Tender For Provision Of Single Men Barracks Including Cook House For Agniveers At 1 Stc Jabalpur; 2 SCHEDULE A Part-I (Building/Structures) (To be quoted by the Contractor) Building Works mentioned at item no 1(A), Item No 1(B) & Item No 1(C) is in ENGINEERING PROCUREMENT CONSTRUCTION (EPC) Mode. Contractors has to carry out the detailed engineering design of these buildings, procure all the equipments and materials necessary and then construct to deliver a fully functional facility to the MES department. 3 Item No 1 (A): Designing (Structurally & Aesthetically) and construction of block of Single Men BarracksFor Agniveers with precast construction technology (2D) permanent specification for (G+3) Storey RCC Framed Structure all as per design basis report,detailed in scope of work and other documents of the tender complete all specified and directed. 4 Item No 1 (B): Designing (Structurally & Aesthetically) and construction of block ofDining Hall & Anti Room ForAgniveers with precast construction technology (2D) permanent specification forStorey RCC Framed Structure all as per design basis report,detailed in scope of work and other documents of the tender complete all specified and directed. 5 Item No 1 (C): Designing (Structurally & Aesthetically) and construction of block ofCook House For Agniveers with precast construction technology (2D) permanent specification for Storey RCC Framed Structure complete all as per design basis report,detailed in scope of work and other documents of the tender complete all specified and directed. 6 Sch A Part-II (External Electric Supply)Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule A Part-II against the lump sum price inserted by the MES. 7 Sch A Part-III(External Water supply)Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule A Part-III against the lump sum price inserted by the MES. 8 Sch A Part-IV(Road Path Culvert)Lump sum price worked out by the contractor for (Road Path Culvert) as listed in Schedule A Part-IV against the lump sum price inserted by the MES. 9 Sch A Part-V(Sewage Disposal)Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule A Part-V against the lump sum price inserted by the MES. 10 Sch A Part-VI(Area Drainage)Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule A Part-VI against the lump sum price inserted by the MES. 11 Sch A Part-VII(Security Fencing & Gate)Lump sum price worked out by the contractor for (Security Fencing & Gate) as listed in Schedule A Part-VII against the lump sum price inserted by the MES. 12 Sch A Part-VIII(Summer & cooling Applinces)Lump sum price worked out by the contractor for (Summer & cooling Applinces) as listed in Schedule A Part-VIIIagainst the lump sum price inserted by the MES. 13 Sch A Part-IX(Arboriculture)Lump sum price worked out by the contractor for (Arboriculture) as listed in Schedule A Part-IX against the lump sum price inserted by the MES. 14 Sch A Part-X(Fire Fighting System)Lump sum price worked out by the contractor for (Fire Fighting System) as listed in Schedule A Part-X against the lump sum price inserted by the MES. 15 Sch A Part-XI(Lightning Protection System)Lump sum price worked out by the contractor for (Lightning Protection System) as listed in Schedule A Part-XI against the lump sum price inserted by the MES. 16 Sch A Part-XII(Site Clearance)Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule A Part-XII against the lump sum price inserted by the MES. 17 Note for Srl No 2 to 17The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 17by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule 18 Schedule A Part-XIII (Miscellaneous items of works) 19 External Electric Supply 20 Item No 02 : Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 160 KVA (Level-1), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5%, continuous rating of capacity 160 KVA including bushing on HT end & cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. 21 Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.0M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class B bricks, brick masonary shall be 450mm below GL & 550mm above GL, 22 exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transfarmer shall also includes the cost of following accessories/ fittings :- 23 Item No 03 : M& L for cable root indicator MS sheet embossed with LT 1100 Volts Volts UGmade with CI Plate6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm longincluding PCC work 1:2:4 type B1 of size 150x150x150 mm complete allas specified & directed 24 Item No 04 : M& L for cable root indicator MS sheet embossed with HT 11000 Volts UGmade with CI Plate6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm longincluding PCC work 1:2:4 type B1 of size 150x150x150 mm complete allas specified & directed 25 Item No 05 : Supply, installing, testingand commissioningout door type LT Panel of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and external surfaces with powder coating paint in heatprocess of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : - 26 BUSBAR :-(i)600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulatorbus bar support (Square/round) insulators of suitable size and good insulation resistanceINCOMING :- (a)MCCB 4 Pole400 Amps, 36 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No (incoming) 27 (b)Digital Voltmeter 3 PhaseClass-1 50Hz - 01 No. 28 (c)Digital Ammeter3 PhaseClass-1 50Hz - 01 No. 29 (d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set 30 (f) Copper wound with CTR 600/5 - 03 Nos 31 OUT GOING 32 (i) MCCB 4 Pole 250 Amps, 36 KA at 415 volts- 02 No.(SM Bldg) 33 (ii) MCCB 4 Pole 100 Amps 16 KA, 415 volts- 01 Nos (Centralised Cooler) 34 (ii) MCCB 3 Pole 40 Amps 16 KA, 415 volts- 02 Nos (Post top lantern Light & LED bollard light) 35 (iii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set 36 (iv) Auto control time switch, timer control for different 24 hours adjustable type including power contractor of capacity 20 amps complete - 01 Nos (1 x Garden Light) 37 Item No 06 : S & FIntegral decorative LED bollard with IP 65/66 protection suitable for 10 watts LED with necessary elecrical connections with adequate size of Nuts and Bolts including junction box with 6-32 A MCB of size complete as all specified and as directed. 38 Earthing 39 Item No 07 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x 6 mmby means ofnut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - 40 (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. 41 Item No 08 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25 X 4 mmby means ofnut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. 42 Item No 09 : S&F earth continuity conductor or main earth lead of 32 X 6 mm GI strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. 43 Item No 10 : S&F earth continuity conductor or main earth lead of 25 X 3.15 mm aluminium strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. 44 Item No 11 : Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 155 x 210 x 92 mm,having terminals for termination of cable with necessary nuts and bolts, including -02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as directed. 45 Item No 12 : Material and labour for preparation of new steel surfaces of any description over 10 cm width or girthand applying one coats of black bituminous paint complete all as specified and as directed. 46 External Electric Supply (Supply DG Set) 47 Item No 13 : Supply, Installation, Testing and Commissioning of silent Diesel Engine driven generating set not less than 20 KVA or nearest standard size, 415 volts, 3 phase 4 wire, 1500 rpm, 50 Hz power supply with power factor 0.8 couple directly to alternator mounted on a common base platecomplete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design thereby facilitating /easy handling installation & shifting of the equipment at site. 48 The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board (CPCB-IV + Emmission compliant) latest norms/regulation Noise level 75dB(A) at a distance of one meter with fuel tank,battery and standard accessories as recommended by manufacturer, vibration pad, sand cushioning around PCC foundation, tools and spares, as provided by manufacturer all as specified and as directed with the following specifications of :- 49 ENGINE - 3 cylinders, inline, 4 stroke cycle, Water cooled, developing Matching21.45 HP at 1500 RPM under NTP conditions of BS:5514. The engine shall be provided with electrical starting arrangement & shall give the electrical output 20 KVA/ 16 KW at 0.8 power factor, Current 38 Amp 415Volts at the alternator terminalALTERNATOR: single bearing alternator suitable for continuous operation generating 20 KVA at 1500 RPM, 415Volts , 0.8 power factor (lag) suitable for 50 Hz, 3 phase, 4 wiresystem, confirming to BS 5000/ IS 4722. The alternator is brushless type, screen protected, revolving field,self excited alternator confirming ti IS/IEC 60034-1, self regulated through an AVR. The alternator has the following features: a) ± 0.50% voltage regulation (max.) in static conditions 50 (b) IP: 23 protection with insulation class H.(c) Permissible overload of 10% for one hour in 12 hours of operation.(d) 3 phase reconnectable winding with 12 terminal brought out for connection.(e)dedicated winding speecially designed for 1 phase operation (f) double layer lap startor winding (g) PCC foundation complete as per manufacturers design including anti vibration pads, necessary excavation & earth work in soft/loose, sand cushioning, grouting foundation etc. 51 Features, Functions, Protections(a) 16 character x 2 line alphanumeric LCD display with LED backlight(b) Operator interface (c)Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory(d) Provide Alternator data fequency Control includes provision for Service adjustment and calibration of DG control functions(a)Voltage, frequency selection(b)Meter calibration(c)Configurable input and output set up PowerStart operates on 12 V DC batteries Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. 52 Engine Starting – The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency.Controller provide configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal.Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working.EngineProtective Functions includes -Configurable alarm outputEmergency stop: Annunciated whenever an emergency stop signal is received by the control(a).Low Lube oil pressure warning and shutdown(b)High engine water temperature warning/ shutdown(c) Low coolant temp warning 53 (d) Sensor failure indication(e)Low and high battery voltage warning (f) Weak battery warning (g) Fail to start shut down(h) Cranking lockout: Control will not allow the starter to engage or to crank the running engine(j) Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods.Alternator Protective functions includes : (l)High and Low AC voltage shut down(m) Under and over frequency shutdown / warning(n) Loss of sensing voltage input shut down (o) Battery charger alternatorFuel tank: Sub Base Fuel tank of 14 SWG MS sheet of adequate capacity to operate 8 to 12hrs on 100% load.(b) Base Rail: Base Rail with integral fuel tank is provided.Batteries: For electrical control circuit ,12 Volts/88 AHbattery for electrical starting of DG set 54 AMF ELECTRICAL CONTROL PANEL : Inbuilt AMF Panel is manufactured with 14/16 guage fabricated out of 2mm thick CRCA sheet, floor mounting type, powder coated for weather-proof and long lasting finish, totally enclosed,front higed cover,instrument swithches and panel complete alla as specified and required. 55 One set of accessories (As per manufactures instruction) :- 56 (aa)Fuel tank with locking arrangement for 08 hours running on full load 57 (ab)Level indicator on fuel tank 58 (ac)Drain plug 59 (ad)MS class Cpiping , suitable dia and length for fuel inlet from tank to engine as per manufactures instruction. 60 (ae)Fuel strainer and fuel tankwith air vent. 61 (af) Batteries heavy duty 12 Volts 88 AH lead acid type fully charged,indication of high flow charing changed : - 01 Nos 62 (ag)Cable connection from alternator to DG set control panel as directed 63 Tools (As per manufactures instructions):- 64 (aa)D spanners - 01 Set 65 (ab)Ring spanners - 01 Set 66 (ac)Screw diver 5to12 - 01 Set 67 (ad)Cutting plier 9 - 01 No 68 (ae)Hammer 2 LBS - 01 No 69 Base frame arrangements . Theengine and alternator would be coupled by means of specially diesigned flexible coupling and both the units including the radiator would be mounted on a rigidfabricated base to form a compact arrangement. The steel shall be Tisco / SAIL or equivalent make. 70 Soundacoustic enclosure :CPCBapproved sound acoustic enclosure sutable for above genrator set with complete set installed within canopy. 71 Item No 14 : M&L for 100 mm thick PCC 1:2:4 TYPE B1 using 20mm graded stone aggregate as in floor/hard standing. 72 Item No 15 : Earthing complete for various equipments with galvanised steel earth plate electrode600 x 600x 6mm thick directly burried in the ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 m below the ground level, connected to G.I Strip 32 x 6 mm by means of bolts, nuts, chuck nuts and washers of galvanised iron or steel, GI pipe 40mm bore light grade for protection of earthing strip, 73 PCC chamber 1:4:8, type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 12mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge ( 0.63) 8 mesh per linear inch, 50mm thick cover of RCC 1:2:4, type B-1, using 20mm graded stone aggregate reinforced with 8mm TMT bar at 100mm centerto center both ways and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-I and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on completion all as directed.Note:- Unit rate quoted is inclusive of earth lead and protection pipe upto 7.5 metre from earth plate. 74 Item No 16 : S & F earth continuity conductor for main earthing lead 32 X 6 mm strip burried in ground or fix in walls with boltsall as specified and directed by engineer in charge. 75 Summer & cooling Applinces 76 Item No 17 : Supply and fixing ofducted cooler top/down discharge - 03 Nos/Floor nominal air delivery of 25000 CMH ,1.5 KW Motor power,cooling capacity upto 1600 sq ft UV Stablized High Grade Plasticof Tank capacity 70 litres Fan Dia620 mm withHoneycomb pads of thickness 100 mm with 80 % minimum cooling efficiency,with 3 phase starter ,hanger hookand L shaped bracket includingsupply ,Installation ,commissioning and balancingof site fabricated Galvanised Sheet Steel (GSS) ducts conforming to IS: 277. Ductwith 1:3 Ratio of 22G0.7 mm and 24G0.6 mm sheet from machine to ceiling height and ceiling to the alumium grills shouldrectangular shape ducting complete with neoprene rubber gaskets,nitrile rubber acoustic insulation of size 19 mm (inside) ,thermal insulation of size 6 mm (outside ),elbows,splitter damper vanes,hangars,supports.Duct work shall be rigid and straight without kinks.All exposed ducts within the conditioned space shall have slip joints. 77 Flanged joints shall not be used.Powder coated alumium Grill and Volume control damper should be used.Ducts shall be supported independently from the building structure and adequately, to keep the ducts true to shape. 78 The support spacing shall be not more than 2 m.Duct connections to the air-handling unit shall be made by inserting a double canvas sleeve .The steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per square meter (GSM) of Zinc, GI sheets shall be lead free, eco friendly and RoHS compliant. All sheet metal connections, partitions and plenums required for flow of air through the filters, fans etc. shall be at least 1.25 mm thick galvanised steel sheets. 79 Hanger rods shall be of mild steel and of at least 10 mm dia for ducts upto 2250 mm size, and 12 mm dia for larger sizes.All nuts, bolts and washers shall be zinc plated steel. All rivets shall be galvanised or shall be made of magnesium - aluminium alloy. Self tapping screws shall not be used.The fabrication of ducts shall be carried outas per approved drawings and specifications of following sheet thickness complete all as specifed and as directed.Note: (i)The duct work shall be as per IS 655.(ii)The GSS sheets for duct work shall conform to class viii with zinc coating of 120 gm/sq mtr as per ISS-277 all as specified and directed 80 Item No 18 : Supply, installing, testingand commissioningout door type LT Panel of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and external surfaces with powder coating paint in heatprocess of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : - 81 BUSBAR :-(i)150 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulatorbus bar support (Square/round) insulators of suitable size and good insulation resistance 82 INCOMING :- 83 (a)MCCB 4 Pole100 Amps, 25 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No (incoming) 84 (b)Digital Voltmeter 3 PhaseClass-1 50Hz - 01 No. 85 (c)Digital Ammeter3 PhaseClass-1 50Hz - 01 No. 86 (d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set 87 (e) Copper wound with CTR 200/5 - 03 Nos 88 OUT GOING 89 (i) MCB 4 P C Series 32 Amps, 415 volts- 03 Nos 90 (ii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set 91 Item No 19 : Supply, installation, commissioningAuto Clean Kitchen Chimney, Baffle Filters, Touch Control with Motion Sensor 60/90cm 1200 m3/h - Silver (6078 MS AC) and all as specified and directed. 92 Item No 20 : Supply, installation, commissioningrefrigerator, electric driven (single phase), capacity more than 195 Litres upto to 310 Litres.BEE 5 star rated all as specified and directed. 93 Item No 21 : Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA all as specified and directed. 94 Item No 22 : Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at230 V with accuracy of ± 2.5% and of capacity 1 KVA all as specified and directed. 95 Security Fencing & Gate 96 Item No 23 : S&F Concertina Coil of 600 mm dia of Approved Type/Make for laying on Y shape angle fixed on boundry wall etc complete. 97 Arboliculture 98 Item No 24 : Plantation of tree of fruits/Herbal nature and taking care for three year after complition of work including watering providing manure/fertilizer etc complete all as directed. 99 Rain Water Harvesting 100 Item No 25 :M & L for composite rain water harvesting system of 5000 litre capacity include of the following (i) under ground water storage tank of 5000 litre capacity01 No(ii) First flush system 01 No(iii) Gravity Filter01 No(iv) Delivery pipe 25 mm sizeUPVC (SCH- 40) 15 RM(v) Down take pipe 100 mm size UPVC (SCH- 40) 15 Rm 101 SEWAGE 102 Item No 26 : Supplying and laying and jointing for (SN 8) DWCPE 180mm (OD)/ 163 (ID) conforning to IS-16098:2013 part -I with and incl jointing materials complete 103 Item No 27 : M&L RCC Septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab,Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 104 Item No 28 : M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 M x 3.0 M depth complete 105 External Water supply 106 Item No 29 : Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,100 mm (4”) dia and all as directed. 107 Item No 30 : M&L for tapping in existing DI pipe lines 150 mm dia and inserting tee of 150x 100 mm and all as directed. 108 Item No 31 : Construction of brick masonry valve pit of size 1200 mm x 1200mm x 900 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 109 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified. 110 Item No 32 : Supply, installation, testing and commissioningLT , 415 Volt, 4 wire AC 50 Hz, cubical panel (Feeder Pillar Box) factory made, out door, pedestral type, feeder pillar box, hutted roof, weather & vermin proof fabricated of 3.0mm thick MS black sheet, front & back double shutter opening type, spraytwo earth terminal suitable cable glands for all incoming and outgoing cable including grounting of feeder pillar box 60cm above ground level by providing 90 cm long angle iron of size 50 x 50 x 6mm welded on all the fours corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm, complete all as specified and directed by Engr-in-Charge including the following accessories /components. (a) Aluminium bus bar - 200 amps rating - 03 Nos. ( for phases and100 Amps for neutral 01 No insulatedwith proper colour coding phase wise ). Qty -04 (b) IncomingMCCB 4 pole 100 Amp, 415 volt, 16 KA Thermal setting 70% to 100%- 01 No (Incoming) (Qty 02 no.) (c) Outgoing 111 (i)MCB TPN 20 to 63 Amps - 02 Nos (d) Automatic star-Delta starter for borewell as suitable after pump lowering(ii) MCB SPN 6 to 10 Amps - 02 No (e) MPCB for borewell as require and suitable for borewell (f) Require neceesarry wiring/cable (size of cable depnd upon the pump installed in the borewell) for connection of panel to a near by Electric line 112 Item No 33 : M&L for fabrication, transportation, erection & testing forHot compressed molded SMC (sheet molding compound) panel tanks of 12000 galloncapacity , erected at ground level usingsteel structureof of Brand SINTEX, AMITEX, DEVI POLYMERS as per BIS: 14399 Part-I & Part-II. ISI Marked SMC Panel tanks of approved brands. Roof & Base of SMC Panel tanks havingpanels of size 1.00 m x 1.00 m, 1.00 m x 0.5 m . Side Walls of tanks shall be constructed using SMC panels of size 1.00 m x 1.00 m panel as per site requirement or as per OEM standards. One manhole of diameter 600mm lockable lid of hot pressed moulded made out of SMC should be provided on the roof of tank with lockable lid and aluminium ladder above 1mtr height inside & outside the tank for access. Tanks must have vertical iron posts lied firmly with Tie rods. 113 The panel should withstand Hydrostatic pressure of atleast 4 times the working load and should be provided with HDG bolts, nuts, washers, food grade foam gasket, cleats, including PVC pipe support of 110mm dia for the roof of top panels. Tank shall be erected on steel base at site as per manufacurers specifications & design. Provision of holes for inlet and outlet, overflow should be made as per direction of Engineer-in- Charge and including connecting with 9 long thread end Nipple complete all as specified & directed by Engr in Charge. The Tank installation work will be carried out at roof of building/ ground level. 114 Note for SI 33(a) The tanks, panels must be printed with ISI Logo, ISI certification Number, CML Number, BatchNumber etc.(b) Steel work i.e. Channels used for base frame required for proper mounting/ erection of water tank are inclusive in the quoted rates.(c) Non-Toxic PVC foam sealant gasket sealant tape: 3 mm thick with high level of resistance to aging and superior recovery from compression) (d)Fasteners utilized for the panel joints of 8.8 grade Steel HDG Bolts nuts MI2 x40mm.(e))External reinforcement C channel at every 1-meter of steel with anti-corrosive paint and it is tie with top external tie rods. (If tank height is more than 1 meter). 115 (f)Internal roof supports should be of FRP/GRP 5 mm thick hollow square section.(g)Air-vent dia 100mm with mosquito proof mesh insect proof..(j)Aluminum body water level indicator with clear tube type and brass nozzle (For Tank height more than 1 Meter) Internal FRP ladder with wall mounting arrangement inside (For Tank height more than 1 Meter).(h)External GIladder with complete fixing arrangement outside.(J) Complete fixing of Inlet/Outlet/overflow/drainwith suitable colour coding paint should be GI Flange type with 9 long Nipple and pipe of uitable sizes.(k) Panel Thickness 6 mm -10mm.(l) Neccesary Civil foundation and Base Frame.(m))Brick work requiredwith plaster .(n) Frame work of I section and C channel. 116 Item No 34 : Supply and fix pressure sensor switch having ambient operating tem -40 to 65 degree celcius , differential pressure range 0.7 bar to 4 bar , regulation range 0.2 bar to 7.5 bar ISO STANDADARD 228-1 complete all as specified and as directed. 117 Item No 35 : Supply , Install, testing & commissioning of monoblock pumpset, 3 phase, 415 V, 50 Hz, bronze impeller,discharge 27-15 lps @ 12-24 mtr head complete all as specified and as directed. 118 FIRE FIGHTING SYSTEM 119 Item No 36 : Supply and fix pressure sensor switch universal type having ambient operating tem -40 to 65 degree celcius , differential pressure range 0.7 bar to 4 bar , regulation range 0.2 bar to 7.5 bar ISO STANDADARD 228-1 complete all as specified and as directed. 120 Item No 37 : Supply and fix automatic air release valve 50mm dia suitable for domestic water with 50 mm gun metal stop valve complete. 121 Item No 38 : Supply only of fire extinguiser ISI marked CO2 type Fire Extinguisher 4.5 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 138. 122 Item No 39 : Supply only of stored pressure fire extinguiser ISI marked powder type Fire Extinguisher 4 KG capacity suitable for Class A, B, C Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 1A & 13B 123 Item No 40 : Supply only of 03x Fire bucket iron body red colour 10 L capacity for dry sand stored type including mounding stand paitnted with red colourISI MarkedIS : 2546 :2006, complete all as specified and as directed. 124 Item No 41 : Supply , hoisting andfixing pvc three layer water storage tank of capacity 5000 ltr including all fitting arrangement complete all as specified and as directed.(Note: For SM Barrack 1x 5000 ltrs ) 125 Item No 42 : Supply only of Fire Extinguisher Mechanical Foam type ISI Marked Foam (AFFF) type Fire Extinguisher 9 ltrs capacity fitted with Forged Brass squeeze lever discharge valve, conforming to IS : 15683 :2006, complete with initial refill consisting of ISI Marked CO gas cartridge of 60 gms capacity conforming to IS 4947 and ISI Marked AFFF conforming to IS : 4989, suitable for operating between + 50 degree centrigrade , Fire Rating Class - 3A & 34B 126 Lightning protection system 127 Item No 43 : S&F porceliene insulators 15 BMD type T with nut bolts / screws for fixing ofaluminium strips on roof including provn ofPCC of size 10cmX10cmX10cm heightetcto avoid leakage of roof complete as directed. 128 Item No 44 : Earthing complete with galvanised steel earth plate 60×60cm ×3.15mm thick electrode earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32×6mm by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), cast iron frame, funnel with wire mesh,GIwatering pipe of 20 mm bore medium grade and lugs, with and including galvanised iron strip 32×6mm with GI protection pipe of 15 mm medium grade 7.5 meter long, etc complete all as specified. 129 Road Path Culvert 130 Item No 45 : S&F Traffic convex minor of size 800 mm dia unbreakable having clear and definite mirror image with upper class collar provided with suitable clamps & nut bolts. The complete set shall be fixed on MS pipe 65mm NB 2.0 meter long from Ground level duly powder coted/painted white/blue color etc complete all as specified and directed. 131 Electric Lift 132 Item No 46 : Design supply, install testing & commissioning passengers liftof capacity 8 passanger (544 Kg,) speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS14665, suitable to serve G + 03 upper floors with AC variable voltage & variable frequency drive (VVVF drave) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding staninless steel doors, car size-as per IS and suitable to install in install in lift well, door size- as per IS or manufacture specification, 133 automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near ground floor landing door) & human interface device all other finishes standard safety features should be as per IS specification and modern practices in market in lift complete all as specified below:- 134 (i) Contractor shall be submit detailed construction drawing of lift being provided with complete technical specification as per IS : 14665 (Including all ammenments till date) before dispatch the of material fro OEM for approval of GE. (ii) The scope of work also covered the all civil works, car and counter weight guide rails, brackets, terminal buffer support and sil angle, plates and any other items required for successful completion of lift with respect to safety required by OEM, and any other supprting structure required will be carried out by contractor without any extra cost 135 If any clearance required from state government i.e lift inspector/electrical safety department/ fire safety departments is the contractors responsibility & any expenditure on this account shall be deemed to be included in the quoted rates.(iii) any other component which are left out, but essentiality required as per OEMs design, shall be provided without any extra cost. 136 (iv) Lift technician shall be provided for 24x7 period including sunday and holiday by the contractor for its functioning, operation or any issue arising in the lift during defect liability period. Any maint/replacement of any items during defect liability period will be borne by he contractor.(v) Lift shall be taken over after inspection of lift by Sr IEM and all mandatory test/fitness obtain rom OEM consequent upon all satisfactory results. 137 Item No 47 : S&F for galvanised iron strip of size 25 mm x 4 mm for earth contunity conductor complete all as specified and directed. 138 Furniture 139 Item No 48 : Locker Steel FD-1029/257 140 Item No 49 : FD-1029/257FD-280 141 Item No 50 : Bed HardFD/E6/MAP/08® 142 Common Room 143 Item No 51 : Chair Writing FD-280 144 Item No 52 : Table 60x60 cmsFD-293 145 Study Room 146 Item No 53 : Chair Writing FD-280 147 Item No 54 : Table 90x60cm with DrawersFD-283/224 148 Cook House & Dining Hall 149 Item No 55 : Notice BoardFD-99R 150 Item No 56 : Chair DiningFD-279 151 Item No 57 : ReceptacleFD/E6/Map/13 152 Item No 58 : Table Dining 6 personsFD-376 153 Item No 59 : Chair EasyFD-229 154 Item No 60 : TeapoyFD-278 155 Item No 61 : Table Cook HouseFD-136M 156 Item No 62 : Meat SafeDB-405 157 Item No 63 : Hot CaseDB-3976 158 Item No 64 : Charpoy IP PlytopFD/Map-II/01 159 Item No 65 : Foam with BackFD-77M