| 1 | Clering Jungle including uprooting of rank vegetation grass, bush, wood, trees and sapling of grith upto 30cm, measured at height of 1m above groun level & removal of rubbish upto a distance of 50m outside the periphery of area cleared. |
| 2 | Making Layout of building works including making of pucca pillers (Burji) and marking centre line including cost of lime and all T&P (Only plinth area of ground floor to be measured and paid) |
| 3 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 4 | Providing and laying in Cement concrete1:4:8 (1Cement:4 coarse sand :8 gradedbrickaggregate 40mm nominal size) andcuring complete,including cost OF formwork in foundation and floors |
| 5 | M-150 brick work in 1:4 cement and Coarse sand of mortar in foundation and plinth including supply of all material, labour and tools and plants. ect. required for proper completion of work |
| 6 | R.C.C. work with cement approved coarse sand and 2cm (3/4\"\") gauge approved srone grit in the proportion 1:1.5:3 in lighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) excluding supply of reinforcement and its bending but including its fixing and binding the same necessary with 24BWG binding wire and including necessary centering and shuttering etc. and also including supply of materials labour and tools and plants etc. (FOR GRADE BEAM) |
| 7 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 8 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), i/cgrouting the Joints with white cement & matching pigments etc. complete size of tile 600x600mm |
| 9 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size) laid in one layer finished with cement floating coat of neat cement (25 mm thick floor). |
| 10 | 15 mm cement plaster in single coat onbrick wall Bellow plinth 1:4 cement coarse sand |
| 11 | Excavation in foundation of local earth (including royality) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc.complete |
| 12 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 13 | Finishing wall with water proofing cement paint over (snowcem painting) undeorated wall surface over and including white cement priming coat |
| 14 | P/F of 16mm dia Foundation Anchor Bolt 400mm long with nut bolt and washer |
| 15 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded tpe tubes |
| 16 | Providing and fixing of 0.50 mm thick Pre Painted gelvelume roofing sheet for RoofingSupply and Installation of 0.50 mm sheet |
| 17 | Providing and fixing of bottom and top U trak for closing of end joints for cut PUF panels of size of 52mm x 30 mm with 5 mm lipping on both edge. The U track shall be made out of 1 mm thick pre coated GI Sheet. the precoated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of 120 gsm as per IS: 277:1992,5-7 microns epoxy primer on both side of the sheet and polyster top coat 15-18 micron. The PPGI Sheet shall have protective guard film of minimum 25 microns to avoid scratches while transporation. The U track shall be fixedwith suitable PO rivet with wall roof panels and plinth with Expandable fastners with minimum spacing of 450 mm c/c. For panel of sizes of 42 mm x 30 mm with 5 mm lipping on both edges |
| 18 | Providing and fixing PUF insulated contineous sandwich panels for roofs of total thickness not less than 30 mm made out from continue line method. Panel shall have pre coated GI Sheet on both side of Polyurethane foam with external face being corrugated in shape for GI and PU foam both material. The crest height of the panel shall be of 35 mm minimum with 250 mm c/c pitch. the precoated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of 120 gsm as per IS: 277-5-7 microns epoxy primer on both side of the sheet and polyster top coat 15-18 micron. The PPGI Sheet shall have protective guard film of minimum 25 microns to avoid scratches while transporation. The roof panels are laid over a frame work of trusses, columns and purlins fixed using 90mm self drilling bolt with rubber washer including all types of flashings PU foam must be self extinguishing fire retardent type having minimum density of 40 kg/cum (+,-2kg) including 0.25 mm thick craft paper edging on both edges. The panels shall be fixed to the steel frame structure with minimum 5 mm thick self tapping GI screws of required length and nos. etc complete as epr structural design and direction of Engineer-in-charge. PPGI Sheet 0.5 mm thick skin on both sides FOR Doors |
| 19 | S/F of connection bolt for structure |
| 20 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture Painting on new steel surface. Structrue |