| 1 | Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re plastering or re-pointing including disposal of rubbish to the dumping ground with all leads and lifts etc.complete as per direction of the Engineer- in charge. |
| 2 | Demolishing brick work including stacking ofserviceable materials and disposal of unserviceable materials with all lifts and upto a lead of 50m etc. complete as per direction of the Engineer- in-charge: In cement mortar. |
| 3 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sqm and below |
| 5 | Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with:1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 6 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 7 | Centering shuttering including struttings, propping etc.and removal of form work for: Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank |
| 8 | Providing and fixing Galvanized chicken mesh (24 guage, 12 mm size) properly stretched and nailed ensuring equal thickness of plaster at junction of masonry work and concrete members. |
| 9 | 6 mm cement plaster of mix : Cement mortar 1:4 (1 cement : 4 fine sand) |
| 10 | 15 mm cement plaster on the rough side of single or half brick wall of mix: Cement mortar 1:4 (1 cement : 4 fine sand) |
| 11 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal ofrubbish to the dumping ground with all leads and lifts including finishing even and smooth and curing complete as per direction of the Engineer in charge:- With cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 12 | Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in allcolours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge 450 mm X 300 mm in all shades and design |
| 13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to steel windows by welding. |
| 14 | Providing and fixing glazing of approved quality in aluminum doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :- With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm ) |
| 15 | Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. Complete |
| 16 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300x16 mm |
| 17 | Providingandfixingaluminiumworkfordoors, windows, ventilators and partitions withextrudedbuilt up standardtubularsections/ appropriateZsectionsand other sections of approved make conforming to IS:733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass/ Stainless steel screws all complete as per architectural drawing and the direction of Engineer - in-charge.(Glazing and paneling and dash fasteners to be paid for separately) :-. |
| 18 | A. For fixed portion of approved quality:-Powder coated aluminium ( minimum thickness of powder coating of 50 micron ). |
| 19 | B. For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required includingthe cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately ):- Powder coated aluminium ( minimum thickness of powder coating of 50 micron ). |
| 20 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board grade-I, type II conforming to IS : 12823 bonded with phenol formaldehyde synthetic resin, of approved brand and manufacture in panelling fixed in aluminium doors, windows, shutters and partition frames with C.P. brass / stainless steel screws all complete as per architectural drawing and the direction of Engineer-in-charge :- Prelaminated particle board of approved quality with decorative lamination on one side and balancing laminationon other side. |
| 21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 22 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 23 | (I) Short Point |
| 24 | (II) Medium Point |
| 25 | Providing and fixing of 3/6 pin 16/20 amps plug point withmodulartype 16/20ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 26 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.3 X 2.5 sq mm |
| 27 | Supplying and fixing of the following modular accessories including necessary connection etc. as required.20/25 amps single phase motor starter switch (2M):- |
| 28 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:-6 to 32 amps SP MCB:- |
| 29 | Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work , over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]. |
| 30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Two or more coats on new work |