| 1 | CIVIL WORKS |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 3 | Brick on edge flooring with bricks of class designation 7.5 on a bed of12 mm cement mortar, including filling the joints with same mortar, withcommon burnt clay non modular bricks:1:6 (1cement : 6 coarse sand) |
| 4 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from naturalsources : 6 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tensile steel bars |
| 6 | Centering and shuttering including strutting, propping etc. and removalof form forFoundations, footings, bases of columns, etc. for massconcrete |
| 7 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 9 | Supplying and filling in plinth withsand under floors, including watering,ramming, consolidating and dressing complete. |
| 10 | Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources) |
| 11 | Brick on edge flooring with bricks of class designation 7.5 on a bed of12 mm cement mortar, including filling the joints with same mortar, withcommon burnt clay non modular bricks:1:6 (1cement : 6 coarse sand) |
| 12 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 13 | 62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate, 6mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacture’sspecifications. This includes cost of cement slurry, but excluding thecost of nosing of steps etc. complete. |
| 14 | 15 mm cement plaster on the rough side of single or half brick wall ofmix :1:6 (1 cement: 6 fine sand) |
| 15 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 16 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 17 | Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :Water thinnable cement primer |
| 18 | Wall painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade :Two or more coats on new work |
| 19 | Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 20 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 21 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 micronsminimum to avoid scratches during transportation and should besupplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto anypitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shapewherever required. |
| 22 | Providing and fixing precoated galvanised steel sheet roofingaccessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester topcoat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 23 | Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length andjointed together at the end by end locks, mounted on specially designedpipe shaft with brackets, side guides and arrangements for inside andoutside locking with push and pull operation complete, including thecost of providing and fixing necessary 27.5 cm long wire springsmanufactured from high tensile steel wire of adequate strengthconforming to IS: 4454 - part 1 and M.S. top cover of required thicknessfor rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 24 | Providing and fixing G.I. chain link fabric fencing of required width inmesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction ofEngineer-in-charge.Made of G.I. wire of dia. 4 mm, PVC coated to achieveouter dia not less than 5 mm in required colour and shade |
| 25 | Applying priming coat: With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel work (secondcoat) |
| 26 | Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer\"s specifications including appropriatepriming coat, preparation of surface, etc. complete. On steel work |
| 27 | Sanitary and Water Supply |
| 28 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls andfloors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 29 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the wallswherever require:White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps |
| 30 | Providing and fixing C.P. brass stop cock (concealed) of standarddesign and of approved make conforming to IS:8931.15 mm nominal bore |
| 31 | Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 :15 mm nominal bore |
| 32 | Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) :25 mm nominal bore |
| 33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge. |
| 34 | 20 mm nominal dia Pipes |
| 35 | 25 mm nominal dia Pipes |
| 36 | 65 mm nominal dia Pipes |
| 37 | 100 mm nominal dia Pipes |
| 38 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete.Flexible pipe,32 mm dia |
| 39 | Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms |
| 40 | Providing and fixing uplasticised PVC connection pipe with brassunions :45 cm length,20 mm nominal bore |
| 41 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 42 | Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete :25 mm nominal bore |
| 43 | Construction of 50 users Septic tank with 233 mm brick masonry wall including partition wall & buffel wall 125 mm including neat cement pplaster on inside walls & bottom on the top of concrete base, PCC, RCC cover slab of 75 mm thick & necessary PVC pipe connections etc. as directed by the Engineer incharge. |
| 44 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm drybrick honey comb shaft with bricks and S.W. drain pipe 100 mmdiameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 45 | Electrification work |
| 46 | Supply, fitting and fixing of Industrial type water proof twin LED tube light (IP65) simillar to Philips Cat No.TCW450 P 2XTLED 19W P3397 with connections etc. complete as directed. |
| 47 | Supply ofORIENT FARATA OZ or simillar makepedesta(stand) fan. |
| 48 | Supply, fitting and fixing of Industrial type 400mm sweep exhaust fan |
| 49 | Supplyof 25Sq.mm 3½ core armoured aluminium conductor with PVC/XLPE insulated underground cable |
| 50 | Laying of one no. PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of follopwing size direct in ground including excavation, sand cushioning , protective covering and refilling the trench etc. as required.Upto 35Sq.mm |
| 51 | Wiring for circuit/submain line alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface /recessed medium class PVC conduit as required. |
| 52 | 2 X 4 Sq.mm + 1 X 4 Sq.mm earth wire. |
| 53 | 4 X 10 Sq.mm + 2 X 6 Sq.mm earth wire |
| 54 | Supplying and fixing metal box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required |
| 55 | ( 200 X 150 X 60) mm deep (02 for lighting) |
| 56 | ( 150 X 150 X 60) mm deep |
| 57 | Supplying and fixing following piano type switch/Socket on the existing switch box/cover including connections etc. as required. |
| 58 | 5/6A Switch |
| 59 | 3 pin 5/6A socketoutlet |
| 60 | 155/16A switch |
| 61 | 6pin 15/16A socket outlet |
| 62 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB DB 415V on surface /recess complete with tinned copper bus bar, neutral bus bar, earth bar din rail intercoknnections, powder painted including earthing etc. as required(without MCB)4way (4+12), double door |
| 63 | Supplying and fixing 5A to 32A rating, 240/415V, 10KA, \"C\" curveMiniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole, 6-32A |
| 64 | Supplying and fixing following rating, four pole 415V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A |
| 65 | Providing and fixing following capacity TP&N disconnector fuse switch unit with ISI marked HRC fuse including drilling holes making connections etc., as required(Main switch). 100A |
| 66 | Earthing with GI earth pipe 4.5Mtr long, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc., with charcoal/coke and salt as required. |
| 67 | Providing and fixing 6SWG GI wire on surface or in recess for loop earthing as required |