti-bacterial Sterilization Spray to walls & floors with the help of Electric motor & pump set upto entire satisfaction of Engineer-in-Charge.Note:-(i)Rate shall be inclusive for all T&P/materials required for dewatering and nothing will be paid extra on this account. (ii) The contractor shall be deployed man power to clean the tank as per requirement given by Engineer in Charge in works site order book. If they failed to clean in within 20 days (after hand over site to contactor), the payment shall not be made to contractor and the recovery shall be made @ Rs 700 per day till execution of work. (iii) Unit rate quoted by contractor includes all lightning arrangements, safety arrangements for pumping shall be arranged by the contractor. (iv) Applying three coats of whitewash on old decorated surfaces of existing sump/tank above ground level after preparation of surfaces by removing all loose dirts scrubbing with wire brushes/brooms, rates for same deemed to be included in quoted rates. |
| 171 | M&L for Scraping out silt algae, vegetation from side wall of flocculate cum sedimentation tank by using broom, steel wire brush and washing the side walls with bleaching powder solution etc, complete all as specified and directed by Engineer in Charge. M&L for Cleaning and dislodging of flocculate cum sedimentation tank of 14.60 Mtr dia and 3mtr height including drain out of water from the tank to sludge cell and removing of sand/mud and sediment of alum from the bottom portion of the tank (17 metr depth) and taken out the sludge/mud from the tank with high pressure water jet to remove all masses,algae,dirt and removal of dirt with wire brush by applying bleaching powder and cleaning entire surface repeatedly with fresh water and pumping out soiled ,muddy water from tankcomplete water along with sludge by Vacuum Pump specially designed and disposal of the same to a safe distance, complete all as specified and directed by Engineer in Charge. Note:-(i)Rate shall be inclusive for all T&P/materials required for dewatering and nothing will be paid extra on this account. (ii) The contractor shall be deployedman power to clean the tank as per requirement given by Engineer in Charge in works site order book, if contractor failed to clean in within time frame i.e 09 days from the starting of dates of work , the payment shall not be made to contractor & recovery shall be made @ Rs. 700/- per day till execution of work. (iii) The contractor will empty flocculate in the morning and will do the cleaning work till evening after which water will be supplied in flocculate to give supply to station and the process will repeat until flocculate is completely cleaned. (iv) \"Date of Cleaning” and capacity of tank should be written over the outer surface of tank with synthetic enamel paint with lettering not less than 100mm height as directed by Engr-in-Charges.(v) All machineries & grills of flocculate to be painted. The rates of painting is included quoted rates. |
| 172 | M&L for Scraping out silt algae, vegetation from side wall of sludge tank by using broom, steel wire brush and washing the side walls with bleaching powder solution etc, complete all as specified and directed by Engineer in Charge for Cleaning and dislodging of sludge tank of size 11mx9mx3m including pumping out the muddy water from the tank and removing of inludge/mud from the bottom portion of the tank (1.10 Mtr depth) with high pressure water jet to remove all masses,algae,dirt and removal of dirty water along with sludge using sludge machine and disposal of the same to a safe distance as directed and including scrubbing of internal surfaces and cleaning of walls, floors & ceilingwhich dislodges the layers of dirt, fungus struck on its surface and applying one coat of Anti-bacterial sterilization spray to walls, floors & ceiling external surfaces of reservoirs, complete all as specified and directed by Engineer in Charge. Note:-(i) Rate shall be inclusive for all T&P/materials required for dewatering and nothing will be paid extra on this account. (ii) The contractor shall be deployed man power to clean the tank as per requirement given by Engineer in Charge in works site order book. If they failed to clean in within 7 days, the payment shall not be made to contractor and the recovery shall be made @ Rs 700 per day till execution of work.(iii) “Date of Cleaning” should be written over the outer surface of tank with synthetic enamel paint with lettering not less than 100mm height as directed by Engineer-in-Charge.(iv) Cutting & Removing of vegetation growth from the periphery of the tank and its vicinity at a radius not less than 10 Metre from edge, complete all as. (v) To whitewash the portion of tank above ground level (start by thoroughly cleaning the surface to remove any loosepaint,dirt etc) rates is included in quoted rates. |
| 173 | M&L for painting by bluse paint of incoming and delivery pipe line 150/200 mm dia of CI/DI pipe line at the height of 20 mtr OHT ( Total OHT 07 Nos)and writing the details of tank with two coats of synthetic enamel paint, complete all as specified and directed by Engineer in Charge. Note:-The quoted unit rate shall include provision of scaffolding for painting on OHT incoming & Delivery pipe line upto a height of 20 Metre including M&L for erecting with steel structure for repairing/ painting work on OHT and removing of scaffolding/ Steel structure including transportation & labour arrangement for removing all dust, dirt etc. from the site as directed by Engineer in Charge. |
| 174 | M&L for Preparation of old painted surface of Flocculate and all Machineries installed at filtration plant ie. Motors, Panel, Grills, Railings, machineries at coagulation plantetc. brooming down, scrubbing with steel wire brush, scrapping paintedsurfaces and applying two coat of synthetic enamel paint (grey) etc, complete all as specified and directed by Engineer in Charge. |
| 175 | M&L for Taking out the old/unserviceable filter media gravel of any size from beds and depositing the same not more than 150mtr away from filter bed etc The cost deemed to be including cleaning and scrubbing the all walls with wire brush and two coat ofwhite cement&washing the same with potassium per magnate, complete all as specified and directed by Engineer in Charge. Note:-The Filter media will be remove in the plant within 02 days from starting date of work in each pressure sand filter, if contractor failed to clean in 02 days, the recovery will be made @700/- per day till completion of job. |
| 176 | Supply and filling layer of fine brown/ white sand and coarse brown sand in filter media inside filter bed grade size 1mm to 1.5mm (as per sample) the depth of sand media varies between 60cm to 80cm very fine and 1 mm accumulated at top of the filter and coarse sand 1.5mm grade below the fine sand etc, complete all as specified and directed by Engineer in Charge. Note:-The Filter media fill in the sand at filter plant within 02 day from the starting of dates of work in each pressure sand filter. if contractor failed to fill filter media within 02 day, the recovery will be made Rs @ 2000 Per day till completion of Job. |
| 177 | All as per item No. 87 here-in-before but intermediate 2nd layer of gravel graded size 12mm to 20mm. |
| 178 | All as per item No.87 here-in-before but intermediate 3rd layer of gravel graded size 6mm to 12mm. |
| 179 | All as per item No. 87here-in-before but intermediate 4th layer of gravel graded size 1mm to 6mm. |
| 180 | M&L for Cleaning bed by wire brush on floor wall sides, channel of the Empty filter bed Air hole, with high pressure water jet to remove all masses, algae, dirt and removal of dirty water and including scrubbing of internal surfaces and cleaning of walls, floors & ceiling which dislodges the layers of dirt, funges struck on its surface and connecting pipe to make bed free from floor vegetation on the same bed filter compartment of size 4.0mx 4.0m x3.0m and disinfecting by disinfecting material etc, complete all as specified and directed by Engineer in Charge. Note:-(i) Rate shall be inclusive for all T&P/materials required for dewatering and nothing will be paid extra on this account. (ii) The contractor will be deployed additional man power to clean the sump as per periodicity given by Engineer in Charge in works site order book. If they failed to clean in within 10 days from the starting of dates of work , the payment shall not be made to contractor &the recovery will be made @1000/- per day till completion of job. |
| 181 | M&L for Cleaning of back wash line inside the filter bed externally by scraping and by cleaning the air holes by drill machine/Air blower and making the pipe valley cleaned and functional & applying two coats of synthetic enamel paint on the metal pipes including preparation of surface etc, complete all as specified and directed by Engineer in Charge. |
| 182 | M&L for Dewatering & Cleaning of underground (old) treated water sump of 1,50,000 Gallons capacity involving the following cleaning process, complete all as specified and directed by Engineer in Charge. |
| 183 | Note for Item No 90(a) De-watering shall be carried out by using high pressure water jet machine complete all as directed.(b) Total Removal ofall masses, algae, dirt including removal of dirty water/ Mud/ Mudy Water by Suction Jet Pumps complete all asdirected.(c) Scrubbing of Internal Surfaces and Cleaning of Walls, Ceiling & Floors with wire Brush by applying Bleaching powder and again clean with Fresh Water repeatedly by using high pressure Jet Pumpcomplete all as directed.(d) Pumping Out/ Removal of all dirt particles including muddy water, Fungus struck on its surfaces and sludge by Vacuum Pump specially designed all complete.(e) Applying One coat of Anti-bacterial Sterlization Spray to walls, Floors & Ceiling which is effective against all pathogens all as directed.(f) “Date of Cleaning” should be written over the outer surface of Tank with Synthetic Enamel Paint with lettering not less than 100mm height as directed by Engineer in Charge.(g) Cutting & Removing of Vegetation growth from the periphery of the tank and its vicinity at a radius not less than 10 Metre from edge, complete all as. Note:- (i)Rate shall be inclusive for all T&P/materials required for dewatering and nothing will be paid extra on this account.(ii) The cleaning of both old sumps parted within a single sump is included in quoted rate.Both parted sumps within a single sump will be measured as one quantity.(iii)The contractor will be deployed additional man power to clean the sump as per periodicity given by Engineer in Charge in works site order book. If they failed to clean in within time frame, the payment shall not be made to contractor and the recovery shall be made @ Rs 700 per day till execution of work. (iv)Unit rate quoted by contractor includes all lightning arrangements, safety arrangementsfor pumping shall be arranged by the contractor. |
| 184 | M&L for Cleaning and dislodging of backwash tankover bldg of size 11mx3mx1.5 m including pumping out the muddy water from the tank and removing of inludge/mud from the bottom portion of the tank with high pressure water jet to remove all masses,algae,dirt and removal of dirty water along with mud/sandusing pressure jet machine and disposal of the same to a safe distance as directed and including scrubbing of internal surfaces and cleaning of walls, floors & ceilingwhich dislodges the layers of dirt, funges struck on its surface and applying one coat of Anti-bacterial sterilization spray to walls, floors & ceiling external surfaces of reservoirs, complete all as specified and directed by Engineer in Charge. Note:-(i) Rate shall be inclusive for all T&P/materials required for dewatering and nothing will be paid extra on this account. (ii) The contractor will be deployed additional man power to clean the sump as per periodicity given by Engineer in Charge in works site order book. If they failed to clean in within time frame, the payment shall not be made to contractor and the recovery shall be made @ Rs 700 per day till execution of work.(iii) “Date of Cleaning” should be written over the outer surface of Tank with Synthetic Enamel Paint with lettering not less than 100mm height as directed by Engineer in Charge.(iv) Cutting & Removing of Vegetation growth from the periphery of the tank and its vicinity at a radius not less than 10 Metre from edge, complete all as. |
| 185 | S&F in repairs 3 pole contactor with 220/440 volt coil suitable for MNX 18 starter as per site requirement, complete all as specified and directed by Engineer in Charge. |
| 186 | S&F in repairs 3 pole contactor with 220/440 volt coil suitable for MNX 25 starter as per site requirement, complete all as specified and directed by Engineer in Charge. |
| 187 | S&F in repairs 3 pole contactor with 220/440 volt coil suitable for MNX 32 starter as per site requirement, complete all as specified and directed by Engineer in Charge. |
| 188 | S&F in repairs 3 pole contactor with 220/440 volt coil suitable for MNX 45 starter as per site requirement, complete all as specified and directed by Engineer in Charge. |
| 189 | S&F in repairs 3 pole contactor with 220/440 volt coil suitable for MK II starter, complete all as specified and directed by Engineer in Charge. |
| 190 | S&F in repairs contactor coil 220/440 volt suitable for DOL/ Star Delta starter as per site requirement, complete all as specified and directed by Engineer in Charge. |
| 191 | S&F in repairs timer switch suitable for star delta starter as existing, complete all as specified and directed by Engineer in Charge. |
| 192 | S&F in repairs bi-metal over load relay as per site requirement, complete all as specified and directed by Engineer in Charge. |
| 193 | Supply, installing testing and commissioning in replacement of factory made and tested (Including CPRI TEST Certified) outdoor type floor mounted LT panel board with top canopy, cubical type suitable for 415 volts 3 phase, 4 wire 50 Hz, AC supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phase installed on porcelain/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15mm thick CRCA MS sheet and angle iron frame 40 × 40 ×6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with approaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following :- |
| 194 | Note of Item No-100INCOMING :-(a) Mains MCCB 4 pole 400 Amps 50 KA with adjustable setting, 415 Volts with breaking capacity 36 KA- 01 Nos. (b)On load Changeover switch 400 amps panel mounted with all connections -01 Nos. (c) Digital type voltmeter 0-500 volts and with selector switch -01 Nos.(d)Digital Amp meter with CTs & built in selector switch -01 Nos.(e) Indication lamp RYB-01 Set.OUTGOING -(a)MCCB 4 pole 200 Amps, 415 Volts with breaking capacity 36 KA-01 Nos.(b)MCCB 4 pole 160 Amps, 415 Volts with breaking capacity 25 KA-02 Nos.(c)MCCB 4 pole 125 Amps, 415 Volts with breaking capacity 25 KA-02 Nos. |
| 195 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying of CI/DI/GI steel water tubes etc, and getting out in any type of soil, complete all as specified and directed by Engineer in Charge. |
| 196 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engineer in Charge. |
| 197 | Removing excavated material/surplus soil not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed by Engineer in Charge. |
| 198 | M&L in replacement of XLPEinsulated, armoured, heavy duty electric LT UG cable with multi-stranded aluminium conductor,1100 Volts grade, cross sectional area 16 Sqmm x 4 core, laid in trenches/ passing through pipe/ duct or fixed to wall including provision of necessary lugs/ thimbles/ ferrules, connecting up, testing and commissioningcomplete including taking down existing unserviceable LT UG cables of any description and size and making good disturbed surfaces, complete all as specified and directed by Engineer in Charge. Note:- Excavation, earth work,riddled earth cushioning, bricks/GI pipe for protection shall be measured and paid separately under relevant items of this schedule. |
| 199 | S&F Double wall corrugated high density polymer ethyl pipe of size 25mm outer diawith ISI marked (IS 14930- 2001 ), laid in trenches /floors & fixed on wall/ pole with & including necessary fittings such as bends, sockets & other connected accessories etc forlaying of electric cables, complete all as specified and directed by Engineer in Charge. |
| 200 | S&F LED street light fitting 60 Watt 230 V AC outdoor type 5700 K with high pressure die cast aluminium hosing along with prismatic polycarbonate modular secondary lens optics with IP 66ingress protection . 4KV in-built and 10 KV external surge protection with top opening driver cover for easy maintenance with efficacy not less than 120 lm/W heat resistant. The LED driver shall be of isolated type with constant current constant voltage topology to ensure optimum driving of LEDs. The LED streetlight shall have power factor more than 0.95. The optical compartment shall be covered with heat resistant toughened glass for safety. The LED Street light should be top maintainable for easy maintenance LED street light shall be of Integral type complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, complete all as specified and directed by Engineer in Charge. Note :-(i)Driver and luminaire of LED fitting shall be of same manufacturer.(ii) All T&P ie ladder, Tools, Safety gloves etc will be provided by the contractor without any extra costto height upto 25 mtr. (iii) If same capacity is not available next higher capacity shall be provided by the contractor without any extra cost. |
| 201 | M&Lfor water level indicator made out of aluminiumchannel of size 75mm (for lugsi and aluminium plain sheet of 1.25mm thick) fixed on a aluminium channel by suitable size of nuts, bolts and washers including two coats of painting (white and water proof) and marking the water level in \"feet\" with red colour paint including necessary earth work and PCC foundation for fixing of aluminium channel including taking down old indicator, complete all as specified and directed by Engineer in Charge. |
| 202 | S&F of a sign board (for showing location with SWT numbers) overall dimensions 450 mm (width) X 300 mm (height). The sign board face shall be fabricated from 1.0 mm thick mild steel (MS) plain sheet. The board shall be complete with an all-around frame constructed from rolled mild steel sections 50mmx50mmx5mm, The sign board shall be supported by a vertical tubular mild steel (MS) section, 50 mm x 50 mm x 5 mm, extending to a total height such that the bottom of the sign board is 450 mm above finished ground level. The vertical support pole shall be embedded 150 mm into the ground within a concrete foundation of size 150mm x150mmx200mm of Nominal Mix Concrete Type B-0 (1:2:4 ), using 12.50 mm graded aggregate including all necessary excavation for the pole foundation and the removal of surplus excavated soil from the site. The entire exposed metalwork of the sign board, frame and support pole shall receive one coat of appropriate metal primer followed by two coats of synthetic enamel paint, complete all as specified and directed by Engineer in Charge. |
| 203 | M&L for alum mixer chamber of size 1.32x1.07x2.13 mtrs, 1.24x1.05x2.13mtrs, 0.70x1.09x2.13mtrs and 0.70x1.05x2.13mtrs cleaning and grary greasing, repair/ overhauling/ servicing, complete all as specified and directed by Engineer in Charge. |
| 204 | Taking out and cutting of grass, bushes, hedges including small trees 2 mtr length with roots etc. any location sump/ overhead/other E/M installation reservoir including wiring/ scrapping the surface of walls and bottom of the tank by brush for the removal of salt deposit/ fungus grass/ water born green/ bushes and any other vegetation pto complete satisfaction of Engineer-in-Charge and removing the same outside MoD/AF land, complete all as specified and directed by Engineer in Charge. |
| 205 | Dismantling of existing3 phase centrifugal monoblock pump set of capacity upto 5 HP after disconnecting water supply lines/ electrical connections and stripping complete for replacement of unserviceable parts/ re-winding, including re-assembling the same, greasing, oiling, re-connecting the water supply lines/ electrical connections, testing and commissioning for trouble free operation including cost of consumables, complete all as specified and directed by Engineer in Charge. Note:-(i) Re-winding of motor wherever required shall be measured and paid separately under relevant items of this Schedule.(ii) The spares parts given below wherever required for replacement shall be measured and paid separately under relevant items of this Schedule. (For Alum mixer chamber Motor) |
| 206 | Cast iron impeller |
| 207 | Bearing suitable for existing submersible pump |
| 208 | Bush |
| 209 | Water seal |
| 210 | Motor fan blade |
| 211 | MS shaft key |
| 212 | Impeller guide bushing |
| 213 | Bronze impeller |
| 214 | CI casing |
| 215 | Thrust bearing |
| 216 | S&F full Bore Electromagnetic flow meter Transmitter : Power Supply 230 VAC, 4-20 Ma output, 08 digits display with resettable totalizer, LED backlight with LCD display, SS tag plate, IP-65 enclosure, Accuracy 0.55, Remote type display along with charges of remote, suitable for 300mm pipes, complete all as specified and directed by Engineer in Charge. |
| 217 | M&L Chemical filled bottle with Chlorine test kit (ISI Marked) with coloured sample complete with all testing fitments and OT solution in Rexene finished bos, complete all as specified and directed by Engineer in Charge. |
| 218 | Supply of OT solution in Rexene finished for testing of chlorine content in swimming pool, complete all as specified and directed by Engineer in Charge. |
| 219 | M&L for rewinding of pump motor 415 volt,03 phase, 05 HP motor after disconnecting electric cable and earth lead, delivery pipes, shifting to work shop, dismantling the motor assembly and removing the burnt out copper winding of starter and cleaning the starter slots and core assembly, rewinding to stator and rotor winding with suitable gauge super enamelled copper wire with insulating papers and insulation cloths, varnishing the winding and baking heating for achieving thje required insulation resistance, re- assembling the motor and testing complete incl transporting back to site and fixing motor to its original place, reconnecting electric cable and earth leads etc testing and commissioning, complete all as specified and directed by Engineer in Charge. |
| 220 | M&L for disconnected/dismantling of float valve assembly from raw water tank 1,2,3 & 4 complete with CI bend 300mm and along with old rusted float cylinder etc, supply and fixing new float valve assembly comprising of the following as specified:-(i) Cylinder of size 450 mm dia and 1.2 meter long made out 2mm thick PBI sheet, cylinder made with water proof welding joints including testing of water leakage upto entire satisfaction of Engr-in-Charge and making the existing arrangement as pr manufacture\"s instruction.(ii) Float of size 0.65 metre dia at bigger end and 0.25 meter dia atsmaller end, 3.5 metre long made out of 2mm thick PBI sheet, float made with water proof welding joints including testing the water leakage upto entire satisfaction of Engr-in-charge. |
| 221 | Supply and fillCalcium based Granular Chlorination Chemical(60-70%) Chlorine Granuals in fine form of good qualitySize 2-4 Mesh Appearance : White Granuals Effective Chlorine : 60-70% in liquid form and pore in chlorination plant in to the pump house Aquafit pirichlor by sree Royal seema, Purichlor all as directed in fine form of good quality, complete all as specified and directed by Engineer in Charge. Note:- The rate shall be included for labour and material for making liquid form and pouring to dosing plant till completion of contract. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail