Construction Of Sdm Office At Thanamandi Rajouri- 1 Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge All kinds of soil : 2 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil : 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M. 4 Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete 5 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) ground floor area 7 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) saucer drain ground floor area 8 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) below plinth to hold earth 9 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 11 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 12 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 13 Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with:1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) Waste slab of stair case 14 Steel Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more 15 Centering and shuttering including strutting, propping etc. and removal of form work for :- 16 Foundations, footings, bases of columns etc. for mass concrete 17 Columns, Pillar, Pier, abutments, posts and struts 18 Lintel, beams, plinth beams, girders, bressumers and cantilevers 19 Suspended floors, roofs, landings, balconies and access platforms 20 Edges of slabs and breaks in floors and walls Under 20 cm wide 21 Stairs (excluding landings) except spiral staircases. 22 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) 23 Extra for brick work in super structure above plinth level upto floor V-level. 24 Half brick masonryHalf brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :Cement mortar 1:3 ( 1 cement : 3 coarse sand) 25 Extra for half Brick masonry in superstructure above plinth level upto floor V level 26 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 27 CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 28 Frames and trusses Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): 29 Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).Second kail wood - 35MM THICK SHUTTER 30 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws- 35 MM THICK 31 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured) 32 Extra for providing vision panel not exceeding 0.1 sqm in all types of flush doors (Cost of glass excluded) (overall area of door shutter to be measured) 33 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 34 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Float glass panes 5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm) 35 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia wire and 1.4 mm wide aperture with matching wood beading 36 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete Fixed to openings / wooden frames with rawl plugs screws etc. 37 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with10 mm diameter bolts, nuts and wooden plugs and embeddings in cementconcrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size). 38 Providing and fixing bright finished brass door latch with necessary screws etc. complete. : 39 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete.250x10 mm 40 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. 125mm 2 handles per shulter Doors. 41 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. completeTwin rubber stopper 42 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-ChargeThree track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto1.75 sqm). 43 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) 44 CostFloat glass panes of nominal thickness 5 mm (weight not less than12.50 kg/sqm)AS PER JKPSR ITEM NO. 9.149D.2AS PER JKPSR ITEM NO. 9.149D.4 45 VITRIFIED FLOOR TILESProviding and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching Pigments etc. complete.Size of tile 600x600 mm 46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints.Size of tile 600x600 mm 8 % OF jksor ITEM NO. 11.52.2 47 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.FRONT landing 48 Stone tile work for wall lining upto 10m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade.8mm thick (mirror polished and machine cut edges) Granite stone of any colour and shade risers 49 Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work steps 50 CEMENT PLASTER (IN FINE SAND)12mm Cement plaster of mix:1:6 (1 cement : 6 fine sand)total brick quantity- 9urface area of one side of brick work QTY. AS PER JKSOR ITEM NO.6.15.1 51 15mm cement plaster on the rough side of single or half brick wall of mix in 1:6 (1 cement : 6 fine sand).same asJKSOR ITEM 13.1.2 52 6MM CEMENT PLASTER 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)floor slabs 53 Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications:Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture Sal wood 54 French spirit polishing, Two or more coats on new works including a coat of wood filler 2 times area of flush doors, as per JKSOR item no. 9.21.1 55 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick 56 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/liter 57 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats 58 EXTERIOR FINISHINGFinishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) 59 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work GRILL LS 60 Carriage of material from source to site of work by mechanical transport including loading /unloading and stacking complete. 61 Sand for an average distance of 150 kms by M.T 62 Sand for RCC work/CC work for an average distance of 150 kms by M.T 63 Stone aggregate below 40 mm nominal size for anaverage distance 40 kms by M.T 64 Bricks for an average distance up to155 km by M.T 65 Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid , 10 liter low level white vitreous chinaflushing cistern and CP flush bend with fittings and C.I. brackets, 40mmflush bend, overflow arrangement with specials of standard make andmosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good thewalls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. 66 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 67 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 68 Providing and fixing white vitreous china battery based infrared sensoroperated urinal of approx. size 610 x 390 x 370 mm having pre &post flushing with water (250 ml & 500 ml consumption), havingwater inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction ofEngineer-in-charge. 69 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as perI.S. 13983 with C.I. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the wallswherever required :Kitchen sink with drain board 510x1040mm bowl depth 250mm 70 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:Semi rigid pipe - 40 MM DIA 71 Providing and fixing mirror of superior glass (of approved quality) and ofrequired shape and size with plastic moulded frame of approved makeand shade with 6 mm thick hard board backing Rectangular shape 1500x450 mm 72 Providing and fixing toilet paper holderwith Flap made out of C.P Brass 73 Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. . 74 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. 75 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge 76 Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 77 Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms 78 Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 79 Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931 80 Providing and fixing CP Brass Single lever telephonic wall mixer ofquality & make as approved by Engineer in charge.(a) 15 mm nominal dia 81 Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. 82 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter 83 Providing and fixing soil, waste and vent pipes IS 13592 & fittings (IS: 14735 ) suitable to rubber ring joints , which includes bends, rubber ring, jointing, junctions, clean out plug , cowls, offsets, collar, M.S holder-bat clamps, access pieces, trap of self cleansing design .etc. complete including jointing.110 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B(NSI) 84 75 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B 85 Providing and fixing of Rain Water pipes IS 13592 & fittings (IS: 14735 ) suitable to rubber ring joints , which includes bends, rubber ring, jointing, junctions, clean out plug , cowls, offsets, collar, M.S holder-bat clamps, access pieces, trap of self cleansing design .etc. complete including jointing.110 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-A110 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-A 86 Providing and Fixing of Floor Traps 110 mm with double chrome plated Cover one Grated and one closed and all other fittings required.Makes:- Astral/SFMC/Finolex(NSI) 87 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominalsize), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III): 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished withfloating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mmnominal size) finished with a floatingcoat of neat cement complete as perstandard design :Inside size 90x80 cm and 45 cm deep including C.I. cover withframe (light duty) 455x610 mm internal dimensions, total weight ofcover and frame to be not less than 38 kg (weight of cover 23 kg andweight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 88 Supply, Installation of PVC Gully Trap of Size 110 mm(NSI) 89 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer-in-charge.(SDR-11) Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.15mm nominal outer dia pipes 90 20mm nominal outer dia pipes 91 25mm nominal outer dia pipes 92 External work including trenching and refilling etc.complete 40mm nominal outer dia pipes. 93 Providing and fixing unplasticised PVC connection pipe with brass unions:45 cm length 94 15 mm nominal bore Cutting holes upto 30x30 cm in walls including making good the same with common burnt clay F.P.S.(non modular) bricks 95 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 16 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.25 mm Diameter(NSI) 96 Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brickhoney comb shaft with common burnt clay (non modular) bricks of classdesignation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m longcomplete as per standard design 97 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 98 Supply,Installation,Testing and Commissioning of water Pump with a Discharge of 6.0 Cu.m/hr @Head of 45 MetersComplete with all accessories including header Pipes, allied materials and Control Panel. (NSI) 99 Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group B 100 Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. 101 Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire 102 4 X 6.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire 103 4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire 104 2 X 6.0 SQ.MM + 1 X 6.0 SQ.MM Earth Wire 105 Supply and fixing of modular plate 106 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required.Computer Socket 107 Telephone Socket 108 Television Socket 109 Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required.1 or 2 Module (75mmX75mm) 110 Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required.25 mm 111 Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. 112 Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. 113 Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. 114 Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V C curve DP MCB complete withconnections, testing and commissioning etc. as required. 115 Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4 + 24), Double door 116 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole 117 Single pole and neutral 118 Supplying and fixing 40-63 AArating, 240/415 V, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single pole and neutral(NSI) 119 Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.Bin the existing MCB DB complete with connections, testing andcommissioning etc. as required.32 A F.P MCB 10 Ka C Curve(NSI) 120 63 A F.P MCB 10 Ka C Curve(NSI) 121 Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required.(NSI) 122 Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required.12 way , Double door 123 Supplying,Installation,Testing and Commissioning ofG.I Earthing Electrode of Size 50 x 3000mm with GI Pipe Outer Dia. 58 mm (+-) 5 %,Length 3000 mm,Inner & Outer GI Strip Size 32X6mm,Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs.(NSI) 124 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm) 125 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body materialand construction as per IS : 10322 withdriver (Replaceable)as per the requirement with Driver efficiency >85% ,Operating voltage AC140-270 Volt,freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80, Flicker free, (flickershould be below 5 %), life time (LED,Driver & electrical circuitary), ofminimum 50000BurningHourswith,70%ofinitial Lumenmaintained tilllife ends, CCT3000°K/ 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard andtrade markcertificate(T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥105 <120lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures asper BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C). Powdercoated die cast/ Extrudedaluminium Body (Thickness≥ 1.20 mm)40 watt 126 Supply installation testing and commissioning ofCeiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.1200 MM(NSI) 127 Supplying, installation, Testing & Commissioning of Flood Light,powder coated pressure die cast aluminum body with built in or separatedriver as per the requirement with Driver efficiency >85%, Input voltage:Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 degto 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltageprotection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tiltable fitting, life time (LED,Driver & electrical circuitry) of minimum 50000Burning Hours with 70% of initial Lumen maintained till life ends as perLM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation ColorMatching) <5, Maximum power consumption should not more than thespecified rating and Fixture shall be of relevant BIS standard complete inall respect i/c connections with 1.5 sq mm FRLS, PVC insulatedcopper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall beas approved by Engineer-in-Charge as per requirement. (Thermalmanagement: heat sink of aluminum housing such that LED junctiontemperature shall not rise above 90°C).100 watt 128 Supply,Installation,Testing and Commissioning 300 mm ,486 Cu.m/Hr. AC220-240Volts, 50 Hzexhaust fan made out ofPlasticBody with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dBof Following Sizes including connection etc. complete as required . 129 Supplying, installation, Testing & Commissioning ofLED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD typeof following bodymaterialwith PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 degto40degcentigrade,internalsurgeprotectionof2.5KVwithShort&Opencircuit protection ,THD < 10% , P. F.≥0.95,IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%),life time (LED,Driver & electrical circuitary), of minimum50000 Burning Hours with70% of initial Lumenmaintained tilllife ends , CCT 3000°K /4000°K/ 5700°K / 6000°K / 6500°K (AsperANSI Bin), SDCM (Standard Deviation Color Matching) <3,Maximumpowerconsumptionshouldnotmorethan the specified rating and Fixture shall be confirming to relevant BIS standards andtrade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing Completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as requiredwith Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C)Powdercoateddiecast/Extruded aluminum Body including trim 12 -15 watt 130 Supply installation testing and commissioning of IP:20 AluminiumBatten 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The inputvoltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab.(NSI) 131 Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)(Building DistributionPanel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagrambefore start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall beCPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .(In Ground FloorBelow Staircase Wall Hung)(NSI) 132 Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100%Breaking Capacity 36KA with Extendable ROH 133 Adj. TMR Based MCCB100 Amps FP Icu=Ics=100%Breaking Capacity 36 KA with Extendable ROH 134 150 A,415 Volts 50Hz Aluminium Busbarset of 4 strips 135 100 A,415 Volts 50Hz Aluminium Busbar set of 4 strips 136 Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. 137 Manual Changeover 63 A F.P 415 Volts AC-23 Duty 138 MCB 63 A F.P 10 KaC Curve 139 MCB 32 A F.P 10 KaC Curve 140 MCB 32 A D.P 10 KaC Curve 141 Load Bearing Members to be made out of 2.0 mm CRCA Sheet.Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick.Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal) 142 Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.3.5 C X 35 Sq.mm A2XFY(NSI) 143 Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet)3½ X 35 sq. mm (32mm) 144 Providing and fixing on wall 35 LTRS Electric Geyser with ABS Body. 145 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/recessed steel/ PVC conduit asrequired.2 Pair 146 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mmsolid copper conductor PE insulated, shielded with fine tinnedcopper braid and protected with PVC sheath in the existingsurface/ recessed steel/ PVC conduit as required. 147 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in theexisting surface/ recessed Steel/ PVC conduit as required 1 run of cable 148 Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC (NSI) 149 Supply&Erectionoflockable 12 Urackwith5Astripand twofanfordistribution,mountingofpatchpanels,hubs, switches etc,, complete as per specification and as desired by EIC.(NSI) 150 2.2 KVASine Wave Inverter , Input 1 Phase 3 wire and output 1 phase 3 wire with 2 Nos of 12 V 200 aH Battery.(NSI)