Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-10-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-10-2025 |
| 2 | 01-10-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 08-10-2025 |
| 3 | 22-09-2025 | REVISED BOQ | BOQ | 03-10-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings Complete all as specified and as directed by Engr in Charge. |
| 2 | S & F for Pre- painted galvalume aluminum zinc coating GI based corrugatedsteel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws Complete all as specified and as directed by Engr in Charge. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof , ridge / valley gutter, fixed with self tapping screws Complete all as specified and as directed by Engr in Charge. |
| 4 | Dismantling of wall andceiling boards(fibre, pulp, insulationetc.) or insulation boards/ slabs/ blankets, any thickness including cover filletsComplete all as specified and as directed by Engr in Charge. |
| 5 | S&F hangers 6mm dia G.I. (upto 1200mm length ) adjusting level, size of grid 605mm X605mm, fixed to steel purlins or rafter with nexc 60cm long and 6mm dia adjustable Complete all as specified and as directed by Engr-in-charge. |
| 6 | S&FGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mmthick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clipsacross the intermediate channel at 457 mm centre to centre. size of grid 605mm X605mm Complete all as specified and as directed by Engr in Charge. |
| 7 | S&F Non asbestos fiber cement building board 6mm thick ( designerceiling board), fixed to aluminium or MS galvanised snap grid frame work with screw in ceiling Complete all as specified and as directed by Engr-in-charge. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for Complete all as specified and as directed by Engr in Charge. |
| 9 | Supply and fix steel work in tubular trusses/rafetr/purlin including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 Complete all as specified and as directed by Engr in Charge. |
| 10 | Demolition ofcement concrete in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level)Complete all as specified and as directed by Engr in Charge. |
| 11 | M&L for 50 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair Complete all as specified and as directed by Engr in Charge. |
| 12 | M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over Screed bed or bedding layer of cement mortar 1:6, 20 mm thick base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing Complete all as specified and as directed by Engr in Charge. |
| 13 | M & L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over Screed bed or bedding layer of cement mortar 1:4, 15 mm thick and jointed withgrey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing Complete all as specified and as directed by Engr in Charge. |
| 14 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc Complete all as specified and as directed by Engr in Charge. |
| 15 | M&L for Precast cement concrete 1:3:6 type C1 (Using 20 mm graded granite stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 Complete all as specified and as directed by Engr in Charge. |
| 16 | Taking down cement plaster any description from roof slab, stone wall, brick wall parapets including raking out joints hacking for key and scrubbing down with water etccomplete all as specified and as directed by Engr-in-charge. |
| 17 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finish the surface even and smooth without using extra cementall as specified and as directed by Engineer-In-Charge. |
| 18 | M&L for preparing new plastered surfaces and applying two coats of cement base paint onwall surfaceover one coat of alkali resistant primer Complete all as specified and as directed by Engr in Charge. |
| 19 | M&L preparing newly plastered surfaces of wall and applying two coats of oil bound distemper , over a coat of primer over a coat of wall putty Complete all as specified and as directed by Engr in Charge. |
| 20 | M & L forold decorative surfaces, preparation of wall and applying two coats of cement base paint complete all as specified and as directed by Engr-in-charge. |
| 21 | M&L 75 mm thick cement concrete type C2, 1:3:6 (using 40 mm gradedstone aggregate) in plinth protections, finished even and smooth w/o using extra cementincluding necessary joints complete all as specified and directed by Engr in charge |
| 22 | Taking down Chowkats or frames not exceeding 1.5 Sq. M each (without taking off shutters from the frames) Complete all as specified and as directed by Engr in Charge. |
| 23 | Taking down chowkats or frames exc 1.5 sqm but not exceeding 4 sqm each but with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engr-in-charge. |
| 24 | S&F pressed steel frames 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,Complete all as specified and as directed by Engr in Charge. |
| 25 | S&F 2nd class hardwoodfactory made 30 mm thick flushshutter solid core construction with block board core & plywood face panels commercial type on both sides incl 5mm thick teakwood leaping alround Complete all as specified and as directed by Engr in Charge. |
| 26 | Supply and fixing (factory Made)2nd class hard wood35 mm thick glazed and skelton shutters open rebated and prepared to receive gauge.(Without sash bars) edges of framing plain chamfered or rounded fittedwith cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a) supplied and fitted to chowkatsComplete all as specified and as directed by Engr in Charge. |
| 27 | M&LAluminium anodised, barrel tower bolts of extruded section and fixed of size 150 mm complete all as specified and as directed by Engr-in-charge. |
| 28 | S&F 150 mm long aluminium anodised handles or extruded section Complete all as specified and as directed by Engr in Charge. |
| 29 | S&F 250mm long Aluninium alloy, anodised , sliding door bolt with hasp , staple,(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy Complete all as specified and as directed by Engr in Charge. |
| 30 | S&F butt hinges, medium weight, cold rolled mild steel, size 100mm Complete all as specified and as directed by Engr in Charge. |
| 31 | S&F Mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate Complete all as specified and as directed by Engr in Charge. |
| 32 | S&F floordoor stopper 140 mm of aluminium alloy body and tongue anodised with hard drawn steel springcomplete all as directed by Engineer-in-charge. |
| 33 | Supply & fixing for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm & fixed with tinned tacks, or galvanised wire staples. & directed by Engr-in-charge. |
| 34 | Supply and fixsteel windowsfor industrial buildings fixed type with glazing bars, complete with glazing bars for glazed shutters, dovetailed or welded Complete all as specified and as directed by Engr in Charge. |
| 35 | S&F plain sheet glass of 4 mm thick in squares not exceeding 0.50 Sqm in each pane with oil putty and clips complete all as directed by Engineer-in-Charge. |
| 36 | Supply and fixed Steel rolling shutters, with outball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat ofprimer; erected in position as indicated, complete:push pull ormanual type in position as indicated Complete all as specified and as directed by Engr in Charge. |
| 37 | Supply and fixed safety lever locks mild steel with 4 levers for rolling shutters Complete all as specified and as directed by Engr in Charge. |
| 38 | M & L preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 39 | Ditto- all as per item 38 above but one coat of synthetic enamel paint on old steel surfaces of any description Complete all as specified and as directed by Engr in Charge. |
| 40 | M&L for 75mm thick PCC 1:3:6 type C 2 using 40mm graded stone aggregate as in sub base of floor Complete all as specified and as directed by Engr in Charge. |
| 41 | M&L for 50mm thick cement concrete 1:2:4 type B-1 using (20 mm graded stone aggregate) and laid in alternate bays as inhard standing & finished the surface even & fair without using extra cement Complete all as specified and as directed by Engr in Charge. |
| 42 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard/dense soil Complete all as specified and as directed by Engr in Charge. |
| 43 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil. Complete all as specified and as directed by Engr in Charge. |
| 44 | M & L for cement concrete type D2 1:4:8 using 40mm graded stone aggregate in foundations, filling and mass concrete. Complete all as specified and as directed by Engr in Charge. |
| 45 | M & L for 40 mm thick Cement Concrete M-15 Nominal Mix (using 12.5 mm graded stone aggregate) as in damp proof course (DPC) to horizontal or vertical surfaces including necessary form work and mixing of water proofing compound as per manufacturer’s instructions complete all as specified and directed. |
| 46 | M&L for Hard core of gauge n exc 63mm thick of broken boulder spread leveling watering ramming to true surface complete all as specified and directed by Engr-in-Charge.. |
| 47 | M&L for 75mm thick P.C.C 1:4:8 type D-2 in sub base of floorComplete all as specified and as directed by Engr in Charge. |
| 48 | M & L for 25 mm thick PCC 1:2:4 type B1, 20 mm graded stone aggregate as in flooring including finishing cement concrete rough surface with out using extra cement Complete all as specified and as directed by Engr in Charge. |
| 49 | M & L for non skid coloured ceramic tiles 7 to 8mm thick square / rectangular area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floor laid over 15 mm thick screed bed in CM 1:6 as in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match the surface of tile Complete all as specified and as directed by Engr in Charge. |
| 50 | M & L for glazed ceramic coloured tiles of300x 450x 7 mm thick as on vertical surfacesand rises to steps etc. over 10mm thick rendering in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile Complete all as specified and as directed by Engr in Charge. |
| 51 | M&L for RCC 1:2:4 type B-1, ( using 20 mm graded stone aggregate ) as inplinth beams, cantilevers, bed block, bressummers, lintels over 1.5m span , including necessary form work etc Complete all as specified and as directed by Engr in Charge. |
| 52 | M & L for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smoth without using extra cement Complete all as specified and as directed by Engr in Charge. |
| 53 | Returning filling in including speading,leveling ,watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed by Engr-in-Charge. |
| 54 | Removing of excavated soil n exc 50m and depositing where directed at a level n.exc 1.50m above the starting point Complete all as specified and as directed by Engr in Charge. |
| 55 | M & L for precast cementconcrete M-15 Nominal Mix (1:2:4) (using 20 mm graded stone aggregate), as in lintels upto 1.5 m clear span, cills, steps, etc complete allas directed including necessary form work as required Complete all as specified and as directed by Engr in Charge.. |
| 56 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips Complete all as specified and as directed by Engr in Charge. |
| 57 | M & L for mild steel TMT bars 5 mm dia and over upto 8 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips Complete all as specified and as directed by Engr in Charge. |
| 58 | M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, bands, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete Complete all as specified and as directed by Engr in Charge. |
| 59 | M&L for MS frame work asroof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing of Fe 410W (Gde-E-250) etc (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Complete all as specified and as directed by Engr in Charge. |
| 60 | S&F For Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel,complete all as specified and directed by engr in charge. |
| 61 | S & F compound girders and stanchions, lattice girders, aerial masts, staging for water tank including all lattice bars, stiffeners, gusset plates, etc.Fe-410-W(gde-E-250)Complete all as specified and as directed by Engr in Charge. |
| 62 | & F for rotational moulded polythylene water storage tanks of capacity 1000 ltr (Cylindrical vertical with closed top) hoisted and fixed in position incl 20mm dia ballvalve high pressure of PTMT with epoxy coated alluminium rod and high density plastic ball secrewed for iron pipe and fixedComplete all as specified and as directed by Engr in Charge. |
| 63 | S&F15 mm dia of pipe Gun-metal, globe or gate valvees with iron wheel head, screwed both ends for iron pipe and fixed.Complete all as specified and as directed by Engr in Charge. |
| 64 | S&F20 mm dia of pipe Gun-metal, globe or gate valvees with iron wheel head, screwed both ends for iron pipe and fixed.Complete all as specified and as directed by Engr in Charge. |
| 65 | S&F 15mm bore galvanised steel tubes,\"medium grade\"with all fitting and fixed complete to walls and ceilings or laid in floorsand cutting chases for concealed water Complete all as specified and as directed by Engr in Charge. |
| 66 | S&F 20mm bore galvanised steel tubes,\"medium grade\"with all fitting and fixed complete to walls and ceilings or laid in floors Complete all as specified and as directed by Engr in Charge. |
| 67 | S&Fviterious china squatting pan orissa pattern size 580x440mm white integal foot rest, including concrete bedding with trap 100mm complete all as specified and directed by Engr in Charge. |
| 68 | Supply & fixed (in repair) vitreous china wash down water closet pedestal pattern (EWC) , White including connection to trap and to flushing pipe with ‘P’ or ‘S’ trap, making good to floor, plastic water closet seat cover with mild steel chromium plated hingesComplete all as specified and as directed by Engr in Charge. |
| 69 | S&F 10 ltr capacity PVC valveless , syphonic action type flushing cistern, low level, white, with inlet ball valve, float and handle including brackeet and 32mm dia flush pipe of polyethylene of low or high density for low level cistern Complete all as specified and as directed by Engr in Charge. |
| 70 | S&F for Wash basins, Vitreous China (flat back or angle back type) size 580X450mm, including cutting for and pinning in ends of brackets or erecting stand incl pillar tap etc, Complete all as specified and as directed by Engr in Charge. |
| 71 | S&F vitreous china urinal half stall type flat back size ofwhite with grating and union for discharge pipe including chromium plated water spreader , connection pipe and discharge down pipe Complete all as specified and as directed by Engr in Charge. |
| 72 | S & FSheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long Complete all as specified and as directed by Engr in Charge. |
| 73 | S&Fbib taps 15mm diafancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed. complete all as specified and directed by Engr In Charge. |
| 74 | S&Fbrass CP Stop cock/ Angle cock 15mm fancy type choromium plated etc, Complete all as specified and as directed by Engr in Charge. |
| 75 | S&F brass CP mixer, 15mm bore for mixing hot & cold water screw down for iron pipe , Complete all as specified and as directed by Engr in Charge. |
| 76 | S&F for waste coupling of PTMT for 32 mm bore dia of discharge pipe (half or full threaded) ) complete all as specified and directed by Engr In Charge |
| 77 | S&F PVC connections 15mm size with PTMT nuts of length 600mm Complete all as specified and as directed by Engr in Charge. |
| 78 | S&Ffloor trap 75mm out let dia with grating including jointing to waste pipefixed in cement concrete Complete all as specified and as directed by Engr in Charge. |
| 79 | S & F 75 mm dia bore PVC (SWR) pipes single socketed , in any length with rubber ring joints , laid in tenches or in floors Complete all as specified and as directed by Engr in Charge. |
| 80 | S & F 110 mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints incl hunching & bunching, laid in tranches or in floors Complete all as specified and as directed by Engr in Charge. |
| 81 | S & F75 mm diabore PVC (SWR) bends any radius Complete all as specified and as directed by Engr in Charge. |
| 82 | S & F110 mm diabore PVC (SWR) bends any radius Complete all as specified and as directed by Engr in Charge. |
| 83 | S&F soap dish chromium plated embedded in the wall or screwed Complete all as specified and as directed by Engr in Charge. |
| 84 | S & F of 20 mm dia Aluminium anodised tubular towel rail 600 mm longincluding brackets Complete all as specified and as directed by Engr in Charge. |
| 85 | S & F solid PVC doorframe of size 50mm x 47mm made out of5 mm plain colour PVC sheet reinforced with M.S. square tubeetc Complete all as specified and as directed by Engr in Charge. |
| 86 | S & Ffactory made solid PVC moulded door shutter, 30 mm thick 2mm thick 3D wood grain Moulded PVC sheet polyurethane painted on the front face & 2mm plain colour PVC sheet on back face Complete all as specified and as directed by Engr in Charge. |
| 87 | S & F600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers Complete all as specified and as directed by Engr in Charge. |
| 88 | Provn ofSeptic tank of capacity 10 user all as specified as shown on Drg. Complete all as specified and as directed by Engr in Charge. |
| 89 | M&L for soakage pit 3.0m bottom dia and 3 m deep inclexcavation and earth work and loose filling with broken stone all as sfd and shown on drg.Complete all as specified and as directed by Engr in Charge. |
| 90 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair Complete all as specified and as directed by Engr in Charge. |
| 91 | M & L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough Complete all as specified and as directed by Engr in Charge. |
| 92 | M&L for Chequered cement concrete tiles25mm thick with grey cement and no pigment set and jointed in neat cement slurry and pointed in white or coloured cementComplete all as specified and as directed by Engr in Charge. |
| 93 | M & L for providing cement concrete1:2:4, type B1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edge including use of formwork Complete all as specified and as directed by Engr in Charge. |
| 94 | S & F toilet paper holder,vitreous china box type fixed to wall with chromium plated brass screws Complete all as specified and as directed by Engr in Charge. |
| 95 | S & F for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position Complete all as specified and as directed by Engr in Charge. |
| 96 | Cuttingintoexistingmanholes 110mm dia for connecting new drains, making goodto pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required Complete all as specified and as directed by Engr in Charge. |
| 97 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc Complete all as specified and as directed by Engr in Charge. |
| 98 | M&L forpoint wiring using approved colour coding as per IS by using FRLS PVC insulated 1.5 Sqmm multistranded,1100 volt grade copper conductor cable unsheathed type, alongwith 1.5 Sqmm FRLS PVC insulatedstranded copper conductor cable for continous earthing in & incl casing capping point wiring with accessories having ISI mark for one light/fan/bell point/5 amp indep/power point/same board controlled by one switch Complete all as specified and as directed by Engr in Charge. |
| 99 | All as per item No 98 here-in-before but for one multipin socket outlet 5 Amp but using 2x 1.5 + 1 x 1.5sqmm multistranded FRLS copper cable onthe independent board Complete all as specified and as directed by Engr in Charge. |
| 100 | All as per item No 98 here-in-before but for one multipin socket outlet 5 Amp on the same board with other switches Complete all as specified and as directed by Engr in Charge. |
| 101 | All as per item No 98 here-in-before but for one multipin socket outlet 15 Amp,but using 2 x2.5 +1 x 2.5sqmm multistranded FRLS copper cable, independent board Complete all as specified and as directed by Engr in Charge. |
| 102 | S&F in replacement of switch piano type 5 Amp, 230 Volt, flush type single pole one wayComplete all as specified and as directed by Engr in Charge. |
| 103 | S&F in replacement of socket outlet multipin 5 Amp 230 Volt flush typeComplete all as specified and as directed by Engr in Charge. |
| 104 | S&F in replacement of switch piano type 15 Amp, 230 Volt, flush type single pole one wayComplete all as specified and as directed by Engr in Charge. |
| 105 | S&F in replacement of socket outlet multi pin 15 Amp 230 Volt flush type Complete all as specified and as directed by Engr in Charge. |
| 106 | S&F In replacement offorLamp holder, PVC/Polycarbonate type with back plate suitable for Angle/batten fittings Complete all as specified and as directed by Engr in Charge. |
| 107 | S&F of rechargeable led bulb minimum 4 Hrs Battery backup 9 Watt B-22 Base Complete all as specified and as directed by Engr in Charge. |
| 108 | S&F in rplacement of Ceiling rose, 3 terminal, PVC isolated body Complete all as specified and as directed by Engr in Charge. |
| 109 | S&F in replacement of LED light fitting 20W, 220 volt AC, having colour temperature daylight (6500K), Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose Complete all as specified and as directed by Engr in Charge. |
| 110 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size Complete all as specified and as directed by Engr in Charge. |
| 111 | S&F including flushing in wall MCB distribution board vertical TPN 4 way 415 volt AC doublr door sheet with bus bar neutral earth bar including provision of MCB TPN 63 amp conforming to IP 43 as incomerComplete all as specified and as directed by Engr in Charge. |
| 112 | S&F MCB TPN 63 amp 415 volt with bearing capacity of 16 KA Complete all as specified and as directed by Engr in Charge. |
| 113 | S&F in replacement ofsheet metal enclosure double door distribution board single pole and neutral, 12 way 240 volt with 100 amps rated bus bar complete with bus and neutral linkComplete all as specified and as directed by Engr in Charge. |
| 114 | S&F in replacement of MCB 6 to 32 amp rating 240V, 10KA \"B\" curve, Single pole in the MCB DB complete with connection testing and commissioning Complete all as specified and as directed by Engr in Charge. |
| 115 | S&F in replacement of MCB SPN 40 amp2 amp rating 240V, 10KA \"B\" curve, Single pole in the MCB DB complete with connection testing and commissioning Complete all as specified and as directed by Engr in Charge. |
| 116 | Supply & laying LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 16 sqmm 4 core as per IS specification laid through GI pipe/on floor/wall Complete all as specified and as directed by Engr in Charge. |
| 117 | Supply and laying of GI pipe light galvanized with all fitting laid in trenches for cable proctection of 50 mm bore Complete all as specified and as directed by Engr in Charge. |
| 118 | M&L in replacement of Earthing complete with galvanised steel earth plate electrode 600×600×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mmdia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on Complete all as specified and as directed by Engr in Charge. |
| 119 | Supply and fixing Building LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection Complete all as specified and as directed by Engr in Charge. |
| 120 | Supply, laying and drawing in and including 20 mm dia casing caping including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection Complete all as specified and as directed by Engr in Charge. |
| 121 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in softloose soil for laying / taking up/ taking down of cablesand getting out and leveling of bottom surface to required level all as specified and directed by Engineer- in- Charge. |
| 122 | Returning filling in,. Including spreading, leveling,. Watering and well ramming soil in layers not exceeding 25 cm thick Complete all as specified and as directed by Engr in Charge. |
| 123 | Removing excavated material (i.e. soil) from site to a distance n. exec 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge. |
| 124 | M&L for sand filling floors or in foundation including watering and compansation Complete all as specified and as directed by Engr in Charge. |
| 125 | M&L for old size bricks common burnt clay building bricks sub class B designation 75 Complete all as specified and as directed by Engr in Charge. |
| 126 | Supply and fixing ceiling fans complete with blades, down rods, remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) Complete all as specified and as directed by Engr in Charge. |
| 127 | S&F in replacement of stepped type electronic fan regulator flush type, Complete all as specified and as directed by Engr in Charge. |
| 128 | S&F for fixing of GI pipe (light grade) bracket of 40mm diasize of 1.2 mtr long bent to shape for fixing of LED street light fittings and fixing to pole, walls etc including fixing of clamp, nut, bolt etc Complete all as specified and as directed by Engr in Charge. |
| 129 | S & F in replacement of LED light fitting 10 W, 2 ft 220 volt AC, having colour temperature daylight (6500K), Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose Complete all as specified and as directed by Engr in Charge. |
| 130 | S & F in replacement ofsheet metal enclosure double door distribution board single pole and neutral, 4 way 240 volt with 200 amps rated bus bar complete with bus and neutral linkComplete all as specified and as directed by Engr in Charge. |
| 131 | Supply & laying LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 6 sqmm 2 core as per IS specification laid through GI pipe/on floor/wall Complete all as specified and as directed by Engr in Charge. |
| 132 | S&F metal type exhaust fan single phase 230/240V of 300 mm sweep including louvre & cutting of holes in a round shape and including fixing the exhaust fan Complete all as specified and as directed by Engr in Charge. |
| 133 | S & F in replacement ofsheet metal enclosure double door distribution board single pole and neutral, 8 way 240 volt with 200 amps rated bus bar complete with bus and neutral linkComplete all as specified and as directed by Engr in Charge. |
| 134 | Supply & laying LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 10 sqmm 2 core as per IS specification laid through GI pipe/on floor/wall Complete all as specified and as directed by Engr in Charge. |
| 135 | S &F testing water heater storage type with multifunctional safety valve, electric operated 230V single phase complete including one no of heating element, automatic, thermal cut out, fusible plug, anti vacum sys, built in presser release valve, thermostat, rust proof powder coated body, indicator lamps and all safety advices as per E-in-C\"s Branch technical instructions and of capacity 25 litres including provn of grouting bolts in walls including piller cock, PVC connection etc and making good disturbed surfaces. Make: CG/Racold/Havells/Bajaj/indo and complete all as specified and directed by Engr in Charge. |
| 136 | Schedule of Credit |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy