| Sl. No. | Item Description |
| 1 | 34W/CAP-02/2025-26:- Addn/Altn to Bldg No P-944. (B/R Portion) |
| 2 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engineer in Charge. |
| 3 | M&L for roughening of roof surfaces by wire brushing and cleaning top surfaces of cement concrete, roof slab, including flashing and junction of parapets etc and brushing neat cement slurry with 3 kg of cement per sqm, complete all as specified and directed by Engineer in Charge. |
| 4 | M&L for cement concrete Type B1, 1:2:4 (using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed by Engineer in Charge. |
| 5 | Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed by Engineer in Charge. |
| 6 | M&L for 15mm thick Screed bed or bedding layer in cement mortar 1:3, laid on roof/parapet wall, mixed with water proofing compound when concrete is green, @ 200ml per 50 kg of cement or as per manufacturer instructionscomplete all as specified and directed.Note -Water proofing compound shall be measured and paid separately. |
| 7 | Supply only liquid water proofing compound, ISI marked, complete all as specified and directed by Engineer in Charge. |
| 8 | M&L for UV stable single component fibre reinforced elastomeric liquid applied waterproofing membrane having solid content of 55% formulated wih PU hybrid polymers and reinforcing acrylic fibres and having sun reflectivity Index (SRI) of 106. The application of the material should be done in two coats (10 to 12 hrs gap between each coat) on the substrate, applying first self priming coat at ratio of damp proof ultra and water 3:1 then 2 undiluted coat of damp proof ultra obtaining coverage @1 ltr/10 sqft in three coats. The vital physical and chemical parameters shall be as under. Min elongation at break of 350%, crack bridging ability of 2.5 mm @650 microns thickness, resists positive hydrostatic pressure of up to 10 bars. The material shall be applied with brush or roller, complete in all respect as per the direction of Engr-in charge/consultant. Also, proper surface preparation along with coving at corners is must, complete all as specified and directed by Engineer in Charge.Note:-(i) The work shall be executed by the authorized applicator of the manufacturer only. (ii) The authorized applicator of manufacturer shall be approved by GE. (iii) The color of finish shall be decided by the GE. |
| 9 | M&L for brick work built in CM (1:6) straight or curved on plan exceeding 6 metre mean radius using sub class ‘B’ bricks (Old size bricks), complete all as specified and directed by Engineer in Charge. |
| 10 | M&L for 100 mm thick Cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base to flooring, complete all as specified and directed by Engineer in Charge. |
| 11 | M&L for Plain Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in bands, coping, bed plate etc including weathering slightly chamfered or rounded angles including necessary form work, if any, and finishing exposed surfaces even and smooth using extra cement, complete all as specified and directed by Engineer in Charge. |
| 12 | M&L for 75 mm thick Plain Cement Concrete, 1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protectionfinishing cement concrete surface even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge. |
| 13 | M&L for Granite stone slab (of any type) 18 to 20mm thick machine cut, work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and tabil top for fixing wash basin and flooringbedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types light shade over 15mm thick screed bed in CM 1:6, complete all as specified and directed by Engineer in Charge. |
| 14 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified and directed by Engineer in Charge. |
| 15 | M&L for Machine cut kota stone slab flooring 18-20mm thick over and including cement screed bed or bedding 15mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed by Engineer in Charge. |
| 16 | M&L for mirror polishing and rubbing on old existing kota stone slabeflooring, skirting etc, complete all as specified and directed by Engineer in Charge. |
| 17 | M&L for machine pressed precast concrete coloured interlocking paver blockwith grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade laid over and including 25mm thick sand cushion, complete all as specified and directed by Engineer in Charge. |
| 18 | M&L for Precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab for shelves and similar articles with plain faces including necessary formwork. set in CM 1:4, complete all as specified and directed by Engineer in Charge. |
| 19 | M&L for TMT bars 10 mm dia, and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S or Fe-410-O, complete all as specified and directed by Engineer in Charge. |
| 20 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and directed by Engineer in Charge.Note:- All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations. |
| 21 | M&L for Non Skid ceramic coloured tiles of7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors etc laid over and including 15mm thick screed bed or bedding layer of CM (1:4), set & jointed in neat cement slurry & pointed in coloured cement to match, complete all as specified and directed by Engineer in Charge. |
| 22 | M&L for Vitrifiedtiles Light shade (Double charged / ultra charged) 8 to 10 mm thick (square/ rectangular) polished , area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match over including screed bed or bedding layer of mortar (1:4) 15 mm thick, complete all as specified and directed by Engineer in Charge. |
| 23 | M&L for Vitrifiedtiles Light shade (Double charged/ ultra charged) 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, as in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including rendering 10 mm thick CM 1:4, complete all as specified and directed by Engineer in Charge. |
| 24 | M&L for DesignerGlazed coloured ceramic tiles in vertical surface (dado/skirting) 7mm thick of size 450x300mm set and jointed in neat cement slurry and pointed in colour cement to match includingrendering 10 mm thick CM 1:4, complete all as specified and directed by Engineer in Charge. |
| 25 | M&L for Boring holes through glazed tile lining for pipes, etc n exc 50mm dia and making good, complete all as specified and directed by Engineer in Charge. |
| 26 | Fixing only in repair resecuring of Anodised aluminium snap gridof size 605X 605 mm frame work for false ceiling part portion incl necessary fixing arrangements complete levelled with existing ceiling level, complete all as specified and directed by Engineer in Charge. |
| 27 | Fixing only in repair 12 mm thick perforated particle board/ tiles for insulation and acoustic purpose, 600 X 600 MM size fixed with staples on snap grid as in ceiling, complete all as specified and directed by Engineer in Charge. |
| 28 | Demolition wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets, complete all as specified and directed by Engineer in Charge. |
| 29 | M&Lforsuspended false ceiling system using chicago metallic (E grid) exposed suspended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick (thickness comprising of GI/0.35+ PPPCGS/ 0.3mm & weight of angle0.70 kg for 3050mm length) with and including 4mm thick HPSC (High pressure steam cured) pre-primed , self embossed. textured designer board, water resistant termite resistant, fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 3- 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip) hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture, complete all as specified and directed by Engineer in Charge. |
| 30 | S&F of powder coated aluminium snap grid of size 605 x 605mm frame work for false ceiling incl 2mm dia GI wire for hangers where ever reqd, complete all as specified and directed by Engineer in Charge. |
| 31 | S&F Perforated particle board/ tiles 12mm th for insula-tion and acoustic purposes, 60x60 cm in size, fixed with nails to timber frameworkorwith staples on snap grid, complete all as specified and directed by Engineer in Charge. |
| 32 | Taking down Chowkhats or frames of any descriptionexc 1.5 sqm and not exc 4.0 Sqm each(without taking off shutters from the frames), complete all as specified and directed by Engineer in Charge. |
| 33 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm (single rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length completeincluding PCC Type B1 1:2:4 (using 20 mm graded granite stone aggregate) for repair of hold fasts and similar works as per specified drawings, complete all as specified and directed by Engineer in Charge. |
| 34 | S&F Factory made solid PVC Moulded Door shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, S&F in frame at site as per specification & drawing, complete all as specified and directed by Engineer in Charge. |
| 35 | S&F Butt hinges 100mm size, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed by Engineer in Charge. |
| 36 | S&F Aluminium, anodised, barrel tower bolts 150mm long of extruded section, complete all as specified and directed by Engineer in Charge. |
| 37 | S&F Aluminium handles 150mm size, cast type, anodised, complete all as specified and directed by Engineer in Charge. |
| 38 | S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed by Engineer in Charge. |
| 39 | Taking down old PVC wall panelling including fillets and mouldings and similar works of any description, complete all as specified and directed by Engineer in Charge. |
| 40 | M&Lfor PVC SHEET WALL PANELLING of solid thickness 5 mm consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm thick prelam PVC sheet. The panel & strips shall be of 600 kg / cbm density manufactured by an ISO-9000 certified company. The strips should two PVC strips. The PVC strip shall be fixed to the wall using 65mm long M.S screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a U Channel at top, bottom and side edges andstrips of 5mm thick PVC sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement and colour approved by GE, complete all as specified and directed by Engineer in Charge.Note- Including all necessary fittings and scaffolding for heighted site. |
| 41 | M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors, ladders,framed balusters, walk ways, railings; framework of water tanks and framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. Similar work conforming to Fe.290. Gde-E-165, complete all as specified and directed by Engineer in Charge. |
| 42 | M&L for Preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide paint exposed to view surfaces, complete all as specified and directed by Engineer in Charge. |
| 43 | S&F Plain Aluminium sheeting Alloy 31000 H4 in stepped flashing (measured as the minimum rectangle from which the pieces can be cut)0.56mm thickfixed with self tapping screws fixed towall wherever required, complete all as specified and directed by Engineer in Charge. |
| 44 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, including dismantling of old partition of any type and size wherever existing, complete all as specified and directed by Engineer in Charge. |
| 45 | S&F of powder coated aluminium door shutters, aluminium sections weighing .55 kg/M including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, 3 Nos hinges, 2 Nos tower bolts, aluminium snap beading screws etc, complete all as specified and directed by Engineer in Charge. |
| 46 | Supply only 12 mm thick both sides prelaminated Particle board, interior grade, fixed with screws to frame work in cup board shutters, partitions, shelves etc, complete all as specified and directed by Engineer in Charge.Note:- Rate for fixing deemed to be included with item No 1.43 & 1.44. |
| 47 | Supply only 5.5 mm thick tinted glass ordinary quality and glazing with oil putty or with wooden/ aluminium shutter (supplied along with shutter)exc 0.50 sqm each, complete all as specified and directed by Engineer in Charge.Note:- Rate for fixing deemed to be included with item No 1.43 & 1.44. |
| 48 | S&F Solar control film 25 micron reflective type sticked to glass panes exc 1.50 sqm in area as per instructions of manufacturers, complete all as specified and directed by Engineer in Charge. |
| 49 | S&F factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Windowprofile with hollow section with mitlti chamber, frame(60mm x 58mm), sash (60mm x 78mm). T profile (Onevertical length in between two shutters) (60mm x74mm). Glazing bead (35mm x 20mm) will be miteredcut and fusion welded at all corners, includingdrilling holes for fixing hardware and drainage of water etc, making arrangement for fixing of hardware.EPDM gasket 1.2 + -0.2mm thick galvanized steelFrame (28mm x 21.5mm), sash (31mm x 27mm), Tprofile (27mm x 17mm) to be inserted in requiredprofile, frame will be fixed to the wall wilh 8mm x100mm long fasteners, Hardware casement doorhandle made of zinc alloyed (white powder coated),Corner striker, Secondary Strikers, Cylinder, Doortransmission gear made of mild sleel with multi pointlocking system with strikes, 3D Hinges of zinc alloyed including door cill (white powder coated) and 8mm to 10mm thick glazing withselected quality glass, complete all as specified and directed by Engineer in Charge.Note:- The unit rate quoted by contractor excludescost of glass and includes all other connectedaccessories. Net opening will be measured forpayment purpose. |
| 50 | S&F factory made uPVC white colour of extruded profile wilh wall thickness of 2.3mm (+ -0.2mm) Windowprofile with hollow section with mitlti chamber, frame(60mm x 58mm), sash (60mm x 78mm). T profile (Onevertical length in between two shutters) (60mm x74mm). Glazing bead (35mm x 20mm) will be miteredcut and fusion welded at all corners, includingdrilling holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware,EPDM gasket 1.2 + -0.2mm thick galvanized steelFrame (28mm x 21.5mm), sash (31mm x 27mm), Tprofile (27mm x 17mm) to be inserted in requiredprofile, frame will be fixed to the wall wilh 8mm x100mm long fasteners and 8mm to 10mm thick glazing withselected quality glass, complete all as specified and directed by Engineer in Charge.Note: The unit rate quoted by contractor excludescost of glass and includes all other connectedaccessories, Net opening will be measured forpayment purpose, complete all as specified and directed by Engineer in Charge. |
| 51 | S&F toughned glass 10mm th as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified and directed by Engineer in Charge. |
| 52 | S&F curtain rod, chromium plated alloy with fixing brackets, ad decorative dove on each side etc, complete all as specified and directed by Engineer in Charge. |
| 53 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge. |
| 54 | M&L for preparing new plastered surfaces of wall and applying two coats of oil emulsion distemper over one coat of chalk whiting primer over and including 3mm thick wall care putty, complete all as specified and directed by Engineer in Charge. |
| 55 | S&F door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg of aluminium (extruded section body), complete all as specified and directed by Engineer in Charge. |
| 56 | Taking down and refixing of GI door, window joinery area exc 1 sqm not exc 3 sqm after making serviceable including removing of rubber seal, hinges, beadings and fixing new aluminium/rubber beading, hinges and locking arrangement and replacing unserviceable part ie. glass pane floor door stopper, door spring etc, complete all as specified and directed by Engineer in Charge.Note:- Glass pane, floor door stopper and door clouser will be measured and paid separately in respective item of BOQ. |
| 57 | S&F Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor, complete all as specified and directed by Engineer in Charge. |
| 58 | S&F in repair 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer in Charge. |
| 59 | S&F in repair PVC (SWR) 75 mm bends any radius, complete all as specified and directed by Engineer in Charge. Specified. |
| 60 | S&F in repair 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer in Charge. |
| 61 | S&F in repair PVC (SWR) 110 mm bends any radius, complete all as specified and directed by Engineer in Charge. |
| 62 | S&F in repair PVC (SWR) 110 mm vent cowl, complete all as specified and directed by Engineer in Charge. |
| 63 | S&F of 150 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with and including flat iron (40x3mm) for clamps, nut bolts including taking out existing old unsv pipes, complete all as specified and directed by Engineer in Charge. |
| 64 | S&F of 150 mm bore PVC (SWR) bends any radius, complete all as specified and directed by Engineer in Charge. |
| 65 | S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 20mm bore iron pipe and fixed in position, complete all as specified and directed by Engineer in Charge. |
| 66 | S&F in repair 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed by Engineer in Charge. |
| 67 | S&F polyester coloured venetian blind mounted on doors/ windows/vents with aluminium hanging channel with sliding wheel rope including all necessary fittings and fixture and taking down old drapery rod, making good surrounding area, complete all as specified and directed by Engineer in Charge. |
| 68 | S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted & fixed in position including Tank Nipple, 20 mm bore ball brass valve and with union (Two Nos each), fittings including dismantling of old water tanks and removal from site, complete all as specified and directed by Engineer in Charge. |
| 69 | M&L 15 mm dia tubes medium grade galvanised with all fitting and fixed to walls and ceilings or laid in floors including taking down for cleaning and removal to store etc, complete all as specified and directed by Engineer in Charge. |
| 70 | M&L 20 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors including taking down and cleaning for removal to store etc, complete all as specified and directed by Engineer in Charge. |
| 71 | Supply & laying of CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls, complete all as specified and directed by Engineer in Charge. |
| 72 | S&F Vitreous Ware wash down water closet (Pedestal), white (EWC) and fixed in repairs excluding flush pipe and flushing cystrenincluding concrete complete including making good to floor, complete all as specified and directed by Engineer in Charge. |
| 73 | Supply only plastic water closet seat cover white close pattern with flat bottom and cover, complete all as specified and directed by Engineer in Charge.Note : Rate for fixing deamed to be included with item No 1.71 |
| 74 | S&F in repairhealth faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25mtr long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed by Engineer in Charge. |
| 75 | Supply only 10 Litters capacity PVC valve less, symphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC 32 mm dia, complete all as specified and directed by Engineer in Charge.Note : Rate for fixing deemed to be included with item No 1.71. |
| 76 | S&FVitreous China Urinal, Half stall type, white (including west coupling & waste pipe), complete all as specified and directed by Engineer in Charge. |
| 77 | S&F in repairs 15mm dia Pillar taps fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and flu-nuts screwed for iron pipe, complete all as specified and directed by Engineer in Charge. |
| 78 | S&F in repairs 15 mm bore Stop Valve fancy type chromium plated, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed in repairs, complete all as specified and directed by Engineer in Charge. |
| 79 | S&F in repairs 15 mm bore Fancy type Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed by Engineer in Charge. |
| 80 | S&FPVC connections 15 mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engineer in Charge. |
| 81 | S&F Aluminium anodisedTubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed by Engineer in Charge. |
| 82 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long, complete all as specified and directed by Engineer in Charge. |
| 83 | S&F fancy type looking mirror of size 600mmx450mm selected quality ( as approved by Engr-in-charge)5.5 mm thick glass, mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with CP brass screws & cup washers, complete all as specified and directed by Engineer in Charge. |
| 84 | S&F Urinal spreader of PTMT any colour forfixing with 15 mm dia pipe. (Minimum weight 60gms), complete all as specified and directed by Engineer in Charge. |
| 85 | S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including waste coupling and waste pipe, complete all as specified and directed by Engineer in Charge. |
| 86 | M&L for Cutting existing steel tubing of 20mm dia for alterations or additions (Each cut measured), complete all as specified and directed by Engineer in Charge. |
| 87 | Cuttingintoexistingbrick/ RCC wall for connecting new drains pipe up to 150mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified and directed by Engineer in Charge. |
| 88 | 34W/CAP-02/2025-26:- Addn/Altn to Bldg No P-944.(E/M Portion internal services) |
| 89 | M&L for point wiring complete with ISI marked1.5 SqmmPVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc,concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etcincluding PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed by Engineer in Charge for following Items:-One light point controlled by one, one way switch |
| 90 | All as per srl Item No. 2.01 here-in-before but for One ceiling fan/exhaust fan point controlled by one way switch 6 Amps. |
| 91 | All as per srl Item No. 2.01 here-in-before but for Switch Socket outlet 2/3 pins 6 Ampson independent board. |
| 92 | All as per srl Item No. 2.01 here-in-before but for Switch Socket outlet 2/3 pins 6 Amps on same board. |
| 93 | M&L for point wiring complete with ISI marked 4 SqmmPVC insulated unsheathed multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc,concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etcincluding PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 4 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly for 15 Amps switch socket, complete all as specified and directed by Engineer in Charge. |
| 94 | S&Fmodular fan regulator 120watt 240 V AC two module type, complete all as specified and directed by Engineer in Charge. |
| 95 | S&Fceiling rose, 3 terminals /PVC/Polycarbonate, isolated body, complete all as specified and directed by Engineer in Charge. |
| 96 | S&Fmodular Socket 6A-2/3 pin combined two module type, complete all as specified and directed by Engineer in Charge. |
| 97 | S&Fmodular Socket 6A/16A-2/3 pin combined two module type, complete all as specified and directed by Engineer in Charge. |
| 98 | S&Fmodular 1 way 6Amp switch 1 module, complete all as specified and directed by Engineer in Charge. |
| 99 | S&F1 way 15 Amp switch 1 module, complete all as specified and directed by Engineer in Charge. |
| 100 | S&F LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed by Engineer in Charge. |
| 101 | S&F led luminaire 600 mm x 600 mm 35/36 watt, 220V AC recessed/Surface mounted type with high efficiency PMMA diffuser soft glare light with LED efficacy of 120 lm/watt electronic driver, suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size, complete all as specified and directed by Engineer in Charge. |
| 102 | M&L for sub main wiring with 2 runs of 4 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof,floors etc including one run of 4.0 Sqmm PVC copper conductor as earth continuity wire includingtaking downunserviceable sub main wiring including conduit, complete all as specified and directed by Engineer in Charge.Note:- 2 Runs of 2.5 sqmm cable 1 run of 2.5 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. |
| 103 | All as per srl item No 2.14 here-in-before but with 3 runs 6 sqmmincluding 1 run of 6 sqmm PVC copper conductor FRLS cable as earth continuity wire in not less than 25mm dia PVC conduit, complete all as specified and directed by Engineer in Charge.Note:- 4 Runs of 6 sqmm cable 1 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit for the purpose of payment. |
| 104 | S&F MCB DB 8 way SPN (double door)sheet metal enclosure factory made suitable for MCB DB\"s 240 voltswith 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site, complete all as specified and directed by Engineer in Charge. |
| 105 | S&F MCB TPN DB 04 way(double door)sheet metal enclosure factory made suitable for MCB TPN incomer and MCBs as outgoingwith 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits, complete all as specified and directed by Engineer in Charge. |
| 106 | S&FMCB single pole 6-32 Amps working on 240 volts, 50 HZ AC, 10 KA \"C\" curve, complete all as specified and directed by Engineer in Charge. |
| 107 | S&F MCB SPN 32-40 Amps working on 240 volts, 50 HZ AC, 10 KA \"C\" curve, complete all as specified and directed by Engineer in Charge. |
| 108 | M&L for Sifting of MCB 4 pole operating on 415V, AC supply of capacity 63-100 Amps, 10 KA \"C\" curve including taking down old existing un serviceable isolators, complete all as specified and directed by Engineer in Charge. |
| 109 | S&F MCCB 100 Amps, 3/4 pole, 16KA, 415 Volts, 50 HZ, Icu=100% Ics thermal magnetic fixed olc and short circuit rating including necessary fixing arrangement for fixing of MCCB to the existing panel, connecting cable connectionsMCCB, complete all as specified and directed by Engineer in Charge. |
| 110 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed by Engineer in Charge. |
| 111 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc, complete all as specified and directed by Engineer in Charge. |
| 112 | S&F LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed by Engineer in Charge. |
| 113 | S&F GI tubing 15mm dia light grade for protection of GI earth wire, complete all as specified and directed by Engineer in Charge. |
| 114 | 34W/CAP-02/2025-26:- Addn/Altn to Bldg No P-944.(E/M Portion Air Conditioning) |
| 115 | Supply and install hi wall split units indoor/ outdoor complete with cordless remote control unit and withi n built Heating and Cooling arrangement and Digital Inverter twin rotary type, 5 star rating of 1.5 TR capacity, complete all as specified and directed by Engineer in Charge. |
| 116 | M&L for sub main wiring with 2 runs of 4 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof,floors etc including one run of 4.0 Sqmm PVC copper conductor as earth continuity wire includingtaking downunserviceable sub main wiring including conduit from MCB SPN to AC box, complete all as specified and directed by Engineer in Charge.Note:- 2 Runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. |
| 117 | S&Fmetallic AC earth plug and socket with sheet metal enclosure with MCB SP 20Ato 32 A, complete all as specified and directed by Engineer in Charge. |
| 118 | 34W/MR-02/2025-26:- Addn/Altn to Hydraulic Lab.(B/R Portion) |
| 119 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and getting out in soft/loose soil, complete all as specified and directed by Engineer in Charge. |
| 120 | M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling mass concrete and bed ofdrains, complete all as specified and directed by Engineer in Charge. |
| 121 | M&L brick work with sub class ‘B’ bricks, old size straight or curved on planexceeding 6.00 metre mean radius, built in cement mortar (1:4) including corbelling and arches, complete all as specified and directed by Engineer in Charge. |
| 122 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as specified and directed by Engineer in Charge. |
| 123 | Cutting out bricks built in new brick wall with CM 1:4, forming toothing for, and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only), complete all as specified and directed by Engineer in Charge. |
| 124 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ loose soils, complete all as specified and directed by Engineer in Charge. |
| 125 | Removing excavated materialexc 250 mtr n exc 500 mtr and depositingwhere directed at a level not exc 1.5 mtr above the starting point in soils, complete all as specified and directed by Engineer in Charge. |
| 126 | M&L cement concrete nominal mix design type B-1, 1:2:4 (using 20 mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer in Charge. |
| 127 | M&L for TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S 0r Fe-410-O, complete all as specified and directed by Engineer in Charge. |
| 128 | M&L for TMT bars 5 mm dia., and over upto cut to length, bent to shape required, including 10 mm stirrups securing with clips quality confirming to Fe-410-S 0r Fe-410-O, complete all as specified and directed by Engineer in Charge. |
| 129 | M&L for Fair finish form work to sides and soffits of floor or lintel beams, beam hunching, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. also splays between floors and beams etc, complete all as specified and directed by Engineer in Charge. |
| 130 | M&L for Formwork to edges of concrete flats rough finish, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 5.0 cm but n.exc 10.0 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed by Engineer in Charge. |
| 131 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) remaining serviceable tiles to stores and rubbish off the premises, complete all as specified and directed by Engineer in Charge. |
| 132 | M&L for Vitrified Ceramic tiles light shed 10 mm thick (square/ rectangular) polished, area of each tilesn exc 0.36 sqmin floors etc. set and jointed in neat cement slurry and pointed in whiteor coloured cement to match laid over and including 10 mm thick cement screed bedding layer in cement mortar 1:6, complete all as specified and directed by Engineer in Charge. |
| 133 | M&L for Glazed ceramic coloured tiles first quality of size 450x300 x 6 to 7 mm thick on vertical surface such as skirting/dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile with & including rendering 10 mm thick cement plasterin cement mortar 1:4 finished rough to fix tiles, complete all as specified and directed by Engineer in Charge. |
| 134 | M&L for AtrificialGranite slab ( red/white/green coloured) of 15-20 mm thick machine cut as approved, bedded and jointed with grey cement slurry/ bonding agent and pointed with coloured admixture of pigment to match the shade of artificial granite stone slab of red/ white/ green in colour as approved including 15mm thick screed bed to floor finishes in cm 1:4, complete all as specified and directed by Engineer in Charge. |
| 135 | M&L for Plain Cement Concrete, 1:2:4, typeB-1(using 20 mm graded stone aggregate) as in cills, PCC blocks, coping, seismic and other similar bands, plinth bend, etc including weathering slightly rounded or chamfered angles and throuting, including necessary form work etc, complete all as specified and directed by Engineer in Charge. |
| 136 | M&L for 24 guage chicken wire mesh for plastering work at joints of wall & beam Rcc etc of10 mm to 13 mm opening dia size, fix with nails, screws or supporting arrangement, complete all as specified and directed by Engineer in Charge. |
| 137 | Taking down cement plaster on brick/ stone masonryincluding raking out joints, hacking for scrubbing down with water etc, complete all as specified and directed by Engineer in Charge. |
| 138 | M&L rendering 10 mm thick in CM 1:6 on concrete/brick wall surfaces finished surface even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge. |
| 139 | M&L rendering 5 mm thick in CM 1:3 on concrete surfaces finished surface even and smooth without using extra cement as in ceiling surfaces, complete all as specified and directed by Engineer in Charge. |
| 140 | M&L for preparation of newly plastered surface of ceiling including cornices pilasters etc.and applying three coat of white wash on ceiling, complete all as specified and directed by Engineer in Charge. |
| 141 | M&L for applying Twocoats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over brickwall of new and old surfaces, complete all as specified and directed by Engineer in Charge. |
| 142 | M&L for Providing and applying plaster of paris putty of 2 mm thickness in two layers over plastered surface to prepare the surface even and smooth, complete all as specified and directed by Engineer in Charge. |
| 143 | Demolition of brick work or stone/bouldermasonry includingall quoins, arches, pillars, etc, built in cement mortar, complete all as specified and directed by Engineer in Charge. |
| 144 | M&L for 100 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm gradedstone aggregate) in sub base of flooring/ hard standing, complete all as specified and directed by Engineer in Charge. |
| 145 | M&L for 75 mm thick Plain Cement Concrete, 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection finished surface even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge. |
| 146 | Taking down chowkhats or frame with shutter (without taking off shutter from the frame),n.exc 1.5 Sqmeach, complete all as specified and directed by Engineer in Charge. |
| 147 | Taking down chowkhats or frame with shutter (without taking off shutter from the frame),exc 1.5 Sqm n exc 4.0 sqm each, complete all as specified and directed by Engineer in Charge. |
| 148 | M&L powder coated Anodised aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and directed by Engineer in Charge. |
| 149 | S&F in repairs aluminium powder coated window/door grills, mesh size 50mm x50mm thickness 3.8mm, complete all as specified and directed by Engineer in Charge. |
| 150 | S&F of powder coated anodised aluminium door shutters, aluminium sections weighing .55 kg/M including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, 3 Nos hinges, 2 Nos tower bolts,1 nos mortise lock anodised aluminium snap beading screws etc, complete all as specified and directed by Engineer in Charge. |
| 151 | S&F anodised aluminium window and ventilator shutters, side hung type with out sash bars, aluminium section weighing 0.55kg/m incl necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21 100 mm long (2 No) suitable handle (1 No) with powder coating of any colour (thickness of powder coating not less than 50 micron), complete all as specified and directed by Engineer in Charge. |
| 152 | M&L for 12 mm thick both sides prelaminated Particle board, exterior grade, fixed with screws to frame work in cup board shutters, partitions, shelves etc, complete all as specified and directed by Engineer in Charge. |
| 153 | S&F 5.5 mm thick tinted glass ordinary quality and glazing with fixing arrangement as specified or directed in aluminium shutter or upvc shutters(supplied along with shutter)exc 0.50 sqm each, complete all as specified and directed by Engineer in Charge. |
| 154 | Dismantling of walll and ceiling boards/sheet (fibre, pulp, wood board, insulation, floor PVC sheet etc) or insulation boards/ slabs/ blankets,PVC tiles any thickness including cover fillets, complete all as specified and directed by Engineer in Charge. |
| 155 | M&Lforsuspended false ceiling system using chicago metallic (E grid) exposed suspended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/ 0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick (thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle0.70 kg for 3050mm length) with and including 4mm thick HPSC (High pressure steam cured) pre-primed, self embossed. textured designer board, water resistant termite resistant, fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 3- 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips (Wt-0.007 Kg/clip) hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture, complete all as specified and directed by Engineer in Charge. |
| 156 | S&F Rotational moulded polythene water storage tank double layer, ISI Marked of capacity 500 litre cylindrical vertical with closed top hoisted in position complete including dismantling of existing tank, complete all as specified and directed by Engineer in Charge. |
| 157 | S&F in repair 20 mm boreBall brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule, complete all as specified and directed by Engineer in Charge. |
| 158 | S&F galvanised steel water tubes \"medium grade\", 15 mm bore, with and including all GI fittings. fixed to walls, ceiling or laid in floors, complete all as specified and directed by Engineer in Charge. |
| 159 | S&F galvanised steel water tubes \"medium grade\", 20 mm bore, with and including all GI fittings, fixed to walls, ceiling or laid in floors, complete all as specified and directed by Engineer in Charge. |
| 160 | S&F in repairtubular towel rail 600 mm long of brass chromium plated 20 mm dia D type 60 cm long fixed with two plugs (gutties) of 2nd class hard wood embedded in cement mortar 1:3 with MS screws, complete all as specified and directed by Engineer in Charge. |
| 161 | S&F 15 MM Pillar taps, cast copper alloy, with capstan heads fancy type, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and directed by Engineer in Charge. |
| 162 | S&F in repair angle valves /stop valves 15 mm nominal bore, brass, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handles, screwed both ends for iron pipes or for unions, complete all as specified and directed by Engineer in Charge. |
| 163 | S&Fbrass chromium plated grating 125 mm dia circular with centre hole/ without hole of approved make and fixing with cement mortar 1:3 on Nahani trap or floor trap, complete all as specified and directed by Engineer in Charge. |
| 164 | S&F in repair 32 mm dia PVC waste pipe for WHB, complete all as specified and directed by Engineer in Charge. |
| 165 | S&f 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer in Charge. |
| 166 | S&f PVC (SWR) 75 mm bends any radius, complete all as specified and directed by Engineer in Charge. |
| 167 | S&f 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer in Charge. |
| 168 | S&f 110 mm PVC (SWR) \"P’ trap, complete all as specified and directed by Engineer in Charge. |
| 169 | S&f PVC connections 15mm size with PTMT nuts of length 450 mm, complete all as specified and directed by Engineer in Charge. |
| 170 | S&F sinks made of stainless steel 1.0 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed by Engineer in Charge. |
| 171 | 34W/MR-02/2025-26:- Addn/Altn to Hydraulic Lab.(E/M Portion) |
| 172 | Supply and install Automatic boost/buck transformer for low and high voltage correction, equipped with electronic transistor relay suitable for correction on single phase 50 cycles AC supply complete with voltmeter and designed for input voltage 90 to 300V and output voltage stabilized 230V with accuracy of + 5% and of capacity4 KVA wall mounted, complete all as specified and directed by Engineer in Charge. |
| 173 | Supply and installhi wall split units 1.5 TRindoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity, complete all as specified and directed by Engineer in Charge. |
| 174 | Single pole and neutral enclosure with a two pin and earthPlug and socket complete including one single pole MCB 20 - 32 Amp SP MCB B Curve 10 KA, complete all as specified and directed by Engineer in Charge. |
| 175 | S&F drain pipes 25mm dia heavyduty rigid PVC from indoor unit to exit point as per design including accessories clamps fastener etc, complete all as specified and directed by Engineer in Charge. |
| 176 | Supply, install, commissioning and testing of commercial Air curtain unit for prevention of dust and conditionedair losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MSCRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening of size 58\" x 78\" including sensor, complete all as specified and directed by Engineer in Charge. |
| 177 | M&L for concealed point wiring using approved colour codeing as per IS with halogen free flame retardant (HFFR) smoke free non toxic,non corrosive with copper cable 1.5 sqmm confirming to IS: 694 nominal area single core insulated and unsheathed stranded cable 1100 volt grade and including 20 mm dia. ERW stove enamelled concealed conduit heavy duty ISI marked and unsheathed copper conductor 1.5 sqmm area as earth wire as earth continuity conductor, complete all as specified and directed by Engineer in Charge. |
| 178 | S&F LED light fitting 1x8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with threecore flexible copper conductor cable with suitable size, complete all as specified and directed by Engineer in Charge. |
| 179 | S&F Switch flame proof rotarytype with termination box in LM6, 16A, single pole 250V, complete all as specified and directed by Engineer in Charge. |
| 180 | S&F flame proof exhaust fans of size 380 mmsingle phase AC supply complete and fixing arrangement etc complete with all accessories prewired andincluding connecting up with twin core twisted flexible copper cableFRLS of suitable size incl making hole for fixing of exhaust fan of suitable size and making good disturbed surfaces, complete all as specified and directed by Engineer in Charge. |
| 181 | M&L sub main wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site, complete all as specified and directed by Engineer in Charge. Note:- Two runs of 4 sqmm cable along with one run of 4 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length |
| 182 | M&L for sub main wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 6 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distemper, complete all as specified and directed by Engineer in Charge.Note:- Two runs of 6 sqmm cable along with one run of 6 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length. |
| 183 | M&L for point wiring light point / bell point with single core PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) drawn through in existing concealed conduit, fixed on wall, ceiling with GI saddles GI screws, rawal plugs (concealed conduit wiring) with all fittings including Tee, junction boxes and provision of modular metal flush boxof suitable sizemodular white cover plate with frame for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area), complete all as specified and directed by Engineer in Charge.NOTE:- After rewiring cutting chasing portion should be matched with existing finishes of walls.MAKE-1.Havells, 2.polycab, 3.KEI. |
| 184 | All as per item No 5.12 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly. |
| 185 | S&Fmodular white cover plate with frame, 3 module. |
| 186 | S&F Metal Flush boxes 3 module . |
| 187 | M&L modular switch 1 way 6 A, 1 module. . |
| 188 | M&L modular socket, 6A-2/3 pin combined, 2 module. |
| 189 | M&L modular switch16 Amps, 1 module with indicator |
| 190 | M&L modular socket16 Amps, 6 pin, 2 module |
| 191 | S&F sheet metal enclosuresDBDouble door Vertical distribution type,04 way,TPN DB , IP43, 415V & suitable for MCCB TP as incoming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer, complete all as specified and directed by Engineer in Charge. |
| 192 | S&F sheet metal enclosuresDBDouble door type 8 way SPN 240 voltincluding 200 Amps rated bus bar with neutral link complete, complete all as specified and directed by Engineer in Charge. |
| 193 | S&F MCB SP 5 to 32 Amps,240 volts curve \"C\", breaking capacity 10KA,all as specified complete all as specified and directed by Engr-in Charge |
| 194 | S&F MCB SPN32 /40 Amps,240 volts,curve \"C\", breaking capacity 10 KA, complete all as specified and directed by Engineer in Charge. |
| 195 | Supply and install 3 Pole MCCB 100, 50 Hz, 415 V with rupturing capacity 16 KA, complete all as specified and directed by Engineer in Charge. |
| 196 | 34W/MW-10/2025-26:- Provision of Guard Post.(B/R Portion) |
| 197 | Surface excavation n.exc.30 cm deep and averaging 15 cm deep and getting out soft/loose soil, complete all as specified and directed by Engineer in Charge. |
| 198 | Excavation in trenches n.exc 1.5m deep & n.exc 1.5m wide on plan in soft/loose soil and getting out, complete all as specified and directed by Engineer in Charge. |
| 199 | M&L Plain Cement Concrete, 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, complete all as specified and directed by Engineer in Charge. |
| 200 | M&L forBrickwork with subclass `B\" bricks, straight or curved on plan exc 6m mean radius with old size bricks, complete all as specified and directed by Engineer in Charge. |
| 201 | M&L for Hard core of gauge n.exc 63mm of branch stone, and levelled in layers n. exc 15 cm thick watered and rammed to true, complete all as specified and directed by Engineer in Charge. |
| 202 | M&L for 75 mm thickPlain Cement Concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base, complete all as specified and directed by Engineer in Charge. |
| 203 | Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and directed by Engineer in Charge. |
| 204 | Removing excavated material n exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed by Engineer in Charge. |
| 205 | M&L for rendering 10mm thick on any faces of brick wall in cement mortar 1:6 finished even and smooth without using extra cement as in internal surfaces, complete all as specified and directed by Engineer in Charge. |
| 206 | M&L for rendering 10mm thick on fair faces of brick wall in cement mortar 1:4 finished even & fair on external wall, complete all as specified and directed by Engineer in Charge. |
| 207 | M&L for Reinforcement Cement Concrete, 1:2:4 nominal mix type B1 (using 20 mm graded aggregate) inSlabs supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slabs and in shelves, complete all as specified and directed by Engineer in Charge. |
| 208 | S&F of TMTbars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookingends and binding with mild steelwire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed by Engineer in Charge. |
| 209 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping), complete all as specified and directed by Engineer in Charge. |
| 210 | M&L for Machine cut kota stone slab flooring 18-20mm thick over and including cement screed bed or bedding 15mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed by Engineer in Charge. |
| 211 | M&L for Machine cut kota stone slab as in vertical surface such as skirting 18-20mm thick over and including cement 10mm thick rendering in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed by Engineer in Charge. |
| 212 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, including dismantling of old partition of any type and size wherever existing, complete all as specified and directed by Engineer in Charge. |
| 213 | S&F powder coated aluminium window and ventilator shutters, side hung typewithout sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21100mm long (2 no.) suitable handle (1 no.), complete all as specified and directed by Engineer in Charge. |
| 214 | M&L for 4mm thick figured glass, pin head type and glazing with oil putty in square n exc 0.5 sqm in each pane, complete all as specified and directed by Engineer in Charge. |
| 215 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size45 x 70mm (single rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length completeincluding PCC Type B1 1:2:4 (using 20 mm graded granite stone aggregate) for repair of hold fasts and similar works as per specified drawings, complete all as specified and directed by Engineer in Charge.Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 216 | S&F Factory made solid PVC Moulded Door shutter with particle board core,28 to 30mm thick (stiles), with 2, 4 ,or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, S&Fing in frame at site as per specification & drawing, complete all as specified and directed by Engineer in Charge. |
| 217 | S&F Butt hinges100mm size, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed by Engineer in Charge. |
| 218 | S&F Aluminium, anodised, barrel tower bolts 150mm long of extruded section, complete all as specified and directed by Engineer in Charge. |
| 219 | S&F Aluminium handles 150mm size, cast type, anodised, complete all as specified and directed by Engineer in Charge. |
| 220 | S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed by Engineer in Charge. |
| 221 | M&L for preparing new plastered surface of wall/roof concrete surface andapplying Two or more coats of 100% Premium acrylic emulsion paint in Camouflaging pattern by using 4 to 5 Colour shades as per approved pattern having VOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces, complete all as specified and directed by Engineer in Charge. |
| 222 | M&L for Preparing Newly Plastered Surfaces of internal wall and applying two Coats of oil emulsion distemper incl chalk whiting includin 3mm thick wall care putty on wall on plastered surface preparatory to distempering, complete all as specified and directed by Engineer in Charge. |
| 223 | M&L for 75mm thick Plain Cement Concrete, 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection or path finished surface even and fair, complete all as specified and directed by Engineer in Charge. |
| 224 | M&L for 15mm thick Screed bed or bedding layer in cement mortar 1:3, laid on roof, complete all as specified and directed by Engineer in Charge. |
| 225 | M&L for rendering 5 mm thick in CM 1:3 on concrete surfaces finished surface even and smooth without using extra cement as in ceiling surfaces, complete all as specified and directed by Engineer in Charge. |
| 226 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceilling, complete all as specified and directed by Engineer in Charge. |
| 227 | NOTE: BOQ has bifurcated job wise, if bidder quoted different rate for same item at different jobs then lowest quoted rate shall be considered for acceptance for all jobs. |